QFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living



Similar documents
QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

RRV934. Multi-controller. Synco living

Input module, input/output module

Air damper actuators

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Room Temperature Sensors

IN-OUT Thermometer with Cable Free Sensor and Clock

Flush-mount room temperature sensor AQR2531ANW.

VAV compact controller KNX / PL-Link

OZW30. Central Unit SYNERGYR

Digital input modules

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

TX OPEN RS232/485 module

Drayton Digistat +2RF/+3RF

HCR3.2/.. Chipcard reader HOTEL SOLUTION

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

HVAC central apartment unit with consumption data acquisition

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Wireless Indoor/ Outdoor Thermometer

REMOTE TERMOMETER TE 219 LED USER MANUAL

Transmitter Actuator 230V wave UP 560. Operation

T0118 T2118 T3118. Instruction Manual

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

GREISINGER electronic GmbH

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Instruction Manual. T3111 T3111L T3111P T3111Ex

VAV compact controller KNX / PL-Link

Infrarot-Bewegungsmelder IP44

Product and Application Description

Duct Humidity Transmitter

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

evohome Wireless Radiator Zoning Kit Installation & User Guide

Stove Guard Kit User Manual

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Rousseau 10. User Guide

Microwave Meter. Instruction Manual

DC Electronic Loads 8500 series

Getting started with

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

PCS0100en Persy Control Services B.V. Netherlands

KNX Gateway RGK E-01

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

WIRELESS MAGNETIC CONTACT

WEATHER STATION Instruction Manual Cat. No IT

OZS Web server. For LPB/BSB plants

DLO1191 Linear smoke detector

OZW V2.0. Web server. Synco TM, Synco TM living

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Mini InfraRed Thermometer with Laser Pointer

WIRELESS WATER LEAK DETECTOR

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

1. Overview. WPT Wireless Range Tester Kit User Manual Doc No Rev Components Prerequisites for Site Survey

RS 110 II. Quick Guide Consignes de sécurité Indicaciones de seguridad Guia de Segurança Sicherheitshinweise Guida per la sicurezza Veiligheidsgids

HERZ-Thermal Actuators

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Commander 2000 Control Panel

FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL

62 Max/62 Max + Infrared Thermometer

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Distress alert system. User Manual DAS1100

Telis 4 Soliris RTS Operating and installation guide Ref A

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Temperature & Humidity SMS Alert Controller

ST815 Illumination Sensor with LCD

User's Guide. Pinless Moisture Meter. Model MO257

Atomic Projection Alarm with Indoor and Outdoor Temperature

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

BEL-AIR WIRELESS THERMO-HYGROMETER Instructions manual Cat. No IT

FIRE DETECTION AND ALARM SYSTEMS

WIRELESS STATUS MONITOR

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

TS93 EMR T/PT/TDE. Surface applied door closer

USB/RS485 converter cable, complete

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

Wireless Data Logger Monitoring Systems

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

AXIS 291 1U Video Server Rack Installation Guide

Tele Radio Panther SAFETY instructions

HMI display Installation Guide

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.

Personal Assistance System Owner's Guide

StructureScan HD Module. Installation Guide ENGLISH

Smart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

OZW672...V5.2. Web-Server. For LPB/BSB plants

Digital inductive conductivity transmitter

4-Channel Thermometer / Datalogger

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

User Guide. Temperature and Humidity Datalogger. Model 42280

IntesisBox KNX LG Air Conditioning

WS-9005TWC 915MHz WIRELESS RAIN GAUGE INSTRUCTION MANUAL

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Transcription:

2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use Integrates into Siemens system Synco living Records water puddles in wet rooms, e.g. kitchens, bathrooms, laundry rooms, etc. Allows the following actions depending on how the central apartment unit is configured: Automatically close the shutoff valve for the main line Activate interior siren Sends an alarm via web on a PC or cell phone Deployed especially for: The renovation market (old buildings, museums, churches, historical buildings, etc.) Difficult wall mounting (sandstone, glass, etc.) New buildings CE1N2732en 2016-03-01 Building Technologies

Equipment combinations The QFP910 can be used together with the Siemens System Synco living. Detailed information on the device combinations is available in the data sheet for the central apartment unit. Ordering When ordering, please specify the quantity, product name, and type code. Delivery Order numbers The QFP910 consists of a water sensor and a radio transmitter. Each QFP910 is delivered with alkaline batteries, mounting materials and mounting instructions. Type Stock number Name QFP910 S55371-C100 Water detector with installation instructions Product documentation Operating and commissioning instructions for the QFP910 are included in the product documentation for the central apartment unit. Functions Main function Binding Status request RF binding test Error messages / Maintenance messages During normal operation, the QFP910 sends periodically, or for change its status (dry / water leak), to the central apartment unit. It interprets a "water leak" if the water sensor resistance drops below the lower limit value and the corresponding message is sent to the central apartment unit. The status for the QFP910 returns to "dry" if the resistance returns above the upper limit value and a corresponding message is once again sent to the central apartment unit. The state "water leak" is sent at one-minute intervals. The state "dry" is sent at 15-minute intervals. Binding logs the QFP910 on to the central apartment unit and thus integrates it into the radio system. The function button triggers the binding process. The function LED signals the process. The function button can query the battery level. The function LED signals the battery level. It is also sent in each telegram to the central apartment unit. The function button can trigger a binding test. This checks the radio link to the central apartment unit. The function LED signals the RF binding test. The maintenance message (batteries low) is forwarded to the central apartment unit and displayed there. The water sensor cannot be checked for short circuits or interrupts. As a consequence, there are no error messages for a short circuit or sensor interrupt. 2 / 8

The QFP910 generates the following messages: Error messages None Maintenance message Batteries low (battery life 3 months) Operating and display elements Function LED Function button 2701Z01 Overview of display and operating element functions on the QFP910: Function LED Battery level Binding process Function button Battery query Binding RF binding test Additional information on the function and operation of the QFP910 is available in the product documentation for the central apartment unit. Notes on engineering and operation Mounting location for water sensor Mount the water sensor in the building where there is water. The water sensor should be installed as close as possible to any potential water leak, e.g. in the laundry room, close to the washer or in the kitchen below the sink connections or input/output on the dish washer. The water sensor should be mounted on the wall at the lowest point so that the two contacts nearly touch the floor. The floor under the water sensor should be horizontal and even. 2732Z03 Observe permissible ambient conditions. The water sensor should not be located in water puddles for longer periods as this reduces battery life for the radio components. 3 / 8

RF Transmitter mounting location Mount the RF transmitter in the building. Mount it close to the water sensor at a maximum of 1.8 meters above it (water sensor cable length = 2 meters). Do not expose to drips and permissible ambient conditions must be maintained. Notes on engineering and mounting RF devices for the Siemens system Synco living are available in the communications data sheet CE1N2708en. Mount the RF transmitter's wall base on a flat wall. Maintain a minimum distance of 60 mm from the bottom to open the battery compartment. 60 2701Z03 Mount Note Mount the RF transmitter using a base on the wall. The RF transmitter can be mounted in most off-the-shelf recessed conduit boxes or directly on the wall. First mount the water sensor and then the RF transmitter. Then connect the water sensor to the RF transmitter. Only then insert the batteries in the RF transmitter. Commissioning Maintenance / Change battery Disposal Prior to commissioning, check whether the water sensor is professionally installed at the recommended location and in the proper position on the wall. Further, check whether the connecting cable is professionally connected to the corresponding terminals on the RF transmitter and whether functioning batteries are properly inserted in the RF transmitter. The QFP910 is maintenance free. The system reports when a change of batteries is required. The batteries are located under the cover for the battery compartment. No tools are required and batteries can be changed in a mounted device (reverse battery protection). You may have to clean the contact surfaces on the water sensor with a moist towel after the water detector reacts and the water puddle is dried out. It may trigger a "water leak" message. The message must then be acknowledged on the central apartment unit. The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Dispose of empty batteries in designated collection points. 4 / 8

The QFP910 is considered electronics device for disposal in terms of European Directive 2002/96/EG (WEEE) and may not be disposed of as domestic garbage. Comply with all relevant national and statutory regulations. Dispose of the device via the proper channels. Observe all local and applicable laws. Dispose of used batteries at the collection locations provided. Warranty Technical data relating to applications are guaranteed solely together with the Siemens Synco living system. Device combinations are available in the data sheet for the central apartment unit. The user ensures the functionality of operation for the QFP910 when using thirdparty devices. Siemens does not provide service or warranty services in this case. Technical data QFP910 Water sensor Water sensor Cable length Detector response time 2 m 2 seconds Technical data QFP910 RF transmitter Power supply Battery type Battery life (capacity 2.5 Ah) 2 x alkaline batteries LR6 (AA); 1.5 V 3 years (in "dry" state) RF Radio Frequency RF Range RF protocol 868 MHz, unidirectional Typically meters inside building KNX RF compatible Electrical connection Screw terminals for cross-section of Cable length 0.1 1.5 mm 2 (connections interchangeable) Max. 10 meters Standards, directives, and approvals Product standard EN 607-1. Automatic electronic controls for household and similar use. Product family standard EN 50491-x General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS). Electromagnetic compatibility (application) For residential, commercial, and industrial environments. EU Conformity (CE) EAC Conformity CE1E2732en*) Eurasia Conformity *)These documents can be downloaded at the following Internet address: http://siemens.com/bt/download 5 / 8

Degree of protection Environmental compatibility Protection class III as per EN 607 Housing IP40 2) as per EN 60529 Degree of pollution 2 as per EN 607 The product environmental declaration CE1E2732en*) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal) Dimensions Weight Housing material Housing color Device packaged with inserts 2) Fully mounted Refer to dimensions 0.28 kg Plastic ASA+PC White NCS S 0502-G Ambient conditions Operation EN60721-3-3 Transport EN60721-3-2 Storage EN60721-3-1 Environmental conditions Class 3K5 Class 2K3 Class 1K3 Temperature 0 +50 C -25 +70 C -20 +65 C Humidity 5 95 % r.h. <95 % r.h. 5 95 % r.h. (non-condensing) Mechanical conditions Class 3M2 Class 2M2 Class 1M2 Maximum elevation above sea level Min. 700 hpa corresponds to a maximum of 3,000 meters above sea level Connection diagram Water sensor A Connections are interchangeable RF transmitter 6 / 8

Dimensions Dimensions in mm Water sensor 46 3,4 12 2000 8 2732M01 RF Transmitter 22 mm 1 mm 84 mm 2701M01a 42 42 28 28 TOP 42 2702M01 76 mm 84 mm 28 28 12 4,2 42 7 / 8

Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 61 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2010 Technical specifications and availability subject to change without notice. 8 / 8