HYDRAULIC MOTORS Concentric AB

Size: px
Start display at page:

Download "HYDRAULIC MOTORS Concentric AB"

Transcription

1 HYDRAULIC MOTORS Concentric A Innovation in Hydraulics

2 Introduction to Concentric Hydraulic Motor Capability Concentric offers one of the widest selections of gear pumps and hydraulic motors in the industry. All Concentric products are designed to provide solutions to our customers application challenges. Concentric hydraulic motors are applied on turf care equipment, agricultural equipment, industrial sweepers, paving machinery, winches and fan drives for a number of off-highway vehicles. They are specified by leading equipment manufacturers throughout the mobile equipment market. The Concentric line of hydraulic motors covers a displacement range from.065 in. 3 (1 cc) to 9.82 in. 3 (161 cc). The various series include cast iron fixed clearance, aluminum body pressure balanced, and cast iron pressure balanced designs. oth unidirectional and birotational configurations are available. Each series offers a large selection of shaft, flange and valve options to meet your application requirements. Series Table of Contents Page GC...(Uni- or irotational) Fixed Clearance Hydraulic Motors... 3 WM600...(Uni- or irotational) Pressure alanced Hydraulic Motors... 8 WM900...(Uni- or irotational) Pressure alanced Hydraulic Motors...15 WM (Uni- or irotational) Pressure alanced Hydraulic Motors...24 FM15...(Unirotational) Pressure alanced Hydraulic Motors...32 FM20...(Unirotational) Pressure alanced Hydraulic Motors...38 FM30...(Unirotational) Pressure alanced Hydraulic Motors...39 Quick Reference Chart GC Series WM600 Series WM900 Series WM1500 Series FM15 Series FM20 Series FM30 Series cc 2 cc 8 cc 12 cc 24 cc 33 cc 50 cc 65 cc 82 cc 98 cc 114 cc 131 cc 161 cc Displacement (in. 3 /rev.) (cc/rev) 2 Pictures on front cover are used with the kind permission of eg: Atlet, T, Huddig, Scania, Toro and Volvo Construction Equipment.

3 GC Series Hydraulic Motors GC Series Hydraulic Motors are compact bidirectional external gear motors. These motors feature cast iron bodies and needle bearings for long life under severe conditions. A variety of shaft, flange and valve options can be specified on GC Series Motors. A unique feature of these motors is their high speed performance. GC Series Hydraulic Motor Dimensions See dimensional chart on top of page 4 for dimensions A,, and C in drawings below. 4-olt Flange SAE (J514) STRAIGHT THREAD PORT A.28 [7.11] CHECK VALVE.115 [2.92].135 [3.43] 1.00 LONG x.1240 [3.15] WIDE KEY [25.4].1235 [3.14] [45.25] DIA [45.21] IROTATIONAL [25.4] [50.8].41 [10.4] RAD. TYP. (4).500 [12.7] 1.38 [35.05].553 [14.05].543 [13.79] 2.81 [71.37].5000 [12.70].4997 [12.69] DIA. SHAFT 1.41 [35.8] [50.8] [25.4] DRAIN PORT 7/16-20 SAE (J514) STRAIGHT THREAD C.03 [.76] x 45º CHAMFER 1.52 [38.6] 1.48 [37.7] 1.41 [35.8] 2.81 [71.37].344 [8.74] THRU MOUNTING HOLES (4) SAE AA 2-olt Flange SAE (J514) STRAIGHT THREAD PORT A.28 [7.11] CHECK VALVE.115 [2.92].135 [3.43] 1.00 LONG x.1240 [3.15] WIDE KEY [25.4].1235 [3.14] [50.80] DIA [50.75] [41.28] IROTATIONAL [82.55].500 [12.7] 1.38 [35.05].553 [14.05].543 [13.79].5000 [12.70].4997 [12.69] DIA. SHAFT DRAIN PORT 7/16-20 SAE (J514) STRAIGHT THREAD C.03 [.76] x 45º CHAMFER 1.52 [38.6] 1.48 [37.7] 2.00 [50.8] 4.00 [101.6].406 [10.3] THRU MOUNTING HOLES (2) SAE A 2-olt Flange SAE (J514) STRAIGHT THREAD PORT A.34 [8.64] CHECK VALVE.24 [6.1].26 [6.6] 1.00 LONG x.1240 [3.15] WIDE KEY [25.4].1235 [3.14] [82.55] [82.50] DIA [53.18] IROTATIONAL [106.36].500 [12.7] 1.38 [35.05].553 [14.05].543 [13.79].5000 [12.70].4997 [12.69] DIA. SHAFT DRAIN PORT 7/16-20 SAE (J514) STRAIGHT THREAD C.03 [.76] x 45º CHAMFER 1.52 [38.6] 1.48 [37.7] 2.56 [65.02] 5.12 [130.05].438 [11.13] THRU MOUNTING HOLES (2) 3

4 GC Hydraulic Motor Shaft Options Dimensional chart below corresponds to dimensional drawings on page 3. Dimensions are inches [mm] A 3.16 [80.26] 2.82 [71.62] C 2.41 [61.21] A 3.66 [92.96] 4.16 [105.66] 3.32 [84.32] 3.82 [97.02] C 2.41 [61.21] Inlet Outlet [61.21] [73.91] Extended Shaft SAE A SPLINE Shaft Threaded Shaft 9T, 20/40 DP standard with 4-bolt and 2-bolt SAE AA flanges. 9T, 16/32 DP standard with 2-bolt SAE A flange. GC Hydraulic Motor Seal & earing Options Five (5) basic seal and bearing configurations are available as shown here. Oil seals are either una-n or Viton. Outboard ball bearings are available for belt or gear drives and thrust loads. See PV factors (bottom of page 5) for seal ratings. 1, SINGLE LIP LOW PRESSURE SEAL HIGH PRESSURE SEAL DOULE SEAL WITH WITH OUTOARD EARING OVEROARD DRAIN FOR THRUST LOAD SEAL WITH OUTOARD EARING FOR ELT OR GEAR DRIVE

5 GC Hydraulic Motor Radial Loads MAXIMUM FLUID MOTOR RADIAL LOADS (without outboard ball bearing) Clockwise Rotation Pressure Max. Radial Load at 6 O Clock PSI AR LS N For all other angles, consult factory GC Hydraulic Motor Shaft Seal Capabilities To insure that the performance capabilities of the shaft seal are not exceeded, use the chart below. Multiply as follows: (PV Factor = PSI x Shaft Dia. (in.) x ( ) x RPM. Take this value and by 12 in./ft.). This figure must not exceed the Pressure / Velocity factor shown in column 4. Outlet pressure on a uni-directional motor or case drain pressure on a bi-rotational motor must not exceed seal pressure ratings. Max. Seal Pressure PSI (ar) Temp. Range o F ( o C) PV Factor (psi-fpm) Standard una Standard Viton High Pressure Viton 10 (.7) 10 (.7) RPM RPM -65 to 225 (-54 to 107) -40 to 400 (-40 to 204) -40 to 350 (-40 to 177) N/A N/A

6 GC Hydraulic Motor Valve Options The schematic drawings shown below illustrate standard valve options offered on the GC hydraulic motors. Inlet Relief Valve C i-rotational Check Valves OPTIONS C I J N DESCRIPTION I Overruning Check Valve Inlet Relief Valve i-rotational Check Valves Overrunning Check Valve Cross-Over Relief Valves w/case Drain None GC Performance 100 SSU J Cross Over Relief Valves w/case Drain GC 8.5 CC.517 CU. IN. 8 GC 6.4 CC.388 CU. IN. Inlet Flow (GPM) 6 4 GC 4 CC.258 CU. IN. GC 3 CC.194 CU. IN. GC 2 CC.129 CU. IN. Inlet Flow vs. Output Motor Max. Pressure 2 GC 1 CC.065 CU. IN Motor Output Speed (RPM) GC 1 CC.065 CU. IN. GC 2 CC.129 CU. IN. GC 3 CC.194 CU. IN. GC 4 CC.258 CU. IN. Pressure vs. Max. Speed GC 6.4 CC.388 CU. IN. GC 8.5 CC.517 CU. IN. 6 (lb.-in.)

7 Installation Information FLUIDS - Most premium grade petroleum base fluids can be used with GC Motors. Optimum operating viscosity is cst ( SSU) at maximum rated speed. Minimum operating viscosity is 10 cst (59 SSU). Maximum operating viscosity is 750 cst (3409 SSU). Maximum cold start viscosity is 2000 cst (9091 SSU). Contact us for additional information regarding the GC performance using other fluids. OPERATING TEMPERATURES - Fluid temperature range (Mineral Oil): Max. 93ºC (200ºF) continuous and Max. 105ºC (221ºF) intermittent. FILTRATION - Proper filtration is critical to the trouble free operating of any hydraulic system. For optimum motor life at maximum pressure ISO 4406/1986 ( 18/14) is recommended. A 10-micron filter sized to accommodate full system return flow is recommended for most operating environments. GC Series Hydraulic Motor Each GC Series Motor option has been assigned an order code which is listed in the tables below. Configure the desired options as shown in the example model code to the right. EXAMPLE GCM A 1 A 10 Your Options GCM DESIGN CODE MOUNTING FLANGE SHAFT DISPLACEMENT VALVING SEALS & EARINGS PORTING ROTATION CASE DRAIN RELIEF VALVE SETTING 2. MOUNTING FLANGE 1 4-olt w/ 1.78 Pilot 2 2-olt SAE AA w/ 2.0 Pilot 4 2-olt SAE A w/ 3.25 Pilot 3. DRIVE SHAFTS Dia. x 1.50 Ext., 1/8 Sq. Key 4 Threaded End (Specify Thread) 5 SAE Spline (9 Tooth) - 20/40DP standard with flange options 1 and 2; - 16/32DP standard for flange option piece minimum order 4. DISPLACEMENT In. 3 CC piece minimum order 6. SEAL & EARING OPTIONS 1 Single Lip una-n Low Pressure Seal 2 Viton Seal 3* Viton High-Pressure Seal w/outboard all earing 4 * Double Seal w/overboard Drain 5* una-n Seal w/outboard all earing 100-piece minimum order * Not available with shaft option 3 7. PORT LOCATION OPTIONS A SAE Side Ports SAE Rear Ports C NPTF Side Ports D NPTF Rear Ports E * Inlet Tube, 1.0 Dia. w/ SAE Side Outlet Port NOTE: If ordering NPTF Ports, specify size: 1/4, 3/8 or 1/ piece minimum order 8. ROTATION 1 Clockwise 2 Counter Clockwise 3* irotational * Must specify Option C, J or A in Valve Options. Option A is for case drain. 9. CASE DRAIN A Case Drain N None 10. RELIEF VALVE SETTINGS Full bypass pressure in hundreds of PSI. (Example: 00 = No Relief; 09 = 900 PSI (Full ypass Pressure); 40 = 4000 PSI (Full ypass Pressure) Note: The maximum relief valve fulll bypass setting for each gear size as listed on page 2 of GC Series Pump Catalog, intermittent rating pressure chart. Minimum full bypass relief valve settings: 200 PSI for gear sizes at 1725 RPM, 300 PSI for gear sizes at 1725 RPM. At speeds above 1725 RPM, the minimum relief valve settings increase. Contact factory for specific information. 5. VALVE OPTIONS Inlet Relief Valve C i-rotational Check Valves I Overrunning Check Valve J Cross-Over Relief Valves w/case Drain N None 7

8 W SERIES HYDRAULIC MOTORS W Series motors are available in 3 families with displacements ranging from.183 in. 3 to 3.05 in. 3 (3 cc to 50 cc). W Series motors are available in both unirotational or birotational configurations. All feature a three-piece bushing block design for high pressure operation. A number of shaft and flange combinations are available. Integral valve options provide ease of system design. A key feature of all motors in the W Series is the extremely high volumetric efficiency. WM600 Flange Options SAE AA 2-OLT ORDER CODE 02 (Dry Mount) / ORDER CODE 22 (Wet Mount) 4X 21 o [4.134] MAX. THESE HOLES NOT PRESENT ON CODE 22 WET MOUNT [.25] [.24] X MAX. Y [.44] [.40] 68.4 [2.69] MAX [2.528] MAX [.41] [2.000] [1.998] 12.7 [.50] 55.3 [2.177] 86 [3.39] MAX. INLET 82.6 [3.252] OUTLET SAE A 2-OLT ORDER CODE 03 (Dry Mount) / ORDER CODE 33 (Wet Mount) 4X 32 o [4.910] MAX. THESE HOLES NOT PRESENT ON CODE 33 WET MOUNT [.25] [.24] Y [.588] MAX. X MAX [2.69] MAX [3.78] MAX [.43] [3.250] [3.248] 12.7 [.50] 86 [3.39] MAX [2.177] INLET [4.189] OUTLET [.46] [.40] R 12.3 [.48] MIN. WM600 Dimensions & Weights (See dimensional drawings above.) Displacement X Max. X Max. Y Port Y Port Approx. Wt. cm 3 in 3 (2-olt) (4-olt) (2-olt) (4-olt) kgs. {lbs.] [3.25] [4.19] [1.75] [2.69] [5.45] [3.30] [4.24] [1.86] [2.81] [5.5] [3.36] [4.30] [1.86] [2.81] [5.6] [3.51] [4.45] [1.86] [2.81] [5.7] [3.63] [4.53] [1.86] [2.81] [5.8] [3.80] [4.74] [1.86] [2.81] [5.9] [3.93] [4.87] [1.93] [2.87] [6.1] [4.17] [5.11] [2.05] [2.99] [6.3] 8

9 WM600 Shaft Options STRAIGHT KEYED SHAFT SAE AA ORDER CODE AA 3.18 x 3.18 x 25.4 [.125 x.125 x 1.0] KEY [.554] [.544] [1.52] [1.48] 5/8 STRAIGHT KEYED SHAFT SAE A ORDER CODE CA 3.97 x 3.97 x [.156 x.156 x.75] KEY [.698] [.688] [1.28] [1.24] [.500] [.498] [.625] [.624] SAE AA SPLINE ORDER CODE EA SAE A SPLINE ORDER CODE FA [.79] [.77] [1.08] [1.04] [.95] [.91] [1.28] [1.24] [.57] [.54] [.72] [.71] [.485] [.480] EXTERNAL INVOLUTE SPLINE 20/40 DP, 9 TOOTH, FLAT ROOT, SIDE FIT [.608] [.603] EXTERNAL INVOLUTE SPLINE 16/32 DP, 9 TOOTH, FLAT ROOT, SIDE FIT SAE A TAPERED SHAFT ORDER CODE LA [.73] [.71] 1/2-20 UNF-2 HEX NUT TORQUE Nm [ L.FT.] [.635] [.615] [1.74] [1.70] 1:8 TAPER #505 WOODRUFF KEY (ANSI R1978) [.084] [.074] SPRING LOCKWASHER (ANSI ) 9

10 WM600 Axial/Radial Loads MAXIMUM FLUID MOTOR AXIAL LOADS - MAX. 400 N. (90 LS.) AT VISCOSITY OF 10 CST (59 SSU) (OTH DIRECTIONS) - THE RESULTANT LOAD FROM THE AXIAL AND RADIAL FORCES MUST E LESS THAN 600 N. (135 LS.). Radial Axial 25 mm MAXIMUM FLUID MOTOR RADIAL LOADS Clockwise Rotation Pressure Max. Radial Load at 6 O Clock PSI AR LS N For all other angles, consult factory

11 WM600 Shaft Seal Capabilities Outlet pressure on a uni-directional motor or case drain pressure on a bi-rotational motor must not exceed seal pressure ratings. Max. Pressure PSI (ar) Temp. Range ºF (ºC) Standard una Standard Viton 44 (3) 116 (8) 5 to 176 (-15 to 80) 5 to 221(-15 to 105) Important Note: The above data are maximum values and cannot be used concurrently, e.g. the maximum operating pressure depends on material type, shaft speed and temperature. Contact your Haldex representative for additional information. WM600 Performance 100 SSU WM600 Flow vs. Max. P1 Pressure with 100 SSU Fluid WM600 Inlet Pressure vs. Max. RPM with 100 SSU Fluid 11

12 WM600 Case Drain Case drain leakage is less than 0.38 LPM (.1 GPM) with 20.6 cst (100 SSU) fluid. Installation Information FLUIDS - Most premium grade petroleum base fluids can be used with WM600 Motors. Optimum operating viscosity is cst ( SSU) at maximum rated speed. Minimum operating viscosity is 10 cst (59 SSU). Maximum operating viscosity is 750 cst (3409 SSU). Maximum cold start viscosity is 2000 cst (9091 SSU). Contact Concentric for additional information regarding the W600 performance using other fluids. OPERATING TEMPERATURES - Fluid temperature range (Mineral Oil): Max. 93 o C (200 o F) continuous and Max. 105 o C (221 o F) intermittent. FILTRATION - Proper filtration is critical to the trouble free operating of any hydraulic system. For optimum motor life at maximum pressure ISO 4406/1986 ( 18/14) is recommended. A 10-micron filter sized to accommodate full system return flow is recommended for most operating environments. WM600 Valve Options The schematic drawings shown below illustrate standard valve options offered on the WM600 hydraulic motors. FC Inlet Relief Valve GE Overruning Check Valve FD Cross Over Relief Valves w/case Drain 12 OPTIONS FC GE FD DESCRIPTION Inlet Relief Valve Overrunning Check Valve Cross-Over Relief Valves w/case Drain

13 WM600 Valve Option Dimensions The drawings below depict the overall dimensions for the valve options specified on page 12. RELIEF VALVE, CW ROTATION D E 76.6 [3.02] 9.2 [.36] 12.7 [.50] 55.3 [2.176] OUTLET PORT OVER-RUNNING CHECK, CW ROTATION [2.14] INLET PORT D 76.6 [3.02] 12.7 [.50] 55.3 [2.176] OUTLET PORT CROSS-OVER RELIEFS, CW ROTATION INLET PORT D E 76.6 [3.02] CASE DRAIN PORT 7/16-20 UNF-28 STRAIGHT THREAD O-RING PORT (PER SAE J5148) 9.2 [.36] 4.1 [.16] 12.7 [.50] 55.3 [2.176] 3.5 [.14] OUTLET PORT [4.28] INLET PORT DISPLACEMENT cm 3 in D MAX. mm in [3.69] [3.75] [3.81] [3.92] [4.03] [4.38] [4.61] E mm in [3.25] [3.31] [3.36] [3.48] [3.59] [3.94] [4.17] 13

14 WM600 Hydraulic Motor Each WM600 Series Motor option has been assigned an order code which is listed in the tables below. Configure the desired options as shown in the example model code to the right. DESIGN CODE STANDARD MOTOR SEAL MATERIAL DISPLACEMENT ROTATION FLANGE SHAFT PORT VALVE OPTION RELIEF VALVE SETTING EXAMPLE WM06A1 100 R 02 EA 101 FC R35 Your Options WM06A1 2. SEAL MATERIAL una V Viton C Combination of oth 3. DISPLACEMENT Cm. 3 In * * * * * * Case drain port is required for displacements 6-12 cc. 7. STANDARD PORTING DISP. SIDE REAR ORDER PORT PORT CODE CODE CODE DESCRIPTION SAE Straight Thread (7/8-14,3/4-16) SPP Straight Thread (G1/2, G3/8) N/A European 4-olt Flange (20,15) Note: Above are standard offerings. For other porting options, please contact factory. 8. VALVE OPTIONS FC Inlet Relief Valve GE Overrunning Check Valve FD Cross-Over Relief Valves with Case Drain N Not Applicable 9. RELIEF VALVE SETTINGS 4. ROTATION irotational (Case Drain) C irotational (Check Valves) R Clockwise (No Case Drain) E Clockwise (With Case Drain) L Counter Clockwise (No Case Drain) W Counter Clockwise (With Case Drain) 5. MOUNTING FLANGES 02 SAE AA 2-olt (Dry Mount) 03 SAE A 2-olt (Dry Mount) 22 SAE AA 2-olt (Wet Mount) 33 SAE A 2-olt (Wet Mount) 6. DRIVE SHAFTS AA SAE AA Straight Shaft 1/2 Dia. CA SAE Straight Shaft 5/8 dia. EA SAE AA Spline (9 Tooth) FA SAE A Spline (9 Tooth) LA SAE A Tapered (1:8) R** ** Relief pressure divided by 100. Available in 100 PSI increments to 4000 PSI. Example: R35 = 3500 PSI NN Not Applicable Note: Relief valve setting is defined at.25 GPM full bypass. All motors require a minimum 25-piece order with the exception of those options designated with + (100-piece minimum). A selected number of distributor stock motors are available with no minimum order quantity. The right to modification for technical improvements is reserved. Printed in USA. 14

15 WM900 Flange Options For its displacement and pressure range, the WM900 family features one of the most compact envelopes available from any manufacturer. Standard international mounting flange options are outlined below. Dimensions shown outside of brackets are metric units. See page 17 for dimensional chart showing X and Y dimensions. SAE A 2-OLT ORDER CODE [3.783] MAX. 32 [1.26] R 12 [.472] INLET 133 [5.24] MAX. CW ROTATION [4.189] (For counterclockwise rotation inlet and outlet are reversed.) OUTLET [.447] [.432] [3.250] [3.248] [.252] [.232] 13.5 [.53] Y X MAX [.46] [.44] 16 [.63] R 12.3 [.48] MIN. 88 [3.46] MAX [2.74] 107 [4.21] MAX. SAE 2-OLT ORDER CODE [6.97] MAX. X MAX. CW ROTATION 12.5 [.492] Y 88 [3.46] MAX. 25 [.984] 121 [4.76] MAX [4.000] [3.998] 107 [4.21] MAX. R 14 [.551] [.573] [.558] 16 [.63] 69.2 [2.726] INLET 146 [5.75] OUTLET [.382] [.362] THROUGH OLT (50.0 mm Pilot) ORDER CODES 10 & 11 * 60 [2.362] 14 [.55] CW ROTATION 37.7 [1.48] MAX [.457] [.445] [1.9677] [1.9660] [.287] [.279] Y X Max. 16 [.63] INLET 60 [2.362] OUTLET * Cannot be used with Shaft Q. Use M screws with lockwashers. Torque screws to Nm [ lb. in.] 15

16 WM900 Reinforced Flange Options REINFORCED FRONT EARING MEDIUM DUTY ORDER CODE 001M Allowable Radial Load n = rpm L H= hours w/o axial force with axial force of 100 dan REINFORCED FRONT EARING HEAVY DUTY ORDER CODE 001V Allowable Radial Load n = rpm L H= hours w/o axial force with axial force of 130 dan 16

17 WM900 Dimensions & Weights See dimensional drawings on page 15 which accompany the dimensional chart below. Dims. & Weights with Dims. & Weights with Flange Options 03 & 05 Flange Options 10 & 11 Displacement X Y (To Port Approx. X Y (To Port Approx. cm 3 in 3 Max. Centerline) Wt./ kg. [lbs.] Max. Centerline) Wt. kg. [lbs.] [3.65] [1.732] [7.9] [3.55] [1.634] [7.0] [3.74] [1.791] [8.1] [3.64] [1.693] [7.2] [3.85] [1.850] [8.3] [3.75] [1.752] [7.4] [3.94] [1.866] [8.4] [3.84] [1.780] [7.6] [4.09] [1.969] [8.8] [3.99] [1.870] [7.9] [4.23] [2.02] [9.0] [4.13] [1.925] [8.1] [4.38] [2.114] [9.2] [4.28] [2.016] [8.3] [4.61] [2.228] [9.6] [4.52] [2.130] [8.8] [4.88] [2.346] [10.1] [4.78] [2.248] [9.2] [4.9] [2.37] [10.3] [4.8] [2.27] [9.4] 17

18 WM900 Shaft Options STRAIGHT SHAFT SAE A ORDER CODE A 4.75 x 4.75 x 22.2 [.187 x.187 x.875] KEY [1.28] [1.24] (SEE NOTE 1 ELOW) STRAIGHT SHAFT SAE A ORDER CODE CA 3.97 x 3.97 x [.156 x.156 x.75] KEY [.698] [.688] [1.28] [1.24] (SEE NOTE 1 ELOW) [.836] [.826] [.750] [.749] [1.03] [1.01] [.625] [.624] [.95] [.93] SAE A SPLINE ORDER CODE FA SAE A SPLINE ORDER CODE GA [.95] [.93] (SEE NOTE 1 ELOW) [1.28] [1.24] [.72] [.71] [.95] [.92] [1.23] [1.22] [1.51] [1.47] (SEE NOTE 1 ELOW) [.608] [.603] EXTERNAL INVOLUTE SPLINE 16/32 DP, 9 TEETH, FLAT ROOT, SIDE FIT SAE A TAPERED ORDER CODE LA 1/2-20 UNF-2 HEX NUT TORQUE Nm [ L. FT.] SPRING LOCKWASHER (ANSI ) [.635] [.615] [.73] [.71] [1.74] [1.70] 1:8 TAPER (SEE NOTE 1 ELOW) [.696] [.680] #505 WOODRUFF KEY (ANSI R1978) #505 KEY WIDTH: 3.983/3.945 [.1568/.1553] [.084] [.074] [.733] [.728] Note 1: EXTERNAL INVOLUTE SPLINE 16/32 DP, 11 TEETH, FLAT ROOT, SIDE FIT Dimension represents shaft extension for flange Options 03 & 05. For Through olt Flange Options 10 and 11, add 2.5 mm (.098 in.) to the min. & max. shaft extension shown. 18

19 WM900 Radial/Axial Loads ALLOWALE RADIAL LOAD AND AXIAL LOAD AT DRIVE SHAFT (W/O REINFORCED FRONT EARING) Allowable radial load P S dependent on direction of force related to motor for counter clockwise rotation, code L. Allowable radial load P S dependent on direction of force related to motor for clockwise rotation, code R. P T P S Maximum allowable axial force for both directions P T = 700 N (157 lbf) at viscosity of 10 cst (59 SSU). Sum of P T + P S does not exceed 1050 N (236 lbf) if appear simultaneously. Radial pre-load used at V-belt drive is not permissible for fluid motors w/o reinforced front bearing. * 27.5 for flange options 10/11. Size Curve P S 1 Curve P S 2 < p (bar/psi) > p (bar/psi) 060-6,0cc 276/ ,0cc 276/ ,0cc 276/ ,0cc 200/ / ,0cc 200/ / ,0cc 160/ / ,0cc 160/ / ,0cc 125/ / ,0cc 100/ /

20 WM900 Shaft Seal Capabilities Outlet pressure on a uni-directional motor or case drain pressure on a bi-rotational motor must not exceed seal pressure ratings. Important Note: The data below shows maximum values and cannot be used concurrently, e.g. the maximum operating pressure depends on material type, shaft speed and temperature. Contact your Concentric representative for additional information. Standard una Standard Viton High Pressure Viton Arctic Viton Max. Pressure PSI (ar) Cont. Inter. 44 (3) 58 (4) 58 (4) 73 (5) 87 (6) 116 (8) 87 (6) 116 (8) Temperature o F ( o C) Min. Max. -22 (-30) 176 (80) -4 (-20) 221 (105) -4 (-20) 221 (105) -18 (-28) 221 (105) WM900 Performance 100 SSU 20

21 Installation Information FLUIDS - Most premium grade petroleum base fluids can be used with WM900 Motors. Optimum operating viscosity is cst ( SSU) at maximum rated speed. Minimum operating viscosity is 10 cst (59 SSU). Maximum operating viscosity is 750 cst (3409 SSU). Maximum cold start viscosity is 2000 cst (9091 SSU). Contact Concentric for additional information regarding the W900 performance using other fluids. FILTRATION - Proper filtration is critical to the trouble free operation of any hydraulic system. For optimum motor life at maximum pressure ISO 4406/1986 ( 18/14) is recommended. A 10-micron filter sized to accommodate full system return flow is recommended for most operating environments. PERFORMANCE DATA - The motors will rotate also at differential pressure p<25 bar according to actual conditions. However, for specified motor performance data a continuous differential pressure of p>25 bar is required from inlet to outlet. Motors specified for only one direction with internal drain cannot be loaded at their outlet port by back pressures which exceed shaft seal capabilities (see page 20). If these pressure limits cannot be met, you must use bi-directional motors with external drain. For the external drain port, the above mentioned back-pressure limits are still valid. It is recommended that case drain lead directly to the oil reservoir. Do not connect it to the return line with filters or manifolds because of possible back-pressure peaks. The bi-directional ( ) motors have an external drain port as standard, the above mentioned back-pressure limits are also valid for these motors. TESTING - Product has been tested to 1,000,000 cycles at p I. Intermittent pressure p II is permitted at max. 20 sec loaded following 10 sec minimum unloaded. Product has been tested to 500,000 cycles at p III. Above represents performance, which can be expected from units incorporating flange port styles. Threaded side ports can affect the fatigue lifetime of motor housings. Do not use fittings with metal sealing edge. Do not overtorque the fitting. CAUTION - The peak pressure and rated pressure are for motors incorporating flanged port styles only. Whenever threaded ports are needed, a de-rated pressure has to be considered. Consult a Concentric representative to verify compliance with high pressure applications using threaded ports in pumps or motors. WM900 Valve Options The schematic drawings shown below illustrate standard valve options offered on the WM900 hydraulic motors. FA Inlet Relief Valve GF Overruning Check Valve FD Cross Over Relief Valves w/case Drain NOTE: Check Valves are included when Option C in Section 4 of the model code on page 23 is selected. OPTIONS FA GF FD DESCRIPTION Inlet Relief Valve Overrunning Check Valve Cross-Over Relief Valves w/case Drain 21

22 WM900 Valve Option Dimensions The drawings below depict the overall dimensions for the valve options specified on page 21. CARTRIDGE RELIEF VALVE, CW ROTATION OVER-RUNNING CHECK, CW ROTATION CROSS-OVER RELIEFS, CW ROTATION 22 DISPLACEMENT CM 3 IN FOR OVERRUNNING CHECK & CROSS-OVER RELIEF VALVES AOVE FLANGES 3 & [4.94] [5.06] [5.17] [5.23] [5.41] [5.52] [5.70] [5.93] [6.17] [6.22] D MAX. FLANGES 10 & [4.84] [4.96] [5.07] [5.13] [5.31] [5.43] [5.60] [5.83] [6.07] FOR CARTRIDGE RELIEF VALVE AOVE [4.04] [4.13] [4.24] [4.33] [4.48] [4.62] [4.77] [5.00] [5.27] [6.13] [5.29] E (TO PORT CENTERLINE) FLANGE OPTION 3 & [4.01] [4.12] [4.24] [4.30] [4.47] [4.59] [4.67] [5.00] [5.23] [5.29] FLANGE OPTIONS 10 & [3.91] [4.03] [4.14] [4.20] [4.38] [4.49] [4.67] [4.90] [5.13] [5.19]

23 WM900 Fluid Motor Each WM900 Series Fluid Motor option has been assigned an order code which is listed in the tables below. Configure the desired options as shown in the example model code to the right. DESIGN CODE STANDARD MOTOR SEAL MATERIAL DISPLACEMENT ROTATION EXAMPLE WM09A1 060 R 02 A 101 FA R35 001M Your Options WM09A1 FLANGE SHAFT PORT VALVE OPTION RELIEF VALVE SETTINGS REINFORCED FLANGE OPTIONS 1. DESIGN CODE WM09A1 - Single Motor WM09A2 - Double Motor WM09A3 - Triple Motor WM09A4 - Quadruple Motor 2. SEAL MATERIAL A Arctic + una V Viton H High Pressure Viton 3. DISPLACEMENT Cm. 3 In STANDARD PORTING DISP. SIDE REAR ORDER PORT PORT CODE CODE CODE DESCRIPTION SAE Straight Thread (7/8-14,3/4-16) SAE Straight Thread (1-1/16-12,7/8-14) SAE Straight Thread (1-5/16-12,1-1/16-12) SPP Straight Thread (G3/4,G1/2) SPP Straight Thread (G1,G3/4) N/A SAE Split Flange (3/4,1/2) N/A SAE Split Flange (1.0,3/4) N/A Metric Split Flange (19,23) N/A Metric Split Flange (25,19) N/A European 4-olt Flange (20,15) N/A European 4-olt Flange (26,18) Note: Above are standard offerings. For other porting options, please contact factory. Rear inlet port is not available with any valve option. Side inlet must be used on all valve options. 4. ROTATION C R E L W irotational (Case Drain) irotational (Check Valves/Case Drain) Clockwise (No Case Drain) Clockwise (With Case Drain) Counter Clockwise (No Case Drain) Counter Clockwise (With Case Drain) 5. MOUNTING FLANGES 03 SAE A 2-olt 05 SAE 2-olt 10 Through olt (50.0 mm Pilot) (Non-Tang) + 11 Same as 10, but opposite bolt pattern + 6. DRIVE SHAFTS A SAE A Straight Shaft 3/4 Dia. CA SAE Straight Shaft 5/8 dia. FA SAE A Spline (9 Tooth) GA SAE A Spline (11 Tooth) LA SAE A Tapered (1:8) 8. VALVE OPTIONS FA GF FD N Inlet Relief Valve Overrunning Check Valve Cross-over Relief Valves w/case Drain Not Applicable 9. RELIEF VALVE SETTINGS R** ** Relief pressure divided by 100. Available in 100 PSI increments to 4000 PSI. Example: R35 = 3500 PSI NN Not Applicable Note: Relief valve setting is defined at.25 GPM full bypass. 10. REINFORCED MOUNTING FLANGE OPTIONS 001M Reinforced Front earing Medium Duty + 001V Reinforced Front earing Heavy Duty + This catalog is intended for general reference only. Concentric will not accept responsibility for any catalog errors and reserves the right to modify its products without prior notice. Consult factory for specific application information. The right to modification for technical improvements is reserved. All trademarks in this material are properties of their respective owners. Printed in USA All motors require a minimum 25-piece order with the exception of those options designated with + (100-piece minimum). A selected number of distributor stock motors are available with no minimum order quantity. 23

24 WM1500 FLANGE OPTIONS For its displacement and pressure range, the WM1500 family features one of the most compact envelopes available from any manufacturer. Standard international mounting flange options are outlined below. Dimensions shown outside of brackets are metric units. See page 25 for dimensional chart showing X and Y dimensions. SAE A 2-OLT ORDER CODE 04 X MAX [4.188] CW ROTATION [.252] [.232] Y 111 [4.343] MAX. 136 [5.323] MAX [.437] 96.8 [3.811] INLET [5.128] MAX. OUTLET [3.250] [3.248] 20.3 [.799] 13 [.512] 2 [.079] 87.6 [3.449] (For counterclockwise rotation inlet and outlet are reversed.) SAE 2-OLT ORDER CODE [6.90] MAX. CW ROTATION [.555] Y X MAX. 111 [4.343] MAX. 136 [5.323] MAX. 25 [.98] [4.79] MAX. R 14 [.551] [.572] [.557] [4.000] [3.998] 20.3 [.799] INLET 146 [5.748] OUTLET 9.70 [.382] 9.19 [.362] 87.6 [3.449] (For counterclockwise rotation inlet and outlet are reversed.) 24

25 WM1500 Dimensions & Weights ** * NOTE: For port code options 05 & 06, subtract 2 mm from the port centerline dimension on the 19 cc displacement only. NOTE: For port code options 05 & 06, subtract 2 mm from the port centerline dimension on the 28 cc displacement only. (See dimensional drawings on page 24.) Dims. & Weights with Dims. & Weights with Flange Option 04 Flange Options 05 Displacement X Y (To Port Approx. X Y (To Port APPROX. CM 3 IN 3 Max. Centerline) Wt. kg. [lbs.] Max. Centerline) Wt. kg. [lbs] [5.98] * [3.52] [18.62] [4.90] * [2.49] [17.73] [6.15] [3.60] [19.05] [5.07] [2.57] [18.14] [6.24] [3.64] [19.27] [5.15] [2.62] [18.35] [6.35] [3.70] [19.59] [5.27] [2.68] [18.66] [6.56] ** [3.80] [20.12] [5.48] ** [2.78] [19.16] [6.76] [3.91] [20.66] [5.68] [2.88] [19.68] [7.01] [4.83] [21.32] [5.93] [3.00] [20.30] [7.25] [4.15] [21.97] [6.17] [3.13] [20.92] WM1500 Shaft Options See additional shaft options on page 26. STRAIGHT SHAFT SAE A ORDER CODE A STRAIGHT SHAFT SAE ORDER CODE DA 4.75 x 4.75 x 22.2 [.187 x.187 x.875] KEY [1.28] [1.24] 6.35 x 6.35 x 21.6 [.250 x.250 x.852] KEY [1.32] [1.31] [1.63] [1.59] [.836] [.826] [.750] [.749] [.948] [.928] [.985] [.975] [.875] [.874] 25

26 WM1500 Shaft Options (cont.) SAE A 9T SPLINE ORDER CODE FA SAE A 11T SPLINE ORDER CODE GA [.95] [.93] [1.28] [1.24] [.72] [.71] [.948] [.921] [1.23] [1.22] [1.52] [1.48] [.608] [.603] EXTERNAL INVOLUTE SPLINE 16/32 DP, 9 TOOTH, FLAT ROOT, SIDE FIT [.733] [.728] EXTERNAL INVOLUTE SPLINE 16/32 DP, 11 TOOTH, FLAT ROOT, SIDE FIT SAE 13T SPLINE ORDER CODE KA SAE TAPERED (1:8) ORDER CODE U [.826] [.807] [.858] [.853] [1.32] [1.31] [1.64] [1.60] EXTERNAL INVOLUTE SPLINE 16/32 DP, 13 TOOTH FLAT ROOT, SIDE FIT [.92] [.90] 5/8-18 UNF-2A HEX. NUT TORQUE Nm. [ L. FT.] [.885] [.865] [2.37] [2.33] [1.135] [1.115] #807 WOODRUFF KEY (ANSI R1978) #807 KEY WIDTH: 6.363/6.317 [.2505/.2487] [.130] [.120] 1:8 TAPER 26

27 WM1500 Radial/Axial Load ALLOWALE RADIAL LOAD AND AXIAL LOAD AT DRIVE SHAFT (W/O REINFORCED FRONT EARING) Allowable radial load P S dependent on direction of force related to motor for counter clockwise rotation, code L. Allowable radial load P S dependent on direction of force related to motor for clockwise rotation, code R. MAXIMUM FLUID MOTOR AXIAL LOADS Maximum allowable axial force for both directions P T = 1200 N (270 lbf) at viscosity of 11 cst (64 SSU). Sum of P T + P S does not exceed 1800 N (405 lbf) if appear simultaneously. Radial pre-load used at V-belt drive is not permissible for fluid motors w/o reinforced front bearing. Size Curve P S 1 Curve P S 2 < p (bar/psi) > p (bar/psi) cc 200/ cc 160/ / cc 125/ / cc 100/ /

28 WM1500 Shaft Seal Capabilities Outlet pressure on a uni-directional motor or case drain pressure on a bi-rotational motor must not exceed seal pressure ratings. Important Note: The data below shows maximum values and cannot be used concurrently, e.g. the maximum operating pressure depends on material type, shaft speed and temperature. Contact your Concentric representative for additional information. Standard una Standard Viton High Pressure Viton Arctic Viton Max. Pressure PSI (ar) Cont. Inter. 44 (3) 58 (4) 44 (3) 58 (4) 73 (5) 102 (7) 73 (5) 102 (7) Temperature o F ( o C) Min. Max. -22 (-30) 176 (80) -4 (-20) 221 (105) -4 (-20) 221 (105) -18 (-28) 221 (105) WM1500 Performance 100 SSU 28

29 Installation Information FLUIDS - Most premium grade petroleum base fluids can be used with WM1500 Motors. Optimum operating viscosity is cst ( SSU) at maximum rated speed. Minimum operating viscosity is 10 cst (59 SSU). Maximum operating viscosity is 750 cst (3409 SSU). Maximum cold start viscosity is 2000 cst (9091 SSU). Contact Concentric for additional information regarding the W1500 performance using other fluids. FILTRATION - Proper filtration is critical to the trouble free operation of any hydraulic system. For optimum motor life at maximum pressure ISO 4406/1986 ( 18/14) is recommended. A 10-micron filter sized to accommodate full system return flow is recommended for most operating environments. PERFORMANCE DATA - The motors will rotate also at differential pressure p<25 bar according to actual conditions. However, for specified motor performance data a continuous differential pressure of p>25 bar is required from inlet to outlet. Motors specified for only one direction with internal drain cannot be loaded at their outlet port by back pressures which exceed shaft seal capabilities (see page 28). If these pressure limits cannot be met you must use bi-directional motors with external drain. For the external drain port the above mentioned back-pressure limits are still valid. It is recommended that case drain lead directly to the oil reservoir. Do not connect it to the return line with filters or manifolds because of possible back-pressure peaks. The bi-directional ( ) motors have an external drain port as standard, the above mentioned back-pressure limits are also valid for these motors. TESTING - Product has been tested to 1,000,000 cycles at p I. Intermittent pressure p II is permitted at max. 20 sec loaded following 10 sec minimum unloaded. Product has been tested to 500,000 cycles at p III. Above represents performance, which can be expected from units incorporating flange port styles. Threaded side ports can affect the fatigue lifetime of motor housings. Do not use fittings with metal sealing edge. Do not overtorque the fitting. p I p II p CAUTION - The peak pressure and rated pressure are for motors incorporating flanged port styles only. Whenever threaded ports are needed, a de-rated pressure has to be considered. Consult a Concentric representative to verify compliance with high pressure applications using threaded ports in pumps or motors. 29

30 WM1500 Valve Options The schematic drawings shown below illustrate standard valve options offered on the WM1500 hydraulic motors. OPTIONS FA GF DESCRIPTION Inlet Relief Valve Overrunning Check Valve FA Inlet Relief Valve GF Overruning Check Valve WM1500 Valve Option Dimensions The drawings below depict the overall dimensions for the valve options shown above. CARTRIDGE RELIEF VALVE, CW ROTATION E D 110 [4.33] [5.63] 75.5 [2.97] 20.3 [.80] OUTLET PORT INLET PORT OVER-RUNNING CHECK, CW ROTATION D 110 [4.33] 135 [5.31] 20.3 [.80] OUTLET PORT INLET PORT 30 DISPLACEMENT CM 3 IN FLANGE OPTION [7.35] [7.51] [7.60] [7.72] [7.92] [8.13] [8.37] [8.61] D MAX. FLANGE OPTIONS [6.30] [6.47] [6.55] [6.67] [6.88] [7.08] [7.32] [7.57] E (TO PORT CENTERLINE) FLANGE OPTION [5.96] [6.12] [6.21] [6.33] [6.53] [6.74] [6.98] [7.22] FLANGE OPTIONS [4.92] [5.08] [5.17] [5.29] [5.49] [5.70] [5.94] [6.19]

31 WM1500 Hydraulic Motor Each WM1500 Series Motor option has been assigned an order code which is listed in the tables below. Configure the desired options as shown in the example model code to the right. DESIGN CODE STANDARD MOTOR SEAL MATERIAL DISPLACEMENT ROTATION EXAMPLE WM15A1 380 R 04 A 104 FA R35 Your Options WM15A1 FLANGE SHAFT PORT VALVE OPTION RELIEF VALVE SETTING 2. SEAL MATERIAL A Arctic Viton + una V Viton H High Pressure Viton 3. DISPLACEMENT Cm. 3 In ROTATION C R E L W irotational (Case Drain) irotational (Check Valves/Case Drain) Clockwise (No Case Drain) Clockwise (With Case Drain) Counter Clockwise (No Case Drain) Counter Clockwise (With Case Drain) 7. STANDARD PORTING DISP. SIDE REAR ORDER PORT PORT CODE CODE CODE DESCRIPTION SAE Straight Thread (1-5/16-12,1-1/16-12) SAE Straight Thread (1-5/8-12,1-5/16-12) SPP Straight Thread (G1,G3/4) SPP Straight Thread (G1-1/4,G1) N/A SAE Split Flange (1.0,3/4) N/A SAE Split Flange (1-1/4,1.0) N/A Metric Split Flange (25,19) N/A Metric Split Flange (32,25) N/A European 4-olt Flange (26,18) Note: Above are standard offerings. For other porting options, please contact factory. 8. VALVE OPTIONS FA GF N Inlet Relief Valve Overrunning Check Valve Not Applicable 9. RELIEF VALVE SETTINGS R** ** Relief pressure divided by 100. Available in 100 PSI increments to 4000 PSI. Example: R35 = 3500 PSI NN Not Applicable Note: Relief valve setting is defined at.25 GPM full bypass. 5. MOUNTING FLANGES 04 SAE A 2-olt 05 SAE 2-olt 6. DRIVE SHAFTS A SAE A Straight Shaft 3/4 Dia. DA SAE Straight Shaft 7/8 Dia. FA SAE A Spline (9 Tooth) GA SAE A Spline (11 Tooth) KA SAE Spline (13 Tooth) U SAE Tapered (1:8) All motors require a minimum 25-piece order with the exception of those options designated with + (100-piece minimum). A selected number of distributor stock motors are available with no minimum order quantity. This catalog is intended for general reference only. Concentric will not accept responsibility for any catalog errors and reserves the right to modify its products without prior notice. Consult factory for specific application information. The right to modification for technical improvements is reserved. All trademarks in this material are properties of their respective owners. Printed in USA

32 FM15 FLANGE OPTIONS For its displacement and pressure range, the FM15 family features one of the most compact envelopes available from any manufacturer. Standard international mounting flange options are outlined below. Dimensions shown outside of brackets are metric units. See page 25 for dimensional chart showing X and Y dimensions. SAE 2-OLT ORDER CODE [1.18] 27.6 [1.09] D E 73 [2.88] [5.75] [4.92] TANK PORT [4.54] 23.1 [.91] PRESSURE PORT 9.4 [.37] PRESSURE PORT Ø [4.00] [6.89] ROTATION Ø 14.3 [.56] FM15 Dimensions & Weights NOTE: For port code options 05 & 06, subtract 2 mm from the port centerline dimension on the 19 cc displacement only. ** * (See dimensional drawing above.) NOTE: For port code options 05 & 06, subtract 2 mm from the port centerline dimension on the 28 cc displacement only. Dims. & Weights 32 Displacement X Y (To Port Approx. CM 3 IN 3 Max. Centerline) Wt. kg. [lbs.] [5.98] * [3.52] [18.62] [6.15] [3.60] [19.05] [6.24] [3.64] [19.27] [6.35] [3.70] [19.59] [6.56] ** [3.80] [20.12] [6.76] [3.91] [20.66] [7.01] [4.83] [21.32] [7.25] [4.15] [21.97] Concentric A-FLUID MOTORS-US

33 FM15 Shaft Options STRAIGHT SHAFT SAE A ORDER CODE A 4.75 x 4.75 x 22.2 [.187 x.187 x.875] KEY [1.28] [1.24] STRAIGHT SHAFT SAE ORDER CODE DA 6.35 x 6.35 x 21.6 [.250 x.250 x.852] KEY [1.32] [1.31] [1.63] [1.59] [.836] [.826] [.750] [.749] [.948] [.928] [.985] [.975] [.875] [.874] SAE A 9T SPLINE ORDER CODE FA SAE A 11T SPLINE ORDER CODE GA [.95] [.93] [1.28] [1.24] [.72] [.71] [.948] [.921] [1.23] [1.22] [1.52] [1.48] [.608] [.603] EXTERNAL INVOLUTE SPLINE 16/32 DP, 9 TOOTH, FLAT ROOT, SIDE FIT [.733] [.728] EXTERNAL INVOLUTE SPLINE 16/32 DP, 11 TOOTH, FLAT ROOT, SIDE FIT SAE 13T SPLINE ORDER CODE KA [.826] [.807] [.858] [.853] [1.32] [1.31] [1.64] [1.60] EXTERNAL INVOLUTE SPLINE 16/32 DP, 13 TOOTH FLAT ROOT, SIDE FIT SAE TAPERED (1:8) ORDER CODE U [.92] [.90] 5/8-18 UNF-2A HEX. NUT TORQUE Nm. [ L. FT.] [.885] [.865] [2.37] [2.33] 1:8 TAPER [1.135] [1.115] #807 WOODRUFF KEY (ANSI R1978) #807 KEY WIDTH: 6.363/6.317 [.2505/.2487] [.130] [.120] Concentric A-FLUID MOTORS-US

34 FM15 Shaft Seal Capabilities Outlet pressure on a uni-directional motor or case drain pressure on a bi-rotational motor must not exceed seal pressure ratings. Important Note: The data below shows maximum values and cannot be used concurrently, e.g. the maximum operating pressure depends on material type, shaft speed and temperature. Contact your Concentric representative for additional information. Standard una Standard Viton High Pressure Viton Max. Pressure PSI (ar) Cont. Inter. 30 (3) 58 (4) 30 (3) 58 (4) 100 (7) 150 (10.5) Temperature o F ( o C) Min. Max. -22 (-30) 176 (80) -4 (-20) 221 (105) -4 (-20) 221 (105) FM15 Performance 100 SSU F F 34 Concentric A-FLUID MOTORS-US

35 FM15 Valve Options The schematic drawings shown below illustrate standard valve options offered on the FM1500 hydraulic motors. OPTIONS FA GF DESCRIPTION Inlet Relief Valve Overrunning Check Valve FA Inlet Relief Valve GF Overruning Check Valve FM15 Valve Option Dimensions The drawings below depict the overall dimensions for the valve options shown above. CARTRIDGE RELIEF VALVE, CW ROTATION E D 110 [4.33] [5.63] 75.5 [2.97] 20.3 [.80] OUTLET PORT INLET PORT OVER-RUNNING CHECK, CW ROTATION D 110 [4.33] 135 [5.31] 20.3 [.80] OUTLET PORT INLET PORT DISPLACEMENT CM 3 IN FLANGE OPTION [7.35] [7.51] [7.60] [7.72] [7.92] [8.13] [8.37] [8.61] D MAX. FLANGE OPTIONS [6.30] [6.47] [6.55] [6.67] [6.88] [7.08] [7.32] [7.57] E (TO PORT CENTERLINE) FLANGE OPTION [5.96] [6.12] [6.21] [6.33] [6.53] [6.74] [6.98] [7.22] FLANGE OPTIONS [4.92] [5.08] [5.17] [5.29] [5.49] [5.70] [5.94] [6.19] Concentric A-FLUID MOTORS-US

36 FM15 Hydraulic Motor 1 (Special Seals) F3 Viton Seal Omit Standard 2 (Series) FM15 FM15 Series Fluid Motor 3 (Mount Type) S Single Shaft Seal W Wet Mount Flange (optional double shaft seal) 4 (Front Cover) 1 SAE A 2-olt Mount (Consult Factory) 2 SAE 2-olt Mount 5 (Tank Port) 1.00, SAE 4-olt Split Flange C 1.25, SAE 4-olt Split Flange D 1.50, SAE 4-olt Split Flange DM 38 mm, SAE 4-olt Metric Split Flange (M14 x 2.0 threads) V #16 SAE (1 5/16-12) O-Ring W #20 SAE (1 5/8-12) O-Ring X #24 SAE (1 7/8-12) O-Ring Contact factory for other requirements. 6 (Displacements) Cm3/In3 Cm3/In cc/1.16 in cc/2.01 in cc/1.40 in cc/2.32 in cc/1.53 in cc/2.68 in cc/1.71 in cc/3.05 in. 3 7 (Pressure Port) A.750, SAE 4-olt Split Flange 1.00", SAE 4-olt Split Flange M 25 mm, SAE 4-olt Metric Split Flange (M10 x 1.50 threads) T #12 SAE (1 1/16-12) O-Ring V #16 SAE (1 5/16-12) O-Ring Contact factory for other requirements. 8 (Rear Cover) 1 Standard single Pump Rear cover (no options) 7 Case Drain Rear Cover 10 Standard with Valving 11 Case Drain with Valving 9 (Case Drain) H #6 SAE (9/16-18) J #5 SAE (1/4-20) P #4 SAE (7/16-20) R #2 SAE (5/16-24) Omit No Case Drain 10 (Valve Type) E Relief Valve with External Drain F Relief Valve with Internal Drain GF Over-Running Check Valve HR Anti-Cav Check Valve & Relief Valve with Internal Drain JR Anti-Cav Check Valve & Relief Valve with External Drain M Normally Closed 2-Way Solenoid with Relief Valve PA Proportional Relief Valve PC Proportional Relief Valve with Anti-Cav Check Valve 11 (Relief Valve Setting) R PSI R PSI R PSI R PSI R PSI R PSI R PSI Omit N/A 12 (Coil Voltage) 13 (Termination Type) VDC DS Dual Spades VDC DG DIN Omit N/A DL (2) Lead Wires DW Leads with Weatherpack Connectors Omit N/A 14 (Shaft Seal) A Single Shaft Seal Double Shaft Seal K Double, with Excluder Outer Seal M Excluder Outer, 100 PSI Inner 15 (Drive Shaft) 1 SAE "" Straight Keyed,.875" diameter, 1.312" ext 3 Straight Keyed/Threaded 5 1:8 Tapered/Threaded (.625" - 18 UNC) 7 1:8 Tapered Keyed/Threaded (.625" - 18 UNC) 11 SAE "" 13-Tooth Spline, Major Dia. Fit 12 SAE "" 13-Tooth Spline, Flat Root - Side Fit 19 SAE "A" 9-Tooth Spline, Flat Root - Side Fit 21 SAE "" Straight Keyed, 1.00" diameter, 1.50" ext. 99 SAE "" 15-Tooth Spline, Flat Root-Side Fit Contact factory for other requirements. 16 (Port Locations) A Side Inlet / Side Outlet Side Inlet / Rear Outlet C Rear Inlet / Side Outlet D Rear Inlet / Rear Outlet 17 (Design Designation) 10 Standard (10th Design) 18 (Rotation) L Counterclockwise Rotation R Clockwise Rotation i-rotational (Consult Factory) Note: For any axial / radial load information, contact factory. 36 Concentric A-FLUID MOTORS-US

37 FM20 & FM30 UNIDIRECTIONAL HYDRAULIC MOTORS FM20 and FM30 Series motors provide excellent high speed performance in parallel circuit applications. Available with a standard 150 PSI shaft seal (optional 500 PSI seal available), these motors feature a durable cast iron construction and excellent efficiencies. A wide variety of shaft and porting options are available. FM20 Motor Dimensional Information (Wet Mounting Flange Design) Installation dimensions in inches (mm).88 [22.4] view G scale 2/ [35.8] 1.41 [35.8] 4X R.38 [9.7] INLET 2X.562 [14.3] 4X.50 [12.7] 4X R.56 [14.2] 32º R.030 max. [.76].090 [2.3].37 [9.4].50 [12.7].97 [24.6] A 1.94 [49.8] 6.23 [158.2] R 2.38 [60.5] [146.1] [73.0] 4X 2.88 [73.2] [101.6] [101.5] G 2.84 [72.1] 3.00 [76.2] ROTATION CW 2X.87 [22.1] 2X R.38 [9.7] 2X.87 [22.1].88 [22.4] 1.47 [37.3] 1.38 [35.1] OUTLET 1.47 [37.3] 1.38 [35.1] NOTE: SAE 2-bolt mounting flange shown. C 2X R.47 [11.9] 38 Model FM20W-2*7*-**61 FM20W-2*9*-**61 FM20W-2*11*-**61 FM20W-2*13*-**61 FM20W-2*15*-**61 FM20W-2*17*-**61 FM20W-2*19*-**61 FM20W-2*21*-**61 FM20W-2*24*-**61 FM20W-2*27*-**61 A mm (inch) (6.09) (6.27) (6.45) (6.64) (6.80) (6.97) (7.17) (7.34) (7.61) (7.88) mm (inch) (4.63) (4.81) (4.99) (5.18) (5.34) (5.51) (5.71) (5.88) (6.15) (6.42) For complete model description, refer to code, page 41. C mm (inch) (4.85) (5.03) (5.21) (5.40) (5.56) (5.73) (5.93) (6.10) (6.37) (6.64)

HYDRAULIC MOTORS HYDRAULIC SYSTEMS DIVISION. Outstanding Hydraulic Products, Service and Expertise, Worldwide

HYDRAULIC MOTORS HYDRAULIC SYSTEMS DIVISION. Outstanding Hydraulic Products, Service and Expertise, Worldwide HYDRAULIC MOTORS HYDRAULIC SYSTEMS DIVISION Outstanding Hydraulic Products, Service and Expertise, Worldwide Introduction to Haldex Hydraulic Motor Capability Haldex offers one of the widest selections

More information

W900 SERIES HYDRAULIC PUMP

W900 SERIES HYDRAULIC PUMP W900 SERIES HYDRAULIC PUMP HYDRAULIC SYSTEMS DIVISION Outstanding Hydraulic Products, Service and Expertise, Worldwide W900 Hydraulic Gear Pump. PRESSURE (P1) 276 BAR (4000 PSI) (P2) 300 BAR (4400 PSI).

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference

More information

Variable Displacement Pump AA10VSO

Variable Displacement Pump AA10VSO Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi

More information

Series TMM Axial Piston Motor. Technical Information

Series TMM Axial Piston Motor. Technical Information Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer

More information

ROTARY GEAR FLOW DIVIDERS

ROTARY GEAR FLOW DIVIDERS ROTARY GEAR FLOW DIVIDERS Concentric AB Innovation + Technology = Sustainability GC and D Series Rotary Gear Flow Dividers Intensifier - Combiner (European and U.S. Versions) Field-proven Concentric Hydraulic

More information

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact

More information

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY28-2662-CD/US

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY28-2662-CD/US P2/P3 Series Piston Pumps Variable Displacement zp9 Catalog HY28-2662-CD/US A3 Series P2/P3 A4 General Information General Information Series P2/P3 P2 Series The newly developed variable displacement piston

More information

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY28-2662-CD/US

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY28-2662-CD/US Series PAVC Variable Displacement Piston Pumps zp1 Catalog HY28-2662-CD/US 1 Introduction Series PAVC Quick Reference Data Chart Pump Model Displacement CM 3 /REV (IN 3 /REV) Pump Delivery *Approx. Noise

More information

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde Hydraulic Motor/Pump Series F11/F12 Fixed Displacement parker.com/pmde Series F11/F12 Torque (M) M = D x p x η hm 63 [Nm] Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5

More information

FP12 FERRA SERIES HEAVY DUTY GEAR PUMP

FP12 FERRA SERIES HEAVY DUTY GEAR PUMP FP12 FERR SERIES HEVY DUTY GER PUMP Concentric B Innovation in Hydraulics DESIGNED FOR HEVY DUTY The FERR F12 pump is a rugged two-piece pump available with displacements from 16 to 41 cc/rev and pressures

More information

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US Catalog HY15-352/US Contents Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI NEED VALVES J2A2... C8-2... Needle Valve, Cartridge Type...45/12... 42/6... 5-6 NVH81... C8-2... Needle

More information

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109 INDEX Description Page Delta Power Rotary Flow Divider, Positive Displacement (Application Data) 36 P Series, Equal Flow Two Sections 39 P Series, Equal Flow Multi-Sections 40 PM Series, Equal Flow Multi-Sections

More information

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93 Vickers Check Valves Check Valves Inline, right angle, manifold mounted, and pilot operated designs Released 9/93 645 Introduction Vickers inline, right-angle, and manifold mounted check valves are direct

More information

Check Valves Valve locator

Check Valves Valve locator Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 ()

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

PVH131/141 Variable Displacement Piston Pump - 11 Design

PVH131/141 Variable Displacement Piston Pump - 11 Design Service Data Vickers Piston Pumps PVH131/141 Variable Displacement Piston Pump - 11 Design Revised 05/01/97 M-2209-S Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque

More information

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division Parker Piston Pumps Otsego Core Competency... Piston Pumps PAVC Series : 4 displacements from 33-100 cc/r, 207 Bar, 3000 RPM PVP Series : 9 displacements from 16-140 cc/r, 250 Bar, 3000 RPM PV Plus : 12

More information

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...

More information

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711 A10VO Nominal size 18 see RD 92712 A10VO Nominal size 28...140 see RD 92711 The variable displacement axial piston pump A10VO in swashplate design was designed for hydrostatic drives in open circuits.

More information

1.Booklet. Hydraulic Motors. General Purpose MotorsR Series

1.Booklet. Hydraulic Motors. General Purpose MotorsR Series .Booklet 1.Booklet Hydraulic Motors out 2 out 1.Booklet R Geroler Element... 11 Displacements... [15] ** 75 [20] * Speed... Up to 10 RPM Pressure Bar [PSI]... 125 [1800] Cont. 165 [2400] Inter. Torque

More information

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...

More information

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement Mobile Hydraulic Pumps T6*M Denison Vane Technology, fixed displacement Contents GENERAL Series T6 Mobile, Denison Vane Pumps Features...3 Instructions...3 Minimum & maximum speeds...4 Pressure ratings...4

More information

PRODUCT CARD GEAR PUMPS AND MOTORS ORS GROUP 1 E0.14.0503.02.01 TM GEAR PUMPS AND MOTORS GROUP 1 INDEX Page 1 - GENERAL INDEX Page 2 - Features - Quick guide Page 3 - Features - General - Working conditions

More information

Dual Path Mobile Pump

Dual Path Mobile Pump Dual Path Mobile Pump Technical Manual 350 Series 350 Series Mobile Pump Introduction Single Assembly* Dual Path Assembly The 350 Series mobile pump is an advanced, closed circuit, servo controlled, axial

More information

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs. TXV - Presentation pumps with Load Sensing control variable displacement piston pumps ADVANTAGES pumps are variable displacement with pressure-flow control called Load Sensing. They self-regulate to give

More information

Vickers. Piston Pumps

Vickers. Piston Pumps Vickers Piston Pumps xial Piston Pumps Fixed and Variable Displacement PF, PF, PF PV /6, PV /, PV /9, PV and PV 9 to SE PV /6, PV /, PV /9 to DIN/ISO 39, Part G-379 Contents asic characteristicts..........................................................................................3

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI KSWA3... SW-3... Ball sert Type...9./2.... 42/6... 3 K2A... 3Z... Poppet sert Type...38/1... 3/... 4 CS41B... C4-3...

More information

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V PILOT OPERTED PRESSURE RELIEF VLVE - Series VR4V The Veljan Pressure Relief Valve series VR4V are pilot operated and wk Internal Dra on the prciple of hydraulic balancg. These valves are used to limit

More information

15/40/80CN Series Medium Pressure Filters

15/40/80CN Series Medium Pressure Filters 1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)

More information

220 Series Piston Pump Typical Applications Features and Benefits

220 Series Piston Pump Typical Applications Features and Benefits Introduction 220 Series Piston Pump Eaton s new 220 Series piston pump signifies a step change in the generation of hydraulic power. Utilizing the latest developments in hydraulic pump technology, the

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 U.S.A. Tel: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics.

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 U.S.A. Tel: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics. SPECIFICATIONS PF1000 Series Fixed Displacement Pumps Also refer to "Checkball Pump Installation and Operating Recommendations" Bulletin PSI.CB (dynexpumpinstallation.pdf) CONTACT INFORMATION USA Headquarters

More information

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications Technical Catalog PVQ10 PVQ13 PVQ20 PVQ25 PVQ32 PVQ40 PVQ45 Table of Contents Introduction......................................................................................................

More information

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where

More information

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories Pumps and Motors Conversion factors 1 kg... 2,20 lb 1 N... 0,225 lbf 1 Nm... 0,738 lbf ft 1 bar...14,5 psi

More information

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description

More information

Rexroth Hydraulic Pump A10VO Series User Manual

Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)

More information

H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions

H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions Input Shafts Option G1, ISO 3019-1, outer dia 32 mm-4 (SAE C, 14 teeth) 31.5 ±1 [1.240 ±0.039] MOUNTING FLANGE SURFACE FLANGE 127-4 PER ISO 3019-1 SPLINE DATA NUMBER OF TEETH : 14 PITCH FRACTION : 12/24

More information

HMC Series Dual Displacement Staffa Motor

HMC Series Dual Displacement Staffa Motor HMC Series Dual Displacement Staffa Motor Description The range of dual displacement motors extends from the HMC030 in 492cc/rev. to the HMC325 in 5326cc/rev. There are seven frame sizes as shown in the

More information

Fixed displacement vane pumps

Fixed displacement vane pumps Fixed displacement vane pumps RE 1335/1.5 Replaces: 11.2 1/22 Types PVV and PVQ Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 Doppelpumpe_d_ Double

More information

Hydraulic Flow Control Valves

Hydraulic Flow Control Valves Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series

More information

PVM Piston Pumps Service Manual

PVM Piston Pumps Service Manual PVM Piston Pumps Service Manual PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141 Table of Contents Service Parts Pump Description... 3 Basic pump Pump Operation Controls Types Part Identification...

More information

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................

More information

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB MONO BLOCK DIRECTIONAL CONTROL VALVE TS112TSLB TS TS212TSTSJB P T TS312TSDTSTKJ TS112TSJB FEATURES: O RG PORTS to eliminate leakage. POWER BEYOND CAPABILITY to fit your multi valve circuits. BUILT ANTI-DROP

More information

Series 40 Axial Piston Motors. Technical Information

Series 40 Axial Piston Motors. Technical Information Series 40 Axial Piston Motors Technical Information Revisions Revisions Table of Revisions Date Page Changed Rev. April 2011 34, 36 correct system pressure gauge port 7/16-20 FE August 2010 last new back

More information

PRODUCT CARD GEAR PUMPS AND MOTORS ORS GROUP 3 E0.17.0703.02.01 TM GEAR PUMPS AND MOTORS INDEX Page 1 - GENERAL INDEX Page 2 - Features - Quick guide Page 3 - Features - General - Working conditions -

More information

High Torque Vane Motors MV015, MV037, MV057, MV125

High Torque Vane Motors MV015, MV037, MV057, MV125 High Torque Vane Motors MV015, MV037, MV057, MV125 2 Unique vane crossing vane design provides maximum versatility This motor is created around the patented vane crossing vane design, a leading-edge concept

More information

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT IF IT FLOWS THE BOWIE PUMP CAN PUMP IT Bowie Industries, Inc. Bowie, TX 76230 USA Page 1 Bowie Pumps Manual General Pump Information..Page 2 300 Series Pumps.. Page 5 400 Series Pumps.Page 11 500 Series

More information

VIKING UNIVERSAL SEAL PUMPS. Heavy-Duty, Foot-Mounted Internal Gear Pumps With Multiple Seal Options. Operating Range1: Nominal Flow Rates:

VIKING UNIVERSAL SEAL PUMPS. Heavy-Duty, Foot-Mounted Internal Gear Pumps With Multiple Seal Options. Operating Range1: Nominal Flow Rates: VIKING UNIVERSAL SEAL PUMPS Section 630 Page 630.1 Issue G Heavy-Duty, Foot-Mounted Internal Gear Pumps With Multiple Options Operating Range1: Cast Iron Series 124A/AE, 4124A/AE, 4124B, 324A, 4324A, 224A/AE,

More information

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories parker.com/pmde Pumps and Motors Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft

More information

Table of Contents. M Series Variable Displacement Piston Pumps

Table of Contents. M Series Variable Displacement Piston Pumps Table of Contents M Series Variable Displacement Piston Pumps Introduction.... 3 Hydraulic System Design Calculations.... 4 Model Code Selection.... 5 Model Code Options.... 6 Specifications and Performance...

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 3 HYDRAULIC AND PNEUMATIC MOTORS The material needed for outcome 2 is very extensive

More information

Rickmeier Solutions. Gear pumps for superior Lubrication

Rickmeier Solutions. Gear pumps for superior Lubrication Rickmeier Solutions Gear pumps for superior Lubrication P U M P E N T E C H N O L O G I E #1. Introduction Position and significance of Rickmeier products Rickmeier supplies pumps, valves and systems for

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control

More information

Vane Pump & Motor Design Guide

Vane Pump & Motor Design Guide Vickers Service Guide Vane Pump & Motor Design Guide For Mobile Equipment Revised 8/98 353 Introduction Over the past twenty years, the application of hydraulics in agricultural, construction and materials

More information

Vickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment

Vickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment Vickers Vane Pumps Single and Double Vane Pumps Model Series V10, V20, V2010, and V2020 for Industrial Equipment The Power of One Eaton HANSEN GROMELLE There s a certain energy at Eaton. It s the power

More information

PUMP AND MOTOR DIVISION

PUMP AND MOTOR DIVISION INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP 1 Check model code / compare with your paper work Nameplate of the pump Ordering / Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation

More information

Machine Design II Prof. K.Gopinath & Prof. M.M.Mayuram. Module 2 - GEARS. Lecture 17 DESIGN OF GEARBOX

Machine Design II Prof. K.Gopinath & Prof. M.M.Mayuram. Module 2 - GEARS. Lecture 17 DESIGN OF GEARBOX Module 2 - GEARS Lecture 17 DESIGN OF GEARBOX Contents 17.1 Commercial gearboxes 17.2 Gearbox design. 17.1 COMMERCIAL GEARBOXES Various commercial gearbox designs are depicted in Fig. 17.1 to 17.10. These

More information

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT PM10 VRIBLE DISPLCEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C L C T L O G PM10 - Variable displacement pump POCLIN HYDRULICS OVERVIEW PM10 is a variable displacement, axial piston pump, with swashplate

More information

Char-Lynn Hydraulic Motor. Repair Information. 10 000 Series. October, 1997

Char-Lynn Hydraulic Motor. Repair Information. 10 000 Series. October, 1997 Char-Lynn Hydraulic Motor October, 1997 Repair Information Geroler Motor Two Speed 001 27 Retainer inside bore of valve plate bearingless motors only 4 15 16 3 6 35 Parts Drawing 25 2 2 1 19 17 36 40 47

More information

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM Introduction Manapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D03, D05 and D08 sandwich style valve. The NFPA D03 valve body conforms

More information

High Pressure Gear Motors KM 1

High Pressure Gear Motors KM 1 High Pressure Gear Motors KM 1 2 KRACHT GmbH Gewerbestr. 2 58791 Werdohl, Germany fon +49()23 92/935- fax +49()23 92/935 29 mail info@kracht.eu web www.kracht.eu Construction 1 5 8 9 1 2 6 4 7 3 1 Housing

More information

Denotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

Denotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY Catalog HY-5/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI HIGH FLOW VALVE FAMILY See individual catalog pages for exact specifications. WAY SPOOL TYPE GS *... X / C9-.. Position,

More information

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY17-8200/UK March 2004

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY17-8200/UK March 2004 Fixed and Variable Displacement Pumps, Motors and Accessories Catalogue HY17-8200/UK March 2004 F1 F2 T1 VP1 PTO info Accessories Conversion factors 1 kg 2.20 lb 1 N 0.225 lbf 1 Nm 0.738 lbf ft 1 bar 14.5

More information

VHO/VQ Single, Double & Triple Vane Pumps

VHO/VQ Single, Double & Triple Vane Pumps VHO/VQ Single, Double & Triple Vane Pumps Series Available: 20, 25, 30, 35, 45, 50 For Mobile and Industrial Use Cartridge Kits Available for All Sizes Same Day Shipments www.fluidynefp.com Our People

More information

Series 30000 Hose Reels

Series 30000 Hose Reels Operating Instructions and Parts List for Series 30000 Hose Reels - MANUAL DRIVEN - - POWER DRIVEN - SAFETY PRECAUTIONS Personal injury and/or equipment damage may result if proper safety precautions are

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

Axial Piston Fixed Displacement Motor A2FM

Axial Piston Fixed Displacement Motor A2FM Electric Drives and Controls Hydraulics Linear Motion and ssembly Technologies Pneumatics Service xial Piston Fixed Displacement Motor 2FM RE 91 001/07.05 1/36 Replaces: 11.04 Technical data sheet Series

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions LINDGREN-PITMAN, INC. Super Spool III Installation Instructions LINDGREN-PITMAN, INC. 2615 N.E. 5th Avenue * Pompano Beach, Florida 33064 * U.S.A. (954)943-4243 * (954)943-7877 Fax E-mail: longline@gate.net

More information

Radial piston pumps type R and RG

Radial piston pumps type R and RG Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power

More information

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:

More information

KDG3V-5/7/8, 10 Series

KDG3V-5/7/8, 10 Series Vickers roportional Valves KDG3V-5/7/8, 1 Series Single-Stage with Hydraulic ilot Operation High Flow roportional Directional Control Valves asic Characteristics Max. pressure.......... up to 35 bar (5

More information

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits. Vickers Pressure Relief Pressure Relief and Sequence Valves CG2V-6/8, 1 Series; CG5V-6/8, 2 Series Typical Section CG2V-6*W-1 relief valve Basic Characteristics Maximum pressure.......... 35 bar (5 psi)

More information

PVQ 40-B2/M2 * *** - ** * * - 10 C** *** *** * - 10/11/12/20 PVQ 45-B2/M2 * *** - ** * * - 10 C**

PVQ 40-B2/M2 * *** - ** * * - 10 C** *** *** * - 10/11/12/20 PVQ 45-B2/M2 * *** - ** * * - 10 C** Service Data Vickers Piston Pumps Low Noise Industrial Piston Pump PVQ 40-B2/M2 * *** - ** * * - 10 C** *** *** * - 10/11/12/20 PVQ 45-B2/M2 * *** - ** * * - 10 C** *** *** * - 10/11/12/20 C, CM Compensator

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM Page 1 of 19 Cat Electronic Technician 2015A v1.0 Product Status Report 2:49 PM Product Status Report Parameter Value Product ID WRK00337 Equipment ID WRK00337 Comments A01-52 C9 330D (THX37891) Parameter

More information

800-348-8467 www.fittingsunlimited.com

800-348-8467 www.fittingsunlimited.com Thread and Port Identification Guide 800-348-8467 www.fittingsunlimited.com INDEX Index... 1 Explanation of Symbols... 2 How to Measure Threads... 3-4 Metric vs English Threads... 5 North American Connections

More information

AIR OPERATED OIL PUMPS AND KITS

AIR OPERATED OIL PUMPS AND KITS PM 2 AIR OPERATED OIL PUMPS AND KITS PM 2 Oil pump, pressure ratio : 0 Double acting air operated pumps for transferring lubricants and other non-corrosive fluids. Pump includes bung adapter. New Model

More information

15/40/80CN Series Coreless Medium Pressure Filters

15/40/80CN Series Coreless Medium Pressure Filters //8CN Series Coreless Medium Pressure Filters //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment Pilot

More information

"A" Series Variable Displacement Piston Pumps Single Pump, "OBE" Type Electro-Hydraulic Proportional Pressure & Flow Control Type

A Series Variable Displacement Piston Pumps Single Pump, OBE Type Electro-Hydraulic Proportional Pressure & Flow Control Type Single Pump, "OBE" Type Electro-Hydraulic Proportional & Flow Type Input Signal for Safety valve Input Signal for Flow Amplifier Proportional Solenoid Sensor Valve Piston (S Input Voltage L) Performance

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SF-2C-115A-35 S-1AY-12D-35 SD-2C-12D-35 Features High Flow/ High Pressure: Up to 40 gpm / 5000 psi working pressure*.

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

PART 2 FORKLIFT HYDRAULIC SYSTEM

PART 2 FORKLIFT HYDRAULIC SYSTEM PART 2 FORKLIFT HYDRAULIC SYSTEM Chapter 1 Description and Operation Component Locations & Circuit Layouts 1 Hydraulic Pump 11 Control Valve 14 Valve Section Oil Flows 15 Anti-Cavitation Valve 22 Velocity

More information

Pipe Cutting and Beveling Clamshells

Pipe Cutting and Beveling Clamshells Pipe Cutting and Beveling Clamshells Who We Are One Company, Total Support, Complete Solutions For more than a century, Hydratight has provided world-class bolted joint solutions and continues to set international

More information

P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc

P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc Installation Timing Pin Location CAUTION: Before installing the injection pump, be sure that number 1 cylinder is at the Top Dead Center

More information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

Uniquely designed and engineered specifically for the pulp and paper industry.

Uniquely designed and engineered specifically for the pulp and paper industry. Universal SPU2 Series Uniquely designed and engineered specifically for the pulp and paper industry. For more than half a century, Waukesha Cherry-Burrell has been a leader in the design, manufacturing

More information

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19 Table of Contents Overview 1 Pump Disassembly 2 Control Disassembly / Reassembly 7 Pump Reassembly 13 Adjustment Procedures DR Control 19 Adjustment Procedures DRG Control 20 Adjustment Procedures DFR

More information

Vickers Vane Pumps V Series - Low Noise Vane Pumps. High Performance Intravane Pumps For Industrial Applications

Vickers Vane Pumps V Series - Low Noise Vane Pumps. High Performance Intravane Pumps For Industrial Applications Vickers Vane Pumps V Series - Low Noise Vane Pumps High Performance Intravane Pumps For Industrial Applications The Power of One Eaton HANSEN GROMELLE There s a certain energy at Eaton. It s the power

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

Vickers PVM Piston Pumps

Vickers PVM Piston Pumps Vickers PVM Piston Pumps 18-141cc 3 (1.1-8.6in 3 ) M-Series Industrial Variable Displacement M-Series Mobile Variable Displacement Table of Contents M Series Variable Displacement Piston Pumps Principles

More information

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409 Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SD-2B-115A-35 SDS-2H-12D-35 S-2B-115A-35 Features High Flow/ High Pressure: Up to 25 gpm / 5000 psi working

More information

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 GENERAL SECTION PAGE MOOG SERVO- AND PROPORTIONAL CONTROL VALVES General 2 enefits and Functionality 3 General

More information