Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde



Similar documents
Series TMM Axial Piston Motor. Technical Information

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Variable Displacement Pump AA10VSO

Series PVP Variable Volume Piston Pumps

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK March 2004

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Rexroth Hydraulic Pump A10VO Series User Manual

HYDRAULIC MOTORS HYDRAULIC SYSTEMS DIVISION. Outstanding Hydraulic Products, Service and Expertise, Worldwide

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT

Radial piston pumps type R and RG

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Chapter 5: Flow Valves

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

FP12 FERRA SERIES HEAVY DUTY GEAR PUMP

Table of Contents. M Series Variable Displacement Piston Pumps

Axial Piston Fixed Displacement Motor A2FM

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

PUMP AND MOTOR DIVISION

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Dual Path Mobile Pump

H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions

PVM Piston Pumps Service Manual

HYDRAULIC MOTORS Concentric AB

Vickers. Piston Pumps

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

Vickers PVM Piston Pumps

Fixed displacement vane pumps

PVH131/141 Variable Displacement Piston Pump - 11 Design

Highly flexible couplings


Series 40 Axial Piston Motors. Technical Information

Unit 24: Applications of Pneumatics and Hydraulics

220 Series Piston Pump Typical Applications Features and Benefits

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Vickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment

HMC Series Dual Displacement Staffa Motor

Unit 24: Applications of Pneumatics and Hydraulics

Rickmeier Solutions. Gear pumps for superior Lubrication

PVQ 40-B2/M2 * *** - ** * * - 10 C** *** *** * - 10/11/12/20 PVQ 45-B2/M2 * *** - ** * * - 10 C**

Machine Design II Prof. K.Gopinath & Prof. M.M.Mayuram. Module 2 - GEARS. Lecture 17 DESIGN OF GEARBOX

Check Valves Valve locator

Axial Piston Variable Pump KVA

Vane Pump & Motor Design Guide

ZF 301 A. Marine Propulsion Systems

Internal gear pump PGF Series 2X and 3X

Variable Displacement Pump A7VO

Quiz On Information Learned From Chapter 1

Design and Modeling of Fluid Power Systems ME 597/ABE 591 Lecture 5

ZF 220 A 10 Down angle, direct mount marine transmission.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

H1 Bent Axis Variable Displacement Motors Size 060 Size 080 Size 110 Size 160. Technical Information

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

Pipe Cutting and Beveling Clamshells

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE / for open circuits

1.Booklet. Hydraulic Motors. General Purpose MotorsR Series

W900 SERIES HYDRAULIC PUMP

ZF 286 A 7 Down angle, direct mount marine transmission.

ZF 85 IV. Marine Propulsion Systems

High Pressure Gear Motors KM 1

AXIAL PISTON-PRESSURE EXCHANGER DEVELOPMENT PROGRAM. 1.0 Abstract

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

ZF W325 Vertical offset, direct mount marine transmission.

Hydraulic Control Solutions

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps


2/2 and 3/2 Way Size 6 Seat Valves

PART 2 FORKLIFT HYDRAULIC SYSTEM

PLQE. The base of the economy gearboxes with square output flange. Economy Line. Formerly PLE

Transfer Gear Pumps KF

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

Axial Piston Variable Pump A10VSO

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

15/40/80CN Series Medium Pressure Filters

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Rotary actuators Rotary wing drives Series RAK. Brochure

ZF W320 Vertical offset, direct mount marine transmission.

Tool Holder Catalog INDEX ABC VDI 25 LL /Rö

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Pressure Relief and Regulating Valves

High Torque Vane Motors MV015, MV037, MV057, MV125

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

300 Series PA Pump and Cooler Assemblies

Rules for Classification and Construction Additional Rules and Guidelines

Transcription:

Hydraulic Motor/Pump Series F11/F12 Fixed Displacement parker.com/pmde

Series F11/F12 Torque (M) M = D x p x η hm 63 [Nm] Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5 psi 1 l...0.264 US gallon 1 cm 3...0.061 cu in 1 mm... 0.039 in 1 C... 5 / 9 ( F-32) 1 kw... 1.34 hp Basic formulas for hydraulic motors Flow (q) D x n q = 1000 x η [l/min] v D - displacement [cm 3 /rev] n - shaft speed [rpm] η v - volumetric efficiency p - differential pressure [bar] (between inlet and outlet) η hm - mechanical efficiency η t - overall efficiency (η t = η v x η hm ) Power (P) q x p x η P = t [kw] 600 Basic formulas for hydraulic pumps Flow (q) D x n x η v q = 1000 [l/min] Torque (M) M = D x p 63 x η hm Power (P) q x p P = 600 x η t [kw] [Nm] D - displacement [cm 3 /rev] n - shaft speed [rpm] η v - volumetric efficiency p - differential pressure [bar] (between inlet and outlet) η hm - mechanical efficiency η t - overall efficiency (η t = η v x η hm ) Conversion factors 1 lb... 0.454 kg 1 lbf...4.448 N 1 lbf ft...1.356 Nm 1 psi...0.068948 bar 1 US gallon... 3.785 l 1 cu in...16.387 cm 3 1 in... 25.4 mm 1 F... 9 / 5 C + 32 1 hp...0.7457 kw WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Offer of Sale Please contact your Parker representation for a detailed Offer of Sale. 2 Parker Hannifin

Content Series F11/F12 General product information General product information General information and design, Bearing life, F11/F12 Fan motors, Pages 4-7 F11/F12 in saw motor applications, Parker Power Boost Series F11 F11 Bent axis piston pump/motor with fixed displacement Pages 8-38 1 2 Series F12 F12 Bent axis piston pump/motor with fixed displacement Pages 39-59 3 Accessories Accessories Flushing valves, FV13 flushing valve block, Integrated pressure relief valve, SR pressure Pages 60-68 relief/anticavitation valve block, SV pressure relief valve block, Speed sensor, BLA Boost units Installation and start up information Installation and start up information F11, F12 Pages 69-71 4 5 3 Parker Hannifin

General Information Series F11/F12 Series F11 F11 is a bent-axis, fixed displacement motor/pump. It can be used in numerous applications in both open and closed loop circuits. The F11 series is available in sizes 5, 6, 10, 12, 14 and 19 cc (0.3 to 1.16 cu in/rev). F11 Features Max intermittent pressure up to 420 bar (6090 psi) and continuous operating pressure up to 350 bar (5075 psi) Thanks to low weight pistons and a compact design of the rotating parts, the F11 tolerates very high speeds, up to 14000 rpm CETOP, ISO, SAW and SAE versions Series F12 F12 is a bent-axis, fixed displacement motor/pump. It can be used in numerous applications in both open and closed loop circuits. The F12 series is available in sizes 30, 40, 60, 80, 90, 110, 125, 152, 162, 182 and 250 cc (1.83 to 14.8 cu in/rev). F12 Features Max intermittent pressure up to 480 bar (6960 psi) and continuous operating pressure up to 420 bar (6090 psi) The 7 or 9 piston design provides high start-up torque and smooth motor operation ISO, CETOP, Cartridge and SAE versions General Features The laminated piston ring offers important advantages such as unbeatable efficiency and thermal shock resistance High allowable speeds and operating pressures means high output power The unique piston locking, timing gear and bearing set-up as well as the limited number of parts add up to a very robust design with long service life and, above all, proven reliability. The 40 angle between shaft and cylinder barrel allows for a very compact, lightweight motor/ pump. Small envelop size and a high power-to-weight ratio The motor version has highly engineered valve plates for high speed and low noise The pump version has highly engineered valve plates for increased self priming speed and low noise, available with left and right hand rotation. The F11's and F12's have a simple and straight-forward design with very few moving parts, making them very reliable motors/pumps. Our unique timing gear design synchronizes shaft and cylinder barrel, making the F11/F12 very tolerant to high 'G' forces and torsional vibrations. Heavy duty roller bearings permit substantial external axial and radial shaft loads. 4 Parker Hannifin

Technical information Bearing life General information Bearing life can be calculated for that part of the load/ life curve (shown below) that is designated 'Bearing fatigue'. 'Rotating group fatigue and wear' and 'Other' caused by material fatigue, fluid contamination, etc. should also be taken into consideration when estimating the service life of a motor/pump in a specific application. Bearing life calculations are mainly used when comparing different frame sizes. Bearing life, designated B 10 (or L 10 ), is dependent of system pressure, operating speed, external shaft loads, fluid viscosity in the case, and fluid contamination level. The B 10 value means that 90% of the bearings survive, at a minimum, the number of hours calculated. Statistically, 50% of the bearings will survive at least five times the B 10 life. Life expectancy (logarithmic scale) Other causes Bearing fatigue Series F11/F12 Required information When requesting a bearing life calculation from Parker Hannifin, the following information (where applicable) should be provided: - A short presentation of the application - F11 or F12 size and version - Duty cycle (pressure and speed versus time at given displacements) - Low system pressure - Case fluid viscosity - Life probability (B 10, B 20, etc.) - Operating mode (pump or motor) - Direction of rotation (L or R) - External shaft loads (Forces, Gear, Belt, Cardan or none) For forces please provide: - Axial load, Fixed radial load, Bending moment, Rotating radial load and distance flange to radial load. For Gear please provide: - Pitch diameter, Pressure angle, Spiral angle, Distance flange gearwheel (mid) and Gearwheel spiral direction (R or L). For Belt please provide: - Pretension, Coefficient of friction, Angle of contact, Distance flange pulley (mid) and Diameter pulley. For Cardan please provide: - Shaft angle, Distance flange first joint and distance between joints - Angle of attack (α) as defined below 1 Rotating group fatigue and wear 170 190 System pressure Bearing_life_DE.eps Hydraulic unit life versus system pressure. Leif A./020201 F α Bearing life calculation An application is usually governed by a certain duty or work cycle where pressure and speed vary with time during the cycle. In addition, bearing life depends on external shaft forces, fluid viscosity in the case and fluid contamination. Parker Hannifin has a computer program for calculating bearing life and will assist in determining F11 or F12 motor/pump life in a specific application. The direction (α) of the F12_shaft_loads.EPS radial is positive in the direction of rotation as shown. Leif A./020204 To obtain maximum bearing life, the radial load should, in most cases, be located between 170 and 190. 5 Parker Hannifin

Technical information Series F11/F12 F11/F12 Fan motors F11/F12 motors, in frame sizes -5 to -40 cc (0.3 to 2.44 cu in/rev), are common in Fan applications. Some typical options are, built in check valve, pressure relief valve, cartridge flange and tapered shaft (refer to the schematic to the right). The fan motor can be operated at very high speeds without reliability problems. The fan is usually installed directly on the motor shaft without additional bearing support. The F11/F12 has up to 95% overall efficiency which reduces the diesel consumption and minimizes the cooling demand. Main port B Main port A Built -in anti cavitation valve Alternative drain port D Drain port C Type V Tapered shaft Fan motor circuit Because of the built-in anti cavitation valve, either left hand (L) or right hand (R) rotation must be specified when ordering the motor. When the pump flow to the motor is shut off and the motor is operating at very high speeds, it is important that sufficient return port back pressure is available (port B in the schematic to the right). The anti cavitation valve will then open and direct flow to the motor inlet port. If the inlet pressure is insufficient, motor cavitation will be experienced. In an open circuit, back pressure can be created by a counter pressure valve installed in the return line; preferably, it should be pilot operated to minimize power losses. A back pressure of about 10 bar is sufficient in most applications. For more drawings illustrating motors with make-up valve, see chapters 2, F11 and 3, F12. For more info about integrated pressure relief valves, see page 63. Fan motor (F11-10 left hand rotated shown). Port A Port B Port C/D Schematic Fan motor Fan_motor_schem.eps with anti cavitation valve Leif A./020204 Example of ordering code F11-010-MB-CV-K-000-MUVL-00 MUVL = Make up/anti cavitation valve, counter clockwise rotation MUVR = Make up/anti cavitation valve, clockwise rotation 6 Parker Hannifin

Technical information F11/F12 in saw motor applications Series F11/F12 motors have proven suitable for demanding applications such as chain saws. Primarily due to the 40 bent-axis design, spherical pistons (with laminated piston rings) and gear synchronization, very high speeds are permissible. Not even low temperatures at start-up affect reliability. Because of the built-in anti cavitation valve, either left hand (L) or right hand (R) rotation must be specified when ordering the motor. When the pump flow to the motor is shut off and the motor is operating at very high speeds, it is important that sufficient return port back pressure is available. The anti cavitation valve will then open and direct flow to the motor inlet port. If the inlet pressure is insufficient, motor cavitation will be experienced. To further enhance the saw function and, at the same time, reduce weight, cost and installation dimensions, a specific saw motor has been developed (frame sizes F11-6, -10, -12, -14 and -19; refer to the illustration to the right) which is specifically dedicated to bar saws. The motor allows the saw bar bearings to be mounted directly on the motor housing, and the sprocket installs on the motor shaft without additional bearings. Series F11/F12 Chain sprocket mounted directly on the shaft F11 with built-in Make up/anti cavitation valve Saw chain Protective cover Saw bar supported directly on the motor flange Feed cylinder Saw bar Chain saw F11_saw_motor_install.eps installation (example; F11-10 shown) Leif A./020204 1 Parker Power Boost A high speed F11 or F12 motor could be optimized with a Power Boost, which means less fluid friction and oil compression. This can reduce power losses by up to 5 kw. The improved efficiency generates less heat, reducing the need for cooling and consequently improves fuel consumption. Parker Power Boost is available for size F11-006, -010, -012, -014, -019 and F12-030. When to order a motor with Power Boost it is to be specified with a B in last field in model code. Ex below. F11-019-SB-CS-K-000-MUVL-B0 7 Parker Hannifin

Content Series F11 F11 Content Page Specifications...9 Efficiency...10 Noise level...10 Selfpriming speed and required inlet pressure...11 Ordering codes F11-CETOP...12 F11-ISO...13 F11-SAE...14 -CETOP F11-005...15 F11-006, -010...16 F11-012...18 F11-014...20 F11-019...22 -ISO F11-006, -010...24 F11-012...26 F11-014...28 -SAE F11-006, -010...30 F11-012...32 F11-014...34 F11-019...36 8 Parker Hannifin

Specifications Series F11 Frame size F11-005 -006-010 -012-014 -019 Displacement [cm 3 /rev] 4.9 6.0 9.8 12.5 14.3 19.0 [cu in/rev] 0.30 0.37 0.60 0.76 0.87 1.16 Operating pressure max intermittent 1) [bar] 420 420 420 420 420 420 [psi] 6 000 6 000 6 000 6 000 6 000 6 000 max continuous [bar] 350 350 350 350 350 350 [psi] 5 000 5 000 5 000 5 000 5 000 5 000 Motor operating speed [rpm] max intermittent 1) 14 000 11 200 11 200 10 300 9 900 8 900 max continuous 3) 12 800 10 200 10 200 9 400 9 000 8 100 min continuous 50 50 50 50 50 50 Max pump selfpriming speed 2) L or R function; max [rpm] 4 600 4 200 3 900 3 900 3 500 Motor input flow max intermittent 1) [l/min] 69 67 110 129 142 169 [gpm] 18.2 17.7 29.1 34.1 37.5 44.6 max continuous [l/min] 63 61 100 118 129 154 [gpm] 16.6 16.1 26.4 31.2 34.1 40.7 Drain temperature 3), max [ C] / [ F] 115/239 115/239 115/239 115/239 115/239 115/239 min [ C] / [ F] -40/-40-40/-40-40/-40-40/-40-40/-40-40/-40 Theoretical torque at 100 bar [Nm] 7.8 9.5 15.6 19.8 22.7 30.2 [lbf ft] 5.8 7.0 11.5 14.6 16.8 22.3 Mass moment of inertia (x10-3 ) [kg m 2 ] 0.16 0.39 0.39 0.40 0.42 1.1 (x10-2 ) [lbft 2 ] 0.38 0,92 0.92 0.95 1.00 2.61 Weight [kg] 4.7 7.5 7.5 8.2 8.3 11 [lb] 10.3 16.5 16.5 18.0 18.8 24 2 1) Intermittent: max 6 seconds in any one minute. 2) Selfpriming speed valid at sea level. Find more info on page 11 3) See also installation information. Page 69 9 Parker Hannifin

Technical information Efficiency Because of its high overall efficiency, driving a motor/ pump from series F11 requires less fuel or electric power. Also, it allows the use of a small reservoir and heat exchanger, which in turn reduce cost, weight, and installation size. The diagrams to the right show volumetric and mechanical efficiencies of an F11-5 motor. F11-19 motors can be equipped with Power Boost which in high speed applications can decrease the mechanical losses by up to 15%, see page 7. Contact Parker Hannifin for efficiency information on a particular F11 frame size that is being considered. Series F11 [%] Volumetric efficiencies 100 p [bar] 98 96 94 300 200 92 90 1000 2000 3000 4000 5000 Speed [rpm] Mechanical efficiencies [%] 100 p [bar] 98 96 94 300 200 92 90 1000 2000 3000 4000 5000 Speed [rpm] Noise level Series F11 feature low noise levels from low to high speeds and pressures. The noise level is measured in a semi-anechoic room, 1 m behind the unit. As an example, the diagram to the right shows the noise level of an F11-005. The noise level for a particular motor/pump may vary ±2 db(a) compared to what is shown in the diagram. NOTE: Noise information for F11/F12 frame sizes are available from Parker Hannifin. Noise level [db(a)] 80 75 70 65 60 55 50 5000 rpm 3000 rpm 1000 rpm 1450 2000 3000 4000 5000 5800 Pressure [psi] 10 Parker Hannifin

Technical information Selfpriming speed and required inlet pressure Series F11 In pump applications, the F11 with function L (counter clockwise rotation) or R (clockwise rotation) is normally used. The L and R (pump) provide the highest self priming speeds (see table) as well as the lowest noise level. The M and H (motor) function can also be used as a pump, in either direction, but at a lower self priming speed. Operating above the self priming speed (refer to Diagram 1) requires increased inlet pressure. As an example, at least 1.0 bar is needed when operating the F11-19-M as a pump at 3500 rpm. An F11 used as a motor (e.g. in a hydrostatic transmission), may sometimes operate as a pump at speeds above the selfpriming speed; this requires additional inlet pressure. Insufficient inlet pressure can cause pump cavitation resulting in greatly increased pump noise and deteriorating performance. Series F11 Function L or R M H F11-5 4600 3800 3200 F11-6 3100 F11-10 4200 3100 2700 F11-12 3900-3000 F11-14 3900-3000 F11-19 3500 Inlet_pressure_gauge.eps 2400 2100 Leif A./020204 Inlet pressure gauge 2 Inlet pressure [psi] 29 25 F11 Motor F11-019 F11-012/014 F11-010 F11-005 Inlet pressure [psi] 29 25 F11 Pump F11-019 F11-012/014 F11-010 F11-005 20 20 15 15 10 10 5 5 0 0 2.18 psi vacuum 2.18 psi vacuum -5 2000 3000 4000 5000 6000 7000 8000 9000-5 2000 3000 4000 5000 6000 7000 8000 9000 Selfpriming speed [rpm] Diagram 1. Min required inlet pressure for Motor. Selfpriming speed [rpm] Diagram 2. Min required inlet pressure for Pump. The inlet pressure can be charged by external pump, pressurized reservoir or using BLA Boost unit Find more info about the BLA unit at page 68. 11 Parker Hannifin

Ordering codes Series F11 F11 F11-CETOP Frame size Function Main ports Mounting flange Shaft seal Shaft Version number Option page 6 Option page 7, 67 Frame size Code Displacem. (cm 3 /rev) Displacem. (cu in/rev) 005 4.9 0.30 006 6.0 0.37 010 9.8 0.60 012 12.5 0.76 014 14.3 0.87 019 19.0 1.16 Frame size 5 6 10 12 14 19 Code Function M Motor x x x - - x Q Motor, low noise x - x x x x S Motor, high speed - - (x) (x) (x) (x) H Motor, high pressure (x) - (x) - - (x) R Pump, clockwise rot'n (x) - (x) (x) (x) (x) L Pump, counter clockw. (x) - (x) (x) (x) (x) For other versions, contact Parker Hannifin Frame size 5 6 10 12 14 19 Code Main ports B BSP threads x x x x x x U SAE, UN threads (x) (x) (x) (x) (x) (x) Version number (assigned for special versions) Frame size 5 6 10 12 14 19 Code Option 0000 Standard x x x x x x MUVR Make up/anti - - (x) (x) (x) (x) cavitation valve clockwise rotation MUVL Make up/anti cavitation valve counter clockwise rotation - - (x) (x) (x) (x) Frame size 5 6 10 12 14 19 Code Shaft* K Metric key x x x x x x J Metric key (x) (x) (x) (x) - - P Metric key - - - - (x) - A Spline, DIN 5480 - (x) (x) (x) - - D Spline, DIN 5480 x x x x x x S Spline, SAE (x) - - - - - V Tapered shaft - (x) (x) (x) (x) (x) *See also dimensional drawings on pages 15-23. Frame size 5 6 10 12 14 19 Code Mounting flange C CETOP flange x x x x x x W Saw motor flange - (x) (x) (x) (x) (x) Frame size 5 6 10 12 14 19 Code Shaft seal N NBR, low pressure (x) (x) (x) - - (x) V FPM, high pressure, x x x x x x high temperature S PTFE, high speed - (x) (x) (x) (x) (x) x: Available (x): Optional : Not available Frame size 5 6 10 12 14 19 Code Option 00 Standard x x x x x x P_ Prepared for speed sensor - (x) (x) (x) (x) (x) B_ Power Boost and Prepared - (x) (x) (x) (x) (x) for speed sensor _T Painted Black (x) (x) (x) (x) (x) (x) 12 Parker Hannifin

Ordering codes Series F11 F11 F11-ISO Frame size Function Main ports Mounting flange Shaft seal Shaft Version number Option page 6 Option page 7, 67 Frame size Code Displacem. (cm 3 /rev) Displacem. (cu in/rev) 006 6.0 0.37 010 9.8 0.60 012 12.5 0.76 014 14.3 0.87 Frame size 6 10 12 14 Code Function M Motor x x - - Q Motor, low noise - x x x S Motor, high speed - (x) (x) (x) H Motor, high pressure - (x) - - R Pump, clockwise rot'n - (x) (x) (x) L Pump, counter clockw. - (x) (x) (x) For other versions, contact Parker Hannifin Version number (assigned for special versions) Frame size 6 10 12 14 Code Option 0000 Standard x x x x MUVR Make up/anti - (x) (x) (x) cavitation valve clockwise rotation MUVL Make up/anti cavitation valve counter clockwise rotation - (x) (x) (x) 2 Frame size 6 10 12 14 Code Main ports F Metric threads - x x x B BSP threads x (x) (x) (x) M Side ports, metric - (x) (x) (x) Frame size 6 10 12 14 Code Mounting flange I ISO flange x x x x Frame size 6 10 12 14 Code Shaft* K Metric key x x x x J Metric key (x) (x) (x) - P Metric key - - - (x) A Spline, DIN 5480 (x) (x) (x) - D Spline, DIN 5480 x x x x V Tapered shaft (x) (x) (x) (x) *See also dimensional drawings on pages 25-29. Frame size 6 10 12 14 Code Shaft seal N NBR, low pressure (x) (x) - - V FPM, high pressure, x x x x high temperature S PTFE, high speed (x) (x) (x) (x) Frame size 6 10 12 14 Code Option 00 Standard x x x x P_ Prepared for speed sensor (x) (x) (x) (x) B_ Power Boost and Prepared (x) (x) (x) (x) for speed sensor _T Painted Black (x) (x) (x) (x) 13 Parker Hannifin

Ordering codes Series F11 F11 F11-SAE Frame size Function Main ports Mounting flange Shaft seal Shaft Version number Option page 6 Option page 7, 65 Frame size Code Displacem. (cm 3 /rev) Displacem. (cu in/rev) 006 6.0 0.37 010 9.8 0.60 012 12.5 0.76 014 14.3 0.87 019 19.0 1.16 Frame size 6 10 12 14 19 Code Function M Motor x x - - x Q Motor, low noise - x x x x S Motor, high speed - (x) (x) (x) (x) H Motor, high pressure - (x) - - (x) R Pump, clockwise rot'n - (x) (x) (x) (x) L Pump, counter clockw. - (x) (x) (x) (x) For other versions, contact Parker Hannifin Frame size 6 10 12 14 19 Code Main ports U SAE, UN threads x x x x x B BSP threads (x) (x) (x) (x) (x) Version number (assigned for special versions) Frame size 6 10 12 14 19 Code Option 0000 Standard x x x x x MUVR Make up/anti - (x) (x) (x) (x) cavitation valve clockwise rotation MUVL Make up/anti cavitation valve counter clockwise rotation - (x) (x) (x) (x) Frame size 6 10 12 14 19 Code Shaft* T SAE key - - - x x S SAE spline x x x x x K Metric key x x x x x J Metric key (x) (x) (x) - - P Metric key - - - (x) - V Tapered shaft (x) (x) (x) (x) (x) *See also dimensional drawings on pages 31-37. Frame size 6 10 12 14 19 Code Mounting flange S SAE flange x x x x x Frame size 6 10 12 14 19 Code Shaft seal N NBR, low pressure (x) (x) - - (x) V FPM, high pressure, x x x x x high temperature S PTFE, high speed (x) (x) (x) (x) (x) x: Available (x): Optional : Not available Frame size 6 10 12 14 19 Code Option 00 Standard x x x x x P_ Prepared for speed sensor (x) (x) (x) (x) (x) B_ Power Boost and Prepared (x) (x) (x) (x) (x) for speed sensor _T Painted Black (x) (x) (x) (x) (x) 14 Parker Hannifin

Series F11 F11-5 (CETOP versions) 3.31 max 2.56 Main port A (BSP 1/2 ) 1.50 Main port B (BSP 1/2 ) 0.20 1.87 Approx. center of gravity Drain port D (BSP1/4 ) 2 4.47 0.98 Drain port C (BSP1/4 ) 5.28 max 3.48 2.13 0,51 0.31 R 0.03 R 0.02 0.35 1.57 Flange C Key 6x6x30 (0.24x0.24x1.18 metric key) 0.20 M6 ; 0.47deep 0.81 Type K key shaft Ø0.7090 Ø0.7085 Main port A 3/4"-16 UNF O-ring boss; SAE J514d Ø3.1496 Ø3.1514 Main port B 3/4"-16 UNF O-ring boss; SAE J514d Ø0.43 (x2) Ø0.80 2.09 40 3.78 max Main ports Code U Drain port C 9/16"-18 UNF O-ring boss; SAE J514d 3.94 Ø5.0 max Type C mounting flange 0.35 0.71 1.38 1.10 Ø0.86 0.79 W18x1,25x13x9g Type D spline shaft (DIN 5480) Type S spline shaft (13T16/32 DP) F11_5_install.eps 15 Parker Hannifin Leif A./031008

Series F11 F11-006, -010 (CETOP versions) 3.70 max 3.11 Main port A (BSP 3/4 ) 1.81 Main port B (BSP 3/4 ) 0.43 2.09 Approx. center of gravity Drain port D (BSP3/8 ) 5.24 1.18 Drain port C (BSP3/8 ) 6.14 max 3.98 2.48 0.55 0.31 R0.02 0.35 Flange C Ø3.9370 Ø3.9349 2.24 Ø0.51 (x2) 40 4.57 max 4.92 Ø5.98 max Type C mounting flange 16 Parker Hannifin

F11-006, -010 (CETOP versions) Series F11 Shaft options Ø0.91 3.74 2.68 1.73 Speed sensor (optional) 25 Key 6x6x35 R0.03 (0.24x0.24x1.38 (28) 1.97 0.28 metric key) 2 6.14 max (5.87) Type K key shaft (Std) M6 ; 0.47 deep Ø0.7878 Ø0.7872 0.89 Make up/anti cavitation valve (MUVL or MUVR optional; clockwise rotation shown). 1.65 0.14 Type J key shaft (Opt.) 1.10 Key 8x7x35 (0.31x0.28x1.38 metric key) M10 ; 0.63 deep Ø0.9844 Ø0.9841 (2.17) B CCW CW 0.87 A Spline shaft D W20x1.25x14x9g; DIN 5480 1.02 Spline shaft A W 25x1.25x18x9g DIN 5480 1.0 2.03 0.91 Tapered key shaft "V" SAE J744 22-3 (B) 1.69 Ø0.16 0.25 5/8 UNF-2A 0.08 0.13 17 Parker Hannifin

Series F11 F11-012 (CETOP versions) Main port B (BSP 3/4 ) Main port A (BSP 3/4 ) 3.98 1.81 4.02 2.83 2.09 max Drain port D (BSP3/8 ) 1.18 (1.26) Drain port D (BSP3/8 ) 5.24 6.14 max 3.98 0.55 (x2) 0.31 0.35 1.97 Flange C Ø3.9370 Ø3.9349 B A CCW CW 40 (x4) 4.57 max Ø0.51 (x2) 4.92 5.98 max 18 Parker Hannifin

Series F11 F11-012 (CETOP versions) Shaft options Ø0.91 (32) 4.02 2.83 (1.77) Speed sensor (optional) 25 1.97 0.28 Key 6x6x35 (0.24x0.24x1.38 metric key) 2 6.14 max (5.87) Type K key shaft (Std) 0.89 M6 ; 0.47 deep Ø0.7878 Ø0.7872 1.65 0.14 Key 8x7x35 (0.31x0.28x1.38 metric key) M10 ; 0.63 deep Make up/anti cavitation valve (MUVL or MUVR optional; clockwise rotation shown) Type J key shaft (Opt.) 1.10 Ø0.9844 Ø0.9841 (2.32) B CCW CW A 0.87 Spline shaft D W20x1.25x14x9g; DIN 5480 1.02 Spline shaft A W 25x1.25x18x9g DIN 5480 0.35 1.0 2.03 0.91 Tapered key shaft "V" SAE J744 22-3 (B) 1.69 Ø0.16 0.25 5/8 UNF-2A 0.08 0.13 19 Parker Hannifin

Series F11 F11-014 (CETOP versions) Main port A (BSP 3/4 ) 4.02 Main port B (BSP 3/4 ) 4.02 2.09 1.81 (1.26) 1.18 Drain port D (BSP3/8 ) Drain port C (BSP3/8 ) 5.24 6.18 max 3.94 0.31 0.55 0.37 R0.02 Flange C Ø3.9370 Ø3.9349 Ø0.51 (x2) B A CCW CW 39 (x4) 4.49 4.92 5.91 Type C mounting flange 20 Parker Hannifin

F11-014 (CETOP versions) Series F11 Shaft options Ø1.06 6.18 max (1.26) 4.02 2.83 25 1.77 Speed sensor (optional) 5.87 R0.03 1.65 Type K key shaft 0.14 1.10 M8 ; 0.63 deep Ø0.9846 Ø0.9841 0.31 Key 8x7x35 (0.31x0.28x1.38 metric key) 2 Ø1.06 1.97 0.28 Key 6x6x35 (0.24x0.24x1.38 metric key) Make up/anti cavitation valve (MUVL or MUVR optional; clockwise rotation shown) Type P key shaft (Opt.) 0.89 M6 ; 0.47 deep Ø0.7878 Ø0.7872 2.32 B A CCW CW 1.02 Spline shaft D W 25x1.25x18x9g DIN 5480 1.0 2.03 0.91 1.69 Ø0.16 0.25 5/8 UNF-2A 0.08 0.13 Tapered key shaft "V" SAE J744 22-3 (B) 21 Parker Hannifin

Series F11 F11-019 (CETOP version) 4.49 max 3.46 2.48 Main port A (BSP 3/4 ) 2.13 Main port B (BSP 3/4 ) 0.43 Approx. center of gravity 1.14 Drain port C (BSP3/8 ) 6.50 max Drain port D (BSP3/8 ) 5.43 2.28 0.63 3.94 0.91 0.98 Flange C R0.05 max 0.39 Ø4.4094 Ø4.4073 3.43 Ø0.55 (x2) 45 4.96 5.51 Ø6.77 max Type C mounting flange 22 Parker Hannifin

Series F11 F11-019 (CETOP version) Shaft options 1.06 4.33 5.91 25 Speed sensor (optional) Ø1.11 2 1.30 1.65 0.14 Key 8x7x35 (0.31x0.28x1.38 metric key) 6.42 max (5.91) Type K key shaft 1.10 M8 ; 0.63 deep Ø0.9846 Ø0.9841 Make up/anti cavitation valve (MUVL or MUVR optional; clockwise rotation shown) 1.10 Spline shaft D W 25x1.25x18x9g DIN 5480 2.40 CCW CW 2.56 1.0 2.03 0.91 1.69 Ø0.16 0.25 5/8 UNF-2A 0.08 0.13 Tapered key shaft "V" SAE J744 22-3 (B) 23 Parker Hannifin

Series F11 F11-006, -010 (ISO versions) Main port A M22x1.5 0.63 deep min ISO 9974-1 3.74 (max) 1.81 Main port B M22x1.5 0.63 deep min ISO 9974-1 3.11 2.09 Drain port M12x1.5 0.55 deep min ISO 9974-1 1.18 Drain port M12x1.5 0.55 deep min ISO 9974-1 0.47 4.84 5.71 max 3.64 0.28 R0.02 0.73 max 0.78 Flange I (ISO 3019/2) Ø3.1496 Ø3.1478 0.41 (x4) Ø0.35 (x4) B A ccw cw R0.18 (x4) (Ø4.06) 2.87 3.74 24 Parker Hannifin

Series F11 F11-006, -010 (ISO versions) 3.74 2.68 1.73 Speed sensor (optional) 25 Shaft options Ø0.91 1.10 B 1.97 Key 6x6x35 (0.24x0.24x1.38 metric key) 2 5.71 max (5.87) Type K key shaft (Std) 0.28 M6 ; 0.47 deep Ø0.7878 Ø0.7872 0.89 Make up/anti cavitation valve (MUVL or MUVR optional; clockwise rotation shown) 1.65 0.14 Type J key shaft (Opt.) 1.10 Key 8x7x35 (0.31x0.28x1.38 metric key) M10 ; 0.63 deep Ø0.9844 Ø0.9841 2.17 B A ccw cw Side ports M (both sides) M22x1.5 14 deep min ISO 9974-1 Only for F11-010 2.68 0.87 Spline shaft D W20x1.25x14x9g; DIN 5480 1.10 1.02 Spline shaft A W 25x1.25x18x9g DIN 5480 1.0 2.03 Tapered key shaft "V" SAE J744 22-3 (B) 0.91 1.69 Ø0.16 0.25 5/8 UNF-2A 0.08 0.13 25 Parker Hannifin

Series F11 F11-012 (ISO versions) Main port A M26x1.5 0.63 deep min ISO 9974-1 3.98 1.81 Main port B M26x1.5 0.63 deep min ISO 9974-1 Drain port M16x1.5 0.47 deep min ISO 9974-1 4.02 2.09 1.18 5.79 max 4.84 3.54 0.28 0.47 0.77 R0.02 0.73 Flange I (ISO 3019/2) Ø3.1496 Ø3.1478 B A ccw cw 0.41 (x4) Ø0.35 (x4) R0.18 (x4) (Ø4.06) 2.87 3.74 26 Parker Hannifin

Series F11 F11-012 (ISO versions) Speed sensor (optional) 102 72 45 Shaft options Ø0.91 5.79 max (1.26) 5.47 1.97 0.28 Type K key shaft (Std) 0.89 Key 6x6x35 (0.24x0.24x1.38 metric key) M6 ; 0,47 deep Ø0.7878 Ø0.7872 2 Make up/anti cavitation valve (MUVL or MUVR optional; clockwise rotation shown) (2.32) B A Side ports M (both sides) M22x1.5 14 deep min ISO 9974-1 ccw 2.83 cw 1.65 Type J key shaft (Opt.) 0.87 0.14 1.10 Key 8x7x35 (0.31x0.28x1.38 metric key) M10 ; 0.63 deep Ø0.9844 Ø0.9841 Spline shaft D W20x1.25x14x9g; DIN 5480 (1.26) 1.10 Spline shaft A W 25x1.25x18x9g DIN 5480 1.0 2.03 0.91 Tapered key shaft "V" SAE J744 22-3 (B) 1.69 Ø0.16 0.25 5/8 UNF-2A 0.08 0.13 27 Parker Hannifin

Series F11 F11-014 (ISO versions) Main port A M26x1.5 0.63 deep min ISO 9974-1 3.98 Main port B M26x1.5 0.63 deep min ISO 9974-1 4.02 2.09 1.81 1.18 Drain port D M16x1.5 (depth 0.47; ISO 9974-1) Drain port C M16x1.5 (depth 0.47; ISO 9974-1) 0.47 4.84 5.79 max 3.54 0.73 0.83 0.26 R0.02 Flange I (ISO 3019/2) Ø3.1496 Ø3.1478 Ø0.35 (x4) 0.41 (x4) Ø0.35 (x4) B A CCW CW (Ø4.06) 2.87 3.74 Type I mounting flange (ISO 3019/2) 28 Parker Hannifin

Series F11 F11-014 (ISO versions) 4.02 2.83 1.77 Speed sensor (optional) Shaft options Ø1.06 (1.26) 25 2 5.79 max 5.47 1.65 0.14 Type K key shaft 1.10 Ø1.06 Key 8x7x35 (0.31x0.28x1.38 metric key) M8 ; 0.63 deep Ø0.9846 Ø0.9841 Make up/anti cavitation valve (MUVL or MUVR optional; clockwise rotation shown) (2.32) B A CCW CW 1.97 0.28 Type J key shaft (Opt.) Key 6x6x35 (0.24x0.24x1.38 metric key) M6 ; 0,47 deep Ø0.7878 0.89 Ø0.7872 Side ports M (both sides) M22x1.5 14 deep min ISO 9974-1 2.83 1.10 (1.26) 25 Spline shaft D W25x1.25x18x9g (DIN 5480) 1.0 2.03 0.91 Tapered key shaft "V" SAE J744 22-3 (B) 1.69 Ø0.16 0.25 5/8 UNF-2A 0.08 0.13 29 Parker Hannifin

Series F11 F11-006, -010 (SAE versions) Main port A 1 1 / 16-12 UN O-ring boss; SAE J514d 3.70 max 1.81 Main port B 1 1 / 16-12 UN O-ring boss; SAE J514d 3.11 2.09 Drain port 9 / 16-18 UNF O-ring boss; SAE J514d 1.18 Drain port 9 / 16-18 UNF O-ring boss; SAE J514d 5.24 6.14 max 4.02 R0.02 0.67 (x2) 0.37 Flange S size 101-2 SAE B SAE J744c Ø4.0000 Ø3.9980 Ø2.17 R2.36 (x2) 29 (x4) R0.55 (x4) CCW CW Ø0.57 (x2) 4.80 max 5.75 6.97 (max) 30 Parker Hannifin

F11-006, -010 (SAE versions) Series F11 Shaft options Ø0.91 3.74 2.68 1.73 25 0.31 2 (1.10) 1.97 0.28 Key 6x6x35 (0.24x0.24x1.38 metric key) 6.14 max (5.87) Speed sensor (optional) Type K key shaft (Std) M6 ; 0.47 deep Ø0.7878 Ø0.7872 0.89 0.31 1.65 0.14 Key 8x7x35 (0.31x0.28x1.38 metric key) Make up/anti cavitation valve (MUVL or MUVR optional; clockwise rotation shown) Type J key shaft (Opt.) 1.10 M10; 0.63 deep Ø0.9844 Ø0.9841 0.31 2.17 CCW CW 1.30 0.91 Type S spline shaft SAE B, 13T, 16/32 DP (SAE J498b, class 1; 30 involute spline; flat root, side fit) 1.0 2.03 Tapered key shaft "V" SAE J744 22-3 (B) 0.91 1.69 Ø0.16 0.25 5/8 UNF-2A 0.08 0.13 31 Parker Hannifin

Series F11 F11-012 (SAE versions) Main port A 1 1 / 16-12 UN O-ring boss; SAE J514d Main port B 1 1 / 16-12 UN O-ring boss; SAE J514d 3.98 1.81 4.02 2.09 Drain port 9 / 16-18 UNF O-ring boss; SAE J514d 1.18 Drain port D 9 / 16-18 UNF O-ring boss; SAE J514d 0.37 5.24 6.22 max 0.67 (x2) 0.31 Ø0.94 (x2) 4.02 Ø2.17 Ø4.0000 Ø3.9980 R 0.02 Flange S size 101-2 SAE B SAE J744c R 2.36 (x2) (2.28) B A ccw cw R 0.55 (x4) 29 (x4) Ø0.57 (x2) 4.80 5.75 6.85 max 32 Parker Hannifin

Series F11 F11-012 (SAE versions) Shaft options 4.02 2.83 1.77 Speed sensor (optional) Ø0.91 2 (1.26) 0.31 6.22 max 5.94 1.97 0.28 Key 6x6x35 (0.24x0.24x1.38 metric key) M6 ; 0.47 deep Type K key shaft (Std) 0.89 Ø0.7878 Ø0.7872 0.31 Make up/anti cavitation valve (MUVL or MUVR optional; clockwise rotation shown) 1.65 0.14 Type J key shaft (Opt.) 1.10 Key 8x7x35 (0.31x0.28x1.38 metric key) M10 ; 0.63 deep Ø0.9844 Ø0.9841 (2.28) B A ccw cw 0.31 1.30 0.91 Type S spline shaft SAE B, 13T, 16/32 DP (SAE J498b, class 1; 30 involute spline; flat root, side fit) 1.0 2.03 0.91 Tapered key shaft "V" SAE J744 22-3 (B) 1.69 Ø0.16 0.25 5/8 UNF-2A 0.08 0.13 33 Parker Hannifin

Series F11 F11-014 (SAE versions) Main port A 1 1 / 16-12 UN O-ring boss; SAE J514d 3.98 Main port B 1 1 / 16-12 UN O-ring boss; SAE J514d 4.02 2.09 1.81 1.18 Drain port D 9 / 16-18 UNF O-ring boss; SAE J514d Drain port C 9 / 16-18 UNF O-ring boss; SAE J514d 0.37 5.24 6.22 max 0.67 (x2) Ø0.94 (x2) 4.02 R 0.02 0.31 Ø3.15 Ø4.0000 Ø3.9980 4.72 B A CCW CW R 0.55 (x4) 29 (x4) Ø0.57 (x2) 5.75 6.85 (max) Type S mounting flange SAE 'B' ( SAE J744c) 34 Parker Hannifin

F11-014 (SAE versions) Series F11 Shaft options 4.02 2.83 1.77 Speed sensor (optional) 0.31 Ø1.06 2 (1.26) 25 1.50 0.09 Key ¼"x¼"x1¼" 6.22 max 5.94 Type T key shaft Size 25-1 (B B) (SAE J744c) 1.11 Ø80 5/16"-24 UNF-2B (depth 0.63) Ø1.0000 Ø0.9980 0.31 Make up/anti cavitation valve (MUVL or MUVR optional; clockwise rotation shown) (2.28) B A CCW CW 1.30 0.94 Type S spline shaft SAE B, 13T, 16/32 DP (SAE J498b, class 1; 30 involute spline; flat root, side fit) 1.0 2.03 0.91 Tapered key shaft "V" SAE J744 22-3 (B) 1.69 Ø0.16 0.25 5/8 UNF-2A 0.08 0.13 35 Parker Hannifin

Series F11 F11-019 (SAE version) 4.49 max 3.46 2.48 Main port A* (1 1 / 16 "-12) 2.13 Main port B* (1 1 / 16 "-12) 0.43 Approx. center of gravity Drain port D* ( 9 / 16 "-18) 1.14 6.10 Drain port C* ( 9 / 16 "-18) 7.13 max 2.91 0.31 0.67 4.61 0.38 Flange S R 0.03 Ø4.0000 Ø3.9980 Ø0.57 (x2) 30 4.84 R 0.55 5.75 Ø6.93 max Type S mounting flange SAE B (SAE J744c) * O-ring ports according to SAE J514d 36 Parker Hannifin

Series F11 F11-019 (SAE version) Shaft options 4.33 3.27 1.93 Speed sensor (optional) (25 ) Ø1.11 2 0.31 1.30 1.50 R 0.04 Key ¼"x¼"x1¼" 7.13 max 6.57 0.09 Type T key shaft SAE B-B (SAE J744c) 1.11 5 /16 "-24 UNF-2b (depth 0.63) Ø1.0000 Ø0.9980 Make up/anti cavitation valve (MUVL or MUVR optional; clockwise rotation shown) 0.31 2.40 2.56 ccw cw 1.30 Type S spline shaft SAE B, 13T, 16/32 DP (SAE J498b, class 1; 30 involute spline; flat root, side fit) 1.0 2.03 0.91 Tapered key shaft "V" SAE J744 22-3 (B) 1.69 Ø0.16 0.25 5/8 UNF-2A 0.08 0.13 37 Parker Hannifin

Notes Series F12 38 Parker Hannifin

Content Series F12 F12 3 Content Page Specifi cations...40 Effi ciency...41 Noise level...41 Selfpriming speed and required inlet pressure...42 Ordering codes F12-ISO...43 F12-Cartridge...44 F12-SAE...45 ISO F12-30, -40, -60, -80, -90, -110 and -125...46 F12-152, -162 and -182...48 Cartridge F12-30, -40, -60, -80, -90, -110 and -125...50 SAE F12-30, -40, -60, -80, -90, -110 and -125, 4 bolt fl ange...52 F12-152, -162 and -182...54 F12-250...56 F12-250 Options (SAE version)...57 F12-30, -40, and -60, 2 bolt fl ange...58 39 Parker Hannifin

Specifications Series F12 Frame size F12-030 -040-060 -080-090 -110-125 -152-162 -182-250 Displacement [cm 3 /rev] 30.0 40.0 59.8 80.4 93.0 110.1 125.0 149.8 163.1 179.8 242 Operating pressure [cu in/rev] 1.83 2.44 3.65 4.91 5.68 6.72 7.63 9.14 9.95 10.97 14.8 max intermittent 1) [bar] 480 480 480 480 420 480 480 480 480 480 420 [psi] 7 000 7 000 7 000 7 000 6 000 7 000 7 000 7 000 7 000 7 000 6000 max continuous [bar] 420 420 420 420 350 420 420 420 420 420 350 Motor operating speed [rpm] [psi] 6000 6000 6000 6000 5 000 6000 6000 6000 6000 6000 5000 max intermittent 1) 7300 6700 5800 5300 5000 4800 4600 4000 4000 4000 3000 max continuous 3) 6700 6100 5300 4800 4600 4400 4200 3700 3700 3700 2700 Max pump selfpriming speed 2) min continuous 50 50 50 50 50 50 50 50 50 50 50 L or R function; max [rpm] 3150 2870 2500 2300 2250 2200 2100 - - - 1500 Motor input flow max intermittent 1) [l/min] 219 268 347 426 465 528 575 608 648 728 726 [gpm] 57.9 70.8 91.7 112.5 122.8 139.5 151.9 144.5 171.2 192.3 191.8 max continuous [l/min] 201 244 317 386 428 484 525 547 583 655 653 [gpm] 53.1 64.5 83.7 102.0 113.1 127.9 138.7 144.5 154.0 173.0 172.5 Drain temperature 3), max [ C] 115 115 115 115 115 115 115 115 115 115 115 [ F] 239 239 239 239 239 239 239 239 239 239 239 min [ C] -40-40 -40-40 -40-40 -40-40 -40-40 -40 [ F] -40-40 -40-40 -40-40 -40-40 -40-40 -40 Theoretical torque at 100 bar [Nm] 47.6 63.5 94.9 127.6 147.6 174.8 198.4 241 257 289 384.1 Mass moment of inertia [lbf ft] 35.1 46.9 70.0 94.2 108.9 129.0 146.4 177.8 189.6 213.2 283.5 (x10-3 ) [kg m 2 ] 1.7 2.9 5 8.4 8.4 11.2 11.2 21 21 21 46 (x10-2 ) [lbft 2 ] 4.03 6.88 11.86 19.93 19.93 26.58 26.58 79.83 79.83 79.83 109.16 Weight [kg] 12 16.5 21 26 26 36 36 40 40 40 77 [lb] 26 36 46 57 57 79 79 88 88 88 170 1) Intermittent: max 6 seconds in any one minute. 2) Selfpriming speed valid at sea level. Find more info on page 42 3) See also installation information. Page 69 40 Parker Hannifin

Technical information Series F12 Efficiency Because of its high overall efficiency, driving a motor/ pump from series F12 requires less fuel or electric power. 100% Volumetric efficiencies 3000 psi Also, it allows the use of a small reservoir and heat exchanger, which in turn reduce cost, weight, and installation size. 90% 6000 psi The diagrams to the right show volumetric and mechanical efficiencies of an F12-030 motor. 80% F12-030 motors can be equipped with Power Boost which in high speed applications can decrease the mechanical losses by up to 15%, see page 7. 100% 0 1000 2000 3000 4000 Speed [rpm] Mechanical efficiencies 6000 psi 3 Contact Parker Hannifin for efficiency information on a particular F12 frame size that is being considered. 90% 80% 3000 psi 0 1000 2000 3000 4000 Speed [rpm] Noise level Series F12 feature low noise levels from low to high speeds and pressures. As an example, the diagram to the right shows the noise level of an F12-030 pump/motor. The noise level is measured in a semi-anechoic room, 1 m behind the unit. The noise level for a particular motor/pump may vary ±2 db(a) compared to what is shown in the diagram. Noise level [db(a)] 90 85 80 75 5000 rpm 3500 rpm Efficiency_F12_US_PC.eps Leif A./02-10-14 70 2000 rpm 65 NOTE: Noise information for F12 frame sizes are available from Parker Hannifin. 0 1000 2000 3000 4000 5000 Pressure [psi] Noise_F12_US_PC.eps Leif A./02-10-14 41 Parker Hannifin

Technical information Series F12 Selfpriming speed and required inlet pressure Series F12 When operating the F12 as a pump (with L or R valve plate) above the selfpriming speed, the inlet must be pressurized. Increased noise and deteriorating performance may otherwise be experienced. Diagrams 2 and 3 shows required pump inlet pressure vs. shaft speed. The F12 motor (type M valve plate) sometimes operates as a pump e.g. when used in a propel transmission and the vehicle is going downhill. Minimum required inlet pressure versus shaft speed is shown in the diagrams. The inlet pressure can be charged by external pump, pressurized reservoir or using BLA Boost unit. Find more info about the BLA unit at page 6. Inlet pressure F12 Pump [psi] F12-250-150-125 -110-90 -80-60 -40-30 29 25 20 15 10 5 0 2.18 psi vacuum -5 1000 2000 3000 4000 5000 Speed [rpm] Diagram 2. Min. required pump (F12-L or -R) inlet press. Inlet pressure F12 Motor [psi] F12-152-162-182 F12-250 -125-110 -90-80 -60-40 -30 29 25 20 15 10 5 0-5 2.18 psi vacuum 1000 2000 3000 Speed 4000 [rpm] Diagram 3. Min. required motor (F12-M) inlet pressure. 42 Parker Hannifin

Ordering codes Series F12 F12 F12-ISO Frame size Function Main ports Mounting flange Shaft seal Shaft Version number Option page 6, 61 Option page 7, 67 Frame size Code Displacem. (cm 3 /rev) Displacem. (cu in/rev) 030 30.0 1.83 040 40.0 2.44 060 59.8 3.65 080 80.4 4.91 090 93.0 5.68 110 110.1 6.72 125 125.0 7.63 152 149.8 9.14 162 163.1 9.95 182 179.8 11.11 Frame size 30 40 60 80 90 110 125 152 162 182 Code Function M Motor x x x x x x x x x x S Motor, high (x) (x) (x) - - - - (x) (x) (x) speed R Pump, (x) (x) (x) (x) (x) (x) (x) - - - clockwise rotation L Pump, (x) (x) (x) (x) (x) (x) (x) - - - counter clockwise rot'n For other versions, contact Parker Hannifin Frame size 30 40 60 80 90 110 125 152 162 182 Code Main ports F SAE 6000 psi x x x x x x x x x x flange D SAE 6000 psi - - - - - - - (x) (x) (x) Horizontal A SAE 6000 psi Axial - - - - - - - (x) (x) (x) K SAE 6000 psi Rear - - - - - - - (x) (x) (x) M SAE 6000 psi Side - - - - - - - (x) (x) (x) Frame size 30 40 60 80 90 110 125 152 162 182 Code Mounting flange I ISO flange x x x x x x x x x x F ISO 200 flange - - - - - - - x x x Frame size 30 40 60 80 90 110 125 152 162 182 Code Shaft* D DIN Spline, x x x x x x x x x x Standard A DIN Spline, - (x) - - - - - - - - Optional Z DIN Spline, (x) (x) (x) (x) (x) (x) (x) (x) (x) (x) Optional K Metric key, x x x x x x x x x x Standard J Metric key, - (x) - - - - - - - - Optional H DIN Spline, - - - - - - - (x) (x) (x) Optional G Metric key, - - - - - - - (x) (x) (x) Optional P Metric key, (x) - - - - - - (x) (x) (x) Optional V Tapered shaft (x) (x) (x) - - (x) (x) - - - *See also dimensional drawings on pages 46 and 48. Frame size 30 40 60 80 90 110 125 152 162 182 Code Option 0000 Standard x x x x x x x x x x L130 Flushing valve (x) (x) (x) (x) (x) - 1) - 1) - - - 1.3 mm orifice MUVR Make up/anti (x) - - - - - - - - - cavitation valve clockwise rotation MUVL Make up/anti (x) - - - - - - - - - cavitation valve counter clockwise rotation P R Pressure relief valve (x) (x) (x) - - - - - - - 2) clockwise rotation P L 2) Pressure relief valve counter clockwise rotation Version number (assigned for special versions) (x) (x) (x) - - - - - - - Frame size 30 40 60 80 90 110 125 152 162 182 Code Option 00 Standard x x x x x x x x x x P_ Prepared for speed (x) (x) (x) (x) (x) (x) (x) (x) (x) (x) sensor B_ Power Boost and (x) - - - - - - - - - Prepared for speed sensor _T Painted Black (x) (x) (x) (x) (x) (x) (x) (x) (x) (x) 3 x: Available (x): Optional : Not available 1) F12-110 and -125: Accessory valve block (page 62) 2) Pressure setting on page 63 Frame size 30 40 60 80 90 110 125 152 162 182 Code Shaft seal N NBR, low pressure (x) (x) (x) (x) (x) (x) (x) (x) (x) (x) V FPM, high pressure, x x x x x x x x x x high temperature S PTFE, high speed (x) - - - - - - - - - 43 Parker Hannifin

Ordering codes Series F12 F12 Frame size F12-Cartridge Function Main ports Mounting flange Shaft seal Shaft Version number Option page 6, 61 Option page 7, 67 Frame size Code Displacem. (cm 3 /rev) Displacem. (cu in/rev) 030 30.0 1.83 040 40.0 2.44 060 59.8 3.65 080 80.4 4.91 090 93.0 5.68 110 110.1 6.72 125 125.0 7.63 Frame size 30 40 60 80 90 110 125 Code Function M Motor x x x x x x x S Motor, high speed (x) (x) (x) - - - - For other versions, contact Parker Hannifin Frame size 30 40 60 80 90 110 125 Code Main ports F SAE 6000 psi flange x x x x x x x Frame size 30 40 60 80 90 110 125 Code Mounting flange C Cartridge x x x x x x x x: Available (x): Optional : Not available 1) F12-110 and -125: Accessory valve block (page 62) 2) Pressure setting on page 63 Version number (assigned for special versions) Frame size 30 40 60 80 90 110 125 Code Shaft* C DIN Spline, Std. x x x x x x x K Metric key, Option (x) - (x) (x) (x) (x) (x) J Metric key, Option - (x) - - - - - B Spline DIN 5480 - - (x) - - (x) (x) V Tapered shaft (x) (x) (x) - - (x) (x) *See also dimensional drawings on page 50. Frame size 30 40 60 80 90 110 125 Code Option 0000 Standard x x x x x x x L130 Flushing valve 1.3 mm (x) (x) (x) (x) (x) - 1) - 1) orifice MUVR Make up/anti (x) - - - - - - cavitation valve clockwise rotation MUVL Make up/anti (x) - - - - - - cavitation valve counter clockwise rotation P R Pressure relief valve (x) (x) (x) - - - - 2) clockwise rotation P L 2) Pressure relief valve counter clockwise rotation (x) (x) (x) - - - - Frame size 30 40 60 80 90 110 125 Code Option 00 Standard x x x x x x x P_ Prepared for speed sensor x (x) (x) (x) (x) x x B_ Power Boost and Prepared (x) - - - - - - for speed sensor _T Painted Black (x) (x) (x) (x) (x) (x) (x) Frame size 30 40 60 80 90 110 125 Code Shaft seal N NBR, low pressure (x) (x) (x) (x) (x) (x) (x) V FPM, high pressure, x x x x x x x high temperature S PTFE, high speed (x) - - - - - - 44 Parker Hannifin

Ordering codes Series F12 F12 F12-SAE Frame size Function Main ports Mounting flange Shaft seal Shaft Version number Option page 6, 61 Option page 7, 67 Frame size Code Displacem. (cm 3 /rev) Displacem. (cu in/rev) 030 30.0 1.83 040 40.0 2.44 060 59.8 3.65 080 80.4 4.91 090 93.0 5.68 110 110.1 6.72 125 125.0 7.63 152 149.8 9.14 162 163.1 9.95 182 179.8 11.11 250 242.0 14.76 Frame size 30 40 60 80 90 110 125 152 162 182 250 Code Function M Motor x x x x x x x x x x - S Motor, high (x) (x) (x) - - - - (x) (x) (x) - speed Q Motor - - - - - - - - - - x R Pump, (x) (x) (x) (x) (x) (x) (x) - - - (x) clockwise rotation L Pump, (x) (x) (x) (x) (x) (x) (x) - - - (x) counter clockwise rot'n For other versions, contact Parker Hannifin - - - - - - - x x x x - - - - - - - (x) (x) (x) - - - - - - - - (x) (x) (x) - - - - - - - - (x) (x) (x) - - - - - - - - (x) (x) (x) - Frame size 30 40 60 80 90 110 125 152 162 182 250 Code Main ports S SAE 6000 psi x x x x x x x - - - - flange U SAE UN (x) (x) (x) (x) (x) (x) (x) - - - - threads 4) F SAE 6000 psi flange 2) D SAE 6000 psi Horizontal 2) A SAE 6000 psi Axial 2) K SAE 6000 psi Rear 2) M SAE 6000 psi Side 2) Frame size 30 40 60 80 90 110 125 152 162 182 250 Code Mounting flange S SAE 4 bolt x x x x x x x x x x x R SAE 4 bolt - - - (x) (x) - - - - - - T SAE 2 bolt x x x - - - - - - - - Frame size 30 40 60 80 90 110 125 152 162 182 250 Code Shaft* T SAE key, x x x x x x x x x x x Standard R SAE key, - - - (x) (x) - - - - - - Optional S SAE Spline, x x x x x x x x x x x Optional F SAE Spline, - - - (x) (x) - - (x) (x) (x) (x) Optional U SAE Spline, - - - (x) (x) - - - - - - Optional K Metric key, - - - - - - - - - - x Standard D Spline DIN - - - - - - - - - - (x) 5480 V Tapered (x) (x) (x) - - (x) (x) - - - - shaft *See also dimensional drawings on pages 52-59. Frame size 30 40 60 80 90 110 125 152 162 182 250 Code Option 0000 Standard x x x x x x x x x x x L130 Flushing valve (x) (x) (x) (x) (x) - 1) - 1) - - - - 1.3 mm orifice MUVR Make up/anti (x) - - - - - - - - - - cavitation valve clockwise rotation MUVL Make up/anti cavitation valve counter clockwise rotation (x) - - - - - - - - - - P R 3) P L 3) Pressure relief valve clockwise rotation Pressure relief valve counter clockwise rotation Version number (assigned for special versions) (x) (x) (x) - - - - - - - - (x) (x) (x) - - - - - - - - Frame size 30 40 60 80 90 110 125 152162182250 Code Option 00 Standard x x x x x x x x x x x P_ Prepared for speed (x) (x) (x) (x) (x) (x) (x) (x) (x) (x) (x) sensor B_ Power Boost and (x) - - - - - - - - - - Prepared for speed sensor _T Painted Black (x) (x) (x) (x) (x) (x) (x) (x) (x) (x) (x) 3 x: Available (x): Optional : Not available 1) F12-110 and -125: Accessory valve block (page 62) 2) Metric threads 3) Pressure setting on page 63 4) Not in combination with any valve options Frame size 30 40 60 80 90 110 125 152 162 182 250 Code Shaft seal N NBR, low pressure (x) (x) (x) (x) (x) (x) (x) (x) (x) (x) - V FPM, high pressure, x x x x x x x x x x x high temperature S PTFE, high speed (x) - - - - - - - - - - 45 Parker Hannifin

Series F12 F12-30, -40, -60, -80, -90, -110 and -125 (ISO versions) Port A A3 B3 C3 Port B Flushing valve (optional) A2 B2 C2 Port D K3 G3 G2 Port C 1) N2 H3 L3 K2 H2 (±0.02) Speed sensor (optional) P2 J3 J2 Type K (P) Key shaft L2 Type I flange F3 D3 ØE3 (Tol. k6) 1) Port C Inspection/ drain port D2 M2 ØE2 ØF2 (tol. h8) F12-80 shown ccw cw C1 T3 A1 Port E (third drain port) F12-110 and -125 barrel housing (ISO /cartridge version) Type I mounting flange (ISO 3019/2) A1 B1 ØD1 (x4) Shaft option D (Z) Shaft option V (F12-30) Shaft option V (F12-40) Shaft option V (F12-60) Type D (Z) spline shaft R2 19.29 25.94 24.41 33.66 27.95 38.19 S2 2) Q2 12.19 See table 13.75 Ø1.57 15.62 1-12 UNF-2A Ø1.57 Ø12.50 1 1/8-12 UNF Ø1.57 Key 3.13x3.13x10.20 Ø15.00 1 1/4-12 UNF-2A 2) Type Z has no thread Key 3.76x3.76x17.50 Ø17.50 Tapered key shaft "V" Key 4.37x4.37x20.00 SAE J744 32-3 (C) R0.79 Tapered key shaft "V" SAE J744 38-3 (C-C) Tapered key shaft "V" SAE J744 44-3 (D&E) 46 Parker Hannifin

Series F12 Dim. F12-30 F12-40 F12-60 F12-80 F12-90 F12-110 F12-125 A1 3.48 4.46 4.46 5.01 5.57 B1 4.65 5.75 5.75 6.22 7.09 C1 4.65 5.59 5.67 6.10 7.09 D1 0.43 0.53 0.53 0.53 0.71 A2 3.94 4.33 4.92 5.32 5.71 B2 2.32 2.56 2.76 3.05 3.35 C2 0.98 1.02 0.87 1.26 1.50 D2 0.32 0.32 0.39 0.47 0.55 E2 1.30 1.65 1.65 2.05 2.26 F2 3.9370/ 3.9349 4.9213/ 4.9188 4.9213/ 4.9188 5.5118/ 5.5093 6.2992/ 6.2967 G2 6.77 6.81 7.48 8.50 9.09 H2 1.00 1.28 1.28 1.28 1.59 J2 1.97 2.36 2.36 2.76 3.23 K2 2.16 2.05 2.13 2.76 2.61 L2 1.58 1.97 1.97 2.21 2.76 M2 0.20 0.20 0.20 0.28 0.24 N2 5.37 5.39 6.06 6.79 7.05 P2 0.32 0.32 0.32 0.32 0.32 Q2 1.10 1.10 1.30 1.42 1.61 R2 1) 1.38 1.38 1.57 1.77 1.97 R2 2) 1.69 1.38-1.38 1.77 S2 1)* M12 x0.94 M12 x0.94 S2 2)* - M12 x0.94 M12 x1.10 M16 x1.42 - M12 x1.10 M16 x1.42 - A3 4.80 5.28 5.67 6.10 6.69 B3 2.60 2.60 2.60 2.95 3.29 C3 0.937 0.937 0.937 1.094 1.250 D3* M12 M12 M12 M16 M16 E3 1.1817/ 1.1812 1.1817/ 1.1812 1.3787/ 1.3780 1.5755/ 1.5749 1.7724/ 1.7717 F3 1.30 1.30 1.50 1.69 1.91 G3 5.37 5.39 6.06 6.79 7.05 H3 0.93 1.20 1.20 1.20 1.52 J3 0.95 0.95 1.10 1.42 1.42 K3 2.000 2.000 2.000 2.250 2.626 L3 0.71 0.79 0.79 0.79 0.87 T3 - - - - 2.68 * Metric thread (x depth in inches) 1) Spline shaft type D 2) Spline shaft type Z 3) Max operating pressure 5100 psi 350 bar Ports F12-30 F12-40 F12-60 F12-80 F12-90 F12-110 F12-125 A, B 3 / 4 " 3 / 4 " 3 / 4 " 1" 1 1 / 4 " size Screw thread *) M10 (0.79) M10 (0.79) M10 (0.79) M12 (0.79) M14 (1.02) C thread **) M22 x1.5 M22 x1.5 M22 x1.5 M22 x1.5 M22 x1.5 D thread **) M18 x1.5 M18 x1.5 M22 x1.5 M22 x1.5 M22 x1.5 E thread **) - - - - M22 x1.5 A, B: ISO 6162 *) Metric thread x (depth in inches) **) Metric thread x pitch in mm. Spline shaft (DIN 5480) Type D (std) Type A Type Z (optional) F12-30 W30x2x14x9g - W25x1.25x18x9g 3) -40 W32x2x14x9g W35x2x16x9g W30x2x14x9g -60 W35x2x16x9g - W32x2x14x9g -80 W40x2x18x9g - W35x2x16x9g 3) -90 W40x2x18x9g - W35x2x16x9g 3) -110 W45x2x21x9g - W40x2x18x9g 3) -125 W45x2x21x9g - W40x2x18x9g 3) Metric key shaft (in mm) Type K (std) Type P (opt.) Type J (opt.) Type V (opt.) F12-30 Ø30 Ø25 3) - 32-3 -40 Ø30 - Ø35 38-3 -60 Ø35 - - 44-3 -80 Ø40 - - - -90 Ø40 - - - -110 Ø45 - - 44-3 -125 Ø45 - - 44-3 3 47 Parker Hannifin

Series F12 F12-152, -162 and -182 (ISO versions) Thread M16x2-6H (8x) Depth 1.06 3.98 1.44 0.72 1.56 3.13 7.05 5.20 Approx. Centre of gravity M22x1.5 Case Port D Main ports 1 1/2" (2x) 10.94 8.19 5.00 M22x1.5 Case Port C 1.46 B2 0.32 0.98 Main ports type F (90 deg Vertical) Mounting Flange ISO 3019 A2 Straight Thread 7/16-20 UNF-2B Deair and Flushing Port E A1 ISO 180 (type I) ISO 200 (type F) A1 8.27 9.17 B1 8.27 9.17 C1 6.24 6.96 D1 6.24 6.96 E1 Ø0.71 Ø0.83 A2 7.0866 h8 7.874 h8 7.48 E1 D1 C1 B1 Shaft G and H Shaft D, Z, K and P B2 1.97 1.57 Shaft options K and G Shaft option P Shaft option D Shaft options Z and H 1.46 0.98 1.46 0.98 1.22 M16x2-6H Ø1.9685k6 (+0.0007/ 2.1024 +0.000) 2.76 3.23 0.24 Key 0.55x0.35x2.76 1.22 M16x2-6H Ø1.77165k6 48.4 2.76 0.24 3.23 Key 0.55x0.35x2.76 2.17 1.77 1.22 M16x2-6H W50x2x24x9g (DIN 5480) M16x31 W45x2x21x9g 1.77 1.97 48 Parker Hannifin

Series F12 F12-152, -162 and -182 (ISO versions) Main ports type A (180 deg Vertical) Main ports type D (90 deg Horizontal) Thread M14x2-6H (8x) Depth 0.75 Ø6.89 3.13 1.56 Main ports 1 1/2" (2x) 7.87 3.90 2.63 0.72 1.44 3.98 12.20 11.81 Thread M16x2-6H (8x) Depth 1.06 1.25 3.39 Main ports 1 1/4" (2x) 3 6.42 2.72 5.31 C 9.17 10.94 7.87 Main ports type K (40 deg rear) Main ports 1 1/4" (2x) Main ports type M (Side ports) Ø6.89 Thread M14x2-6H (8x) Depth 0.75 Ø6.89 3.90 2.63 3.98 11.26 7.87 4.61 6.42 4.29 1.25 Main ports 1 1/4" (2x) 6.42 C 9.69 10.94 C 2.63(2x) Thread M14x2-6H (8x) Depth 0.75 1.25(2x) 3.23 9.33 49 Parker Hannifin

Series F12 F12-30, -40, -60, -80, -90, -110 and -125 (Cartridge versions) Port A C6 A6 B6 Port B Flushing valve (optional) A5 C5 B5 Port D Q6 K6 L6 G6 G5 Port C 1) K5 Speed sensor (optional) N5 R6 O-ring (included) H6 H5 (±0.02) S5 T5 P5 Type C spline shaft ØM6 ØN6 ØP6 R5 1) Port C Inspection/ drain port Q5 ØV5 ØF5 (Tol. h8) See table F12-80 shown ccw cw C4 T6 A4 E4 Port E (third drain port) F12-110 and -125 barrel housing (ISO /cartridge version) Type C mounting flange 40 (-30, -40, -60, -110, -125) 43 (-80, -90) ØD4 (x2) B4 Shaft option K (J) Shaft option V (F12-30) Shaft option V (F12-40) Shaft option V (F12-60) J5 D5 Type K (J) key shaft L5 M5 ØE5 (Tol. k6) 19.29 25.94 12.19 Ø1.57 1-12 UNF-2A Ø12.50 Key 3.13x3.13x10.20 Tapered key shaft "V" SAE J744 32-3 (C) R0.79 24.41 33.66 13.75 Ø1.57 1 1/8-12 UNF Ø15.00 Key 3.76x3.76x17.50 Tapered key shaft "V" SAE J744 38-3 (C-C) 27.95 38.19 15.62 Ø1.57 1 1/4-12 UNF-2A Ø17.50 Key 4.37x4.37x20.00 Tapered key shaft "V" SAE J744 44-3 (D&E) 50 Parker Hannifin

Dim. F12-30 F12-40 F12-60 F12-80 F12-90 F12-110 F12-125 A4 6.30 7.87 7.87 8.82 9.84 B4 5.51 6.46 6.46 7.72 8.11 C4 7.40 9.25 9.25 10.24 11.26 D4 0.55 0.71 0.71 0.87 0.87 E4 3.03 3.74 3.74 4.33 4.57 A5 3.94 4.33 4.92 5.31 5.71 B5 2.32 2.56 2.76 3.05 3.35 C5 0.98 1.02 0.87 1.26 1.50 D5 0.31 0.31 1) 0.39 0.47 0.55 0.39 2) E5 1.1817/ 1.1817/ 1) 1.3787/ 1.5755/ 1.7724/ 1.1812 1.1812 1) 1.3780 1.5749 1.7717 1.3787/ 2) 1.3780 2) F5 5.3150/ 5.3125 6.2992/ 6.2967 6.2992/ 6.2967 7.4803/ 7.4775 7.8740/ 7.8712 G5 5.00 5.24 5.75 6.18 6.89 H5 3.50 3.63 3.63 4.35 4.83 J5 1.97 2.36 2.36 2.76 3.23 K5 0.55 0.63 0.59 0.59 0.59 L5 1.57 1.97 1.97 2.20 2.76 M5 0.20 0.20 0.20 0.28 0.24 N5 3.58 3.82 4.33 4.49 4.84 P5 0.87 1.18 1.22 1.57 1.57 Q5 1.10 1.10 1.10 1.46 1.46 R5 1.38 1.38 1.38 1.77 1.77 S5 2.78 2.83 2.99 3.58 3.77 T5 0.59 0.59 0.59 0.59 0.59 V5 1.30 1.38 1.38 1.77 1.77 A6 4.80 5.28 5.67 6.10 6.69 B6 2.60 2.60 2.60 2.95 3.27 C6 0.937 0.937 0.937 1.094 1.250 G6 3.60 3.82 4.33 4.49 4.84 H6 2.74 2.80 2.91 3.52 3.69 K6 2.000 2.000 2.000 2.250 2.626 L6 0.63 0.71 0.71 0.79 0.79 M6 3.62 4.53 4.53 5.12 5.51 N6 4.33 5.00 5.31 6.06 6.30 P6 5.047 6.031 6.031 7.213 7.606 Q6 0.20 0.20 0.20 0.20 0.20 R6 0.20 0.20 0.20 0.20 0.20 T6 - - - - 2.68 1) Key shaft type K 2) Key shaft type B (opt.). Series F12 Ports F12-30 F12-40 F12-60 F12-80 F12-90 F12-110 F12-125 A, B 3 / 4 " 3 / 4 " 3 / 4 " 1" 1 1 / 4 " size Screw thread *) M10 (0.79) M10 (0.79) M10 (0.79) M12 (0.87) M14 (1.02) C thread **) M14 x1.5 M14 x1.5 M14 x1.5 M14 x1.5 M14 x1.5 D, E thread **) M18 x1.5 M18 x1.5 M22 x1.5 M22 x1.5 M22 x1.5 A, B: ISO 6162 *) Metric thread x (depth in inches) **) Metric thread x pitch in mm. Spline shaft (DIN 5480) Type C (standard) Type B (optional) F12-30 W30x2x14x9g - -40 W30x2x14x9g - -60 W30x2x14x9g W35x2x16x9g -80 W40x2x18x9g -90 W40x2x18x9g -110 W40x2x18x9g W45x2x21x9g -125 W40x2x18x9g W45x2x21x9g Metric key shaft (in mm) Type K (std) Type J (opt.) Type V (opt.) F12-30 Ø30-32-3-40 Ø30 Ø35 38-3 -60 Ø35-44-3-80 Ø40 - - -90 Ø40 - - -110 Ø45-44-3-125 Ø45-44-3 O-ring dimensions (in mm) F12-30 127x4-40 150x4-60 150x4-80 180x4-90 180x4-110 190x4-125 190x4 3 51 Parker Hannifin

Series F12 F12-30, -40, -60, -80, -90, -110 and -125 (SAE versions with 4 bolt flange) Port A C9 A9 B9 Port B Flushing valve (optional) A8 C8 B8 Port D K9 G9 G8 Port C 1) N8 Speed sensor K8 (optional) L9 H9 Type S flange J9 D9 ØE9 F9 H8 J8 Type T key shaft 1) Port C Inspection/ drain port D8 ØE8 ØF8 L8 M8 Shown: F12-80 with 4 bolt flange ccw cw C7 T9 A7 Port E (third drain port) F12-110 and -125 barrel housing (SAE version) Type S (SAE 4 bolt) mounting flange A7 B7 ØD7 (x4) Shaft option S (U) Shaft option V (F12-30) Shaft option V (F12-40) Shaft option V (F12-60) R8 Q8 See table Type S (U) spline shaft 19.29 25.94 12.19 Ø1.57 1-12 UNF-2A Ø12.50 Key 3.13x3.13x10.20 Tapered key shaft "V" SAE J744 32-3 (C) R0.79 24.41 33.66 13.75 Ø1.57 1 1/8-12 UNF Ø15.00 Key 3.76x3.76x17.50 Tapered key shaft "V" SAE J744 38-3 (C-C) 27.95 38.19 15.62 Ø1.57 1 1/4-12 UNF-2A Ø17.50 Key 4.37x4.37x20.00 Tapered key shaft "V" SAE J744 44-3 (D&E) 52 Parker Hannifin

Dim. F12-30 F12-40 F12-60 F12-80 F12-90 F12-110 F12-125 A7 3.54 4.51 4.51 4.51 6.36 B7 4.65 5.83 5.83 6.10 8.03 C7 4.65 5.67 5.67 6.10 7.87 D7 0.55 0.55 0.55 0.55 0.83 A8 3.94 4.33 4.92 5.31 5.71 B8 2.32 2.56 2.76 3.05 3.35 C8 0.98 1.02 0.87 1.26 1.50 D8 0.25 0.31 0.31 0.38 0.44 E8 1.30 1.65 1.65 2.05 2.26 F8 4.000/ 3.998 5.000/ 4.998 5.000/ 4.998 5.000/ 4.998 6.000/ 5.998 G8 7.46 7.76 8.43 9.45 10.39 H8 0.31 0.31 0.31 0.31 0.31 J8 1.50 1.89 1.89 2.13 2.64 K8 2.83 2.99 3.11 3.74 3.90 L8 1.25 1.50 1.50 1.75 2.13 M8 0.10 0.16 0.16 0.16 0.29 N8 6.04 6.34 7.02 7.76 8.35 Q8 1) 1.02 1.06 1.06 1.14 1.54 Q8 2) - - - 0.91 - R8 1) 1.30 1.89 1.89 2.13 2.63 R8 2) - - - 1.88 - A9 4.80 5.28 5.67 6.10 6.69 B9 2.60 2.60 2.60 2.95 3.27 C9 0.937 0.937 0.937 1.094 1.250 D9* 5 / 16 "-24 3 / 8 "-24 3 / 8 "-24 1 / 2 "-20 5 / 8 "-18 E9 1.000/ 0.998 1.250/ 1.248 1.250/ 1.248 1.500/ 1.498 1.750/ 1.748 F9 1.11 1.39 1.39 1.498 1.748 G9 6.06 6.34 7.02 7.76 8.35 H9 0.38 0.50 0.50 0.50 0.50 J9 0.63 0.75 0.75 1.02 1.26 K9 2.000 2.000 2.000 2.250 2.626 L9 0.71 0.79 0.79 0.79 0.87 T9 - - - - 2.68 Series F12 Ports F12-30 F12-40 F12-60 F12-80 F12-90 F12-110 F12-125 A, B size 3 / 4 " 3 / 4 " 3 / 4 " 1" 1 1 / 4 " Screw thread **) 3 / 8 "-16 (0.87) 3 / 8 "-16 (0.79) 3 / 8 "-16 (0.87) 7 / 16 "-14 (1.06) 1 / 2 "-13 (0.98) C thread 7 / 8 "-14 7 / 8 "-14 7 / 8 "-14 7 / 8 "-14 1 1 / 16 "-12 D thread 3 / 4 "-16 3 / 4 "-16 7 / 8 "-14 7 / 8 "-14 1 1 / 16 "-12 E thread - - - - 1 1 / 16 "-12 A, B: ISO 6162 C, D, E: O-ring boss (SAE J514) **) UN thread x (depth in inches) Mounting flange (SAE J744) S (standard) R (optional) F12-30 SAE 'B', 4 bolt - -40 SAE 'C', 4 bolt - -60 SAE 'C', 4 bolt - -80 SAE 'C', 4 bolt SAE D, 4 bolt -90 SAE 'C', 4 bolt SAE D, 4 bolt -110 SAE 'D', 4 bolt - -125 SAE 'D', 4 bolt - Spline shaft (SAE J498b, class 1, flat root, side fit) S (standard) U (opt.) F (optional) F12-30 SAE 'B' - - 13T, 16/32 DP -40 SAE 'C' 14T, 12/24 DP - - -60 SAE 'C' 14T, 12/24 DP - - -80 SAE 'C-C' SAE 'C' SAE 'D' 17T, 12/24 DP 14T,12/24DP 3) 13T, 8/16 DP -90 SAE 'C-C' SAE 'C' SAE 'D' 17T, 12/24 DP 14T,12/24DP 3) 13T, 8/16 DP -110 SAE 'D' - - 13T, 8/16 DP -125 SAE 'D' 13T, 8/16 DP - - 3 * UNF-2B thread 1) Spline shaft type S 2) Spline shaft type U 3) Max operating pressure 350 bar Main ports A and B, type U (optional) F12-30 1 1 / 16 " - 12 UN 3) F12-40 1 5 / 16 " - 12 UN 3) F12-60 1 5 / 16 " - 12 UN 3) F12-80 1 5 / 16 " - 12 UN 3) F12-90 1 5 / 16 " - 12 UN 3) F12-110 1 5 / 8 " - 12 UN 3) F12-125 1 5 / 8 " - 12 UN 3) Key shaft (SAE J744) F12 T (standard) R (optional) V (optional) -30 SAE 'B-B' (Ø1") - 32-3 -40 SAE 'C' - 38-3 (Ø1 1 / 4 ") -60 SAE 'C' - 44-3 (Ø1 1 / 4 ") -80 SAE 'C-C' SAE D - (Ø1 1 / 2 ") (Ø1 3 / 4 ") -90 SAE 'C-C' SAE D - (Ø1 1 / 2 ") (Ø1 3 / 4 ") -110 SAE 'D' - 44-3 (Ø1 3 / 4 ") -125 SAE 'D' (Ø1 3 / 4 ") - 44-3 53 Parker Hannifin

Series F12 F12-152, -162 and -182 (SAE versions) Thread M16x2-6H (8x) Depth 1.06 3.98 1.44 0.72 7.05 5.47 Approx. Centre of gravity Straight Thread 1-1/16-12UN-2B Case Port D 3.13 1.56 Main ports 1 1/2" (2x) 9.17 0.50 Straight Thread 1-1/16-12UN-2B Case Port C 5.32 0.32 11.93 Main ports type F (90 deg Vertical) Straight Thread 7/16-20 UNF-2B Deair and Flushing Port E Ø6.00 (+0/0.002 8.07 4.04 Mounting Flange Code S SAE J744 Size 152-4 (D) 7.48 6.36 7.86 3.18 Ø0.83 (4x) 6.36 Shaft option T Ø2.24 min Shaft option S Shaft option F 0.32 0.50 2.63 2.13 R0.03 0.26 Type T key shaft SAE'D' (SAE J744c) 1.94 Ø6.0 (+0/-0.002) Key 7/16x716x2 1/8 5/8-18 UNF depth 30 Ø1.75 (+0/-0.002) SAE'D'; 13T, 8/16 DP class 1, flat root side fit R0.16 1.38 2.63 5/8-11 UNC depth 1.38 Ø1.72 (+0/-0.005) 66.7 1.37 R0.16 Ø1.97(+0/-0.005) 54 Parker Hannifin

Series F12 F12-152, -162 and -182 (SAE versions) Main ports type A (180 deg Vertical) Main ports type D (90 deg Horizontal) Thread M14x2-6H (8x) Depth 0.75 Ø6.89 3.13 1.56 Main ports 1 1/2" (2x) 7.87 3.90 2.63 0.72 1.44 13.15 12.80 3.98 Thread M16x2-6H (8x) Depth 1.06 1.25 3.39 3 6.42 2.72 C 11.93 10.16 Ø6.89 7.87 3.98 Thread M14x2-6H (8x) Depth 0.75 Ø6.89 3.90 2.63 7.87 12.24 4.61 6.42 4.29 1.25 6.42 5.31 Main ports 1 1/4" (2x) Main ports type K (40 deg rear) Main ports type M (Side ports) Main ports 1 1/4" (2x) Main ports 1 1/4" (2x) C 11.89 10.63 2.63(2x) C Thread M14x2-6H (8x) Depth 0.75 1.25(2x) 3.23 10.28 55 Parker Hannifin

Series F12 F12-250 (SAE version) 3.98 Main port A* (1 1 / 2 ") 1.437 M16** 1.38 deep (x8) Main port B* (1 1 / 2 ") 3.125 7.76 4.65 1.06 Approx. center of gravity 5.55 Ø1.54 (x2) Drain port D (BSP 3 / 4 ") 15.55 13.23 Drain port C (BSP 3 / 4 ") 7.09 3.11 0.31 0.94 8.50 R 0.03 0.50 Ø6.0000 Ø5.9980 9.13 ccw cw 7.87 max 6.36 * 6000 psi flange (SAE J518c) ** Metric thread 6.36 7.87 max Type S mounting flange SAE D (SAE J744c) Ø0.83 (x4) 56 Parker Hannifin

Series F12 F12-250 Options (SAE version) 7.76 4.65 0.63 5.37 Speed sensor (optional) 3 3.23 0.24 Type K key shaft (metric; not SAE) R 0.03 Key 14x9x70 (0.55x0.35x2.76 metric key) Ø1.9692 Ø1.9686 Ø2.24 min Shaft option K 2.11 M16 ; deep 1.22 Shaft option T 3.13 R0.06 max 3.0 Type T key shaft (SAE key) Ø2.24 min ½"x½"x3" Ø2.0004 Ø1.9998 2.22 5/8-11 UNCx36 min Ø0.79 Shaft option D Shaft option F Shaft option S 2.17 1.89 R0.16 R0.16 R0.16 2.63 2.63 1.37 1.38 M16 ; deep 1.22 1.9709 1.9528 1.7210 1.9657 1.9465 Ø2.26 Ø2.26 1.7159 Ø2.26 Type D spline shaft W50x2x24x9g DIN 5480 side fit Type F spline shaft SAE J498b, class 1; 15T-8/16 DP; fillet root, side fit Type S spline shaft SAE J498b, class 1; 30 involute spline; 13T-8/16 DP; flat root, side fit 57 Parker Hannifin

Series F12 F12-30, -40, and -60 (SAE versions with 2 bolt flange) A12 B12 C12 Port A Port B Flushing valve (optional) A11 C11 B11 Port D K12 G11 G12 Port C 1) N11 K11 Speed sensor (optional) L12 H12 Type T flange J12 F12 D12 ØE12 H11 Type T key shaft J11 1) Port C Inspection/ drain port D11 ØE11 ØF11 L11 M11 Shown: F12-60 with 2 bolt flange ccw cw C10 R E10 R F10 ØD10 (x2) Type T (SAE 2 bolt) mounting flange A10 B10 Shaft option S Shaft option V (F12-30) Shaft option V (F12-40) Shaft option V (F12-60) R11 Q11 See table Type S spline shaft 19.29 25.94 12.19 Ø1.57 1-12 UNF-2A Ø12.50 Key 3.13x3.13x10.20 Tapered key shaft "V" SAE J744 32-3 (C) R0.79 24.41 33.66 13.75 Ø1.57 1 1/8-12 UNF Ø15.00 Key 3.76x3.76x17.50 Tapered key shaft "V" SAE J744 38-3 (C-C) 27.95 38.19 15.62 Ø1.57 1 1/4-12 UNF-2A Ø17.50 Key 4.37x4.37x20.00 Tapered key shaft "V" SAE J744 44-3 (D&E) 58 Parker Hannifin

Series F12 Dim. F12-30 F12-40 F12-60 A10 5.75 7.13 7.13 B10 6.93 8.46 8.46 C10 2.48 2.91 2.91 D10 0.57 0.69 0.69 E10 0.39 0.63 0.63 F10 0.39 0.61 0.61 A11 3.94 4.33 4.92 B11 2.32 2.56 2.76 C11 0.98 1.02 0.87 D11 0.25 0.31 0.31 E11 1.30 1.65 1.65 F11 4.000/ 3.998 5.000/ 4.998 5.000/ 4.998 G11 7.46 7.76 8.43 H11 0.31 0.31 0.31 J11 1.50 1.89 1.89 K11 2.80 3.03 3.21 L11 1.25 1.50 1.50 M11 0.10 0.16 0.16 N11 6.06 6.34 7.03 Q11 1.02 1.06 1.06 R11 1.30 1.89 1.89 A12 4.80 5.28 5.67 B12 2.60 2.60 2.60 C12 0.937 0.937 0.937 D12 1) 5 / 16 "-24 3 / 8 "-24 3 / 8 "-24 E12 1.000/ 0.998 1.250/ 1.248 1.250/ 1.248 F12 1.11 1.39 1.39 G12 6.06 6.34 7.03 H12 0.38 0.50 0.50 J12 0.63 0.75 0.75 K12 2.000 2.000 2.000 L12 0.71 0.79 0.79 1) UNF-2B thread 6) Max operating pressure 350 bar Ports F12-30 F12-40 F12-60 A, B size 19 ( 3 / 4 ") 19 ( 3 / 4 ") 19 ( 3 / 4 ") Screw thread *) 3 / 8 "-16 (0.87) 3 / 8 "-16 (0.79) 3 / 8 "-16 (0.87) C thread 3 / 4 "-16 3 / 4 "-16 7 / 8 "-14 D thread 3 / 4 "-16 3 / 4 "-16 7 / 8 "-14 A, B (main ports): SAE J518c (6000 psi) C, D (drain ports): O-ring boss (SAE J514) *) UN thread x (depth in inches) Main ports A and B, type U (optional) F12-30 1 1 / 16 " - 12 UN 6) -40 1 5 / 16 " - 12 UN 6) -60 1 5 / 16 " - 12 UN 6) O-ring ports according to SAE J514d Mounting flange T (SAE J744) F12-30 SAE 'B', 2 bolt -40 SAE 'C', 2 bolt -60 SAE 'C', 2 bolt Spline shaft S (SAE J498b, class 1, flat root, side fit) F12-30 SAE 'B' 13 T; 16/32 DP -40 SAE 'C' 14 T; 12/24 DP -60 SAE 'C' 14 T; 12/24 DP Key shaft (SAE J744) T (Standard) F12-30 SAE 'B-B' Ø1" -40 SAE 'C' Ø1 1 / 4 " -60 SAE 'C' Ø1 1 / 4 " V (optional) 32-3 38-3 44-3 3 59 Parker Hannifin

Accessories Accessories Series F11/F12 Content Page Flushing valves for F12 motors...61 FV13 flushing valve block...62 Integrated pressure relief valve...63 Possible pressure settings...63 SR pressure relief / make-up anti-cavitation valve...64 Pressure relief/anticav. valve for F12-motors...65 Dimensions/ SV pressure relief...65 Ordering code...66 Speed sensor...67 BLA Boost Units...68 60 Parker Hannifin

Flushing valves for F12 motors Series F11/F12 Integrated flushing valve (F12-30, -40, -60, -80, -90) General information The integrated flushing valve supplies the motor with a cooling flow through the case which may be required when operating at high speeds and power levels. In a closed loop hydrostatic transmission the flushing valve secures that cool fluid from the charge circuit is constantly added to the main circuit. The flushing valve consists of a three-position, threeway spool valve which connects the low pressure side of the main hydraulic circuit with the motor case. The valve opens at a pressure differential between port A and port B of approximately 14 bar (200 psi). In order to limit the flow, a nozzle with a orifice is available from Parker Hannifin. The diagram to the right shows flow versus differential pressure. For general advise when flushing might be needed, see page 67. Built-in flushing valve Nozzle Ø0.05 inch F12_60_FV_install.eps Leif A./03-01-27 4 Integrated flushing valve (F12-30, -40, -60, -80, -90) Port A Nozzle Ø0.05 inch Q [US gpm] 5.5 5 4 Orifice size (No nozzle) 3 Port B 2 1 Ø0.05 inch Hydraulic schematic. F12_FV_schem.eps Leif A./03-01-27 Ordering code F12 080 MF IV K 000 L130 00 0 0 60 120 180 240 290 Δp [psi] Flow versus pressure differential (port A or B to tank). Standard F12 ordering code (for F12-30, -40, -60, -80, -90) Code L130 Nozzle designation Ø0.05 inch NOTE: FV13 flushing valve block for F12-110 shown on next page. 61 Parker Hannifin

Flushing valves for F12 motors Series F11/F12 FV13 flushing valve block (for F12-110, -125) The FV13 for the F12-110 / -125 motor has the same function as the integrated flushing valve for the other F12 frame sizes. The valve block mounts between the motor port flange and the split-flange tube/hose connectors utilizing long mounting screws (screw size M14x75 or 1 / 2 "-13 UNC based on split-flange height as shown below). The FV13 flushing valve kit contains the required O- rings (shown below) but no screws, split-flanges or tube/ hose connectors. FV13 valve block Restrictor nozzle F12-110 motor Nozzle Ø0.05 inch Port A Port B FV13 flushing valve block F12_FV13_schem.eps Hydraulic schematic. Leif A./03-01-27 FV13 installation 1.25 Ø0.61 (x8) F12_110_FV13_view.eps FV13 Ordering code Leif A./03-01-27 FV 1 3 H A L130 Flushing valve Code Version 1 Factory assigned FV13_squares.eps status Leif A./03-01-28 Valve Version Size Seals Techn. Nozzel type Code Nozzle L130 Ø0.05 inch Code Techn. status A Factory assigned 1.85 Code Size (SAE 6000 psi) 3 1¼" (for F12-110 / -125) Code Seals H Nitrile rubber 2.63 0.28 Nozzle 1.50 3.27 5.59 3.62 1.73 FV13 restrictor nozzles When required, a nozzle is utilized to restrict the flow through the F12-110, -125 motor case. The nozzle installs in the drilled and tapped (M10x1.0) drain line located in the valve block as shown to the left. The diagram on page 59 shows flushing flow versus differential pressure for selected orifice sizes. The following table lists currently available nozzles and the corresponding FV13 ordering code designation. Tube/hose connector Split flange (1.06) Designation Flushing valve Part number L000 no nozzle 3780292 Orifice size [inch] Orifice Part number L130 (std.) 3795623 0.05 379 4413 FV13 valve block O-ring 29.2x3.0 mm O-ring 37.69x3.53 mm (x2) 0.98 Weight: 6.4 lb FV13_install.eps Leif A./03-01-27 62 Parker Hannifin

Pressure relief valve for F12-motors Integrated pressure relief valve ( F12-030, -040, -060 ) Integrated pressure relief valves are available for F12-030, F12-040 and F12-060. These are designed to protect the motor from short duration pressure spikes. The motor could be ordered with non-adjustable pressure setting between 210-420 bar (3050-6090 psi). The motor has to be ordered as unidirectional, L or R, and this is specified in the ordering code as example below. F12-030-MS-SV-S-000-P28L-00 P=Pressure relief valve, 28 = 280 bar, L = left Series F11/F12 Possible pressure settings Code Pressure bar Pressure psi 21 210 (3050) 23 230 (3340) 25 250 (3625) 28 280 (4060) 30 300 (4350) 33 330 (4785) 35 350 (5075) 38 380 (5510) 40 400 (5800) 42 420 (6090) Port A Port B Diagram for PLC082 pressure relief valves integrated in F12-030 p p Pressure override characteristic (bar) (psi) 500 7252 4 400 5802 300 4351 200 2900 100 1450 0 0 25 50 75 100 6.60 13.20 19.81 26.42 q (l/min) (US gpm) Diagram for PLC182 pressure relief valves integrated in F12-040 and F12-060 p p Pressure override characteristic (bar) (psi) 500 7252 400 5802 300 4351 200 2900 100 1450 0 0 25 50 75 100 125 150 175 200q (l/min) 6.60 13.20 19.81 26.42 33.02 39.63 46.23 52.83(US gpm) 63 Parker Hannifin

Pressure relief/anticav. valve for F12-motors Series F11/F12 SR pressure relief anti-cavitation valve The SR pressure relief/make-up valve block for series F12 motors is designed to protect the motor and the main hydraulic lines from short duration pressure spikes. The valve block also provides an excellent make-up function. The valve block installs directly on the motor port flange, and is available in two sizes: 1 3 / 4 " for F12-30/-40/-60 2 1" for F12-80, -90 3 1 for F12-110, -125 The SR valve block consists of a housing containing two high pressure relief cartridges and two separate check valves for anti-cavitation. Cartridges are available in nonadjustable pressure settings between 280 and 420 bar (4 000 and 6000 psi respectively). A make-up port (G) is also provided. In certain operating conditions, the motor (when operating as a pump) may cavitate because of insufficient inlet pressure. To prevent this, the G port should be pressurized. Contact Parker Hannifin for further information. The pressure drop through the main ports (A A' or B B') is low. As an example, the pressure drop on size 1 ( 3 / 4 ") is 0.45 bar (6.5 psi) at 175 l/min (45 gpm), and on size 2 (1") 0.7 bar (10 psi) at 250 l/min (65 gpm). NOTE: The valve block includes main port O-rings (facing the motor) but no mounting screws. Ordering code Port G SR valve block SR valve block location. Port G Port A Port B F12_SR_install.eps Leif A./03-01-31 SR valve block F12 motor SR valve F12_SR_schem_SE.eps block schematic. Leif A./03-01-27 Pressure relief/ make-up valve block SR 1 / 00 H F A Code Port size (SAE 6000 psi) 1 3 / 4 " For: F12-30, -40, -60 2 1" For: F12-80, -90 3 1/4" For: F12-110, -125 Code Serial number 00 Factory assigned SR_SV_squares.eps Leif A./03-01-29 Valve Version Port Serial Seals Threads Techn. function size Pressure settings number status Code Version 1 Factory assigned Code Pressure settings (A/B ports) [bar] 280, 300, 330, 350, 380, 400 or 420 Code Threads (port G) F Metric Code Seals H Nitrile rubber Code Techn. status A Factory assigned Pressure bar Pressure psi 280 (4060) 300 (4350) 330 (4785) 350 (5075) 380 (5510) 400 (5800) 420 (6090) 64 Parker Hannifin

Pressure relief/anticav. valve for F12-motors Series F11/F12 SR pressure relief anti-cavitation valve, Dimensions Check valve Relief valve cartridge A Facing the motor B Ports A/A φ P (x6) Port L Port G (size 1 and 2) C L M D E N thread F Ports B/B G K H M22x1.5*; min 0.63 deep J SR11_install.eps * Metric thread Leif A./03-01-27 Dim. [inch] Size 1 ( 3 / 4 ") Size 2 (1") Size 3 (1¼") A 2.17 2.24 2.24 B 2.17 2.17 0.98 C 1.26 1.26 1.02 D 6.18 6.30 6.30 E 2.60 2.95 3.27 F 0.94 1.09 1.25 G 2.00 2.25 2.63 H 4.06 4.29 3.46 J 5.51 5.91 5.31 K 0.71 0.71 - L 0.71 0.71 0.71 M 3.09 3.15 - N M10 x18 M12 x20 M14 x23 P 0.43 0.51 0.61 Weight Size 1 Size 2 Size 3 ( 3 / 4 ") (1") (1¼") [lb] 16.3 20.1 18.8 4 SV pressure relief valve General information The SV pressure relief valve block for series F12 motors is designed to protect the motor and adjacent hydraulic components from short duration pressure peaks. It installs directly on the motor port flange and is available in two sizes: 1 : 3 / 4 " for F12-30/-40/-60 2 : 1" for F12-80/ -90 The valve block consists of a housing containing two high pressure relief cartridges with anti-cavitation function. Cartridges are available in non-adjustable pressure settings between 280 and 420 bar (4060 and 6090 psi). A make-up/drain port, L, is also provided. In certain operating conditions the motor may cavitate because of in-sufficient inlet pressure. To prevent this, the L port can be pressurized. When there is a risk of over-heating, the L port can also be utilized to take out part of the flow for cooling. Contact Parker Hannifin for further information. The pressure drop through the main ports (A A' or B B') is low. As an example, the pressure drop on size 1 ( 3 / 4 ") is 0.45 bar (6,5 psi) at 175 l/min (45 gpm), and on size 2 (1") 0.7 bar (10 psi) at 250 l/min (65 gpm). NOTE: - The valve block includes main port O-rings (facing the motor) but no mounting screws. - The valve blocks can be used on all versions of series F12 motors. SV pressure relief valve block F12_80_SV_install.eps Leif A./03-01-31 SV valve block installed on an F12 motor. Port A Port B Port L Port A SV valve block Port B Hydraulic schematic. (F12) F12_SV_schematic.eps Leif A./03-01-29 65 Parker Hannifin

Ordering code Series F11/F12 SV 1 / 00 H F A SR_SV_squares.eps Leif A./03-01-29 Valve Version Port Serial Seals Threads Techn. function size Pressure setting number (port L) status Pressure relief valve Code Version 1 Factory assigned Code Port size (SAE 6000 psi) 1 3 / 4 " F12-30, -40, -60 2 1" F12-80, -90 Pressure bar Pressure psi 280 (4060) 300 (4350) 330 (4785) 350 (5075) 380 (5510) 400 (5800) 420 (6090) Code Pressure settings (A/B ports) [bar] 280, 300, 330, 350, 380, 400 or 420 Code Serial number 00 Factory assigned Code Threads (port L) F Metric Code Seals H Nitrile rubber Code Techn. status A Factory assigned SV pressure relief valve, Dimensions E F G A B Facing the motor Port A C D Make-up port L (M22x1.5 metric thread) Ø K (x8) Port B H SV_install.eps Leif A./03-01-27 J Port A Port B relief valve cartr. Dim. [inch] SV11 SV12 A 2.80 2.87 B 1.22 1.22 C 1.41 1.61 D 1.85 2.01 E 5.12 5.00 F 2.60 2.95 G 0.94 1.09 H 2.00 2.25 J 3.90 4.29 K 0.43 0.51 Weight [lb] 9.3 11.0 66 Parker Hannifin

Speed sensor A speed sensor kit is available for series F11/F12. A ferrostat differential (Hall-effect) sensor installs in a separate, threaded hole in the F11/F12 bearing housing. On F12 the speed sensor is directed towards the ring gear. On F11 the speed sensor is directed towards the pistons. The sensor output is a 2 phase shifted square wave signal within a frequency range of 0 Hz to 15 khz. NOTE: - The motor bearing housing must be prepared for the speed pick-up; refer to the F11/F12 ordering codes on pages 12-14(F11) and 43-45 (F12). - On F11 the pistons position must be known before mounting. - Additional information is provided in the marketing information HY30-8301/UK. - The speed sensor is also shown in the illustrations on pages 17 to 37 and 46 to 57. Part number for Speed sensor is 3785190. Series F11/F12 F12 with speed sensor. F12_speed_sensor.eps Leif A./020204 Speed sensor Speed sensor 4 F11-14 with speed sensor. 67 Parker Hannifin

BLA Boost Units BLA General information The BLA boost unit simplifies the building of closed or semi-closed hydrostatic transmissions. Main features are: Replaces conventional charge pump and corresponding valves in many applications Allows pump speeds above normal selfpriming speed Suitable for system flow rates to 400 l/min (106 USgpm) Includes filter Simple construction - no moving/wear parts Cost-effective installation Small tank size Helps in building a low-cost hydrostatic transmission. Description In a closed circuit hydrostatic transmission, a charge pump is normally included with the main pump, providing make-up fluid which replaces pump and motor volumetric losses. It also maintains sufficient pump inlet pressure to avoid cavitation. The BLA boost unit replaces the charge pump in many applications, when the following conditions are met: - The max-to-min pump flow ratio does not exceed 2:1 - System pressure changes gradually without frequent and pronounced pressure peaks - The line length between pump and boost unit is relatively short. There are two basic sizes of the BLA boost unit: - BLA 4 (to 160 l/min (42 US gpm) pump flow) - BLA 6 (to 400 l/min (106 US gpm) pump flow). The main part of the unit is an aluminium housing with a built-in nozzle and an injector; refer to the cross section to the right. When fluid flows from the motor outlet port through the unit and to the pump inlet port, the increased fluid velocity between the nozzle and injector creates a low pressure zone causing additional fluid to be drawn from tank into the main circuit. Also, pressure increases after the injector, allowing the pump to be operated at speeds higher than the selfpriming speed. The boost pressure increases with flow. The housing includes ports that should be connected to the pump and motor drain ports respectively. An additional bleed-off nozzle diverts approx. 10% of the main flow through the cartridge filter before being directed to the tank. Oil cooling An oil cooler is usually required in the hydraulic system, in order to remove the heat that is generated in the main circuit. A full-flow oil cooler should be installed in the return line between the motor and the boost unit. For more information please see our technical catalogue BLA boost unit HY17-8224/UK BLA Boost units Series F11/F12 Typical applications: Fan drives Propeller drives Generator drives Pump drives To pump inlet BLA boost unit cross section. BLA_cross_section.eps Leif A./02-01-03 1 Injector From Nozzle tank 1. Pump 2. Motor 3. Boost unit (with injector and nozzle 4. Filter cartridge To filter From filter to tank Boost unit installation 3 4 7 6 5 From motor outlet Bleed-off nozzle 2 5. Pressure relief valve 6. Full-flow filter (when required 7. Reservoir BLA_install.eps Leif A./02-01-03 68 Parker Hannifin

Installation information Series F11/F12 Direction of rotation The motor versions are bi-directional. The pump versions are uni-directional, allowing higher selfpriming speeds (refer to pages 9, 11 and 40, 42). The illustration to the right shows direction of flow versus shaft rotation. In a motor application, the shaft turns clockwise when port B (black arrow) is pressurized, and counter clockwise when port A (open arrow) is pressurized. In a pump application where the shaft turns clock-wise, port B is the inlet port and should be connected to tank; when the shaft turns counter clockwise, port A is the inlet port. Counter clockwise rotation Port A Clockwise rotation Port B Hydraulic fluids Ratings and performance data for series F11/F12 are based on operating with good quality, contaminationfree, petroleum-based fluids. Hydraulic fluids type HLP (DIN 51524), automatic transmission fluids type A, or API CD engine oils can be used. Fire resistant fluids (when used under modified operating conditions) and synthetic fluids may also be suitable. NOTE: When operating the F11/F12 as a pump above the selfpriming speed (valid for both the pump and motor versions), the inlet must be sufficiently pressurized. Increased noise and deteriorating performance may otherwise be experienced. For further information refer to Selfpriming speed and required inlet pressure on pages 11 and 42. 5 Operating temperature The following temperatures should not be exceeded (type V FPM shaft seals): Main circuit 80 C 176 F Drain circuit: 115 C 239 F. NBR shaft seals (type N) can be used to 90 C 194 F drain fluid temperature. NOTE: The temperature should be measured at the utilized drain port. Continuous operation may require case flushing in order to meet the viscosity and temperature limitations. The following table shows operating speeds, above which flushing is usually required, as well as suggested flow through the case. F11/F12 in series operation When running F11/F12 in series at higher pressure levels, Please contact Parker Hannifin for further information. Series F11 Frame size Speed [rpm] Flow [l/min] Flow [gpm] F11-5 5500 1-2 0.25-0-5 F11-6 4500 2-3 0.5-0.8 F11-10 4500 2-3 0.5-0.8 F11-12 4500 2-3 0.5-0.8 F11-14 4500 2-3 0.5-0.8 F11-19 4000 2-4 0.5-1.0 Series F12 Frame size Speed [rpm] Flow [l/min] Flow [gpm] F12-30 3500 4-8 1.0-2.1 F12-40 3000 5-10 1.3-2.6 F12-60 3000 7-14 1.9-3.7 F12-80 2500 8-16 2.1-4.2 F12-90 2500 8-16 2.1-4.2 F12-110 2300 9-18 2.4-4.8 F12-125 2300 9-18 2.4-4.8 F12-150 2200 10-20 2.6-5.2 F12-250 1800 12-22 3.2-5.8 69 Parker Hannifin

Installation information Series F11/F12 Viscosity The ideal operating range is15 to 30 mm 2 /s [cst]. At operating temperature, the viscosity (of the drain fluid) should be kept above 8 mm 2 /s [cst]. At start-up, the viscosity should not exceed 1000 mm 2 /s [cst] Filtration To obtain the highest service life of the F11/F12, the fluid cleanliness should meet or exceed ISO code 20/18/13 (ISO 4406). During normal operating conditions, a 10 µm (absolute) filter is recommended. Case pressure The service life of the shaft seal ring is affected by the speed of the motor and the case drain pressure and it can decrease with an increase in the frequency of pressure peaks. Note, seal life can be shorter at unfavourable operating conditions (high temperature, low oil viscosity, contaminated oil). The table below shows recommended case pressure as a function of shaft speed. Shaft speed [rpm] 1500 3000 4500 6000 max F11-5, -6, -10, -12, -14, -19 F12-30, -40, -60, -80, -90 F12-110, -125, -152, -162, -182-250 [bar] [psi] [bar] [psi] [bar] [psi] 0.5-10 7.3-145 0.5-8 7.3-116 0.5-6 7.3-87 0.5-7.0 7.3-102 0.5-6.0 7.3-87 1.0-4.0 14.5-58 1.0-5.0 14.5-72 1.0-4.5 14.5-2.0-4.0 29-58 The case pressure must be equal to or greater than the external pressure on the shaft seal ring. 2.0-5.0 29-72 2.0-4.0 29-58 3.0-5.0 43-72 - - - To secure correct case pressure and lubrication, a spring loaded check valve, 1-3 bar (14.5-43,5 psi), in the drain line (shown on next page) is recommended. Note. Contact Parker Hannifin for information when operating at high speeds. 70 Parker Hannifin

Installation information Series F11/F12 Case drain connections Series F11/F12 have two drain ports, C and D, while F12-110 and -125 have an additional port, E. The uppermost drain port (such as port C in the illustration below) should always be utilized. Drain flow Recommended 1-3 bar 14.5-43,5 psi Drain flow Recommended 1-3 bar 14.5-43,5 psi Port C Port E (F12-110 and -125) Port D Flushing flow (when required) F12_ports.eps In mounting positions Leif such A./020204 as 'shaft up' (below) a spring loaded check valve should be installed in the drain line in order to insure a sufficiently high oil level in the case. Preferably, the drain line should be connected directly to the reservoir. Drain flow Recommended 1-3 bar 14.5-43,5 psi 5 Spring loaded check valve 1-3 bar 14.5-43,5 psi Drain flow Drain flow Recommended 1-3 bar 14.5-43,5 psi Before start-up Make sure the F11/F12 case as well as the entire hydraulic system is filled with a recommended fluid. The internal leakage, especially at low operating pressures, is not sufficient to provide lubrication at start-up. NOTE: - To avoid cavitation and obtain a low noise level as well as reduced heat generation, tubes, hoses and fittings must be adequately dimensioned. - Preferably, the suction line flow speed should be 0.5 to 1 m/s (1.6 to 3.3 ft/s), and pressure line flow speeds 3 to 5 m/s (9.8 to 16.4 ft/s). 71 Parker Hannifin

Parker Worldwide Europe, Middle East, Africa AE United Arab Emirates, Dubai Tel: +971 4 8127100 parker.me@parker.com AT Austria, Wiener Neustadt Tel: +43 (0)2622 23501-0 parker.austria@parker.com AT Eastern Europe, Wiener Neustadt Tel: +43 (0)2622 23501 900 parker.easteurope@parker.com AZ Azerbaijan, Baku Tel: +994 50 22 33 458 parker.azerbaijan@parker.com BE/LU Belgium, Nivelles Tel: +32 (0)67 280 900 parker.belgium@parker.com BG Bulgaria, Sofia Tel: +359 2 980 1344 parker.bulgaria@parker.com BY Belarus, Minsk Tel: +48 (0)22 573 24 00 parker.poland@parker.com CH Switzerland, Etoy Tel: +41 (0)21 821 87 00 parker.switzerland@parker.com CZ Czech Republic, Klecany Tel: +420 284 083 111 parker.czechrepublic@parker.com DE Germany, Kaarst Tel: +49 (0)2131 4016 0 parker.germany@parker.com DK Denmark, Ballerup Tel: +45 43 56 04 00 parker.denmark@parker.com ES Spain, Madrid Tel: +34 902 330 001 parker.spain@parker.com FI Finland, Vantaa Tel: +358 (0)20 753 2500 parker.finland@parker.com FR France, Contamine s/arve Tel: +33 (0)4 50 25 80 25 parker.france@parker.com GR Greece, Athens Tel: +30 210 933 6450 parker.greece@parker.com HU Hungary, Budaoers Tel: +36 23 885 470 parker.hungary@parker.com IE Ireland, Dublin Tel: +353 (0)1 466 6370 parker.ireland@parker.com IT Italy, Corsico (MI) Tel: +39 02 45 19 21 parker.italy@parker.com KZ Kazakhstan, Almaty Tel: +7 7273 561 000 parker.easteurope@parker.com NL The Netherlands, Oldenzaal Tel: +31 (0)541 585 000 parker.nl@parker.com NO Norway, Asker Tel: +47 66 75 34 00 parker.norway@parker.com PL Poland, Warsaw Tel: +48 (0)22 573 24 00 parker.poland@parker.com PT Portugal Tel: +351 22 999 7360 parker.portugal@parker.com RO Romania, Bucharest Tel: +40 21 252 1382 parker.romania@parker.com RU Russia, Moscow Tel: +7 495 645-2156 parker.russia@parker.com SE Sweden, Spånga Tel: +46 (0)8 59 79 50 00 parker.sweden@parker.com SK Slovakia, Banská Bystrica Tel: +421 484 162 252 parker.slovakia@parker.com SL Slovenia, Novo Mesto Tel: +386 7 337 6650 parker.slovenia@parker.com TR Turkey, Istanbul Tel: +90 216 4997081 parker.turkey@parker.com UA Ukraine, Kiev Tel: +48 (0)22 573 24 00 parker.poland@parker.com UK United Kingdom, Warwick Tel: +44 (0)1926 317 878 parker.uk@parker.com ZA South Africa, Kempton Park Tel: +27 (0)11 961 0700 parker.southafrica@parker.com North America CA Canada, Milton, Ontario Tel: +1 905 693 3000 US USA, Cleveland (industrial) Tel: +1 216 896 3000 US USA, Elk Grove Village (mobile) Tel: +1 847 258 6200 Asia Pacific AU Australia, Castle Hill Tel: +61 (0)2-9634 7777 CN China, Shanghai Tel: +86 21 2899 5000 HK Hong Kong Tel: +852 2428 8008 ID Indonesia, Tangerang Tel: +62 21 7588 1906 IN India, Mumbai Tel: +91 22 6513 7081-85 JP Japan, Fujisawa Tel: +81 (0)4 6635 3050 KR South Korea, Seoul Tel: +82 2 559 0400 MY Malaysia, Shah Alam Tel: +60 3 7849 0800 NZ New Zealand, Mt Wellington Tel: +64 9 574 1744 SG Singapore Tel: +65 6887 6300 TH Thailand, Bangkok Tel: +662 186 7000 TW Taiwan, New Taipei City Tel: +886 2 2298 8987 VN Vietnam, Ho Chi Minh City Tel: +84 8 3999 1600 South America AR Argentina, Buenos Aires Tel: +54 3327 44 4129 BR Brazil, Cachoeirinha RS Tel: +55 51 3470 9144 CL Chile, Santiago Tel: +56 2 623 1216 MX Mexico, Toluca Tel: +52 72 2275 4200 Ed. 2016-04-04 2016 Parker Hannifin Corporation. All rights reserved. Parker Hannifin Corporation Hydraulics Group 6035 Parkland Boulevard Cleveland, OH 44124 phone 1 800-C PARKER www.parker.com/hydraulics Catalogue HY30-8249/US. POD 05/2016, ZZ Your local authorized Parker distributor