Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components



Similar documents
PRESSURE REDUCING CONTROL VALVE

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

Automatic Control Valves

BERMAD Waterworks. High Pressure, Surge Anticipating Control Valve. 800 Series. Model 835-M. Features and Benefits. Major Additional Features

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

BERMAD Waterworks. Surge Anticipating Control Valve. 700 Series. Model 735-M. Features and Benefits. Major Additional Features

V47 Series Temperature Actuated Modulating Water Valves

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Float and Thermostatic Traps Series H, C and X

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

APCO SLOW CLOSING AIR/VACUUM VALVES

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

TECHNICAL DATA. Dry 122a. November 12, 2013

American- Darling 5¼" B-84-B-5.

TYPE E Main Valve Sizes 3 /8 through 12

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Baumann Way Bronze or Stainless Steel Control Valve

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

RMF Engineering

RUBBER SLEEVE KNIFE GATE VALVE

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Model RV-1 Pressure Relief Valve 2 to 8 Inch (DN50 to DN200), 250 psi (17,2 bar) Pilot-Operated, Globe and Angle Body Styles General Description

Type 92S Pilot-Operated Steam Regulator

Distributed By: M&M Control Service, Inc

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

REGULATORS D& HD Series

Operation and Maintenance Manual Reduced Pressure Backflow Prevention Assemblies

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

WATER PRESSURE REDUCING VALVES

POWERS Controls No. 4 Pneumatic Damper Actuator

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

Installation, Maintenance, & Repair Series 4000B/LF4000B

Automatic Control Valves WATTS EU 100 Series

HOPPER SHAPE KNIFE GATE VALVE

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

Section 3510: Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011

1805 Series Relief Valves

Experience In Motion. Valtek Spring Cylinder Linear Actuators

Stainless Steel Single and Dual Circulation Kits

Baumann Flexsleev Sanitary Control Valve

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Fisher 377 Trip Valve

AIR LINE VALVES AND GAUGES

08.08 Vic-Check Valves

INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS PARTS LIST

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

PVH131/141 Variable Displacement Piston Pump - 11 Design

Cla-Val. Service Training Manual and Trouble Shooting Guide. Simple solutions plus learning with a purpose

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Diaphragm Control Valves FLUXOTROL Series I and Series 25 Installation and Maintenance Instructions

BOWIE PUMPS OPERATION - MAINTENANCE

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

MP8000 Series Pneumatic Valve Actuators

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

167D Series Switching Valves

Authentic ITT Service Parts

M A N U A L

AURORA AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES

BERMAD Fire Protection

1301 Series High-Pressure Regulators

SELECTION, APPLICATION AND MAINTENANCE

IOM SERIES 820-E/P Electro-Pneumatic Positioner

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

V46 Pressure-Actuated Water-Regulating Valve

Types 66R and 66RR Low-Pressure Relief Valves

REMOVAL AND INSTALLATION

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

Automatic Self-Cleaning Strainers

Wet System. Technical Manual for Operation, Maintenance, and Troubleshooting

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE STYLE Consult factory for sizes

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE STYLE Consult factory for sizes

Direct-Operated Pressure & Temperature Regulating Valves

Type 119 Control Valve

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Installation, Maintenance, & Repair Series 909, LF909, 909RPDA, LF909RPDA Reduced Pressure Zone Assemblies Reduced Pressure Detector Assemblies

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Self-contained valve functions as integral check valve, flow sensing element and bypass control valve.

FLANGED END BALL VALVE

MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder

PLUMBING VALVES HOUSTON ORLANDO GREENVILLE 800/ / / TOTAL MAINTENANCE SOLUTIONS

Transcription:

Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE 05/09 Reducing and Sustaining setpoints are separately adjustable 3 2 Standard Components (AOS) P/L 1 Main Valve (Single Chamber) 2 Pressure Reducing Control 3 Pressure Sustaining Control 4 Fixed Orifice 4 X X Y/FC FLOW CLOSES VALVE OPENS VALVE 1 X Options & Accessories X Isolation Cocks (2) FC Flo-Clean Strainer (1) Y Y-Strainer (Replaces Flo-Clean) (2) ACS Adjustable Closing Speed (3) (Replaces Fixed Orifice) AOS Adjustable Opening Speed (1) P Position Indicator (3) L Limit Switch (3) (1) Standard 3 & Smaller (2) Standard 4 & Larger (3) Optional All Sizes Operations The Combination Pressure Reducing and Pressure Sustaining Control Valve is designed to automatically reduce a fluctuating higher upstream pressure to a constant lower downstream pressure regardless of varying flow rates, and will throttle to sustain a minimum upstream pressure. It is controlled by a normally open, pressure reducing pilot designed to: 1) Open (allowing fluid out of the main valve cover chamber) when downstream pressure is below the adjustable setpoint, and 2) Close (allowing fluid to fill the main valve cover chamber) when downstream pressure is above the adjustable setpoint. A decrease in downstream pressure causes the valve to modulate toward an open position, raising downstream pressure. An increase in downstream pressure causes the valve to modulate toward a closed position, lowering downstream pressure. The normally closed sustaining pilot remains open when upstream pressure is above the adjustable setpoint, and modulates toward a closed position if upstream pressure falls below the setpoint. As the sustaining pilot closes, fluid is directed into the main valve cover chamber, allowing the valve to modulate toward a closed position, raising upstream pressure. Normal pressure reducing operation resumes when upstream pressure is above the sustaining pilot setpoint, and downstream pressure is below the reducing pilot setpoint.

Materials Globe Angle Body & Cover: Ductile Iron ASTM A536 Coating: NSF Listed Fusion Bonded Epoxy Lined and Coated D K L K Trim: 316 Stainless Steel K Elastomers: Stem, Nut & Spring: Buna-N (standard) EPDM Viton Stainless Steel A B C E F G H I J Operating Pressure Operating Temperature Pilot System Tubing & Fittings Threaded = 400 psi Buna-N: 160 F Maximum Reducing Control Copper / Brass (Standard) 150 Flanged = 250 psi EPDM: 300 F Maximum 30-300 psi (Standard) Stainless Steel (Optional) 300 Flanged = 400 psi Viton: 250 F Maximum 0-30 psi (Optional) Sustaining Control 20-200 psi (Standard) 0-30 psi (Optional) Dimensions VALVE SIZE A B C D E F G H I J K L GLOBE THRD. GLOBE 150# GLOBE 300# COVER TO CENTER THRD. 150# 300# THRD. 150# 300# PORT SIZE PORT SIZE SHIPPING WEIGHTS* 1-1/4 7-1/4 - - 5-1/2 3-1/4 - - 1-7/8 - - 3/8 1/4 20 1-1/2 7-1/4 8-1/2 9 5-1/2 3-1/4 4 4-1/4 1-7/8 4 4-1/4 3/8 1/4 25 2 9-3/8 9-3/8 10 6-1/2 4-3/4 4-3/4 5 3-1/4 3-1/4 3-1/2 3/8 1/2 40 2-1/2 11 11 11-5/8 7-1/2 5-1/2 5-1/2 5-7/8 4 4 4-5/16 1/2 1/2 65 3 12-1/2 12 13-1/4 8-1/4 6-1/4 6 6-3/8 4-1/2 4 4-3/8 1/2 1/2 95 4-15 15-5/8 10-5/8-7-1/2 7-7/8-5 5-5/16 3/4 3/4 190 6-20 21 13-3/8-10 10-1/2-6 6-1/2 3/4 3/4 320 8-25-3/8 26-3/8 16-12-3/4 13-1/4-8 8-1/2 1 1 650 10-29-3/4 31-1/8 17-1/8-14-7/8 15-9/16-8-5/8 9-5/16 1 1 940 For larger sizes consult factory Valve Cover Chamber Capacity Valve Size (in) 1-1/4 1-1/2 2 2-1/2 3 4 6 8 10 fl.oz. 4 4 4 10 10 22 70 - - U.S. Gal - - - - - - - 1-1/4 2-1/2 Valve Travel Valve Size (in) 1-1/4 1-1/2 2 2-1/2 3 4 6 8 10 Travel (in) 3/8 3/8 1/2 5/8 3/4 1 1-1/2 2 2-1/2

Sizing Size (in) 1-1/4 1-1/2 2 2-1/2 3 4 6 8 10 Maximum Continuous (GPM) 95 130 210 300 485 800 1850 3100 5000 Maximum Intermittent (GPM) 119 161 265 390 590 1000 2300 4000 6250 Minimum Continuous (GPM) 1 1 1 20 30 50 115 200 300 Maximum continuous flow based on velocity of 20 ft. per second. Maximum intermittent flow based on velocity of 25 ft. per second. Minimum continuous flow based on velocity of 1 ft. per second. NOTE: The above chart is a suggested guide. Inlet pressure, outlet pressure, minumum, normal and maximum flow rates should be considered for specific valve sizing. Contact Watts ACV for details. Cavitation Chart CAVITATION CHART After selecting the valve size, locate inlet and outlet pressures on this chart. If the intersection point falls in the shaded area, cavitation can occur. Operation of valves continually in the cavitation zone should be avoided. Consult Watts ACV for alternatives. INLET PRESSURE - PSI 300 CAVITATION ZONE 280 260 240 220 200 180 160 140 120 100 80 60 40 20 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 OUTLET PRESSURE - PSI

Cross-Sectional Detail Main Valve 1 2 3 4 5 6 7 10 11 12 13 14 15 16 8 9 17 ITEM DESCRIPTION MATERIAL 1 Cover ASTM A536 65-45-12 Epoxy Coated Ductile Iron 2 Cover Bearing ASTM A276 304 Stainless Steel 3 Shaft / Stem ASTM A276 304 Stainless Steel 4 Stud ASTM A570 Gr.33 Zinc Plated Steel 5 Cover Nut ASTM A570 Gr.33 Zinc Plated Steel 6 Diaphragm* Buna-N (Nitrile) 7 Body ASTM A536 65-45-12 Epoxy Coated Ductile Iron 8 Seat Disc* Buna-N (Nitrile) 9 Seat Ring ASTM A743 CF8M (316) Stainless Steel 10 Spring ASTM A276 302 Stainless Steel 11 Stem Nut ASTM A276 304 Stainless Steel 12 Spring Washer ASTM A276 304 Stainless Steel 13 Diaphragm Washer ASTM A536 65-45-12 Epoxy Coated Ductile Iron 14 Disc Retainer ASTM A536 65-45-12 Epoxy Coated Ductile Iron 15 Spacer Washer* Fiber* 16 Disc Guide ASTM A743 CF8M (316) Stainless Steel 17 Seat Gasket* Buna-N (Nitrile) * Contained in Main Valve Repair Kit

Controls and Accessories Model CP-15 Pressure Reducing Pilot 1 10 11 2 12 13 3 4 5 14 15 6 7 16 8 Front View 9 Side View ITEM NUMBER DESCRIPTION 1 Adjusting Screw 2 Jam Nut 3 Spring Housing 4 Spring 5 Cap Screw 6 Body 7 Seat 8 O-Ring* 9 Bottom Cap 10 Spring Guide ITEM NUMBER DESCRIPTION 11 Nut 12 Belleville Washer 13 Diaphragm Washer 14 Diaphragm * 15 Yoke 16 Disc and Retainer Assembly* * Included in Repair Kit

Controls and Accessories Model CP-16 Pressure Sustaining Control 1 2 3 4 5 11 12 14 16 17 15 13 18 6 7 8 9 19 21 20 10 ITEM NUMBER DESCRIPTION 1 Adjusting Screw 2 Jam Nut 3 Spring Housing 4 Spring 5 Cap Screw 6 Shaft O-Ring* 7 Power Chamber 8 O-Ring * 9 Body 10 Seat 11 Spring Guide ITEM NUMBER DESCRIPTION 12 Upper Stem Nut 13 Belleville Washer 14 Upper Diaphragm Washer 15 Diaphragm * 16 Lower Diaphragm Washer 17 O-Ring * 18 Stem 19 O-Ring * 20 Disc and Retainer Assembly * 21 Lower Stem Nut * Included in Repair Kit

Installations Prior to installation, flush line to remove debris. Install valve horizontally in line (cover facing up), so flow arrow matches flow through the line. Avoid installing valves 6 and larger vertically. Consult factory prior to ordering if installation is other than described. Install inlet and outlet isolation valves. NOTE: When using butterfly valves, insure disc does not contact control valve. Damage or improper valve seating may occur. Provide adequate clearance for valve servicing and maintenance. Install pressure gauges to monitor valve inlet and outlet pressure. If installation is subjected to very low flow or potentially static conditions, it is recommended a pressure relief valve (1/2 minimum) be installed downstream of the Pressure Reducing Valve for additional system protection. Start-Up Proper Automatic Control Valve start up requires bringing the valve into service in a controlled manner. All adjustments to control pilots and speed controls should be made slowly, allowing the valve to respond and the system to stabilize. NOTE: Control Valves should be set up in a dynamic (flowing) condition for proper start up. Provisions for flow must be made to insure proper settings. For proper valve set-up upstream pressure must be manually lowered to desired sustaining setpoint. 1. Close upstream and downstream valves to isolate the valve from line pressure. Release spring tension on Pressure Reducing and Sustaining Controls by turning adjustment screws out (counterclockwise), decreasing setpoints. Open all Isolation Ball Valves, if so equipped. If valve is fitted with adjustable speed controls, turn needle(s) in (clockwise) until seated, and return out (counterclockwise) 1 1/2 to 2 1/2 turns. These are approximate settings, and should be fine tuned to suit system requirements after pressure adjustments have been made. 2. Slowly open upstream isolation valve to allow controlled filling of the valve. Vent entrapped air by carefully loosening control tubing or pipe plug at the highest point possible. If valve is equipped with a Position Indicator, open Air Bleed Petcock to vent air. Water will be milky in appearance and will begin to clear as air is vented. Carefully loosen enough cover screws on control pilot(s) to vent entrapped air. Re tighten when water vents clearly. 3. Setting Reducing Control: Slowly open downstream isolation valve. Gradually turn adjustment screw on the Pressure Reducing Control in (clockwise) to raise downstream pressure. Allow valve and system to stabilize. Observe inlet and outlet pressure gauges. Continue to adjust as needed, pausing approximately every 1 1/2 turns, allowing valve and system to stabilize. Turning adjustment screw clockwise raises outlet pressure. Turning adjustment screw counterclockwise lowers outlet pressure. When desired downstream pressure is reached, tighten locknut on adjustment screw. 4. Setting Sustaining Control: Partially close upstream isolation valve, lowering valve inlet pressure, until upstream pressure gauge is at desired sustained setpoint. While observing upstream pressure gauge (or Position Indicator), slowly turn Pressure Sustaining Control adjustment screw clockwise until upstream pressure begins to rise. The Sustaining Pilot is set at the point the valve begins to close, raising upstream pressure. Tighten locknut on adjustment screw. Fully open upstream isolation valve. 5. Fine tune Speed Controls to suit system requirements. Adjust Closing Speed Control (if equipped) clockwise for slower closure, and counterclockwise for faster closure. Adjust Opening Speed Control (if equipped) clockwise for slower opening, and counterclockwise for faster opening.

Specifications The Pressure Reducing and Sustaining Control Valve shall be a pilot operated diaphragm valve designed to automatically reduce a fluctuating higher upstream pressure to a constant lower downstream pressure regardless of varying flow rates, and sustain a minimum upstream pressure. The main valve shall be a hydraulically operated, single diaphragm actuated, globe or angle pattern valve. Y-pattern valves shall not be permitted. The valve shall contain a disc and diaphragm assembly that forms a sealed chamber below the valve cover, separating operating pressure from line pressure. The diaphragm shall be constructed of nylon reinforced Buna-N, and shall not seal directly against the valve seat and shall be fully supported by the valve body and cover. Rolling diaphragm construction will not be allowed and there shall be no pistons operating the main valve or any pilot controls. The main valve body and cover shall be Ductile Iron ASTM A536, and all internal cast components shall be Ductile Iron or CF8M (316) Stainless Steel. All Ductile Iron components, including the body and cover, shall be lined and coated with an NSF 61 Certified Epoxy Coating applied by the electrostatic heat fusion process. All main valve trim and throttling components (cover bearing, valve seat and disc guide) shall be Stainless Steel. The valve body and cover must be machined with a 360-degree locating lip to assure proper alignment. The disc and diaphragm assembly shall contain a Buna-N synthetic rubber disc with a rectangular crosssection that is securely retained on 3-1/2 sides by a disc retainer and disc guide. Diaphragm assemblies utilizing bolts or cap screws for component retention will not be permitted. The exposed portion of the seat disc shall contact the valve seat and seal drip-tight. The disc and diaphragm assembly must be guided by two separate bearings, one installed in the valve cover and one concentrically located within the valve seat, to avoid deflection and assure positive disc-to-seat contact. Center guided valves will not be permitted. All necessary repairs shall be made from the top of the valve while the body remains in line. Pilot control systems for valves 3 and smaller shall contain a Flow Clean Strainer, Fixed Orifice Closing Speed, Adjustable Opening Speed Control, Pressure Sustaining Pilot and Pressure Reducing Pilot. Pilot control systems for valves 4 and larger shall contain an external Y-Strainer, Fixed Orifice Closing Speed, Pressure Sustaining Pilot, Pressure Reducing Pilot and Isolation Ball Valves on all body connections. All pilot control systems shall utilize copper tubing and brass fittings regardless of valve size. The adjustment range of the pressure sustaining pilot shall be 20-200 psi and the pressure reducing pilot shall be 30-300 psi. The valve shall be Watts ACV Model M115-2 or M6115-2 (Globe) or M1115-2 or M61115-2 (Angle) pattern Pressure Reducing and Sustaining Control Valve. Other Watts ACV Pressure Reducing Control Valves M115 / M6115 Pressure Reducing Valve M115-3 / M6115-3 Pressure Reducing Valve with Hydraulic Check Feature M115-4 / M6115-4 Pressure Reducing Valve with Solenoid (On-Off) Feature M115-7 / M6115-7 Pressure Reducing Valve with Downstream Surge Control Feature M115-11 / M6115-11 Pressure Reducing and Sustaining Valve with Hydraulic Check Feature M115-43 / M1115-43 Pressure Reducing and Sustaining Valve with Surge Control Feature M115-58 / M6115-58 Pressure Reducing Valve with Return Flow Feature M115-74 / M6115-74 Pressure Reducing Valve with Low Flow By-Pass