SoundLAB Software Download Software from the Bogen website: www.bogen.com/software



Similar documents
Model SL355 Noise Dosimeter/Datalogger

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

How to Download Images Using Olympus Auto-Connect USB Cameras and Olympus Master

Guide to Installing BBL Crystal MIND on Windows 7

CANON FAX L360 SOFTWARE MANUAL

Installing USB Drivers With Microsoft Windows XP

SA-9600 Surface Area Software Manual

Client Program Installation Guide

e-dpp May 2013 Quick Installation Guide Microsoft Windows 2003 Server, XP, Vista, 7 Access Database

ScanWin Installation and Windows 7-64 bit operating system

Screen Capture. User s Guide. For ClassPad Series

Operating Instructions

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE

ENPS-MF1. 1 USB Port. Multifunctional Print Server. Quick Installation Guide V1.0

3. USB DRIVER Installation of USB driver Driver for Infinity SD Data Logger. INFINITY Series Acquisition Tools Manual

Page 1 S5.5 Monitoring Software Manual Rev 1.2 for Software Ver 1.0

Centurion PLUS CPC4 Download Guide

This CD-ROM includes the following online guides;

3M Occupational Health and Environmental Safety 3M E-A-Rfit Validation System. Version 4.2 Software Installation Guide (Upgrade) 1 P age

IGSS. Interactive Graphical SCADA System. Quick Start Guide

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide

WindO/I-NV2 Utility Pass-Through Tool

Colorfly Tablet Upgrade Guide

DUKANE Intelligent Assembly Solutions

1. SAFETY INFORMATION

Use only a shielded parallel interface cable that is IEEE 1284-compliant and/or a USB cable that is no longer than 6 feet long (1.8 meters).

Installing a Westell USB Network Adapter

Installing the Gerber P2C Plotter USB Driver

MOBILE INTERNET HUAWEI E220 3G USB MODEM

User Manual. Thermo Scientific Orion

ShopStream Connect Software Download and Installation Instructions

EPSON Stylus COLOR 740. USB Software Installation Guide (Windows 98/iMac ) USB Setup Guide (imac)

Batch Eligibility Long Term Care claims

USB DRIVER INSTALLATION GUIDE

PP8X Printer Driver Installation Instruction

ScanShell.Net Install Guide

Lab: Data Backup and Recovery in Windows XP

Virtual Office Remote Installation Guide

Driver Upgrade Instructions

OS Upgrade Manual. Close any applications before proceeding with the update. Please connect your USB cable directly to. USB hub.) Do not disconnect

SMS Remote Software User Manual. Pro Series & Contender Series DVRs

EPSON USB/Parallel Adapter User s Guide

How do I monitor the ink levels on my EPSON Stylus printer using Windows 2000 or XP?

Windows XP.. ELITE Firmware Update procedures.. v1.41

If you are not using a network environment (i.e. USB connection only) If you are using the printer in a network environment

Analyzer 2.0. Installation Guide. Contents

Navigator Software. Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.

Thuraya XT-DUAL. Software Upgrade Manual

Topaz Installation Sheet

User s Manual. 1. Introduction 2. Product Features 3. System Requirements. 4. Installing IrDA Wireless Connection:

Rogue RE-CONN Utility

Checking the Package Contents. Installing the Printer Software. Connecting. Unpacking the. the Printer. Printer. Attaching

PXW-FS5/ PXW-FS5K System software update

How to Update PXW-X70 System software. Windows. Mac

SMS (Server Management Software) Digital Video Recorder. User s Manual

LCD MONITOR TOUCH PANEL DRIVER 2 OPERATION MANUAL. for Mac. Version 1.0 PN-L703A/PN-70TA3/PN-L703B/PN-70TB3/PN-L603A/PN-60TA3/PN-L603B/PN-60TB3

Software Repair Assistant Manual for DuraXV

Phocos CXCOM for CX and CXN Instruction Manual

Handheld LPC Data Retrieval Software for Windows. Operation Manual

File Management Utility. T u t o r i a l

CMP-102U. Quick Installation Guide

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

CNR-BTU5 Bluetooth Dongle

Korosi Monitoring System (KMS) Software Manual

Crystal Print Control Installation Instructions for PCs running Microsoft Windows XP and using the Internet Explorer browser

Export the address book from the Blackberry handheld to MS Outlook 2003, using the synchronize utility in Blackberry Desktop Manager.

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts

BIODEX. ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL

Phone: Fax: Web: info@ctiautomation.net

Caplio Utility for Windows

Free GMATPrep Test-Preparation Software Download and Installation Instructions

Lab - Data Backup and Recovery in Windows XP

Model 288B Charge Plate Graphing Software Operators Guide

Specifications. What s Inside The box

Viewing and Troubleshooting Perfmon Logs

Midland BT Updater BTUpdater Program Program file (x86) ), Midland

Trace600 OTDR Test Management Software User s guide

SOFTWARE INSTALLATION INSTRUCTIONS

F-Series Desktop User Manual F20. English - Europe/New Zealand

Driver Installation (USB 2.0) and Software configuration manuals for Sopro Imaging, EagleSoft, and Dentrix Image 4.5

TR-3 Channel Editor. Software Manual

Release Notes - Installing the Wireless Receiver on a PC.

Table of Contents Appendix 4-9

ANDROID RECOVERY STICK QUICK START GUIDE

This Upgrade Is Only Valid For The US Cellular SCH-I500 (Mesmerize). It Is Incompatible With All Other Models. Requirements

PCLinq2 Hi-Speed USB Bridge-Network Cable. Quick Network Setup Guide

Motorola Phone Tools. Quick Start

Using the Microsoft Bluetooth Stack

EOS REBEL XS / 1000D Firmware Update Procedures Precaution

USB FLASH DRIVE. User s Manual 1. INTRODUCTION FEATURES SPECIFICATIONS PACKAGE CONTENTS SYSTEM REQUIREMENTS...

Network Printing In Windows 95/98/ME

Select Correct USB Driver

Package Checklist. Overview. Features. USB Data Link Cable User s Manual. USB Data Link Cable User s Manual 1

Datalogger Graph Software Help

PLUS TV ANALOG USB STICK Installation Manual

Installing a printer in Windows 95.

GX-2009 Data Logger Management Program Operator s Manual

1. Open the battery compartment as shown in the image.

DIGICLIENT 8.0 Remote Agent Software

Transcription:

SPLM DIGITAL SOUND PRESSURE LEVEL METER SoundLAB Software INSTALLATION & INSTRUCTION MANUAL Download Software from the Bogen website: www.bogen.com/software Specifications are subject to change without notice. 2013 Bogen Communications, Inc. 54-2222-01A 1308

TABLE OF CONTENTS Installing and Using SoundLAB Software Installing SoundLAB Software...1-4 Software Instructions...5 Software Control Panel, File Menu, Option Bar Software Command Descriptions...5 Software Tool Bar...6 Tool Bar Functions PC Connection...6 System Setup...7 SPL Unit Setting...7 PC Software Setting...8 Real-Time Measurement...8 Measurement Bar Instructions...9 Import Data...9 PC Requirements Minimum requirements for connection with a PC: CPU: Pentium 600 MHz or higher One USB interface port Resolution of 800 x 600 (True Color) 8 MB available memory 50 MB available disk memory Operating system: Microsoft Windows XP/ Windows7

Installing SoundLAB Software You can download the SoundLAB software from the Bogen website at: www.bogen.com/software. Install the driver file and double-click the Setup.exe program icon to enter the program installation contact interface. Click NEXT to continue. Click BROWSE to change the installation folder. Click NEXT to continue. 1

Installing SoundLAB Software (contʼd) When this interface appears on screen, click NEXT to enter next step. Select Create A Desktop Icon if you want a desktop icon. Then click NEXT to enter the next step. 2

Installing SoundLAB Software (contʼd) Click INSTALL to begin the installation. When the interface displays, make sure to select Setupbde (database access engine). If it is the first time installing the software on the PC, click FINISH to install the database access engine. If this is not the first installation of the software on the PC, DO NOT select Setupbde. To begin using SoundLab, select Run SoundLab. Click FINISH to complete the installation. 3

Installing SoundLAB Software (contʼd) If this is the first time installing the software on the PC, you must install the database. When you see the screen shown below, click INSTALL to start the installation process. When you see the screen shown in the Figure below, click FINISH to complete the installation process. 4

Software Instructions Software Control Panel 1. Menu Bar 2. Tool Bar 3. Status Bar File Menu Option Menu You can check the connection status of the SPLM to the PC by looking at the on-screen Status Bar loacted at the bottom of the screen. Connect OK indicates the connection is active Disconnect indicates the SPLM failed to connect Software Command Descriptions COMMAND Real-Time Measure Open Save Import Data Export Data Printer Setup Print Data Sheet System Setup Language FUNCTION Real-Time Data Measurement: The Measured Data will be displayed on your computer screen Open Measurement Data File in SoundLab format Save Real-time Measurement Data Download the Measurement Data Export the Measurement Data to Excel Printer Setting Print Data Sheet System Setting Language selection of Software Contact Interface 5

Software Tool Bar Tool Bar Functions PC Connection 1. Insert one end of the USB cable into the USB jack on the side of the SPLM. 2. Plug the other end of the USB cable into the USB interface port on the PC. NOTE: Once the connection is made, a USB icon appears on the LCD of the SPLM indicating a successful connection. If the icon does not appear, the connection is not complete. When connected to the PC, the PC supplies power to the SPLM (so the AA batteries are not necessary and will not be used when the unit is connected to the PC). When the connection to the PC is ended, the SPLM will turn off automatically unless batteries are in the SPLM. 6

System Setup Click OPTION > SYSTEM SETUP or click to enter the SYSTEM OPTION. The default setup is SPL Unit Setting. Enter the company name if needed, then click OK or APPLY to confirm the setting. SPL Unit Setting Click SPL Unit Setting to setup the following items: measurement range, max. work mode, sample speed, and weight. Then click OK or Apply to confirm. 7

PC Software Setting Click OPTION > SYSTEM SETUP Click PC Software Setting to setup the Low/High db Alarm and the Alarm sound ON/OFF. Then click OK or Apply to confirm. Real-Time Measurement Click Real-Time Measure in File Menu Bar in the Tool column to enter the screen as shown below. 8

Measurement Bar Instructions BUTTON FUNCTION Start Real-Time Measurement Stop Real-Time Measurement Clear all the Measurement Data Click to Store Real-Time Measurement Data, Input file name in Popup Window, Click to Save the Document Print Graph Zoom In Zoom Out Reset Zoom, Resume to Defaulted Value Move Graph to Left or Right Import Data Click the Import Data in File Menu Bar or Import Data Button on Tool Column to display the following screen: Click Import to import the data stored in the SPLM to display as a graph. 9

50 Spring Street, Ramsey, NJ 07446, U.S.A. Tel. 201-934-8500 Fax: 201-934-9832 www.bogen.com 10