ABB i-bus KNX Switch Actuators SA/S Product Information



Similar documents
ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Switch Actuators SA/S

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

KNX-Flash ABB i-bus KNX

ABB i-bus KNX i-bus Tool Product Information

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

ABB i-bus KNX DALI Gateways Product Information

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Catalog. Modular DIN rail components Installation contactors

Technology of Choice Smart Home and Intelligent Building Control ABB i-bus KNX

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

ABB i-bus EIB / KNX Room Controller

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

Three-phase monitoring relay CM-PFE

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

ABB i-bus KNX IP Router IPR/S 2.1

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB i-bus KNX DALI-Gateway DG/S 8.1

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Pluggable interface relays CR-P Pcb relays

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Analog signal converters CC-E I/I Current / current isolators

ABB i-bus EIB Logic Module LM/S 1.1

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S Intelligent Installation Systems ABB

Application Unit, MDRC AB/S 1.1, GH Q R0111

ABB i-bus EIB / KNX Weather Station WS/S 4.1

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

ABB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014

ESB and EN installation contactors Application handbook

ABB i-bus KNX Security Solutions with KNX Security Terminal Product Information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB i-bus KNX Application Manual Lighting

Technical catalogue. Modular DIN rail components Installation contactors

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual

HDL KNX / EIB BUS. Switch Actuators. Guangzhou Hedong Electronic Co.,Ltd (HDL) 1/50

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

49 Series - Relay interface modules A. Features

Product and functional description

13 SERIES. Electronic step relays A

ABB i-bus KNX. Room Solutions. ABB STOTZ-KONTAKT GmbH - 2CDC N0202, page 1

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

48 SERIES Relay interface modules 10 A

Safety technique. Emergency stop module BO 5988 safemaster

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB.

Emirates Palace Abu Dhabi. Room Master The right decision for you and your guests

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Inwall Room Temperature Unit

Basics of Dimming. ISC Learning Centre

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

GSM ATT Modules Simply effective remote control

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

The Interaction of Contactors with PLCs

The application is now available in 8 languages. (German, English, French, Spanish, Italian, Russian, Dutch, Polish)

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Programming Logic controllers

HERZ-Thermal Actuators

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

Smart Home and Intelligent Building Control Energy Effi ciency in Buildings with ABB i-bus KNX

KNX Lighting Control System

MCB Tripping Characteristics. MCB s Knowhow ABB STOTZ KONTAKT ABB STOTZ KONTAKT

Type: DILM50(230V50HZ,240V60HZ) Article No.:

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Inwall 4 Input / 4 Output Module

Application software. Fan coil actuator 2gang RMD. Electrical / Mechanical characteristics : see product information

Electric Rotary Actuator - On/Off or programmable control actuator

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Highly flexible the right KNX/DALI gateway for every requirement

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Type: DILM9 10(24VDC) Article No.:

DC DC CONVERTER 1000W VDC Input / 12VDC Output

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Transcription:

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt, paved the way for the development of modern and safe electrical installations in buildings with the invention of the circuit breaker more than 80 years ago. ABB Stotz-Kontakt today has the complete range for forward-looking electrical installations in its product range with more than 10,000 components. In addition to the products for conventional electrical installation, for more than 20 years, ABB i-bus KNX has been providing flexible, economic and reliable solutions for intelligent installation systems the networked control of all building functions on the basis of the global standard KNX. Today, several million ABB i-bus KNX devices control lighting, blinds, roller shutters, heating valves, air conditioning and climate control systems and other electrical loads in residential buildings, hotels, schools, office buildings, industrial buildings, airports and on ships in more than 60 countries. The technical and functional demands made on the ABB i-bus KNX devices are as numerous and diverse as the connected electrical loads. 2 2CDC 505 101 D0201

A Complete Range Switch Actuators are responsible for reliable switching of different electrical loads in the KNX system. Many different load situations are possible. ABB offers a suitable Switch Actuator for all application areas. The range has been rounded off with a new series. Now 16/20 AX C-Load Switch Actuators with and without a current detection feature are available; each featuring 2, 4, 8 or 12 outputs. In the following table, you will find an overview of the ABB i-bus Switch Actuators and their type designations: 16/20 AX C-Load with or without Current Detection SA/S 2.10.1 SA/S 2.16.1 SA/S 2.16.5.1 SA/S 2.16.6.1 SA/S 4.6.1 SA/S 4.10.1 SA/S 4.16.1 SA/S 4.16.5.1 SA/S 4.16.6.1 SA/S 8.6.1 SA/S 8.10.1 SA/S 8.16.1 SA/S 8.16.5.1 SA/S 8.16.6.1 SA/S 12.6.1 SA/S 12.10.1 SA/S 12.16.1 SA/S 12.16.5.1 SA/S 12.16.6.1 Note: The codes represent the following: SA/S x.y.z.w x = number of outputs (2, 4, 8 or 12) y = rated current in Ampere (6, 10, 16) z = load type specification: 1 = type for resistive loads (AC1 switching capacity) 5 = type with higher switch capacity C-Load (200 μf) 6 = type with higher switch capacity C-Load (200 μf) and current detection w = version number (optional) 2CDC 505 101 D0201 3

Simple and Safe Installation Simple connection The use of a 6 mm terminal and a universal head screw makes connecting cables with large diameters easy: Load current circuits (2 terminals per relay) Universal head screw terminal (PZ 1): 0.2 4 mm 2 stranded, 2 x 0.2 2.5 mm 2, 0.2 6 mm 2 solid, 2 x 0.2 4 mm 2 Ferrules without/with plastic sleeves: 0.25 2.5/4 mm 2 TWIN ferrules: 0.5 2.5 mm 2. Simple supply An auxiliary voltage supply is not required for device function. The device is supplied by the KNX bus voltage. Simple test After connection of the loads, the installation can be directly manually tested on the devices with manual operation. The function is possible without bus voltage. High relay loading capacity Reliable switching for all intelligent installation system applications. The Switch Actuators are suitable for fitting in distribution boards or small housings, fixed by snap-on mounting on a 35 mm mounting rails. They are electrically connected via screw terminals. The supplied bus terminal is used for connection to the KNX network. 4 2CDC 505 101 D0201

Overview of Switching Performance The following table shows the rated values, switching capacities, lamp loads and/or the number of lamps that can be connected to each contact. SA/S 2.10.1 SA/S 2.16.1 SA/S 2.16.5.1 SA/S 2.16.6.1 SA/S 4.6.1 SA/S 4.10.1 SA/S 4.16.1 SA/S 4.16.5.1 SA/S 4.16.6.1 SA/S 8.6.1 SA/S 8.10.1 SA/S 8.16.1 SA/S 8.16.5.1 SA/S 8.16.6.1 SA/S 12.6.1 SA/S 12.10.1 SA/S 12.16.1 SA/S 12.16.5.1 SA/S 12.16.6.1 I n Rated current (A) 6 A 10 AX 16 A 16/20 AX C-Load 16/20 AX C-Load U n rated voltage (V) 250/440 V AC 250/440 V AC 250/440 V AC 250/440 V AC 250/440 V AC AC1 operation (cos ϕ = 0.8) EN 60947-4-1 6 A 10 A 16 A 20 A 20 A AC3 operation (cos ϕ = 0.45) EN 60947-4-1 6 A 8 A 4) 16 A 16 A C-Load switching capacity 20 A 20 A Fluorescent lighting load AX to EN 60669-1 6 A (35 μf) 3) 10 AX (140 μf) 3) 16 A (70 μf) 3) 20 AX (200 μf) 3) 20A X (200 μf) 3) Minimum switching capacity 10 ma/12 V 100 ma/12 V 100 ma/12 V 100 ma/12 V 100 ma/12 V DC current switching capacity (resistive load) 7 A/24 V = 10 A/24 V = 16 A/24 V = 20 A/24 V = 20 A/24 V = Mechanical contact endurance > 10 7 > 3 x 10 6 > 3 x 10 6 > 10 6 > 10 6 Electronic endurance to IEC 60947-4-1: Rated current AC1 (240 V/0.8) 100,000 100,000 100,000 100,000 100,000 Rated current AC3 (240 V/0.45) 15,000 30,000 30,000 30,000 30,000 Rated current AC5a (240 V/0.45) 15,000 30,000 30,000 30,000 30,000 Incandescent lamp load at 230 V AC 1200 W 2500 W 2500 W 3680 W 3680 W Fluorescent lamp T5 / T8: Uncorrected 800 W 2500 W 2500 W 3680 W 3680 W Parallel compensated 300 W 1500 W 1500 W 2500 W 2500 W DUO circuit 350 W 1500 W 1500 W 3680 W 3680 W Low-voltage halogen lamps: Inductive transformer 800 W 1200 W 1200 W 2000 W 2000 W Electronic transformer 1000 W 1500 W 1500 W 2500 W 2500 W Halogen lamps 230 V 1000 W 2500 W 2500 W 3680 W 3680 W Dulux lamps: Uncorrected 800 W 1100 W 1100 W 3680 W 3680 W Parallel compensated 800 W 1100 W 1100 W 3000 W 3000 W Mercury-vapour lamps: Uncorrected 1000 W 2000 W 2000 W 3680 W 3680 W Parallel compensated 800 W 2000 W 2000 W 3000 W 3000 W Sodium vapour lamps: Uncorrected 1000 W 2000 W 2000 W 3680 W 3680 W Parallel compensated 800 W 2000 W 2000 W 3000 W 3000 W Max. peak inrush-current Ip (150 μs) 200 A 400 A 400 A 600 A 600 A Max. peak inrush-current Ip (250 μs) 160 A 320 A 320 A 480 A 480 A Max. peak inrush-current Ip (600 μs) 100 A 200 A 200 A 300 A 300 A Number of electronic ballasts (T5/T8, single element): 2) 18 W (ABB EVG 1 x 18 SF) 10 ballasts 23 ballasts 23 ballasts 26 1) ballasts 26 1) ballasts 24 W (ABB EVG 1 x 24 CY) 10 ballasts 23 ballasts 23 ballasts 26 1) ballasts 26 1) ballasts 36 W (ABB EVG 1 x 36 CF) 7 ballasts 14 ballasts 14 ballasts 22 ballasts 22 ballasts 58 W (ABB EVG 1 x 58 CF) 5 ballasts 11 ballasts 11 ballasts 12 1) ballasts 12 1) ballasts 80 W (Helvar EL 1 x 80 SC) 3 ballasts 10 ballasts 10 ballasts 12 1) ballasts 12 1) ballasts 1) The number of ballasts is limited by the protection with B16/B20 circuit-breakers. 2) For multiple element lamps or other types the number of electronic ballasts must be determined using the peak inrush current of the electronic ballasts. 3) The maximum inrush-current peak may not be exceeded. 4) Not intended for AC3 operation; maximum AC3 current see Technical data. 2CDC 505 101 D0201 5

This is How Your Project Works Universal application functionality The application software common to all ABB i-bus KNX Switch Actuators offers a wide range of functionality and enables suitable device functionality. The application has a structured configuration: Only the required functions are activated. The parameters and communication objects not required are not displayed. This enhances the clarity and simplifies commissioning. In addition to the well-proven function options, the application program for the C-Load types offers an additional copy and exchange function for parameterised output channels. This simplifies commissioning and prevents errors when the same parameter settings are to be used on several output channels. Using a conversion function, the parameter settings and the group addresses of the predecessor types can be simply uploaded into the new application. Thus, a problem-free exchange or modification of actuators is guaranteed. 6 2CDC 505 101 D0201

Copying and Exchanging Parameter Settings Parameterization of devices can take a lot of time depending on the complexity of the application and the number of device outputs. To optimize the commissioning work, the new copy and exchange function can be used to copy or exchange parameter settings of a channel with other freely selectable channels. Optionally, the group addresses can be retained, copied or deleted in the target channel. The copying function is ideal, particularly for devices, where several channels have identical parameter settings. The exchange of parameter settings is useful, for example, should the terminals be swapped when wiring. The exchange function makes time-consuming rewiring or manual reprogramming of parameters unnecessary. Application example Copying channels A B C D A B C D Convert devices Furthermore, within the range of the C-Load devices, all devices can be simply exchanged with one another via a conversion function, or the settings of one device can be copied into another device. If the number of outputs of the target device is larger than the number of outputs of the source device, only the first outputs of the target device are programmed with the converted data of the source device. The remaining outputs are reset to the factory settings. Thus, for example, a subsequent expansion of the device function with current detection is easy to implement by exchange of the device and conversion. Complex reprogramming of the parameters is unnecessary. These new help functions do not just simplify commissioning, they also reduce the possible sources of errors. 4-fold device without current detection 4-fold device without current detection A B C D 4-fold device with current detection A B C D 8-fold device with current detection 2CDC 505 101 D0201 7

with Current Detection Signal Operating States, Detect Faults SA/S Lighting Heating Power in Current detection Motor M ABB i-bus KNX Switch Actuators with current detection are used predominantly if feedback of the actual status of the connected load is important. This provides transparency about the state of the building and simplifies monitoring. On the ABB i-bus Switch Actuators with Current Detection, ABB improved the load current detection by a factor of 4 in comparison to preceding types. The maximum load current per output is 20 A. Thus monitoring of the loads from 0.02 to 20 A is possible and that at an accuracy of +/- 2% of the measured value and a resolution of 0.02 A. The measured value (RMS value) can be sent as a 2 byte or 4 byte value on the KNX bus or can be evaluated directly. The response of the switch outputs can be set in dependence on the measured load currents via a threshold function. 8 2CDC 505 101 D0201

An Overview of all Software Functions Overview The following table provides an overview of the functions possible with the Switch Actuators and their application programs: SA/S 2.10.1 SA/S 2.16.1 SA/S 2.16.5.1 SA/S 2.16.6.1 SA/S 4.6.1 SA/S 4.10.1 SA/S 4.16.1 SA/S 4.16.5.1 SA/S 4.16.6.1 SA/S 8.6.1 SA/S 8.10.1 SA/S 8.16.1 SA/S 8.16.5.1 SA/S 8.16.6.1 SA/S 12.6.1 SA/S 12.10.1 SA/S 12.16.1 SA/S 12.16.5.1 SA/S 12.16.6.1 Type of installation MDRC MDRC MDRC MDRC MDRC Number of outputs 4/8/12 2/4/8/12 2/4/8/12 2/4/8/12 2/4/8/12 Module width (space unit) 2/4/6 2/4/8/12 2/4/8/12 2/4/8/12 2/4/8/12 Manual operation Contact position display In rated current (A) 6 A 10 AX 16 A 16/20 AX C-Load 16/20 AX C-Load Current detection Switch function ON/OFF delay Staircase light Warning before end of staircase lighting Staircase lighting time set via object Flashing Switch response can be set (N.O./N.C.) Thresholds Current detection Threshold value monitoring Measured value detection Function Scene Function Logic Logic AND function Logic OR function Logic XOR function Gate function Priority object/forced operation Heating/fan control Switch ON/OFF (2 point control) Cyclical fault monitoring Automatic purging Fan Coil control 1) Special functions Default position on bus voltage failure/recovery Status messages 1) See special ABB i-bus KNX devices of the HVAC area, e.g. Fan/Fan Coil actuator LFA/S or Fan Coil actuator FCA/S. = possible functions 2CDC 505 101 D0201 9

Device Overview Type Description MW ** Order code bbn 40 16779 EAN Weight 1 pcs kg Pack unit pcs. SA/S 4.6.1 Switch Actuators, 6 A, MDRC SA/S 4.6.1 4-fold 2 2CDG 110 036 R0011 64384 9 0.16 1 SA/S 8.6.1 8-fold 4 2CDG 110 037 R0011 64424 2 0.26 1 SA/S 12.6.1 12-fold 6 2CDG 110 038 R0011 64423 5 0.35 1 SA/S 8.6.1 Switch Actuators, 10 AX, MDRC SA/S 2.10.1 2-fold 2 2CDG 110 039 R0011 64422 8 0.18 1 SA/S 4.10.1 4-fold 4 2CDG 110 040 R0011 64421 1 0.29 1 SA/S 8.10.1 8-fold 8 2CDG 110 041 R0011 64420 4 0.51 1 SA/S 12.10.1 12-fold 12 2CDG 110 042 R0011 64419 8 0.74 1 SA/S 12.6.1 Switch Actuators, 16 AC1, MDRC SA/S 2.16.1 2-fold 2 2CDG 110 062 R0011 64877 6 0.17 1 SA/S 4.16.1 4-fold 4 2CDG 110 063 R0011 64876 9 0.29 1 SA/S 8.16.1 8-fold 8 2CDG 110 064 R0011 64875 2 0.51 1 SA/S 12.16.1 12-fold 12 2CDG 110 082 R0011 65928 4 0.67 1 SA/S 2.16.5.1, SA/S 2.16.1, SA/S 2.10.1, SA/S 2.16.6.1 Switch Actuator, 16/20 AX, C-Load, MDRC SA/S 2.16.5.1 2-fold 2 2CDG 110 132 R0011 70827 2 0.21 1 SA/S 4.16.5.1 4-fold 4 2CDG 110 133 R0011 70828 9 0.38 1 SA/S 8.16.5.1 8-fold 8 2CDG 110 134 R0011 70829 6 0.69 1 SA/S 12.16.5.1 12-fold 12 2CDG 110 137 R0011 71107 4 0.9 1 SA/S 8.16.6.1, SA/S 8.10.1 SA/S 8.16.5.1, SA/S 8.16.1 Switch Actuator, 16/20 AX, C-Load with Current Detection, MDRC SA/S 2.16.6.1 2-fold 2 2CDG 110 112 R0011 70830 2 0.21 1 SA/S 4.16.6.1 4-fold 4 2CDG 110 113 R0011 70831 9 0.38 1 SA/S 8.16.6.1 8-fold 8 2CDG 110 114 R0011 70832 6 0.69 1 SA/S 12.16.6.1 12-fold 12 2CDG 110 138 R0011 76516 9 0.90 1 ** Module width in space units = 18 mm SA/S 12.16.5.1, SA/S 12.10.1 SA/S 12.16.1, SA/S 12.16.6.1 10 2CDC 505 101 D0201

Quick and Up-to-Date Information www.abb.com/knx 2CDC 505 101 D0201 11

Contact ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Phone: +49 6221 701 607 Fax: +49 6221 701 724 e-mail: knx.marketing@de.abb.com Further Information and Local Contacts: www.abb.com/knx Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB AG. Copyright 2011 ABB All rights reserved Order Number 2CDC 505 101 D0201 printed in Germany (06/11-2-ZVD)