Roofing. Sarnafil S 327-15EL. Polymeric membrane for roof waterproofing. Product Description



Similar documents
Polymeric membrane for roof waterproofing

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

SARNAFIL WATERPROOFING MEMBRANES SARNAFIL ADHERED ROOF WATERPROOFING MEMBRANES

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

SIKA TANKING MEMBRANES SIKAPROOF A MEMBRANES

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Division 9. SignaFlor Pad and Pour Flooring System

Low viscosity, solvent free elastic adhesive for wood flooring

APIB Test Specification No. 09 WATERPROOFING MEMBRANES SWISS HAIL IMPACT PROTECTION REGISTER HSR / 07-15en Version 1.

How To Test A Wrap N Drain X Dampproofing System

PVC ROOFING SYSTEMS BUILDING SOLUTIONS A SINGLE SOURCE FOR SINGLE-PLY ROOFING

Only by learning from the past, we can meet the demands of the future. Rhepanol fk

4 Product Data Sheets

SikaProof A Technology

Colorado State University. Durrell Center Roof Repair

Firestone RubberGard The EPDM reference

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

Building Owners Guide to a Duro-Last System!

European Technical Approval ETA 12/0419

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Roofing hand tools overview 47

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Elastic, 1-part-polyurethane, liquid waterproofing membrane

G VYCOR DECK PROTECTOR

RHEPANOL RHEPANOL FK ROOF COVERING SYSTEM

Mezzanine. Technical manual

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

RENOLIT ROOF WATERPROOFING MEMBRANES ALKORPLAN ROOF WATERPROOFING MEMBRANES

FLAGON PVC SINGLE-PLY ROOF WATERPROOFING SYSTEMS FLAGON SFc, SFb AND SV ROOF WATERPROOFING SYSTEMS

DENSO WATERPROOFING SYSTEMS

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

PAAM COMMERCIAL PRIVATE LIMITED

ALUMASC ROOF WATERPROOFING MEMBRANES EUROROOF MASTERGOLD ROOF WATERPROOFING MEMBRANE

Peel & Seal Self-Stick Roofing Solutions

Fosroc Proofex Engage

WATERPROOFING FOR CONCRETE STRUCTURES

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

ITEM THERMOPLASTIC MEMBRANE ROOFING

INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group

SEAMS SEAMING USING SEAM TAPE

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

WATERPROOFING SikaProof -A TECHNOLOGY

Fire Barrier Duct Wrap 15A

Roofing Applicator Handbook

Commercial Roof Management

CHAPTER 7: Building Systems ROOFING SYSTEMS

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

April 25, 2014 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

AND MEMBRANES ROOFING UNDERLAYS.

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING General Materials Equipment...

SECTION PVC SINGLE PLY ROOFING

Product Data Sheet ROCKPANEL Rockclad

FATRA ROOF COVERING SYSTEMS FATRAFOL FF807 AND FATRAFOL FF807/V ROOF COVERING SYSTEMS

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

SECTION GUARDA SECURITY WINDOW SCREENS


1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

Test Report. Root Penetration Resistance Test. of Waterproofing Membrane for Green Roof System

RECOATING AND RENEWING SPF ROOFING SYSTEMS

THERMOPLASTIC-POLYOLEFIN ROOFING (TPO) Data Center

Epdm Flat Roofing Systems

Rooflight INSTALLATION INSTRUCTIONS

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

The existing roof angle change terminations and flashings when sound and intact can be reused.

WATERPROOFING SIKAPLAN MEMBRANE SYSTEMS FOR BASEMENTS TECHNOLOGY & CONCEPTS

peel adhesion 2 breaking load 4 rolling ball 6 shear adhesion 7 carton test 9 summary test methods 11

Solvent Cementing Instructions For Plastic Pipe & Fittings

BAUDER BITUMINOUS ROOFING SYSTEMS BAUDERFLEX ROOF WATERPROOFING SYSTEMS

COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE

Asphalt Shingle Application Requirements

SECTION THERMOPLASTIC MEMBRANE ROOFING

INSTALLATION GUIDE. americanwick.com WICK (9425)

Roofing Systems. New Applications / Re-Roofing / Maintenance

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Isola Steel Gutters Strength and design for extreme climate!

Technical Data Sheet February 2014

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

ALWITRA ROOFING MEMBRANES EVALON AND EVALON V ROOFING SHEETS

1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.

High-performance, 2-part epoxy anchoring adhesive

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Multi-layer Insulation Blanket for Roofs

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Transcription:

Roofing Product Data Sheet Edition 02.2015 Identification no: 02 09 01 01 201 0 150000 Version no. 04 Sarnafil S 327-15EL Polymeric membrane for roof waterproofing Product Description Sarnafil S 327-15EL (thickness 1.5 mm) is a Polyester reinforced, multi-layer, synthetic roof waterproofing sheet based on premium-quality polyvinyl chloride (PVC) containing ultraviolet light stabilizers and flame retardant according to EN 13956. Sarnafil S 327-15EL is a hot air weldable roof membrane formulated for direct exposure and designed to use in all global climatic conditions. Sarnafil S 327-15EL is produced with an integral polyester scrim reinforcement for high strength used within the Sarnafast spot fastening system and Sarnabar linear mechanically fastened system. Sarnafil S 327-15EL has a unique lacquer coating applied to the top of the membrane to resist staining from airborne dirt and pollutants. Roofing Uses Characteristics / Advantages Sarnafil S 327-15EL has no built-in stress at the time of production and has a fully encapsulated reinforcement with no risk to delamination or water-wicking. Sarnafil S 327-15EL can be produced also in a variety of colours in smaller quantities. Waterproofing membrane for: Mechanically fastened roofs Outstanding resistance to weathering, including permanent UV irradiation Excellent flexibility in cold temperatures No built-in stress at the time of production High dimensional stability High water vapour permeability Excellent weldability No risk of delamination or water-wicking Can be produced also in a variety of colours Lacquer coated surface Recyclable Approval / Standards Sarnafil S 327-15EL is designed and manufactured to meet most international recognised standards. Polymeric sheets for roof waterproofing according to EN 13956, certified by notified body 1213-CPD-3917 and provided with the CE-mark. Reaction to fire according to EN 13501-1. External fire performance tested according to ENV 1187 and classified according to EN 13501-5: B ROOF (t1). Official Quality Approvals and Agrement Certificates and approvals. Monitoring and assessment by approved laboratories. Quality Management system in accordance with EN ISO 9001/14001. Sarnafil S 327-15EL 1/6

Appearance / Colours Surface. matt Colours: Top surface: light grey (nearest RAL 7047) lead grey (Sika colour no. 9500) copper patina (Sika colour no. 6525) window grey (nearest RAL 7040) copper brown (nearest RAL 8004) azure blue (nearest RAL 5009) traffic white (nearest RAL 9016) pearl copper metallic (nearest RAL 8029) with hammer style embossing Bottom surface: dark grey Top surface of sheet in other colours available on request, subject to small minimum order quantities. Packaging Storage Conditions / Shelf-Life Sarnafil S 327-15EL standard rolls are wrapped individually in a blue PE-foil. Packing unit: up to 27 rolls per pallet Roll length: 20.00 m Roll width: 2.00 m Roll weight: 72.00 kg Rolls must be stored in a horizontal position on pallet and protected from direct sunlight, rain and snow. Product does not expire if correctly stored. Sarnafil S 327-15EL 2/6

Technical Data Product Declaration EN 13956 Visible defects Pass EN 1850-2 Length 20 m (- 0 % / + 5 %) EN 1848-2 Width 2 m (- 0.5 % / + 1 %) EN 1848-2 Straightness 30 mm EN 1848-2 Flatness 10 mm EN 1848-2 Effective thickness 1.5 mm (- 5 % / + 10 %) EN 1849-2 Mass per unit area 1.8 kg/m² (- 5 % / + 10 %) EN 1849-2 Water tightness Pass EN 1928 Effects of liquid EN 1847 chemicals, including water On request External fire performance: ENV 1187 Part 1-4 B ROOF (t1) 20, > 20 EN 13501-5 Reaction to fire Class E EN ISO 11925-2, classification to EN 13501-1 Hail resistance: EN 13583 rigid substrate flexible substrate 22 m/s 30 m/s Joint peel resistance 300 N/50 mm EN 12316-2 Joint shear resistance 800 N/50 mm EN 12317-2 Water vapour transmission properties = 15'000 EN 1931 Tensile strength EN 12311-2 longitudinal (md) 1) 1100 N/50 mm transversal (cmd) 2) 1100 N/50 mm Elongation, EN 12311-2 longitudinal (md) 1) 12 % transversal (cmd) 2) 12 % Resistance to impact, EN 12691 hard substrate 600 mm soft substrate 900 mm Resistance to static load, EN 12730 soft substrate 20 kg rigid substrate 20 kg Tear strength EN 12310-2 longitudinal (md) 1) 200 N transversal (cmd) 2) 200 N Dimension stability, EN 1107-2 longitudinal (md) 1) 0.3 % transversal (cmd) 2) 0.2 % Foldability at low temperature -25 C EN 495-5 UV exposure Pass (> 5000 h) EN 1297 1) md = machine direction 2) cmd = cross machine direction Sarnafil S 327-15EL 3/6

System Information System Structure Wide range of accessories is available e.g. prefabricated parts, roof drains, scuppers, walkway pads and decor profiles. The following materials are strongly recommended: Sarnafil G 410-15EL / S 327-15EL Sheet for detailing Sarnafil S 327-15EL for Coverstrips Sarnafil Metal Sheet Sarnabar S-Welding Cord Sarna Seam Cleaner Sarnacol 2170 (contact adhesive) Application Details Substrate Quality The substrate surface must be uniform, smooth and free of any sharp protrusions or burrs, etc. Sarnafil S 327-15EL must be separated from any incompatible substrates by an effective separation layer to prevent accelerated ageing. Prevent from direct contact with bitumen, tar, fat, oil, solvent containing material and direct contact to other plastic materials, e.g. expanded polystyrene (EPS) and extruded polystyrene (XPS) as this could adversely affect the product properties. The supporting layer must be compatible to the membrane, solvent resistant, clean, dry and free of grease and dust. Metal sheets must be degreased with before adhesive is applied. Application Conditions / Limits Temperature Compatibility The use of Sarnafil S 327-15EL membrane is limited to geographical locations with average monthly minimum temperatures of -50 C. Permanent ambient temperature during use is limited to +50 C. Not compatible with direct contact to other plastics, e.g. EPS and XPS. Not resistant to tar, bitumen, oil and solvent containing materials. Sarnafil S 327-15EL 4/6

Installation Instructions Installation Method / Tools Installation procedure: According to the valid installation instructions for Sarnafil S 327-EL types system for mechanically fastened roofs. Fixing Method, linear fasting (Sarnabar): Unroll the Sarnafil S 327-15EL membrane, overlap by 80 mm, weld immediately and to fix the substructure by means of Sarnabars. The type of fastening and the distance will be advised by Sika Ltd, Sika Sarnafil. The perimeter piece ends must be secured with the Sarnafil Sarnabar End Washer. For protection fasten a piece of Sarnafil under bar end and plate. Leave a 10 mm clearance between bar ends. Do not fasten in hole nearest bar end. Cover the bar ends with a piece of Sarnafil and weld. After installation the Sarnabars must immediately be made watertight with a Sarnafil cover strip. At upstands and at all penetrations, the Sarnafil S 327- -15EL membrane must be secured with a Sarnabar. The 4 mm diameter S-Welding Cord protects the Sarnafil S 327-15EL roof covering against tearing and peeling of by wind uplift. Fixing Method, spot fasting (Sarnafast): Sarnafil S 327-15EL must always be installed at right angles to the deck direction. Sarnafil S 327-15EL is fixed by means of the Sarnafast fasteners and barbed washers along the marked line, 35 mm from the edge of the membrane. Sarnafil S 327-15EL is overlapped by 120 mm. The spacing of the fasteners is in accordance with the project specific calculations made by Sika Ltd, Sika Sarnafil. Welding Method: Overlap seams are welded by electric hot air welding equipment, such as manual hot air welding machines and pressure rollers or automatic hot air welding machines with controlled hot air temperature. Recommended type of equipment: Leister Triac PID for manual welding Sarnamatic 661 plus for automatic welding Notes on Installation / Limits Welding parameters including temperature, machine speed, air flow, pressure and machine settings must be evaluated, adapted and checked on site according to the type of equipment and the climatic situation prior to welding. The effective width of welded overlaps by hot air should be minimum 20 mm. The seams must be mechanically tested with screw driver to ensure the integrity / completion of the weld. Any imperfections must be rectified by hot air welding. Installation works must be carried out only by Registered Sarnafil Contractors. Temperature limits for the installation of the membrane: Substrate temperature: -30 C min. / +60 C max. Ambient temperature: -20 C min. / +60 C max. Installation of some ancillary products, e.g. contact adhesives / cleaners is limited to temperatures above +5 C. Please observe information given by Product Data Sheets. Special measures may be compulsory for installation below +5 C ambient temperature due to safety requirements in accordance with national regulations. Sarnafil S 327-15EL 5/6

Roofing Value Base Local Restrictions Ecology, Health and Safety Information Protective Measures Transportation Class Disposal Legal note All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local Product Data Sheet for the exact description of the application fields. The product does not fall within the EU-regulation of hazardous goods. As a result, a material safety data sheet following EU-Guideline 91/155 EWG is not needed to bring the product to the market, transport or use it. The product does not damage the environment when used as specified. Fresh air ventilation must be ensured, when working (welding) in closed rooms. Regulatory safety requirements must be observed. The product is not classified as hazardous good for transport. The material is recyclable. Any disposal must be in accordance with regulatory requirements. All data in our product information are based on our current knowledge and experience. They do not release users from careful testing of the application and strict observation of the relevant processing regulations because of the wide range of possible influences during the application and use of our products. Legally valid assurances of specific characteristics or suitability for special purposes of application other than those provided in our documentation for the specific product cannot be inferred from our information. Any protective rights or existing laws and provisions must be followed by the recipient or processor of our products at their own responsibility. Moreover our general terms and conditions of sale and guarantee are valid. SIKA LIMITED Head Office Watchmead Welwyn Garden City Hertfordshire AL7 1BQ United Kingdom Phone: +44 1 707 394444 Fax: +44 1 707 329129 www.sika.co.uk Sarnafil S 327-15EL 6/6