FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)



Similar documents
Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Connecting the Channel A

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

Determine the desired location fixture and center the coaxial cord location to the electrical box.

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Operating Instructions

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

CortezTM A Kichler Décor Ceiling Fan

Spreader Light Bulb Replacement Instructions

60" TulleTM. Instruction Manual. A Kichler Select ceiling fan

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

PARTS & SERVICE MANUAL for CONTEMPO SERIES WARMER LAMPS

5800 Temperature Sensor Cable Assembly

I NTERFACE CABLE ADAPTER MODULE

Light fixtures are attached permanently to

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

HALO H27RICT. 6" RECESSED DOWNLIGHTING Incandescent. eliminate need for separate wire nuts - simply strip supply wires and push in

DISPLAY & EXH I B I T

Accessorize Your Home with Pendant Lamps

GENUINE PARTS INSTALLATION INSTRUCTIONS

HGS620 Shielded Outlet Termination Instructions

Ceiling Fan Installation Instructions

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

INSTALLATION INSTRUCTIONS

Removing memory and option cards

Installation & Weatherproofing Guide for ENCOM Broadband Radios

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Build Your Own Solar Car Teach build learn renewable Energy! Page 1 of 1

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

Manual for GlobePharma Mini-Press II Rotary Tablet Press

Scottsdale 52 in Ceiling Fan Owne r s manual. Scottsdale Ventilador de Techo de 1,32 Manual del Propietario

Operating Instructions

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

LED MOTION ACTIVATED FLOOD LIGHT

Andersen Electric Window Opener for Andersen Awning and Roof Windows

PGL5/6 - Parking Garage Luminaire Installation Instructions

Tech Bulletin. Hose / Cord Replacement and Required Wraps. Series RT

IntelliChlor Flow-Temperature Switch Replacement Kit Installation Guide

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

AMPSEAL* Automotive Plug Connector and Header Assembly

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

54 LinkTM. Instruction Manual. Includes our new CoolTouch Control System Looks permanent, but goes wherever you go! U.S.

6x 54w SuperZoo T5 HIGH FREQUENCY ELECTRONIC CONTROLLER LUMINAIRE

TECHNICAL GUIDE. For Self-Shielded Guns - 300, 400 and 500 amp SAFETY AND WARRANTY INFORMATION INSTALLATION MAINTENANCE GUIDE TECHNICAL DATA OPTIONS

HARAX circular connector

GE Wireless Devices Battery Replacement

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

IntelliBrite Outdoor Landscape LED Color-Changing Light

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

LIEBERT VNSA Installation Sheet

Instruction Manual. Cable Splicing. Models , HDF1, HDF SS1

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

INSTALLATION MANUAL. Installation Instructions

UNPACKING AND ASSEMBLY

Termination Procedure for No. 12 Series Soldertacts Contacts for Coaxial Cable: D , D

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Bill Conkling July 2012

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

Kiosk Group, Inc. ASSEMBLY INSTRUCTIONS FOR THE STANDALONE. EXQUISITE ipad KIOSK. For ipad Version Tablets.

Medical Lighting. XL4 Patient Light

Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

SAN FRANCISCO. U.S. Patents: 5,951,253; 6,158,964; 6,171,060; 6,250,885 INSTRUCTION MANUAL WARRANTY CERTIFICATE

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Written By: Walter Galan

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

LED MOTION ACTIVATED FLOOD LIGHT

Atlanta CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN

Generator Transfer Switch Model # HTS15-AUTO

8-Ohm Ceiling Speakers For Music and Home Theater

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

Standard Sleep Pod Side Entry Assembly Instructions

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

OPERATING INSTRUCTIONS FOR

Bulb Replacement REPLACING BULBS WARNING

Balun Bulletin- CCTV Systems- Termination

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

FRONT WINDSHIELD SEAL INSTALLATION

Submersion/Insertion Toroidal Sensor

Thermostatic Valve Replacement Cartridge and Rebuild Kit

Mini-led spotlight with magnetic base

Nevco, Inc. Installation Manual

PDI-P10LCD Pre-Tensioned Swivel Cartridge

Transcription:

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) 21T, Rev.4 6-13 IMPORTANT: Before proceeding, retrieve the GLASS SHADE INSTALLATION GUIDE, which is included with the pendant cord set CAUTION: Turn off power to electrical box before installing C B A F *IMPORTANT: When Mounting To Smaller Boxes, It May Be Necessary To Secure Using These Mounting Holes. E G D Note: For optimum performance, an electronic low voltage dimmer should be used. Installation of a low voltage dimmer requires a neutral lead in the switch box for proper wiring. If employing a standard incandescent dimmer, low levels of noise ( buzzing ) may emanate from either the dimmer or transformer. This is usually caused by dimmer/transformer incompatibility and may be eliminated by simply replacing the dimmer. 1. Carefully unpack parts. Remove the Canopy (A) from the Mounting Plate by unscrewing the Retainer (B). Fully remove the Retainer from the threaded nipple, then pull the canopy from the Mounting Plate. IMPORTANT: Refer to the GLASS SHADE INSTALLATION GUIDE to determine the glass support parts that must be installed over the Pendant Cord Set, prior to Step 2. 2. To install the pendant cord, simply unscrew the Set Screw on the Strain Relief (C) to loosen. Now push the cord up through the Retainer, Canopy and then Strain Relief until reaching the desired length. Shorten cord to approx. 6 above the Strain Relief, per instructions on the Glass Installation Guide. Tighten the Set Screw onto cord until the cord is held in place. CAUTION: Overtightening the set screw could pierce cord and prevent pendant from operating. 3. Connect the cord leads to the blue or red transformer wires, and secure with wirenuts (D). If the cord length above the Mounting Plate is more than 6, then you will need to shorten the cord. 4. Install the provided Mounting Screws into the Outlet Box, leaving 1/4 of threading as shown. Attach the house ground wire to the bare copper lead on the Mounting Plate and secure with provided wirenut (E). Connect the electrical leads from the fixture transformer to the house supply wires, black to black, white to white, and secure with wirenuts provided (F). 5. Align the circular openings of the keyhole slots (G) of the Mounting Plate with the Mounting screws. Push the Mounting Plate up over the Outlet Box until tight to ceiling, then rotate the Mounting Plate Counter-clockwise and secure with Mounting Screws. 6. Position canopy over the threaded nipple and secure with Retainer. 7. For assembly of the glass shade, please refer to the GLASS SHADE INSTALLATION GUIDE that is included with the Pendant Cord Set. 8. Restore power.

PENDANT CORD INSTALLATION GUIDE Model U Series -98 (Low Voltage Pendant Set 12V) UKIT.98, Rev.3 8-11 SHORTENING LENGTH OF PENDANT CORD Carefully measure the desired length of cord and cut off the excess. It is important to leave an additional 6 that will be inside the canopy for connection to your transformer. Using the 10 AWG setting, strip off 1-1/2 of outer teflon jacket with a pair of wire strippers. Gently push the silver metal braiding downward on the cord, causing the braiding to create a bubble shape as shown. Using a pointed object, such as a pencil, expand an opening in the silver braiding until the inner conductor is clearly exposed. Once the inner conductor is exposed, it can now be separated from the braiding. Slide the pointed object between the inner conductor and the braiding, as shown. Gently wedge the inner conductor apart from the braiding. Now twist the braiding tightly into a conductor. Strip 1/2 insulation from the inner conductor. The pendant cord is now ready for installation (Refer to the Canopy Instructions). After connection to the transformer, it is recommended that any exposed portion of the braided conductor be wrapped with electrical tape. IMPORTANT: KEEP THESE INSTRUCTIONS FOR YOUR RECORDS Replacement parts for this Low Voltage Pendant Set are as follows (lamp included): #TU210C50-SN.98-50W, 10 clear cordset with Nickel Hardware For Bronze cordset, use Z in place of C and BR in place of SN For 15 cordset, use 215 in place of 210 Lamps Only: #B5510-50W Shielded Flood 12V MR16

GLASS SHADE INSTALLATION GUIDE Use With these Models: Scope (6524xx) 1. Begin by removing the check ring from the Socket Assembly. Next, slide the cord through the opening in the top of the Glass Support Block and then slide the Glass Support Block over the Socket Assembly. A small portion of the lamp socket should extend past the end of the Glass Support Block. 2. The Glass Shade (size may vary) will be positioned as shown below. Align Glass Shade so that the Threaded Posts easily fit through the side holes in the Glass Shade and align with the holes in the Glass Support Block and then thread the Threaded Posts into the Glass Support Block holes. For lamping, plug the MR16 Lamp provided. For relamping never exceed 50 watts, as greater wattages could cause overheating, adversely affecting the life of the luminaire. While performing the remaining instruction steps, care must be taken to keep the Glass Shade and Socket Assembly protected, otherwise breakage may occur. Glass Support Block, must be installed prior to installing cord into the ceiling canopy Threaded Post Socket Assembly Lamp Glass Shade, size may vary

FIXTURE INSTALLATION GUIDE Model T21QP (Low Voltage Quick-Connect Canopy) 21QP, Rev.3 6-10 Caution: Turn off power to electrical box before installing D B A Note: For optimum performance, an electronic low voltage dimmer should be used. Installation of a low voltage dimmer requires a neutral lead in the switch box for proper wiring. F C E If employing a standard incandescent dimmer, low levels of noise ( buzzing ) may emanate from either the dimmer or transformer. This is usually caused by dimmer/transformer incompatibility and may be eliminated by simply replacing the dimmer. G 1. Carefully remove parts from package. 2. Connect the house ground wire to the Bare Copper Lead and secure with wirenut provided (A). Connect the electrical leads from the Transformer to the house supply wires, black to black and white to white, and secure with wirenuts provided (B). 3. Align the Openings (C) on the Canopy with the Threaded Holes (D) on the Supply Box. Push the Canopy over the Supply Box until the Canopy is flush to the ceiling, then secure with the Threaded Screws (E). It is important that the Supply Box is deep enough to allow for the Transformer. 4. Place the Decorative Cover (F) over the threaded nipple on the canopy, then attach the Besa Quick Connect Element (G). The Besa Quick Connect Element is furnished separately. 5. With the power still off, insert bulb of not more than the labeled wattage on the Quick Connect Element. 6. Turn power on.

QUICK CONNECT INSTALLATION GUIDE Model XP-98 Series (Low Voltage Pendant Set 12V) XPKIT.98, Rev.6 8-11 This low voltage Pendant Cord Assembly has been designed to be used with Besa Low Voltage Quick Connect Adapters. Operate with a low voltage transformer (12V) and never wire directly to 120 volts. 1. Making a clean cut, shorten the cord to the desired length. 2. Carefully strip off 1-3/4 of the outer jacket using the Stripping Tool provided. It is important not to damage the inner silver braiding. Practice this step on a scrap section of cord first. 1-3/4 3. Slide the Brass Collar over the braiding. Make sure the Brass Collar does not damage the braiding to ensure a good connection. Gently Tighten Using Pliers 4. Remove the exposed braiding by pulling away from the center conductor, then cutting off excess. Leave 1/16 of braided material or less. 1/8 5. Strip off 1/8 of insulation from the Center Conductor. The exposed stranded wire of the Center Conductor must be tightly wound before proceeding. 6. Feed the wire until it reaches the top set screw position. Confirm by viewing the Center Conductor through the Viewing Hole. Loosen Set Screws, If Necessary 7. The Brass Collar should align with the bottom of the Quick Connect Jack, if not then trim the Center Conductor. 8. Tighten the top set screw first, then the lower. Do not overtighten the set screws and make sure the set screws avoid the seam in the Brass Collar. The pendant can now be installed onto Quick Connect Adapter. Orient So Set Screw Is Not On Seam 9. Insert the post of the Quick Connect Jack into the Quick Connect Adapter. Thread the top half of the conical section until it seats with the adapter. IMPORTANT: KEEP THESE INSTRUCTIONS FOR YOUR RECORDS Replacement parts for this Low Voltage Pendant Set are as follows (lamp included): #XP-210C50-SN.98-50W 10 clear cordset with Nickel Hardware For Bronze cordset, use Z in place of C and BR in place of SN For 15 cordset, use 215 in place of 210 Lamps and Quick Connect Jacks Only: #TQJACK-SN - Nickel Quick Connect Jack #TQJACK-BR - Bronze Quick Connect Jack #B5510-50W Shielded Flood 12V MR16

GLASS SHADE INSTALLATION GUIDE Use With these Models: Scope (6524xx) 1. Begin by removing the check ring from the Socket Assembly. Next, slide the cord through the opening in the top of the Glass Support Block and then slide the Glass Support Block over the Socket Assembly. A small portion of the lamp socket should extend past the end of the Glass Support Block. 2. The Glass Shade (size may vary) will be positioned as shown below. Align Glass Shade so that the Threaded Posts easily fit through the side holes in the Glass Shade and align with the holes in the Glass Support Block and then thread the Threaded Posts into the Glass Support Block holes. For lamping, plug the MR16 Lamp provided. For relamping never exceed 50 watts, as greater wattages could cause overheating, adversely affecting the life of the luminaire. While performing the remaining instruction steps, care must be taken to keep the Glass Shade and Socket Assembly protected, otherwise breakage may occur. Glass Support Block, must be installed prior to installing cord into the ceiling canopy Threaded Post Socket Assembly Lamp Glass Shade, size may vary