UCI274C - Technical Data Sheet



Similar documents
UCI274H - Technical Data Sheet

BCI184E - Technical Data Sheet

PM734F - Technical Data Sheet Winding 28

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

STAMFORD Product Guide

IGSA POWER GENERATION SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUMMINS SERIE 6B. Definiciónes. Potencia Prime. Potencia Stand by. Estos valores son aplicables para el suministro de energía eléctrica continua

SYNCHRONOUS MACHINES

Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Lab 8: DC generators: shunt, series, and compounded.

Automatic Voltage Regulator User s Manual

Physical Address: City: State: Zip Code:

CUKUROVA GENERATOR SYSTEMS

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

FAULT FINDING MANUAL. For Stamford AC Generators

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

CUKUROVA GENERATOR SYSTEMS

R448 & R448 V50 A.V.R.

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

High Efficiency Motor Protection. Industry White Paper

AC-Synchronous Generator

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

Welcome to Linear Controls Quarterly Training

R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V

WIND TURBINE TECHNOLOGY

FAULT FINDING MANUAL For Self Excited and Separately Excited Generators

Basics of Electricity

Rules for Classification and Construction Additional Rules and Guidelines

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Generators TEM. for small hydroelectric power stations. Electric Machines

Verification of Short Circuit Test Results of Salient Poles Synchronous Generator

FIT TIER 2 Application

Diesel Generator Set Model DFMB 60 Hz

Power Quality Paper #3

Synchronous motor. Type. Non-excited motors

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

Diesel Generator Set Model DFHC 60 Hz

Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system

Paralleling Power Sources Which Share a Common Neutral

DIESEL GENERATOR SETS

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Torque motors. direct drive technology

FREQUENCY CONTROLLED AC MOTOR DRIVE

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Solving VFD-sourced Bearing Current Problems in AC Motors.

Mounting Instructions. Torque Transducer. A en

SHIP SERVICE GENERATORS (AC)

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

Spark-ignited generator set

Application Information

CUKUROVA GENERATOR SYSTEMS

R450 T DETECT. 3 PH 3 PH. SENSING 7000 / 8000 RAPIDE FAST RAPIDE VOLTAGE 80V ~ 320V SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

The reliability of the grid

C Standard AC Motors

Appendix N: GENERATOR DATA SHEET FOR SYNCHRONOUS GENERATORS CONNECTED TO PG&E ELECTRIC SYSTEM

Diesel Engine Driven Generators Page 1 of 6

ET 332b Ac Electric Machines and Power Systems

Installation, Service & Maintenance Manual

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Annex-A TECHNICAL SPECIFICATION

Unit 33 Three-Phase Motors

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

Offshore Platform Powered With New Electrical Motor Drive System

Installation, Service & Maintenance Manual

Understanding the Alternator

Single-Phase AC Synchronous Generator

SAMPLE OF THE STUDY MATERIAL PART OF CHAPTER 3. Symmetrical Components & Faults Calculations

SX460. Generator Automatic Voltage Regulator Operation Manual

How the efficiency of induction motor is measured?

DIRECT CURRENT GENERATORS

Thyristor-controlled power supplies and battery chargers

INSTALLATION, SERVICE AND MAINTENANCE MANUAL

Type SA-1 Generator Differential Relay

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

Table of Contents. TransformerIQ FAQs 1

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Motor Fundamentals. DC Motor

USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SUPPLY TO A THREE-PHASE AC FOR CONTROLLING THE SPEED OF A THREE-PHASE INDUCTION MOTOR BY USING A THREE-PHASE TO THREE-PHASE CYCLOCONVERTER

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

The following table shows approximate percentage wise the

How To Control A Power Command Powerplant

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Diesel Generator Set Model DGDK 60 Hz

Transcription:

- Technical Data Sheet

SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000, VDE 030, NEMA MG1-32, IEC34, CSA C22.2-0, AS139. Other standards and certifications can be considered on request. VOLTAGE REGULATORS SX460 AVR - STANDARD With this self excited control system the main stator supplies power via the Automatic Voltage Regulator (AVR) to the exciter stator. The high efficiency semiconductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three phase full wave bridge rectifier. This rectifier is protected by a surge suppressor against surges caused, for example, by short circuit. SX440 AVR With this self-excited system the main stator provides power via the AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by a surge suppressor against surges caused, for example, by short circuit or out-of-phase paralleling. The SX440 will support a range of electronic accessories, including a 'droop' Current Transformer (CT) to permit parallel operation with other ac generators. If 3-phase sensing is required with the self-excited system, the SX421 AVR must be used. SX421AVR This AVR also operates in a self-excited system. It combines all the features of the SX440 with, additionally, three-phase rms sensing for improved regulation and performance. Over voltage protection is provided via a separate circuit breaker. An engine relief load acceptance feature is built in as standard. MX341 AVR This sophisticated AVR is incorporated into the Stamford Permanent Magnet Generator (PMG) control system. The PMG provides power via the AVR to the main exciter, giving a source of constant excitation power independent of generator output. The main exciter output is then fed to the main rotor, through a full wave bridge, protected by a surge suppressor. The AVR has in-built protection against sustained over-excitation, caused by internal or external faults. This de-excites the machine after a minimum of seconds. An engine relief load acceptance feature can enable full load to be applied to the generator in a single step. If three-phase sensing is required with the PMG system the MX321 AVR must be used. We recommend three-phase sensing for applications with greatly unbalanced or highly non-linear loads. MX321 AVR The most sophisticated of all our AVRs combines all the features of the MX341 with, additionally, three-phase rms sensing, for improved regulation and performance. Over voltage protection is built-in and short circuit current level adjustments is an optional facility. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 1th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. TERMINALS & TERMINAL BOX Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2. for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 600-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. 2

WINDING 311 CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G. A.V.R. MX321 MX341 VOLTAGE REGULATION ± 0. % ± 1.0 % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) CONTROL SYSTEM SELF EXCITED A.V.R. SX460 SX440 SX421 VOLTAGE REGULATION ± 1. % ± 1.0 % ± 0. % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT INSULATION SYSTEM CLASS H PROTECTION IP23 RATED POWER FACTOR 0.8 STATOR WINDING DOUBLE LAYER CONCENTRIC WINDING PITCH TWO THIRDS WINDING LEADS 12 STATOR WDG. RESISTANCE 0.09 Ohms PER PHASE AT 22 C SERIES STAR CONNECTED ROTOR WDG. RESISTANCE 1.12 Ohms at 22 C R.F.I. SUPPRESSION BS EN 600-6-2 & BS EN 600-6-4,VDE 087G, VDE 087N. refer to factory for others WAVEFORM DISTORTION NO LOAD < 1.% NON-DISTORTING BALANCED LINEAR LOAD <.0% MAXIMUM OVERSPEED 220 Rev/Min BEARING DRIVE END BALL. 631-2RS (ISO) BEARING NON-DRIVE END BALL. 63-2RS (ISO) 1 BEARING 2 BEARING WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR WR² INERTIA SHIPPING WEIGHTS in a crate PACKING CRATE SIZE 406 kg 131 kg 133.78 kg 1.0288 kgm 2 439 kg x 67 x 3(cm) 0 420 kg 131 kg 122.82 kg 0.9781 kgm 2 42 kg x 67 x 3(cm) TELEPHONE INTERFERENCE COOLING AIR THF<2% 0.14 m³/sec 90 cfm TIF<0 0.617 m³/sec 1308 cfm VOLTAGE SERIES STAR 380/220 400/231 41/240 440/24 416/240 440/24 460/266 480/277 VOLTAGE PARALLEL STAR 190/1 200/11 208/120 220/127 208/120 220/127 230/133 240/138 VOLTAGE SERIES DELTA 220/1 230/11 240/120 24/127 240/120 24/127 266/133 277/138 kva BASE RATING FOR REACTANCE VALUES 0 0 0 n/a 112. 117. 117. 12 Xd DIR. AXIS SYNCHRONOUS 2.4 2.21 2.0-2.76 2.8 2.36 2.30 X'd DIR. AXIS TRANSIENT 0.20 0.18 0.17-0.24 0.22 0.21 0.20 X''d DIR. AXIS SUBTRANSIENT 0.14 0.13 0.12-0.16 0.1 0.14 0.13 Xq QUAD. AXIS REACTANCE 1.9 1.43 1.33-1.8 1.48 1.3 1.32 X''q QUAD. AXIS SUBTRANSIENT 0.18 0.16 0.1-0.23 0.21 0.20 0.19 XL LEAKAGE REACTANCE 0.07 0.06 0.06-0.08 0.07 0.07 0.07 X2 NEGATIVE SEQUENCE 0.16 0.14 0.13-0.19 0.18 0.16 0.16 X0 ZERO SEQUENCE 0. 0.09 0.08-0.12 0.11 0. 0. REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO 0.028 s 0.001 s 0.8 s 0.007 s 1/Xd 60 3

0 UCI274C Winding 311 THREE PHASE EFFICIENCY CURVES 4

Winding 311 THREE PHASE EFFICIENCY CURVES 60

Winding 311 Locked Rotor Motor Starting Curve MX 0 SX 30 346V 380V 400V 41V 440V 30 346V 380V 400V 41V 440V 2 2 20 20 PER CENT TRANSIENT VOLTAGE DIP 1 PER CENT TRANSIENT VOLTAGE DIP 1 0 0 0 0 10 200 20 300 30 LOCKED ROTOR kva 0 0 0 0 10 200 20 300 30 LOCKED ROTOR kva MX 60 SX 30 380V 416V 440V 460V 480V 30 380V 416V 440V 460V 480V 2 2 20 20 PER CENT TRANSIENT VOLTAGE DIP 1 PER CENT TRANSIENT VOLTAGE DIP 1 0 0 0 0 10 200 20 300 30 400 40 LOCKED ROTOR kva 0 0 0 0 10 200 20 300 30 400 LOCKED ROTOR kva 6

0 UCI274C Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed Based on star (wye) connection. 000 SYMMETRICAL ASYMMETRICAL CURRENT (Amps) 00 0 0.001 0.01 0.1 1 TIME (secs) Sustained Short Circuit = 430 Amps 60 000 SYMMETRICAL ASYMMETRICAL CURRENT (Amps) 00 0 0.001 0.01 0.1 1 TIME (secs) Sustained Short Circuit = 0 Amps Note 1 The following multiplication factors should be used to adjust the values from curve between time 0.001 seconds and the minimum current point in respect of nominal operating voltage : Note 2 The following multiplication factor should be used to convert the values calculated in accordance with NOTE 1 to those applicable to the various types of short circuit : 0 60 3-phase 2-phase L-L 1-phase L-N Voltage Factor Voltage Factor Instantaneous x 1.00 x 0.87 x 1.30 380v X 1.00 416v X 1.00 Minimum x 1.00 x 1.80 x 3.20 400v X 1.07 440v X 1.06 Sustained x 1.00 x 1.0 x 2.0 41v X 1.12 460v X 1.12 Max. sustained duration sec. sec. 2 sec. 440v X 1.18 480v X 1.17 All other times are unchanged The sustained current value is constant irrespective Note 3 of voltage level Curves are drawn for Star (Wye) connected machines. For other connection the following multipliers should be applied to current values as shown : Parallel Star = Curve current value X 2 Series Delta = Curve current value X 1.732 7

Winding 311 / 0.8 Power Factor Class - Temp Rise RATINGS Cont. F - /40 C Cont. H - 12/40 C Standby - 10/40 C Standby - 163/27 C 0 Series Star (V) 380 400 41 440 380 400 41 440 380 400 41 440 380 400 41 440 Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220 Series Delta (V) 220 230 240 24 220 230 240 24 220 230 240 24 220 230 240 24 kva 84.0 84.0 84.0 n/a 0.0 0.0 0.0 n/a 6.0 6.0 6.0 n/a 1.0 1.0 1.0 n/a kw 67.2 67.2 67.2 n/a 80.0 80.0 80.0 n/a 84.8 84.8 84.8 n/a 88.0 88.0 88.0 n/a Efficiency (%) 90.7 91.1 91.3 n/a 89.8 90.3 90.6 n/a 89. 90.0 90.4 n/a 89.2 89.8 90.2 n/a kw Input 74.1 73.8 73.6 n/a 89.1 88.6 88.3 n/a 94.7 94.2 93.8 n/a 98.7 98.0 97.6 n/a 60 Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480 Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240 Series Delta (V) 240 24 266 277 240 24 266 277 240 24 266 277 240 24 266 277 kva 97. 6.3 6.3 112. 112. 117. 117. 12.0 116.3 12.0 12.0 132. 120.0 127. 127. 137. kw 78.0 8.0 8.0 90.0 90.0 94.0 94.0 0.0 93.0 0.0 0.0 6.0 96.0 2.0 2.0 1.0 Efficiency (%) 90.9 91.0 91.4 91. 90.2 90.6 91.0 91.1 90.0 90.2 90.7 90.8 89.8 90.1 90.6 90.6 kw Input 8.8 93. 93.0 98.4 99.8 3.8 3.3 9.8 3.4 1.9 1.3 116.7 6.9 113.2 112.6 121.4 DIMENSIONS 2002 Newage International Limited. Reprinted with permission of N.I. only. Printed in England. PO Box 17 Barnack Road Stamford Lincolnshire PE9 2NB Tel: 00 44 (0)1780 484000 Fax: 00 44 (0)1780 4840 Website: www.newage-avkseg.com TD_UCI274C.GB_11.02_02_GB