Walnut Drying Design and Operation. Selecting Dryer Type. Tray Drying Before 1920. Don Osias Jim Thompson



Similar documents
Energy Efficient Grain Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer

High Moisture Corn Drying and Storage. Kenneth Hellevang, Ph.D., P.E. Extension Engineer & Professor

UNIVERSITY OF ARKANSAS DIVISION OF AGRICULTURE RESEARCH AND EXTENSION COOPERATIVE EXTENSION SERVICE ON-FARM SOYBEAN DRYING AND STORAGE

DRYER VENTING SPECIFICATIONS DRYER SAFETY

HVAC Systems: Overview

Principles of Rice Drying How does rice dry?

Natural Air Drying Corn Paul E. Sumner University of Georgia Biological and Agricultural Engineering Department

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

Grain Drying Concepts and Options

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Fan Applications & System Guide

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

Johnson Air-Rotation Systems

Kiln Drying Basics for the Small Producer

Benefits of. Air Flow Management. Data Center

On-Farm Drying and Storage of Soybeans

Managing Stored Grain

Harvesting, Drying, and Storing Malting Barley

Originators of the Flexible Water Tube design

Tips and Tricks for Estimating Energy Savings. Celeste Cizik, P.E. Project Manager E M C Engineers, Inc.

Energy Efficiency. Energy Efficient Home Cooling:

Evaporative Cooling System for Aquacultural Production 1

Innovent LASER Packaged Fresh Air Conditioning Units

Purpose: To determine the dew and point and relative humidity in the classroom, and find the current relative humidity outside.

Exhaust Calculation Booklet

HVAC Calculations and Duct Sizing

Pool Dehumidification Basics

Environmental Data Center Management and Monitoring

Air Side Economizers and Energy Recovery - Improvements and New Regulations. Richard Lord

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Principals of Condensing Boiler System Design

Case Studies: Infrared Heating in Industrial Applications

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Improving Data Center Energy Efficiency Through Environmental Optimization

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

Managing Heat Stress in Poultry

HVAC. Kitchen Exhaust. rooftop equipment! let s drop on a few exhaust fans! it doesn t get easier!

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.

High Altitude HVAC. Silvertip Integrated Engineering Consultants

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Dehumidification Frequently Asked Questions

SAMPLE COSTS TO HULL AND DRY WALNUTS

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

HVAC Basic Science - System Capacity

Best Practices in HVAC Design/Retrofit

Greenhouse Cooling. Why is Cooling Needed?

Repair, Modify or Replace?? What is the right answer?? By : Joe Mozeika

THE HUMIDITY/MOISTURE HANDBOOK

CE6500 Energy Recovery Ventilator

Wet Bulb Temperature and Its Impact on Building Performance

A Glossary of HVAC Terms:

DURR Thermal Oxidizer Research. 4/27/2004 Intel Corporation Community Meeting

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

about your house Before You Start Renovating Your Basement Moisture Problems Figure 1 Moisture problems to solve

Installation & Operation Manual for Energenics Air-Flow Optimizer

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

An Introduction to Solar Energy. Applications for Agriculture. State of New York. George E. Pataki, Governor

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

The New Data Center Cooling Paradigm The Tiered Approach

Low Cost. Lower Energy Costs. Higher Efficiency.

THE PSYCHROMETRIC CHART AND ITS USE

RPV - RP - RA air handling units

EMERGENCY VAPOR SCRUBBER SYSTEMS

RTO UPGRADE PROVIDES COST SAVINGS AND PERFORMANCE IMPROVEMENTS

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Cooling Capacity CFM in. w.c. (125 Pa)

Defining Quality. Building Comfort. Precision. Air Conditioning

Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions Sponsored by:

Compressed air systems. How to plan, install and operate. Best Practices for Maintenance Management

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Why Do I Need Precision Air Conditioning?

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

By Tom Brooke PE, CEM

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

How To Design A Building In New Delhi

Natural gas heating versus split system heating and the current and future viability of the Natural gas network

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

That s it, that s what we do: air knife drying. Ray Ralph, President R.E. Morrison Equipment Inc.

ENGINEERING DATA. Fan Performance Troubleshooting Guide

Comparing Energy Savings of Different VAV Systems

Commissioning - Construction Documents (Page 1 of 6)

Compressors Buying Guide

TIPS ON ENERGY SAVING

85 F 80 F 50% 75 F 70 F 73.0/ F 10% Figure 1

Energy Savings With Adjustable Frequency Drives. for Centrifugal Fans

Type 1 dryers: Domestic dryers to be used primarily in a family living environment. Residences Individual apartments or condominiums

Pulverized Coal Pipe Testing and Balancing

UDSA - UDSBD unit heater

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

ASPHALT PLANT, NOMINAL PRODUCTION OF 160 T/H, IN

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

Transcription:

Walnut Drying Design and Operation Don Osias Jim Thompson Selecting Dryer Type Tray Drying Before 1920 1

Stack Dryer Energy efficient High capital cost Pothole For small lots High labor cost Hopper-bottom Trailer Low capital cost Need to operate in a building to recirculate air Separate fan & burner for each 12 ton unit. 2

Stadium Low labor cost High capacity - 25 ton increments Grain Bin Large Lots No air recirculation Dryer size Handle peak harvest Nut volume = 80-85 ft 3 /ton Large dryers are built in trailer load increments (12 to 13 tons) Number of lots 3

Bin Geometry Self unloading Pallet bin Self unloading 30 25 Ton Dryer Design Holding Volume for 25 tons of nuts: 25t x 80ft 3 /ton = 2000ft 3 Fan type Airflow Static pressure Fan Selection 4

Fan Selection Centrifugal (squirrel cage) Axial High Volume Slow speed = low energy use Noisy Portable Fan type Airflow Static pressure Fan Selection Airflow Capacity High airflow Faster drying Less MC variability Higher fuel cost Higher electricity cost Higher capital cost 5

Airflow Controls Drying Time Drying Time @ 1 F (h) 40 30 20 40% 30% 20% 0 0 20 30 40 50 60 Airflow (cfm/ft 3 ) Initial Moisture Content Effect of Airflow on Costs 50 40 6 ft bin 25% initial moist. 1 F air temp. dry to 8% on top Cost ($/ton) 30 20 Total operating cost Weight Loss Heating Electricity 0 5 15 25 35 45 Air flow rate per bin volume (cfm/ft 3 ) 25 Ton Dryer Design Airflow for 2000 ft 3 of nuts: 2000 ft 3 x 20 cfm/ ft 3 = 40,000 cfm 6

Static Pressure (in w.c.). Thru nuts Airflow (cfm/ft 3 ) 20 30 Nut depth (ft) 4 6 8 0.1 0.4 0.8 0.4 1.3 2.9 0.9 2.7 6.1. Plus pressure drop at fan inlet and in plenum (<1/2 w.c.) Fan Curve - Table Fan Curve - Graph 7

Inlet Designs Burner before fan Burner after fan Burners Air Pollution Regulations Air Quality Management Districts increasingly strict applying NOx regulations to agricultural applications. Each AQMD has different requirements. Check with your local AQMD before building a new dryer. Low NOx burners readily available but more expensive. 8

Burner Capacity Minimum air temperature during drying season is about 50 F. Air recirculation increases minimum to about 70 F. Maximum outside air temperature during drying = 0+ F. Turn-down ratio, at least to 1 Burner Control System Modulating gas flow control. Flame out detection. Excellent digital controls now better and cheaper than analog or gas bulb. Should meet Safety Codes! Must have PID to use with VFD. Digital communication a plus. 25 Ton Dryer Design Burner capacity for 40,000 cfm: 40,000 cfm x 60,000 Btuh/1,000 cfm = 2.4 million Btuh 60,000 Btuh/00 cfm is a rule of thumb for California conditions, assuming a maximum temperature rise of 60 F. 9

Air Plenum Dimensions Maximum air speed = 1500 fpm 25 Ton Dryer Design Air plenum area: 40,000 cfm / 1500fpm = 27 ft 2 Uniformity of Airflow and Temperature Low airflow to first bin Turning vane Burner

Relative Humidity Drying Time @ 1 F (h) 40 30 20 0 In typical drying weather air heated to 1 F has an RH = 15%. 0 20 30 40 50 60 Relative Humidity (%) Effects of Air Recirculation 40 13 Dry Time (hour) 35 30 25 20 15 Time Gas use 12 11 9 8 7 Gas Use (therms/ton) 0 0.2 0.4 0.6 0.8 6 1.0 Fraction of Air Recirculated Recirculation System 11

Air Recirculation Daytime operation - minimal recirculation Door open Cold air drops out Air Recirculation Nighttime operation - Recirculate 50% when air when off nuts is F cooler than outside air. Partially close door Warm air rises Cost ($/ton) 40 30 20 Drying Costs 6 ft bin 25% initial moist. 1 F air temp. 16.7 cfm/ft3 overdrying natural gas 0 0 electricity 20 30 40 Time (hours) 50 12

Drying Costs No Recirculation 0 80 FPW FPWA 60 hrs W F P 40 20 0 0 20 30 40 50 cfmcuft Drying Costs With Recirculation 0 80 FPW FPWA 60 hrs W F P 40 20 0 0 20 30 40 50 cfmcuft Drying Costs w & wo Recirculation 80 FPW 60 FPWN W WN F FN P 40 Weight Loss Total cost PN 20 Heat Power 0 0 20 30 40 50 cfmcuft 13

Recirculation Myths It rains inside the dryer at night. The air is too wet. Recirculation is useless. If I add some exhaust fans in the roof I can get rid of that wet air and dry better. I do not have a wall between the fan and bins but recirculation works fine. Recirculation is complicated and expensive. Psychrometric Chart Recirculation Psychrometrics 14

Recirculation Myths It rains inside the dryer at night. The air is too wet. Recirculation is useless. If I add some exhaust fans in the roof I can get rid of that wet air and dry better. I do not have a wall between the fan and bins but recirculation works fine. Recirculation is complicated and expensive. Hot Air Rises (Really ) Cold, Wetter, Spend $$ Hot, Dryer, Save $$ Recirculation Myths It rains inside the dryer at night. The air is too wet. Recirculation is useless. If I add some exhaust fans in the roof I can get rid of that wet air and dry better. I do not have a wall between the fan and bins but recirculation works fine. Recirculation is complicated and expensive. 15

Hot Air Rises - Still Cold, Wetter, Spend $$ Hot, Dryer, Save $$ Recirculation Myths It rains inside the dryer at night. The air is too wet. Recirculation is useless. If I add some exhaust fans in the roof I can get rid of that wet air and dry better. I do not have a wall between the fan and bins but recirculation works fine. Recirculation is complicated and expensive. Recirculation Instrumentation Outside Temperature Temperature at Roof Inside Monitor Recirculated Air Flow Keep Plenum Humidity Below 40% 16

Recirculation Myths It rains inside the dryer at night. The air is too wet. Recirculation is useless. If I add some exhaust fans in the roof I can get rid of that wet air and dry better. I do not have a wall between the fan and bins but recirculation works fine. Recirculation is complicated and expensive. Got anymore?? Do Not Over Dry Nut MC variability caused by Differences in maturity Position in bin Airflow Incoming Moisture Content Variability mean range 0 20 30 40 50 60 70 80 Moisture Content (%wb) 17

Simulated MC after 25h of Drying Nut Depth 4 400 ft 3 5 tons 20 cfm/ft 3 8 A 8000 cfm 5 B A Velocity 80 ft/min 160 ft/min Pressure 0.4 in wc 3.5 in wc Motor 2.0 HP 8.0 HP B 4 Nut Depth 400 cuft 5 Tons 20 cfm/cuft 8 A 8000 CFM A B Air velocity 80 fpm 160 fpm Drying Time 21 hr 21 hr Top Moisture % % Bottom Moisture 5% 5% 5 B 18

Moisture Uniformity 5 5 8 400 cuft 5 Tons 8 A A B Velocity 80 ft/min 160 ft/min cfm/ft 3 20 CFM 4000 8000 Pressure 1.0 in wc 3.5 in wc Motor 1.2 hp 8.0 hp B 5 Moisture Uniformity 5 8 400 cuft 5 Tons 8 A A B Velocity 80 ft/min 160 ft/min Drying Time 31 hrs 21 hrs Top MC % % Bottom MC 3.5% 5% Average 5.5% 7.5% B Initial MC Effects Uniformity 19

Moisture Uniformity Define Moisture Content Wet Basis Moisture (Industry Standard) Dry Basis Moisture mwb% Water Pounds Nuts Pounds 90 mdb% 11.1 40 60 90 66.6 60 135 90 150 What is 1% Worth? At 8% MC a lot weighs 25 tons, what does it weigh at 7%, 6%, 5%? MC wb% 8 7 6 5 Weight tons 25.0 24.7 24.5 24.2 Weight difference --- -1.1% -2.1% -3.2% Weight difference --- -538 lb -64 lb -1579 lb 20

Moisture Meters Hand - held Dickey-john John Deere Membrane test Usually brittle at 6%. Applied Instrumentation Minimize Drying in Early Morning Keep burner on during the day 0 F 80 or 60 % 40 20 0 Noon night Noon Time night 21

Expensive Solar Heating Fire Safety Prevent fire by regularly cleaning air plenum. Adjust and control burner to produce short flame. Adequate transition length. Have a water supply available. Extinguish a Fire 1. Turn off burner. 2. Direct a spray of water into fan inlet. 22

Dryer Designs Trends, Problems, Possibilities Trends Shrinking Season Requires More Capacity. Capital costs drive move to longer rows, larger fans & burners. VFDs now cost effective. Electronics allows automation of many tasks. Variable Speed Drives Variable speed or variable frequency drives now readily available. Huge advantage for outdoor dryers. Recirculation better for indoor dryers. Require different burners with combustion air supply. These burners are more expensive and less flexible. 23

Specify Variable Speed Drive Specify Carefully! Must do PID. Someone must program and provide user interface. May cost more than the drive! MUST have proper burner and burner controls! Problems Longer rows, shorter transitions, bigger burners, higher plenum velocities make temperature and air flow uniformity MUCH worse. Pushing burners too hard may increase flame length beyond safe limit. Processors struggling with shorter season also are having increasing problems with moisture variability. Industry needs more dry storage and lot traceability. Uniformity of Airflow and Temperature Low airflow to first bin Turning vane Burner 24

Temperature & Airflow Solutions Profile plates for burners. H, Box, T, or other burner configurations. Must RAMP burner up slowly on startup or when setpoint changes. One or more baffles to create turbulence and mixing Tunnel in a tunnel? Possibilities Find better ways to use electronics. Field to package traceability? Automate dryer tasks like air doors & recirculation. Bin level detection. Automated grading. Computer model can fine-tune dryers. Thank You! 25