MT4-024/MT4-230 MT8-024/MT8-230



Similar documents
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

HERZ-Thermal Actuators

T7560A,B,C Digital Wall Module

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

HCE80/HCC80/HCE80R/HCC80R

T7079A,B Solid State Remote Temperature Controllers

User Manual THR840DUK Digital Thermostat

Actuator for modulating control AME 435

Electro-Pneumatic Bus Door Control Mechanism

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Automatic control equipment for HVAC systems

T6580 FAN COIL CONTROLLER

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

T5000 T000 LCD Digital Fan Coil Thermostat

Electronic Pressure Switch EDS 300

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

Electronic Control Devices The European Product Catalogue 2007

RF 1. Contents: Connecting diagram. Detailed information:

Data sheet Thermostatic sensors type RA 2000

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

Flush-mounted room thermostats

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

ELECTRIC CENTRAL HEATING FLOW BOILER

Inwall Room Temperature Unit

Product and Application Description

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Adjustable room thermostat for heating only or cooling only systems

ACS-30-EU-EMDR-10-MOD

TAC Erie VT/VS PopTop Series Two Position Spring Return Valves

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

evohome Wireless Radiator Zoning Kit Installation & User Guide

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

RRV934. Multi-controller. Synco living

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Y7230A CO 2 Alarm System

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

DC DC CONVERTER 1000W VDC Input / 12VDC Output

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Floor Heating Warehouse.co.uk

Industrial infrared heater IR For premises with large volumes and high ceilings

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Cooling system components, removing and installing

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building.

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Kit Watt Audio Amplifier

V1810. Alwa-Kombi-4 Circulation throttle valve. Product data

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

DN05034/D. Enhanced PWM LED Dimming DESIGN NOTE

Operating Instructions. Room temperature controller

Installation and Operating Instructions for ROBA -takt Control Unit Type

Pluggable interface relays CR-P Pcb relays

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Cable Plug acc. to DIN EN , Form A

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

Combi B Alarm box. Mounting instructions

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

MAGNETOSTICTIVE TRANSDUCER

DEVIreg 330 (+5 to +45 C)

Technical Guide. Thermostats Air Conditioning

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Knob Potentiometer with Switch

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

SLIM LINE FUME HOOD MONITOR

V5001S. Kombi-S Shutoff Valve. Product specification sheet

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

RY2 miniature industrial relays

Installation Guide for Hive Active Heating

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

VU53S; VU54S; VU443A; VU444A; VU843A; VU844A Fan Coil Valves and Actuators

MOUNTING AND OPERATING INSTRUCTIONS

Addendum to the Operating Instructions

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

, User s Manual

VSO MAX HP High Flow Proportional Valve

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Transcription:

Smart-T MT4-024/MT4-230 MT8-024/MT8-230 SMLL LINER THERMOELECTRIC CTUTORS PRODUCT DT FETURES No mounting tools required (easily mounted using valve adapter) Water-protected housing design in all mounting positions Pluggable cable for easy installation and servicing uxiliary switch models for driving pumps or fans Low power models Normally-open and normally-closed models Compact design allows installation in limited space Visual indicator showing valve position and type of action (NO or NC) Noiseless operation Reliable long-term operation Overload protection (4 kv) for 230 V models PPLICTION Smart-T small linear actuators are used in room and zone applications for -controlled two-point and pulse-widthmodulated (PWM*) regulation of heating and cooling systems such as fan coil units, radiators, floor heating systems, chilled ceilings, and convectors. Fit on standard M30 x 1.5 heating/cooling valves, thermostatic radiator valves, and valve inserts for manifolds and compact radiators. Special valve adapters on request. *Recommended controllers: Excel 10 and Excel 12 controllers (use with other, non-honeywell controllers may adversely influence PWM-operation). SPECIFICTIONS Max. stroke MT4: 4 mm MT8: 8 mm Power supply MTx-024: 24 Vac/dc ± 20% MTx-230: 230 Vac +10%... -15% Stem force 90 N Opening/closing dependent on ambient temperature (see Table 3) mbient temperature max. 50 C Electrical See Table 3 on page 3. specifications Protection standard IP44 in all mounting positions Cable length 1 m, other cable lengths upon request Cable wires MTx-xxx: 2 x 0.5 mm 2 MTx-xxxS: 4 x 0.35 mm 2 Max. permissible MTx-xxxS: 5 (3) auxiliary switch current Medium temperature max. 120 C U.S. Registered Trademark EN0-0490GE51 R0208 Copyright 2008 Honeywell Inc. ll rights reserved

MT SMLL LINER THERMOELECTRIC CTUTORS ORDERING INFORMTION Table 1. ctuators order number action* additional features voltage stroke MT4-024-NC MT4-024-NO MT4-024-NC-2.5M MT4-024-NO-2.5M MT4-024LC-NC MT4-024LC-NO MT4-024S-NC MT4-024S-NO MT4-230-NC MT4-230-NO MT4-230-NC-2.5M MT4-230-NO-2.5M MT4-230LC-NC MT4-230LC-NO MT4-230S-NC MT4-230S-NO MT8-024-NC MT8-024-NO MT8-024-NC-2.5M MT8-024-NO-2.5M MT8-024LC-NC MT8-024LC-NO MT8-024S-NC MT8-024S-NO MT8-230-NC MT8-230-NO MT8-230-NC-2.5M MT8-230-NO-2.5M MT8-230LC-NC MT8-230LC-NO MT8-230S-NC MT8-230S-NO 24 Vac/dc 230 Vac/dc 24 Vac/dc 230 Vac/dc *Without power, in combination with standard 2-way valve; "" = stem extends, "" = stem retracts 4 mm 8 mm MT-CLIP MT-CLIP-TP MT-DPT-HW MT-DPT-HP MT-CLE-1.5M MT-CLE-2.5M MT-CLE-5M MT-CLE-10M EV10R HC1VEL order number Table 2. ccessories mounting clip, 10 units description mounting clip, with anti-theft protection feature, 10 units mounting adapter M30 x 1.5, 10 units mounting adapter for Herz/Polytherm valves, 10 units cable suitable for MT4-024/-230/-024LC/-0230LC and MT8-024/-230/- 024LC/-0230LC, 10 units Danfoss-R adapters, 10 units Mounting adapter for Velta compact manifold EN0-0490GE51 R0208 2

MT SMLL LINER THERMOELECTRIC CTUTORS ELECTRICL SPECIFICTIONS order number initial current* Table 3. Electrical specifications permanent current* power min. run for full nominal valve stroke * 4 mm models 8 mm models MTx-024-xx, MTx-024S-xx ~0.7 < 0.1 < 3 W 4.0 min 6.0 min MTx-024LC-xx ~0.2 < 0.05 < 2 W 6.0 min 7.5 min MTx-230-xx, MTx-230S-xx ~0.6 ** 0.014 3 W 2.5 min 3.5 min MTx-230LC-xx ~0.4 ** 0.010 2 W 3.5 min 5.5 min *ll values at nominal voltage. **verage during first 500 msec. MOUNTING NOTE: Connection leads must not touch piping (heat transfer). Fig. 1. Mounting / installation positions Fig. 2. Dismounting FUNCTION When the operating current is applied, a PTC resistor heats up a wax element. fter a delay, this wax element expands, causing stroke movement. 3 EN0-0490GE51 R0208

MT SMLL LINER THERMOELECTRIC CTUTORS Position Indicator The position indicator (the red indicator behind the window on the face of the actuator) shows the model's type of action (NO or NC) as well as the current stroke position. NC NO Fig. 3. Position indicator WIRING grün, vert, verde, green, zielony grün, vert, verde, green, zielony 230 Vac / 24 V MTx-xxxS 5 (3) braun, brun, marrone, brown, brazowy blau, bleu, blu, blue, niebieski R-T 230 Vac / 24 V Ω 3 W braun, brun, marrone, brown, brazowy blau, bleu, blu, blue, niebieski R-T 230 Vac / 24 V Ω Fig. 4. Wiring diagrams Opening and Closing Time MTx-xxx, MTx-xxxLC 3 W (MTx-xxxLC: 2 W) stroke NO NC power on off dead opening dead closing Fig. 5. Opening and closing NOTE: Opening and closing s depend upon ambient temperature and model. EN0-0490GE51 R0208 4

MT SMLL LINER THERMOELECTRIC CTUTORS Valve ction DIMENSIONS NC (normally-closed) version NO (normally-open) version NC NO NC NO H X L dimension MT4-xxx MT8-xxx W W H L X 57 42 45 6 65 Fig. 7. Dimensions (in mm) Fig. 6. Valve action Normally open: 2-way valve, - open without power; Normally closed: 2-way valve, - shut without power; NOTE: Fig. 6 is a schematic diagram showing typical valve action. ctual function can vary depending upon the individual type of valve. y using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du ois 37, Switzerland by its uthorized Representative: utomation and Control Solutions Honeywell GmbH öblinger Straße 17 D-71101 Schönaich Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc.emea.honeywell.com Subject to change without notice. Printed in Germany EN0-0490GE51 R0208