Rosemount 333 HART Tri-Loop



Similar documents
Rosemount 333 HART Tri-Loop

Rosemount 1199 Submersible Seal

Techniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices

Replacing Displacers with Guided Wave Radar

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Reliable Pressure Measurement with Remote Diaphragm Seals in Cold Weather Applications

How To Connect An Hart Tri Loop To A Model 333 Hart To Analog Signal Converter

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Rosemount 1199 Submersible Seal

Rosemount 751 Field Signal Indicator

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Analog signal converters CC-E I/I Current / current isolators

Rosemount D Solids Scanners for Bulk Solids Inventory and Financial Reporting

Import the Gateway Certificate to the Browser

LEVEL AND VOLUME MEASUREMENTS OF BULK SOLIDS

Model 3051 Pressure Transmitter with HART Protocol

Rosemount 708 Wireless Acoustic Transmitter

EMERSON S ROSEMOUNT PROJECT MANAGEMENT OFFICE. Delivering project success for your instrumentation

Level Instrumentation for the Refining Industry

Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Rosemount 248 Wireless Temperature Transmitter

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Rosemount 2088 Absolute and Gage Pressure Transmitter

S-series Mass Connection Solutions

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Best Practices for Reducing Transmitter Life Cycle Costs

Smart Wireless Solutions. Intelligent Well Production Starts Here

3500/62 Process Variable Monitor

80 Series - Modular timers 16 A. Features

3DLevelScanner II TECHNICAL DATA SHEET

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Model: DC-A2IO Advanced HVAC Controller

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Micro Motion Model 2200S Transmitters

DeltaV SISnet Repeater

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Emerson Smart Wireless Gateway Solutions

Electronic Control Devices The European Product Catalogue 2007

2002 IS Catalog. Page

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Rosemount 248 Temperature Transmitter

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

1.1 Fill fluids. Rosemount DP Level Fill Fluid Specifications July Technical Note , Rev DB

80 Series - Modular timers 16 A. Features

Duct Humidity Transmitter

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Rosemount 3095 MultiVariable Transmitter with MODBUS Protocol ProductDiscontinued

38 Series - Relay interface modules A

MLC TM Maximum Productivity and Versatility for Control without Compromise!

J TB/TW Temperature limiter, temperature monitor

38 Series - Relay interface modules A

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Digital input modules

ROC800-Series Advanced Pulse Module

1701/22 FieldMonitor Management Interface Module

Waveguide Access Point WGA631. Product Guide

Dynamic Pressure Charge Amplifier

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Power Supplies 3. SDN-P DIN Rail Series

3500/93 System Display

Monitoring Water Quality For Today s Demanding World

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Mobrey Hydrastep and Hydratect

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Contents. Document information

Electronic Control Devices The European Product Catalogue 2007

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

MINI MCR-SL-R-UI(-SP)

Application Note TMA Series

Differential Charge Amplifier

Unidirectional Transmitter/ Receiver Units Introduction

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

S-series DC to DC Power Supply

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

T0118 T2118 T3118. Instruction Manual

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

TX OPEN RS232/485 module

CompactLogix Power Supplies Specifications

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Technical Data Sheet. 3DLevelScanner

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Features. Picture. Specifications

Regards from the Team at Rheology Solutions.

Transcription:

Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product for multivariable instruments Available as either High-alarm or Low-alarm device Contents Ordering Information................................................. page 3 Specifications...................................................... page 3 Dimensional Drawings................................................ page 5 www.rosemount.com

Rosemount 333 Product Data Sheet HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three analog signals Convert a multivariable digital HART signal into independent 4-20 ma analog process variables using the Rosemount 333 HART Tri-Loop. Apply in control or monitoring applications to obtain up to three additional analog outputs without additional process penetrations. Accessory product for multivariable instruments For use with the Rosemount 3051S MultiVariable, 3051S Advanced HART Diagnostics, and 3144P products. When used with the 3051S MultiVariable transmitter, the 333 HART Tri-Loop allows possible outputs of Differential, Absolute or Gage pressure, Process Temperature, Mass or Volumetric Flow, Energy Flow, Totalized Flow, and Sensor Module Temperature. When used with the 3051S Advanced HART Diagnostics, possible outputs include Pressure, Sensor Module Temperature, Scaled Variable, Deviation, and Mean. When used with the Rosemount 3144P, possible outputs include Sensor 1, Sensor 2, Differential and Transmitter Terminal Temperature. Easy to configure and install The 333 HART Tri-Loop is easy to configure and maintain using the 475 Field Communicator. AMS Device Manager provides easy PC-based user configuration. Installation is quick and easy with three DIN rail mount options and electrically isolated analog output channels for flexible grounding. Available as either High-alarm or Low-alarm device Tri-Loop alarm channels are factory configured. All channels alarm if the attached device indicates a sensor failure or transmitter malfunction. Figure 1. Example Tri-Loop Installation with Rosemount 3051S MultiVariable Transmitter HAZARDOUS AREA DIN Rail Mounted HART Tri-Loop Ch. 3 Ch. 2 Ch. 1 Burst Input to Tri-Loop Each Tri-Loop Channel receives power from Control Room Channel 1 must be powered for the Tri-Loop to operate Rosemount 3051S MultiVariable Transmitter RL 250 HART Burst Command 3/ Analog Output Intrinsically Safe Barrier Device receives power from Control Room for Primary Variable Loop Control Room NON HAZARDOUS AREA 2

Product Data Sheet Rosemount 333 Ordering Information Table 1. Rosemount 333 HART Tri-Loop The offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Model Product Description 333 HART Tri-Loop Alarm Option U High Alarm D Low Alarm Configuration Option C2 Custom Configuration (Configuration Data Sheet must be completed) Typical Model Number: 333 U Specifications FUNCTIONAL SPECIFICATIONS Service Accessory product for use with the 3051S MultiVariable Transmitter, 3051S Advanced HART Diagnostics Transmitter, 3144P Temperature Transmitter, or any other HART device with a burst mode output. Output One, two, or three 4 20 ma user-selectable output signals. Device 3051S MultiVariable 3051S 3144P Output Options DP, AP, GP, PT, Mass or Volumetric, Energy Flow, Totalized Flow, and Sensor Module Temperature. Pressure, Sensor Module Temperature, Scaled Variable, Deviation, and Mean. Sensor 1, Sensor 2, Differential Temperature, or Transmitter Terminal Temperature. Power Supply External power supply required for each channel. Each channel operates on terminal voltage of 11 42.4 Vdc. NOTE Channel 1 must be powered for Tri-Loop operation. Load Limitations Loop resistance is determined by the voltage level of the external power supply, as described below: Max. Loop Resistance = Power Supply Voltage-11 0.022 Load (Ohms) 142 1200 1000 800 600 400 200 Turn-on Time Analog signals will be within specifications five seconds after power is applied to Tri-Loop. Installation Locations Approved for FM ordinary locations, approved for CSA ordinary locations Temperature Limits Ambient 50 to 104 F (10 to 40 C) Operating Region 0 10 20 30 40 42.4 Power Supply Voltage, Vdc Storage 40 to 158 F ( 40 to 70 C) 3

Rosemount 333 Product Data Sheet Humidity Limits 0 95% non-condensing relative humidity. Failure Mode Alarm If Tri-Loop diagnostics detect a Tri-Loop failure or the transmitter indicates a transmitter malfunction, the analog signal for all channels will be driven either below 3.75 ma or above 21.75 ma to alert the user. The high or low alarm signal is determined by the Tri-Loop Model Number, see Alarm Configuration on page 4. PERFORMANCE SPECIFICATIONS (Performance specifications are for the HART Tri-Loop only.) Reference Accuracy ±0.045% of span Ambient Temperature Effect per 50 F (28 C) ±0.15% of span Stability ±0.1% of span for 12 months Analog Output Update Tri-Loop responds to every HART burst update (Typical transmitter burst update rate: 0.3 to 0.5 s.) Tri-Loop Response Time (after each burst update) Channel 1:120 ms; Channel 2:220 ms; Channel 3:320 ms Total Response Time Typical response time from sensor change to transmitter to Tri-Loop analog update: 0.7 to 1.0 seconds. Electromagnetic Compatibility (EMC) Meets all relevant requirements of EN 61326-1:2006 ESD tested to 4 kv contact and 4 kv air EM field immunity from 80 MHz to 1 GHz tested to 3 V/m Limits of performance criterion A defined as < ± 0.1% of span PHYSICAL SPECIFICATIONS Electrical Connections Screw clamps. Accepts 24 12 AWG solid or stranded wire. Dimensions 1.57 3.11 3.36 in. (40 79 85,5 mm) DIN Rail Mounting Options Asymmetrical 32 mm G rail, symmetrical 35 7.5 mm top hat rail, or symmetrical 35 15 mm top hat rail (see Tri-Loop Dimensions on page 5). Weight 0.27 lb (0,1 2 kg) Alarm Configuration Tri-Loops are configured with all channels to alarm in the same direction. Alarm direction is configured at the factory, and cannot be changed in the field. In addition, all channels alarm if the attached device indicates a sensor failure or transmitter malfunction. Tri-Loops are ordered according to the desired alarm direction. Configuration Unless otherwise specified with a C2 option, Tri-Loop is shipped as described in Table 2. Tri-Loop Label Each Tri-Loop is labeled with serial number, part number, and factory configuration. Custom Configuration If a Tri-Loop is ordered with a C2 option for custom configuration, the assigned variable, variable range, variable units, and channel status are assigned for all three channels. 333 HART Tri-Loop Configuration The 333 HART Tri-Loop can be fully configured using the 475 Field Communicator. AMS Device Manager software provides a PC-based user configuration. Table 2. Configuration Tri-Loop Channel Assigned Variable Variable Range Variable Units Channel Status Channel 1 Second 0 250 inh 2 O at 68 F Disabled Channel 2 Third 0 800 psi Disabled Channel 3 Fourth 40 to 400 Degree F Disabled 4

Product Data Sheet Rosemount 333 Figure 2. DIN Rail Mounting Options SYMMETRICAL 35 X 7.5 MM TOP HAT RAIL SYMMETRICAL 35 X 15 MM TOP HAT RAIL ASYMMETRICAL 32 MM G RAIL Dimensional Drawings Tri-Loop Dimensions 1.57 (40) 3.11 (79) 3.36 (86) NOTE Dimensions are in inches (millimeters) 5

Rosemount 333 Product Data Sheet Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. Tri-Loop and MultiVariable are trademarks of Rosemount Inc. HART is a registered trademark of the HART Communication Foundation. All other marks are the property of their respective owners. Emerson Process Management Emerson Process Management Rosemount Measurement 8200 Market Boulevard Chanhassen MN 55317 USA Tel (USA) 1 800 999 9307 Tel (International) +1 952 906 8888 Fax +1 952 949 7001 Emerson Process Management Blegistrasse 23 P.O. Box 1046 CH 6341 Baar Switzerland Tel +41 (0) 41 768 6111 Fax +41 (0) 41 768 6300 Emerson FZE P.O. Box 17033 Jebel Ali Free Zone Dubai UAE Tel +971 4 811 8100 Fax +971 4 886 5465 Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Singapore 128461 Tel +65 6777 8211 Fax +65 6777 0947 Service Support Hotline : +65 6770 8711 Email : Enquiries@AP.EmersonProcess.com 00813-0100-4754 Rev FA, 1/11