IP SAN BEST PRACTICES



Similar documents
IP SAN Best Practices

Dell PowerVault MD Series Storage Arrays: IP SAN Best Practices

A Dell PowerVault MD3200 and MD3200i Series of Arrays Technical White Paper Dell

DELL EQUALLOGIC PS SERIES NETWORK PERFORMANCE GUIDELINES

If you already have your SAN infrastructure in place, you can skip this section.

Using Multipathing Technology to Achieve a High Availability Solution

IP SAN Fundamentals: An Introduction to IP SANs and iscsi

Introduction to MPIO, MCS, Trunking, and LACP

Voice Over IP. MultiFlow IP Phone # 3071 Subnet # Subnet Mask IP address Telephone.

CHAPTER 10 LAN REDUNDANCY. Scaling Networks

Chapter 3. Enterprise Campus Network Design

Objectives. The Role of Redundancy in a Switched Network. Layer 2 Loops. Broadcast Storms. More problems with Layer 2 loops

A Dell Technical White Paper Dell Storage Engineering

CCNP SWITCH: Implementing High Availability and Redundancy in a Campus Network

hp ProLiant network adapter teaming

ADVANCED NETWORK CONFIGURATION GUIDE

Meeting the Five Key Needs of Next-Generation Cloud Computing Networks with 10 GbE

Post-production Video Editing Solution Guide with Quantum StorNext File System AssuredSAN 4000

SAN Conceptual and Design Basics

Deployment Guide. How to prepare your environment for an OnApp Cloud deployment.

The functionality and advantages of a high-availability file server system

Networking Topology For Your System

N5 NETWORKING BEST PRACTICES

Using High Availability Technologies Lesson 12

Expert Reference Series of White Papers. Planning for the Redeployment of Technical Personnel in the Modern Data Center

M.Sc. IT Semester III VIRTUALIZATION QUESTION BANK Unit 1 1. What is virtualization? Explain the five stage virtualization process. 2.

Implementing Storage Concentrator FailOver Clusters

Storage Protocol Comparison White Paper TECHNICAL MARKETING DOCUMENTATION

Layer 3 Network + Dedicated Internet Connectivity

Fiber Channel Over Ethernet (FCoE)

Storage Area Network

VMware Virtual SAN Network Design Guide TECHNICAL WHITE PAPER

Advanced Network Services Teaming

Leased Line + Remote Dial-in connectivity

- Hubs vs. Switches vs. Routers -

Switching in an Enterprise Network

Deployments and Tests in an iscsi SAN

IEEE Congestion Management Presentation for IEEE Congestion Management Study Group

VMware Virtual SAN 6.2 Network Design Guide

Data Networking and Architecture. Delegates should have some basic knowledge of Internet Protocol and Data Networking principles.

Building High-Performance iscsi SAN Configurations. An Alacritech and McDATA Technical Note

Cisco Discovery 3: Introducing Routing and Switching in the Enterprise hours teaching time

Dell EqualLogic Best Practices Series. Dell EqualLogic PS Series Reference Architecture for Cisco Catalyst 3750X Two-Switch SAN Reference

Optimizing Large Arrays with StoneFly Storage Concentrators

How To Configure Voice Vlan On An Ip Phone

Networking and High Availability

Course Contents CCNP (CISco certified network professional)

Data Center Fabric Convergence for Cloud Computing (the Debate of Ethernet vs. Fibre Channel is Over)

Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router iscsi Appliance

Abstract. Avaya Solution & Interoperability Test Lab

CCT vs. CCENT Skill Set Comparison

VoIP network planning guide

High Availability Failover Optimization Tuning HA Timers PAN-OS 6.0.0

Achieving Mainframe-Class Performance on Intel Servers Using InfiniBand Building Blocks. An Oracle White Paper April 2003

RESILIENT NETWORK DESIGN

Abstract. MEP; Reviewed: GAK 10/17/2005. Solution & Interoperability Test Lab Application Notes 2005 Avaya Inc. All Rights Reserved.

SDN CENTRALIZED NETWORK COMMAND AND CONTROL

Cisco Networking Professional-6Months Project Based Training

"Charting the Course...

Overview of Routing between Virtual LANs

Question: 3 When using Application Intelligence, Server Time may be defined as.

Fibre Channel over Ethernet in the Data Center: An Introduction

Can PowerConnect Switches Be Used in IP Multicast Networks?

A Principled Technologies white paper commissioned by Dell Inc.

Data Center Convergence. Ahmad Zamer, Brocade

VMWARE WHITE PAPER 1

AT-S60 Version Management Software for the AT-8400 Series Switch. Software Release Notes

Best Practice and Deployment of the Network for iscsi, NAS and DAS in the Data Center

Guide to TCP/IP, Third Edition. Chapter 3: Data Link and Network Layer TCP/IP Protocols

vsphere Networking vsphere 6.0 ESXi 6.0 vcenter Server 6.0 EN

Juniper Networks EX Series/ Cisco Catalyst Interoperability Test Results. May 1, 2009

Windows Host Utilities Installation and Setup Guide

COURSE AGENDA. Lessons - CCNA. CCNA & CCNP - Online Course Agenda. Lesson 1: Internetworking. Lesson 2: Fundamentals of Networking

SSVP SIP School VoIP Professional Certification

The Shortcut Guide To. Architecting iscsi Storage for Microsoft Hyper-V. Greg Shields

Troubleshooting an Enterprise Network

Synology High Availability (SHA)

VTrak SATA RAID Storage System

How To Build A Clustered Storage Area Network (Csan) From Power All Networks

How To Switch In Sonicos Enhanced (Sonicwall) On A 2400Mmi 2400Mm2 (Solarwall Nametra) (Soulwall 2400Mm1) (Network) (

How To Learn Cisco Cisco Ios And Cisco Vlan

Networking and High Availability

White Paper Creating a Video Matrix over IP

Traditionally, a typical SAN topology uses fibre channel switch wiring while a typical NAS topology uses TCP/IP protocol over common networking

vsphere Networking vsphere 5.5 ESXi 5.5 vcenter Server 5.5 EN

Quantum StorNext. Product Brief: Distributed LAN Client

ESX Server 3 Configuration Guide Update 2 and later for ESX Server 3.5 and VirtualCenter 2.5

Cisco Certified Network Associate Exam. Operation of IP Data Networks. LAN Switching Technologies. IP addressing (IPv4 / IPv6)

L-Series LAN Provisioning Best Practices for Local Area Network Deployment. Introduction. L-Series Network Provisioning

Isilon IQ Network Configuration Guide

Ethernet Storage Best Practices

VXLAN: Scaling Data Center Capacity. White Paper

Dell EqualLogic PS Series iscsi Storage Arrays With Microsoft Windows Server Failover Clusters Hardware Installation and Troubleshooting Guide

Configure IOS Catalyst Switches to Connect Cisco IP Phones Configuration Example

CS268 Exam Solutions. 1) End-to-End (20 pts)

A Dell Technical White Paper Dell PowerConnect Team

Server and Storage Consolidation with iscsi Arrays. David Dale, NetApp

Ten top problems network techs encounter

Transcription:

IP SAN BEST PRACTICES PowerVault MD3000i Storage Array www.dell.com/md3000i

TABLE OF CONTENTS Table of Contents INTRODUCTION... 3 OVERVIEW ISCSI... 3 IP SAN DESIGN... 4 BEST PRACTICE - IMPLEMENTATION... 5 REDUNDANCY... 5 SECURITY... 6 IP SAN NETWORK CONFIGURATION... 7 IP SAN OPTIMIZATION... 8 SUMMARY... 11 September 08 Page 2

INTRODUCTION The intent of this document is to provide guidance for optimizing an IP SAN environment utilizing the Dell MD3000i storage array. The best practices within this document are recommendations to provide a fault tolerant, high performance environment to maximize the capabilities of an MD3000i SAN. The recommendations may be applied according to the requirements of the environment in which the installed storage array or arrays are utilized, and not all best practices may be applicable to all installations. The best practices in this paper are focused on Dell Inc. technology based solutions. iscsi OVERVIEW iscsi is a block-level storage protocol that lets users create a storage network using Ethernet. iscsi uses Ethernet as a transport for data from servers to storage devices or storage-area networks. Because iscsi uses Ethernet, it doesn't suffer from some of the complexity and distance limitations that encumber other storage protocols. The iscsi protocol puts standard SCSI commands into TCP and sends those SCSI commands over standard Ethernet. An iscsi SAN consists of servers - with an iscsi host bus adapter (HBA) or network interface card (NIC) - disk arrays and tape libraries. Unlike other SAN technologies, iscsi uses standard Ethernet switches, routers and cables, and the same Ethernet protocol deployed for communications traffic on LANs (TCP/IP). It can take advantage of the same type of switching, routing and cabling technology used for a LAN. Because iscsi uses SCSI commands, relying on Ethernet only to transport the SCSI commands, operating systems see iscsi-connected devices as SCSI devices and are largely unaware that the SCSI device resides across the room or across town. Most components inside these iscsi devices are very familiar to network professionals, including RAID controllers and SCSI or Fibre Channel drives. The only added feature is the iscsi protocol, which can be run on standard NICs in software or on specialized iscsi silicon or HBAs that off-load the TCP/IP and iscsi protocol. ISCSI is built using two of the most widely adopted protocols for storage (SCSI) and networking (TCP). Both technologies have undergone years of research, development and integration. IP networks also provide the utmost in manageability, interoperability and cost effectiveness. September 08 Page 3

IP SAN DESIGN For an IP SAN, the network infrastructure consists of one or more network switches or equivalent network equipment (routers, switches, etc.). For the purpose of this paper, it is assumed that the network has at least one switching or routing device. While it is possible to connect an MD3000i array to hosts without utilizing a network, directly connecting hosts to arrays is not within the scope of this paper. An IP SAN therefore consists of one or more hosts, connected to one or more storage arrays through an IP network, utilizing at least one switch in the network infrastructure. There are several factors that need to be kept in mind when designing an IP SAN. The importance of these factors will depend on the specific implementation of the IP SAN. These factors include and are not limited to: 1. Redundancy: If data availability is required at all times, a fault tolerant IP SAN should be considered. 2. Security: Depending on your IP-SAN implementation, different security mechanisms can be taken into consideration. This includes dedicated networks, CHAP, array passwords, etc. 3. Network Infrastructure: Components of the network infrastructure like NICs, HBAs, switches, cabling, routing, etc. can affect IP SAN performance and maintainability. 4. Optimization: Depending on the application, various elements of your IP SAN can be tuned for improved performance. Some of these include the ability to use hardware offload engines, jumbo frames, etc. September 08 Page 4

2650 PowerEdge 2650 PowerEdge IP SAN BEST PRACTICES BEST PRACTICE IMPLEMENATATION There are many ways to implement an IP SAN based on need, available resources and intended application. For instance one important but easily overlooked item that can improve the manageability of your IP SAN implementation is to assign a consistent and representative naming scheme to the storage arrays. This is especially useful if the SAN has more than one storage array attached. The blink array feature of the MD Storage Manager can be used to correctly identify each array physically. Some of the general implementation guidelines will be described below. However, one should note that these are general guidelines and may not benefit all applications. Redundancy Redundancy in general is having a second set of hardware and communication paths so that if one piece of hardware on one path breaks down there is a second path that can be utilized. In an IP SAN this can be done with a second controller in the Array and by using two different switches for the iscsi network. The diagram below is a simplified diagram of doing this with a Dell PowerVault MD3000i; the desciptions following provide further discussion of the benefits in doing this. Diagram 1: Fully Redundant MD3000i Config September 08 Page 5

Physical Network Infrastructure: A fully redundant IP SAN is characterized by multiple physical independent iscsi data paths between the hosts and the array. Each data path should be on a separate subnet. iscsi configuration: In the case of an iscsi target like the MD3000i, it is recommended to establish multiple sessions to the storage subsystem from each host. It is recommended to set up one session per port from each of the network cards to each RAID controller module. This method allows one session to restart if a link goes down while not affecting any of the other links. RAID: An appropriate RAID level should be chosen based on your applications. RAID 1 or higher provide some level of redundancy that will be useful in the case of failed physical disks. Each RAID level works best with certain applications and this should be taken into consideration while configuring the MD3000i. Power: Each redundant component of the data path should be on a separate power source. This will ensure that even if one component fails due to a power issue, the alternative path will continue to work. In the same way two power supplies of the MD3000i should be connected to separate power sources. Security The optimal way of ensuring data security on an IP SAN is by implementing an isolated physically independent network for the iscsi data traffic. Besides better security, another benefit of having an isolated network dedicated for storage traffic is the avoidance of networked traffic congestion with other non-storage traffic using the network. VLAN: If physically isolated iscsi networks are not feasible then VLANs can help to seperate iscsi traffic from the general traffic in the network. It is recommended you turn on VLAN Tagging. The MD3000i array supports VLAN tagging. A port can either transmit all tagged IP packets or all non-tagged IP packets. Note: VLAN must be enabled throughout the entire iscsi SAN from the NICS, Switches, and iscsi ports, otherwise, behavior may be inconsistent. To simplify troubleshooting initial deployments, make sure that NICs, switches, and MD3000i storage arrays are fully operational before enabling the VLAN feature solution wide. CHAP: To have secure access between your host and array, target and mutual CHAP authentication should be enabled on the host(s) and storage array(s). Standard CHAP password guidelines should be followed for best security. It is highly recommended to set a password on all devices with your IP SAN. It is advisable to use a strong password that meets standard IT guidelines. September 08 Page 6

IP SAN Network Infrastructure Some of the general implementation guidelines will be described below. However, one should note that these are general guidelines and may not benefit some applications. General Network Practices: Make sure the category rating for the cables used are gigabit Ethernet compliant. (CAT5e, CAT6) Design your network to have the least amount of hops between the array(s) and the host(s). This will greatly reduce your failure points, simplify your manageability, and reduce latency and complexity of your network architecture (particularly in the area of redundancy). Managed switches are recommended because they provide advance features to help you optimize and maintain your network for your application. It is recommend you use auto-negotiation only, since gigabit ethernet networks are designed to always have autonegotiation enabled. If a particular application requires a specific speed/duplex mode, this must be done by changing the advertisement options of the switch. Spanning Tree Protocol: It is recommended that you disable spanning-tree protocol (STP) on the switch ports that connect end nodes (iscsi initiators and storage array network interfaces). If you still decide to enable STP on those switch ports, then you should turn on the STP FastPort feature on the ports in order to allow immediate transition of the ports into forwarding state. (Note: PortFast immediately transitions the port into STP forwarding mode upon linkup. The port still participates in STP. So if the port is to be a part of the loop, the port eventually transitions into STP blocking mode.) Note: PowerConnect Switches default to RSTP (Rapid Spanning Tree Protocol) an evolution in STP that provides for faster Spanning tree convergance and is preferable to STP Note: The use of Spanning-Tree for a single-cable connection between switches or the use of trunking for multiple-cable connections between switches is encouraged. TCP Congestion avoidance: TCP Congestion Avoidance is an end to end flow control protocol that will limit the amount of data sent between a TCP sender and a TCP transmitter. This protocol uses a sliding window to size the data being sent to the TCP reciever. This protocol starts with a small segment size and keeps increasing with each acked segment sent, until a segment is dropped. Once it is dropped TCP starts this over again. Ether Flow Control: Dell recommends that you enable Flow Control on the switch ports that handle iscsi traffic. In addition, if a server is using a software iscsi initiator and NIC combination to handle iscsi traffic, you must also enable Flow Control on the NICs to obtain the performance benefit. On many networks, there can be an imbalance in the network traffic between the devices that send network traffic and the devices that receive the traffic. This is often the case in SAN configurations in which many hosts (initiators) are communicating with storage devices. If senders transmit data simultaneously, they may exceed the throughput capacity of the receiver. When this occurs, the receiver may drop packets, forcing senders to retransmit the data after a delay. Although this will not result in any loss of data, latency will increase because of the retransmissions, and I/O performance will degrade. September 08 Page 7

Note: PowerConnect Switches default to Flow Control being off. The MD3000i will autoconfigure to the switch when Flow control is turned on. Unicast Storm Control: A traffic storm occurs when a large outpouring of packets creates excessive network traffic that degrades network performance. Many switches have traffic storm control features that prevent ports from being disrupted by broadcast, multicast, or unicast traffic storms on physical interfaces. These features typically work by discarding network packets when the traffic on an interface reaches a percentage of the overall load (usually 80 percent, by default). Because iscsi traffic is unicast traffic and can typically utilize the entire link, it is recommended that you disable unicast storm control on switches that handle iscsi traffic. However, the use of broadcast and multicast storm control is encouraged. See your switch documentation for information on disabling unicast storm control Jumbo Frames: Dell recommends that you enable Jumbo Frames on the switch ports that handle iscsi traffic. In addition, if a host is using a software iscsi initiator and NIC combination to handle iscsi traffic, you must also enable Jumbo Frames on the NICs to obtain the performance benefit (or reduced CPU overhead) and ensure consistent behavior. Note: Jumbo Frames must be enabled throughout the entire iscsi SAN from the NICS, Switches, and array ports, otherwise, behavior may be inconsistent. To simplify troubleshooting initial deployments, make sure that NICs, switches, and MD3000i storage arrays are fully operational before enabling jumbo frames. IP SAN Optimization When designing your IP SAN you have to look at various factors in your network and the actual application you are using. There are some general rules that can be used when designing your IP SAN. In order to maximize the data throughput of your storage arrays, all data ports need to be utilized. If your application is IO intensive, utilizing an iscsi offload NICs is recommended. Consider manually balancing your virtual disk ownership so that no single controller is processing an excessive amount of I/O relative to the other controller. The MD3000i supports active/active controllers, with each controller being able to simultaneous process IO. The asymmetric design of the controllers means that a virtual disk (LUN) is owned by a controller and all IO access to the virtual disk is only possible through the owning controller. To take advantage of both the controllers for IO access, virtual disks can be distributed among the controllers. Virtual disk ownership can be modified to balance IO access so as to balance utilization of both controllers. With a host configured for redundant access, if a host loses IO access to a virtual disk through its owning controller, the failover drive will execute ownership transfer from one controller to the other and resume IO access through the new owning controller. September 08 Page 8

The following figure illustrates the active/active asymmetric architecture of the MD3000i. The configuration consists of two virtual disks (Virtual Disk 0 and Virtual Disk 1), with Virtual Disk 0 owned by Controller 0 and Virtual Disk 1 owned by Controller 1. Virtual Disk 0 is assigned to Host 1 and Virtual Disk 1 assigned to Host 2. Diagram 2: MD3000i Controller Configuration Virtual disk ownership defined by the asymmetric architecture ensures that Host 1 accesses Virtual Disk 0 through Controller 0 and Host 2 accesses Virtual Disk 1 through Controller 1. Bandwidth Aggregation: With the MD3000i you can have two Ethernet ports from one host connected to one controller and the badwidth will be aggegated. Set up the MD3000i iscsi driver with a Round Robin Que, this will aggregate all the packets being sent to that controller placing them on each link therefore doubling the available bandwidth. September 08 Page 9

2650 PowerEdge 2650 PowerEdge 2650 PowerEdge IP SAN BEST PRACTICES Diagram 3: MD3000i in a Network Examine your network architecture to ensure there is no bottleneck in the network between the host and array. There are some things we talked about under security that also will help to optimize your IP SAN. Using separate switches to physically isolate the iscsi data traffic, and using VLANs with FastPort turned on. Layer 2 Optimization: When setting up the VLAN through your nework, VLAN tagging can be helpful in routing the iscsi Data Traffic through your network. You can then set priority within the VLAN, but you have to look at all your traffic to determine priorities. If for example your VOIP traffic runs through the same VLAN you need to ensure that voice quality is not hurt, plus you need to look at general internet traffic versus iscsi and VOIP. Layer 3 Optimization: Differentiated Services (DiffServ) gives a good method for managing your traffic. Some switches have a proprietary implementation of this that is called Quality of September 08 Page 10

Service (QoS). DiffServ uses the Differentiated Services Code Point (DSCP) to distinguish between service levels of each IP connection. These service level agreements are on a Per Hop Basis (PHB), as such within the internal corporate network traffic flows can be predictable but once a WAN link leaves the company the Service agreements are no longer valid. There are four levels normally used with DiffServ. 1. Default PHB which is typically best-effort traffic 2. Expedited Forwarding (EF) PHB for low-loss, low-latency traffic 3. Assured Forwarding (AF) behavior group 4. Class Selector PHBs - which are defined to maintain backward compatibility with the IP Precedence field. In order to choose what service level to use you have to examine the needs of the applications connected to the Array. For instance if you have your hosts set up to iscsi boot, or are using Virtualization to hide the array and the guest OS is booting off a C: drive that is actually on the array you must select EF as the data must get there and if there is much delay the host will lock up. On the other land you may want all your traffic coming in from the WWW set to the lowest possible class of AF so it doesn t affect your critical data. SUMMARY An IP SAN is a flexible, easy to deploy and use storage solution for businesses of all sizes. By following the practices recommended in this whitepaper and using regular IT best practices you can have a highly reliable, flexible data storage solution. Remember it is important to design and build out your corporate network with the IP SAN in mind, as your data needs grow so will your data traffic. By following the recommendations in this white paper you will be in a much better position to deal with those changes. September 08 Page 11