Grit Removal Systems Simple, low cost, effective grit removal to enhance plant performance

Axial and Mixed Flow Pumps for Large Volume Pumping

No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps

VERTICAL TURBINE AND PROPELLER PUMPS

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

SJT / SJM / SJP Large Vertical Pumps

SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE

Vertical Pumps for the Oil & Gas Industry

SIGMA GROUP a. s. Divize průmyslová čerpadla

Flygt 3068, 50Hz. Technical Specification

ROBOT PUMPS RT - TURBOTEX PUMPS

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

Compact pumps from the wastewater experts. FLYGT 3045, 3057, Power range kw.

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

Centrifugal Fans and Pumps are sized to meet the maximum

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains

N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

4.3 Cisterns and Rain Barrels

Dry Pit Solids Handling Pumps

Pumps SELECTION OF A PUMP

Pump Shaft Sleeves - Stratford Engineering

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS

Vertical selfpriming Side-Channel Pumps Type WPV

Module 9: Basics of Pumps and Hydraulics Instructor Guide

CRN A-F-G-E-HQQE 3x400D 50 HZ

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Engineering & Expertise Designing Pump Sumps

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Goulds AF. Axial Flow Pump

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Raptor Septage Acceptance Plant. For Municipal Wastewater, Septage and Grease Trap Applications

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

Engineering & Expertise Designing pump sumps

QL Series Vertical, Double-Suction, Twin-Volute Turbine Pumps

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

Minor losses include head losses through/past hydrants, couplers, valves,

Outline. Objective. Overview Sanitary Drainage System. Design. Materials

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

Multistage high-pressure multistage centrifugal pumps

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS

Tsurumi BER. Submersible Ejectors

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

H i g H E n E r gy, M u lti-stag E, D i ffu s E r type, Bar r E l Cas E, B Oi le r fe E D pu M p

Equipment Information

Use of Corrugated HDPE Products

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

Pure Performance. Steady 1300 Series

Type of Sewer Systems. Solomon Seyoum

Chapter 9 Sanitary Sewers

POSITIVE DISPLACEMENT BLOWERS & VACUUM PUMPS. Water & Wastewater Treatment Solutions

Pollution Control NEW! NEW! Stormwater Attenuation Systems Sustainable Urban Drainage Solutions for Domestic & Commercial Applications. klargester.

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Removing Solids with Automatic Self-Cleaning Filters

BIODISC HIGH PERFORMANCE SEWAGE TREATMENT PLANT FOR DOMESTIC APPLICATIONS

HUBER Vacuum Rotation Membrane VRM Bioreactor

septic systems What is a Septic System? How does a Septic System Work?

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

The conditions below apply to the curves shown on the following pages.

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

MUNICIPAL WASTEWATER PUMP STATION DESIGN PROBLEMS AND SOLUTIONS

High Capacity Helical Piles Limited Access Projects

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

Mechanical shaft seal types and sealing systems

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

BASIS RANGE TMB SERIES

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Pump Skid Fabrication for Magnetic Coupling. Rick Soltis Chief Mechanic City of Bedford

E nv i ro n m e nta l. Biotec 5-7. Sustainable, Reliable, Affordable

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET

WASTE WATER Solutions

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Conlift1, Conlift2, Conlift2 ph+

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

Waste Management. Infrastructure Rehabilitation in the U.S. Virgin Islands

ElectroShade Skylight, Atrium and Monumental Shades

Chapter 3.5: Fans and Blowers

HORIZONTAL PUMPING SYSTEM

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Coast Trunk Sewer Rehabilitation Project for the Orange County Sanitation District

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

Waste Water Solutions

Free Stall Cleaner System with Cable. A new generation of equipment and systems. GEA Farm Equipment Houle

Design recommendations FOR PUMP STATIONS WITH LARGE CENTRIFUGAL FLYGT WASTEWATER PUMPS

SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank.

DECANTER CENTRIFUGE. CENTRIFUGE TECHNOLOGIES

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Water Treatment and Reverse Osmosis Systems

Transcription:

SCREW PUMPS

General Information Several centuries BC, Archimedes the Greek philosopher, developed a turning spirally wound tube to raise water to a higher level for irrigation purposes. Over 100 years ago, this method of raising water was adapted by the Dutch to reclaim land using windmills as the drive system. Founded in 1895, Spaans Babcock adapted Archimedes original wound tube concept and produced their first screw pump from wood. Although today electric motor drives have taken over from windmills and steel from wood, the basic external screw design developed by Spaans over a century ago has stood the test of time and is today the industry accepted standard worldwide. Applications In recent years the demand for screw pumps has increased. Originally designed as a straight forward pump to maintain water levels in the Dutch polders, today the screw pump is recognized as an ideal device in the water management industry having a wide variety of applications providing solutions for: inlet and final effluent pumping in sewage treatment plants inter-stage pumping in sewage treatment plants return and waste sludge pumping in sewage treatment plants irrigation drainage stormwater control industrial process water horizontal flushing pump 2

Concrete Trough Type Concrete Trough The concrete trough is the classic design. The civil engineering contractor first builds a trough roughly 3 inches (70 mm) larger than the outer diameter of the screw pump. After installation of the screw, the bearings and drive baseplates are grouted in place. The required trough is obtained by slowly rotating the screw pump which is fitted with a temporary screed bar and applying a concrete screed until the correct trough profile has been achieved. Steel Trough Liner In certain circumstances the construction of a screeded concrete trough is not always practical, so a prefabricated steel trough liner can be provided. Anchors are attached to the back side of the steel liner and after final positioning, mass concrete is applied behind the steel liner. Both the concrete trough and steel trough liner options require the provision of a separate drive base. Steel Trough Liner Encased Screw Pump Encased Screw Pump This design contains not only a screw and steel trough but includes supports for the lower bearing, upper bearing and drive systems. The extensions for these create the water inlet and a discharge section which together form a prefabricated pumping station requiring the minimum of civil construction and providing scope for significant overall cost savings. 3

D d MPP CP Hh FP TP Terminology Basic design of a screw pump FP Fill Point - Inlet Water Elevation, Screw Pump Capacity = 100 % TP Touch Point, Screw Pump Capacity = 0 % CP Chute Point, Invert of Trough at Discharge MPP Maximum Pumping Point, Maximum Discharge Level Over Chute Point Hh D d ß Maximum Head or Lift Difference of MPP-FP Outside Diameter of Screw Diameter of Torque Tube Inclination Angle (Variable between 22 and 38 Depends on required capacity and head) 4

Optional Equipment ECO bearing ECO Bearing In a world becoming ever more conscious of the need to protect the environment in which we live, we consider this bearing has an important part to play. The sealed for life roller bearing is environmentally friendly being completely enclosed preventing the leakage of lubricant into the pumped liquid. The ECO bearing is fully interchangeable with conventional bearings. Horizontal Flushing Installation This application is used when water systems i.e. canals in urban areas are polluted, contaminated with algae, suffer from oxygen deficiency, etc. To combat the objectionable odors associated with large bodies of standing water which would otherwise become stagnant if not circulated. The horizontal screw pump is an ideal solution for low head circulation pump applications. Horizontal Flushing Installation Two stage pumping station Multiple Stages When high heads are required screw pumps arranged in series could be the solution. 5

Optional Encased Screw Pump G F L H K E 20 CP FP D ESP C A B 6 The Encased Screw Pump, ESP, is a completely assembled, selfcontained screw pump. A steel trough holds the lower bearing at the bottom and upper bearing and drive system at the top. The unit is delivered fully assembled and is easy and quick to lift into place. This eliminates the need for a structural concrete trough and screeding-in-place. There is no limit on size or capacity beyond the normal screw pump. Various drive enclosures can be provided.

High Efficiency The average efficiency ( ) of a screw pump installation operating at maximum capacity is a minimum of 75 %. The graph illustrates a loss of only 10 % efficiency when the screw operates within the range of 100 % down to 33 % of the design capacity. This flat efficiency curve results in significant energy cost savings in combination with variable inlet flow conditions as experienced at a wastewater treatment facility. 100 80 60 40 20 0 Q% % 80 70 60 50 40 30 20 10 0 Q Screw Pump vs Centrifugal Pump The most important difference between both the pump types is the way they operate. A screw pump is ideally suited to handle water containing organic material and inorganic solid particles and operates without the requirement of pre-screening. In order to effectively pump waste water a centrifugal pump impeller must be able to pass solids of not less than 4 inches (100 mm) in order to prevent clogging. Provision of open passage impellers dramatically increases system losses and reduces operating efficiency frequently to as low as 45%, resulting in higher running costs. To avoid clogging a screen has to be built before the pump against high building and maintenance costs. The static head or lift of the screw pump is MPP-FP. A wet well is not required. For a centrifugal pump, a wet well is required to be deep enough to provide the NPSH. In addition, there are also pump inlet and discharge losses to be overcome resulting in a large total head. In most cases the difference between the lift of the screw pump and the total head of the centrifugal pump is significant, requiring a larger size motor. Hstatic Htd : Total Developed Head Hstatic : Actual Lift Required Hsl : Suction Inlet Loss Hww : Wet Well Surface Loss Hdl : Discharge Line Loss Hsl NPSH Hstatic Hdl Htd 7

Materials Screw pump bodies are usually fabricated from steel tubes with flights made from formed steel plate. Stainless Steel screw pumps can be supplied if severe corrosion is expected. Special designs have been developed in the past to cater for handling the following: high sand content water heavily contaminated water sea water high and low ph values Screw Pump Capacity Table Diameter 30 Inclination Angle 35 38 Spaans Babcock Inc. 588 Edward Avenue, Unit 43 Richmond Hill, ON Canada L4C 9Y6 Tel. 905.884.1100 Fax. 905.884.8811 E-mail inch mm 16 400 20 500 24 600 28 700 31 800 35 900 39 1000 43 1100 47 1200 55 1400 63 1600 71 1800 79 2000 87 2200 94 2400 102 2600 110 2800 118 3000 126 3200 134 3400 142 3600 150 3800 157 4000 177 4500 197 5000 mgd l/s 0.5 24 0.9 39 1.4 62 2.1 90 3.4 148 4.4 192 5.7 250 7.1 310 8.7 380 12 540 17 745 22 980 29 1250 35 1550 43 1900 52 2300 62 2700 73 3200 86 3750 98 4300 112 4900 128 5600 145 6350 189 8300 242 10600 mgd l/s 0.4 18 0.7 31 1.1 48 1.6 68 2.6 116 3.5 152 4.5 195 5.6 245 6.8 300 10 430 13 586 18 770 22 980 27 1200 34 1500 41 1800 48 2100 57 2500 67 2950 76 3350 89 3900 100 4400 114 5000 148 6500 189 8300 mgd l/s 0.4 16 0.6 28 1.0 42 1.4 61 2.3 100 2.9 128 3.8 166 4.7 207 5.7 250 8 360 11 500 15 650 20 870 23 1000 29 1280 34 1500 41 1800 49 2160 57 2500 66 2900 75 3300 86 3750 97 4250 128 5600 162 7100 sales@spaansbabcock.net Internet www.spaansbabcock.com