MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV



Similar documents
Unified requirements for systems with voltages above 1 kv up to 15 kv

Chapter 1. Network Structures

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

Session Four: Internal Arc Safety in New and Existing Switchgear

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

What s up with Arc Flash?

CAPACITOR BANK TESTING SWP

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

RISK MITIGATION for ELECTRICAL WORK. Feb 2013 San Diego CA

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

The Intelligent AX1 Switchgear for Medium Voltage

4160: THE GREEN 480 MEDIUM VOLTAGE ELECTRICAL SYSTEMS

Circuit Electrical Testing

Live Working equipment from BSD - Germany

INDOOR MEDIUM VOLTAGE SWITCHGEAR UP TO 24kV

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

How To Choose A Transformer

High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

MEDIUM VOLTAGE. Michael Mosman, PE. CCG Facilities Integration Incorporated FACILITIES INTEGRATION INCORPORATED

Metal Enclosed Switchgears Metal Clad Switchgears Gas Insulated RMU's

Electricity at work Safe working practices

Power-Zone 4 Arc Resistant Low Voltage Switchgear

Hazardous location. Definitions

Arc Terminator Active Arc-Resistant Switchgear

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

INDOOR MEDIUM VOLTAGE SWITCHGEAR - UP TO 24kV. A division of ACTOM Pty Ltd

Advantages of Fixed Circuit Breaker Switchgear

New standardized approach to arc flash protection

Electrical Shore Connections / Cold Ironing

Hyperlinks are Inactive

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Switchgear and Metal-Enclosed Bus

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

Choosing the Best Solution for Reducing Arc Energy

The following components are common to most cubicles; this example is an ABB HK cubicle.

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Technical Guide. SKM Arc Flash Line Side vs. Load Side

Part 1 System Modeling & Studies for Existing Systems

Electrical switchgear and safety: A concise guide for users

Installation Instructions for Alarm Module Kit A043F059

Low Voltage Switchgear

How to reduce exposure to arc flash hazards

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

ICM Project Station Infrastructure and Equipment

Choosing for tranquility

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Arc Flash Energy Mitigation Techniques

Engineering Specification

Secondary Unit Substations

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

mit to Original Authorised Issue number Prepared Review date March 2014 copies up Electrified Interim Page 1 Manager National Standards

Electrical Distribution Services for Mining and Metals Industries

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Occupational Health Program Safety Training Series. Lockout/Tagout Safety Awareness Training

Electrical Safety Program

SITE CONTRACTOR PROCEDURES

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

Fusible Disconnect Switch

Tremline Pty Ltd trading as The Hills Bark Blower

QUESTIONS and ANSWERS RFB , Metal Clad Switchgear and Power Control Room

FIREFIGHTER SAFETY. Stay safe during substation fires

MEM10019 Select circuit protection devices by type and rating, fit to switchboards and install earthing

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Intertek Cleeve Road, Leatherhead, Surrey KT22 7SB UK

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Switchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Paralleling Switchgear

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

ARC FLASH HAZARD OVERVIEW. Presented August 13, 2015 WWOA Lake Michigan District by Mead & Hunt, Inc.

Electrical Safety in the Workplace

SIEMENS Transmission and Distribution

Implementation of arc flash mitigating solutions at industrial manufacturing facilities

Transcription:

MEDIUM VOLTAGE SUBSTATION PRACTICES

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

MEDIUM VOLTAGE SUBSTATION PRACTICES This presentation covers some safety aspects and recommended MV substation practices such as phasing, voltage detection, switching and permit to work

INTRODUCTION Over the past decade or more, it has become evident that the skills and competencies of personnel in the electrical field in the South African coal mining industry, such as artisans, supervisors and engineers, have diminished

PROBLEMS EXPERIENCED High turn over of electricians Lack of suitable experience Lack of understanding of the basics of electricity Inadequate suitable candidates to fill available positions Good and experienced personnel emigrating or moving to better jobs Little or no mentorship

SPECIALISED ELECTRICAL WORK On the mines, especially coal, good electrical competencies are not only required for the day to day maintenance and construction work, they are also required for specialised electrical work such as:

SPECIALISED ELECTRICAL WORK Inspection and maintenance of explosion protected apparatus Reading electrical drawings and fault finding Testing, phasing and working with Medium Voltage electrical systems

TYPICAL MINE RETICULATION Power supply from Eskom Small mines up to 5MVA Larger mines up to 40 MVA or more Primary reticulation; typically 22 kv or 33 kv Secondary reticulation; typically 6.6 kv or 11 kv Radial feeders very common Larger mines have dual, parallel and ring feeds Extensive MV reticulation networks on mines Skilled and competent persons required to work on, test, fault find and maintain such networks

HAZARDS ASSOCIATED WITH RETICULATION NETWORKS Back feeds from dual, parallel or ring feeds Old oil filled switchgear Inadequately maintained switchgear Manual switching Old switchgear that is not arc vented or arc contained Incorrect or out of date reticulation drawings Reticulation components not to standard or of adequate specification Electrical protection is not adequate, i.e. settings, relay operation, ratings

FURTHER HAZARDS The assumption that the power is OFF The use of incorrect test equipment Inadequate test procedures Inadequate isolation and locking out procedures Lack of skills Inadequate PPE Inadequate safety procedures

RISKS AND CONESQUENCES Electrocution Explosion Fire Loss of life or limb Loss of equipment Loss of production

SAFETY IMPROVEMENTS WITH RESPECT TO MV SUBSTATION PRACTICES In order to reduce the risk associated with the hazards posed by MV reticulation equipment and networks, a few basic improvements should be implemented. Theses can be summarised as follows:

SAFETY IMPROVEMENTS WITH RESPECT TO MV SUBSTATION PRACTICES The use of correct and approved TESTING APPARATUS

SAFETY IMPROVEMENTS WITH RESPECT TO MV SUBSTATION PRACTICES For voltages greater than 1000 volt, testing to prove the circuit is dead or alive should be by means of a VOLTAGE DETECTOR which has been certified for the correct application For phasing, PHASE COMPARATORS should be used that have been certified for the correct application Training on the correct use of voltage detectors and phase comparators should be implemented The electrician doing the testing should be a competent and authorised electrician

SAFETY IMPROVEMENTS WITH RESPECT TO MV SUBSTATION PRACTICES The implementation of correct PROCEDURES

1 Has the Permit to Work been obtained? 2 Has the PPE been checked? 3 Has the High Voltage Megger been tested? 4 Has the Low Voltage Megger been tested? 5 Has the Voltage Detector been tested? SUBSTATION PROCEDURES 6 Has the Voltage Detector been cleaned correctly? 7 Has the Phase Comparator been tested? 8 Has the Phase Comparator been cleaned correctly? 9 Have the Earthing Straps been checked and tested? 10 Has the Fire Extinguisher been checked? 11 Has the First Aid Box and Stretcher been checked? MEDIUM VOLTAGE CHECKLIST 12 Have you check the Reticulation Drawing for this Substation? 13 Have you identified the correct cables, circuit breakers and isolators? 14 Have you recorded all information and Permit to Work number into the Logbook? 15 Has the Time Setting been set to minimum on the CDG before Voltage Detection or Phasing is done? (Only in a no-load situation). 16 Has the Lockout Procedure been adhered to? 17 Has the Switching Procedure been adhered to? 18 Was the cable tested? 19 Was Earth tested for continuity between cubicle earth bar and main earth reference point? 20 Has the Permit to Work been completed correctly and signed off? YES NO

SAFETY IMPROVEMENTS WITH RESPECT TO MV SUBSTATION PRACTICES No work should be done on systems operating at voltages greater than 1000 volt until the apparatus has been isolated and made safe by a COMPETENT AND AUTHORISED ELECTRICIAN to do MV switching in accordance with the mine s code of practice and procedures for locking- out and for MV switching

SAFETY IMPROVEMENTS WITH RESPECT TO MV SUBSTATION PRACTICES Doing a RISK ASSESSMENT before any work takes place. Work such as switching, testing, isolation and locking out, etc. PLANNING THE TASK ahead before any work takes place

SAFETY IMPROVEMENTS WITH RESPECT TO MV SUBSTATION PRACTICES Implementing a PERMIT TO WORK system

PERMIT TO WORK

SAFETY IMPROVEMENTS WITH RESPECT TO MV SUBSTATION PRACTICES The use of the correct PPE,, such as an approved and tested flash suit

PERSONAL PROTECTIVE EQUIPMENT Face mask or shield Full flash suit Gloves

SAFETY IMPROVEMENTS WITH RESPECT TO MV SUBSTATION PRACTICES COMPETENCY TRAINING of electricians or supervisors required to do any MV work The APPOINTMENT OR AUTHORISATION of persons required to any MV work subject to them been found competent as a result of specialised training received

APPOINTMENT OR AUTHORISATION 1.1 KV 44 KV SWITCHING AUTHORISATION To: Whom it May Concern From: Date of issue: Expiry Date : I, hereby authorize to perform switching operations on switchgear, I.e. Circuit breakers, isolators and links at voltage of 1.1 kv 44 kv on Mine. Area of responsibility: I have cautioned him on all the associated safety aspects and I have found him competent by actual practical tests done, to perform these duties. He is also aware of the MV switching code of practice and lockout procedure. Accepted by: Date: Approved by: Date: Responsible Engineer Note: Equipment is to be treated as live at all times. The four steps to safety are to be applied at all times.

SAFETY IMPROVEMENTS WITH RESPECT TO MV SUBSTATION PRACTICES On job evaluation or planned task observation (PTO)

SAFETY IMPROVEMENTS WITH RESPECT TO MV SUBSTATION PRACTICES The approach for implementing the above improvements should be on a holistic basis since all the above will be beneficial together and not as isolated interventions

TYPICAL MV LOCK-OUT OUT PROCEDURE Complete PERMIT TO WORK PLANNING and RISK ASSESSMENT Correct and approved safety PPE Sign the LOGBOOK (Permit to Work number in logbook) Check the reticulation drawing to identify the circuit breaker, physical IDENTIFICATION of circuit breaker, check for ring feeds Trip, ISOLATE,, rack out LOCK-OUT,, attach Danger Sign and Tag CHECK if equipment is switched off TEST (with approved Voltage Detector) for supply check busbar first then load side Apply EARTHING

FURTHER SUGGESTIONS No oil filled MV switchgear Motorised MV switchgear with remote switching Up to date and proper reticulation drawings Switchgear, transformers, cables, etc. properly identified wrt to reticulation drawing Logbooks Planned maintenance

FURTHER SUGGESTIONS MV switchgear to comply with IEC 62271-200200 (High (High-voltage switchgear and controlgear, Part 200: AC metal-enclosed enclosed switchgear and controlgear for rated voltages above 1 kv and up to and including 52 kv) Type Test: Affects of arcing due to an internal arc Example: Internal Arc Classification (IAC) AFLR 21.5kA for 0.5s

BENEFITS OF SUGGESTED SAFETY IMPROVEMENTS Electrical safety is enhanced Can demonstrate competence in terms of the Mines Health and Safety Act or the Occupational and Safety Act Reduce the likelihood of electrical risk Persons are appointed or authorised and can be held accountable for their actions or the lack of

THANK YOU FOR YOUR TIME ANY QUESTIONS?