Chloride 80-NET from 60 to 500 kw. Secure Power for Mission Critical Applications



Similar documents
Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Liebert NXC from 10 to 200 kva

Liebert 80-eXL from 100 to 1200 kw. Enhanced Design and Improved Efficiency

Advantages and Efficient Use of Programmable Sockets. By Miguel Rascon AC Power Senior Product Manager

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

4.0 UPS dedicated to ICT for unmatched energy savings

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Eaton 93PM UPS Where aesthetics meet intelligence.

RIELLO ELETTRONICA. Master HP

PowerGem Pro Uninterruptible Power Supply

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Phase Modular Finally the benefits of Modular ups are for all

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Uninterruptible Power Supply Product Regulations and Standardization in the European Union. By Matteo Tricarico Patents and Regulatory Engineer

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Galaxy VM. Three-phase power protection. schneider-electric.com

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Trinergy Cube from 300 kw to 3 MW. Beyond the Power Revolution

Enterprise Remote Monitoring

Eaton 93PM UPS Efficient. Scalable. Innovative.

Eaton 93PM UPS Efficient. Scalable. Innovative.

LAP ENERGIA PARA DATACENTERS

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw

How To Make A Data Center More Efficient

IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

The UPS for the highest security in industry and data centres

Technical Data. back-up time in minutes 100% load % load

ABB central inverters PVS to 1000 kw

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Thyristor-controlled power supplies and battery chargers

GAMATRONIC ELECTRONIC INDUSTRIES LTD.

SG Series UPS kva three phase 400 Vac

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ABB PSPS Erich Steinmann; Generator control-2013

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

How To Make A Fronius Cl Power Inverter

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

Protect. UPS Solutions for large Data centers

The Trellis Dynamic Infrastructure Optimization Platform

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

Uninterruptible Power Supply

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

User s Manual Before using the inverter, you need to read and save the safety instructions.

IT White Paper. N + 1 Become Too Many + 1?

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

POWER. Your Partners in Availability POWER

Disturbance Recoder SPCR 8C27. Product Guide

MPR-Systems. Mini Power Racks 1200 W W

GE Digital Energy. SG-CE Series UPS kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

The Trellis Dynamic Infrastructure Optimization Platform for Data Center Infrastructure Management (DCIM)

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Permissible ambient temperature Operation Storage, transport

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Synthesis Twin. from 6 to 30 kva POWER PROTECTION

UPS system for emergency lighting and smoke extraction

Liebert HPM Designed for top level performance and reliability. Precision Cooling for Business-Critical Continuity

Storage System. Planning Checklist. EC E1, First Edition

Power protection for data centers

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Liebert icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Opportunity of Energy Saving in electrical path is lesser as compared to other areas

SNMP Web Management. User s Manual For SNMP Web Card/Box

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Liebert PPC Second Generation Power Distribution Cabinet

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Standardization and modularity as the foundation of data center UPS infrastructure

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Data centre experts. Advanced power protection for data centres

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

Tough Decision: On-Line or Line-Interactive UPS?

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Transcription:

Chloride 80-NET from 60 to 500 kw Secure Power for Mission Critical Applications

Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative solutions for the benefit of its customers. Emerson Network Power protects and optimizes critical infrastructure for data centers, communications networks, healthcare and industrial facilities. Emerson Network Power s broad technology base and global expertise support a full spectrum of enterprise-wide solutions for today s vital business needs. Regardless of your size, you can t afford for your critical business systems to go down and you can t waste time recovering your IT infrastructure after a disruption. Leave that to us, the experts grid to chip solutions, from the biggest to the smallest data centers, we are ready to serve your needs with the solutions we have developed. More standardization, so you don t need further budget allocations to install it. More simplification so you don t need to be a specialist to get the best for your business. More support, so while you are enjoying doing business, we are protecting you. 2

3

Chloride 80-NET From 60 To 500 kw Maximized active power, high efficiency and complete compatibility for modern, mission critical IT loads. Features and Performance Transformer-free design Full IGBT double conversion technology Full input Power Factor Correction (PFC) and excellent input performances: - PF > 0.99 - THDi < 3% Automatic output power upgrade up to +10% High conversion efficiency (certified up to 98%) Hi-tech user interface for monitoring system status and performance Full galvanic isolation as standard built-in option. Chloride 80-NET 60-500 kw Performances Chloride 80-NET features a transformer-free design with full IGBT double conversion technology allowing it to provide extraordinary savings on installation and running costs, while at the same time providing first class load protection. Chloride 80-NET also features a full IGBT rectifier allowing for reductions in the size of gen sets, circuit protection, cabling and transformers. Flexibility And Compatibility Chloride 80-NET can be fully adapted to meet diverse requirements in terms of battery backup time, power, redundancy and harmonic control. Maximum flexibility is also ensured from: Output Power Factor 1 Output Power Factor diagram symmetrical respect to zero Permanent 100% kva - no derating with any load (lagging or leading) Optimum space/power ratio Full compatibility with static transfer switches Wide range of standard options including: Isolation transformer (integrated in UPS cabinet), System Bypass Switch and Synchronization Module (MBSM). 4

User Interface 1 9 2 3 8 4 5 6 7 1. Bypass Input Voltage, and frequency measurements. 2. Input Current, voltage and frequency values of the three input phases. 3. Warning/fault Alerts of anomalies on bypass, rectifier, inverter, booster/ charger, battery and load. 4. Events log Date and time of important UPS events, alarms and other warnings. 5. Measurements Voltage, current and frequency values of each internal functional block. 6. Battery Status/values including temperature, cell voltage, capacity run time and testing. 7. LIFE Status of the LIFE.net connections and calls. 8. Tools LCD settings and language selection. 9. Output Voltage, current, frequency, and battery measurements. 5

Sustainability And Environment Advanced digital technology and maximum energy savings for increased performance and optimized TCO. Chloride 80-NET s control platform incorporates double DSP and a micro-controller, allowing it to provide the most powerful control in the UPS industry. Together with the patented Vector Control technology it enables an increased performance of power converters and real time control of output power quality. This combination of technology provides the following benefits: Zero impact on upstream equipment Perfect compatibility with generators Enhanced performance for specific unbalanced load conditions Perfect load sharing for parallel configurations Enhanced fault clearing capacity (up to 300% of the inverter nominal current) Intelligent double conversion for maximum reliability and highest energy savings. Maximum Energy Savings As a result of the transformerfree architecture and intelligent double conversion technology, Chloride 80-NET can achieve optimum efficiency values in all operating conditions, making it capable of reducing running costs also at partial load. This architecture also allows for reduced energy dissipation (kw) thus significantly minimizing the consumption of the cooling system. Full Galvanic Isolation Chloride 80-NET is the only UPS in its power range that offers integrated full galvanic isolation, meaning that the isolation transformer is housed inside the UPS cabinet. This greatly reduces the footprint thus providing space saving advantages. In addition, the transformer can be connected to the input or to the output of the UPS, providing: Full galvanic isolation for medical and other critical applications Installation with two independent input sources (with different neutrals) Installation in distribution without neutral. Efficiency (%) 98 0 50 75 100 Load (%) Chloride 80-NET efficiency curve UPS with isolation transformer 6

Respecting The Environment Chloride 80-NET respects the highest level of environmental standards as a result of the following features: Premium energy savings Most silent UPS in its power range Maximized battery life with Advanced Battery Care (ABC). ABC allows the Chloride 80-NET series to maximize the running time of the battery by up to 50% and includes the following main battery care features: Ambient temperature compensated battery charger Automatic battery test (can be set by user at selectable intervals) Time compensated end of discharge voltage Exact determination of remaining battery life thanks to sophisticated algorithms able to analyze real operating conditions such as temperature, discharge/charging cycles and discharge depth. 7

Servicing Critical Infrastructure Proactive equipment maintenance reduces downtime and extends equipment life which in turn maximizes return on investment and increases system availability. Emerson Network Power supports entire critical infrastructures with an extensive service offering, guaranteeing network availability and total peace of mind 24/7. Our approach to servicing critical infrastructure covers all aspects of availability and performance, from single units to entire mission critical systems, providing customers with tailored services to meet their individual business needs and further guaranteeing critical continuity. Emerson Network Power s service program is designed to ensure that your critical power protection system is maintained in an optimum state of readiness at all times. The LIFE remote monitoring and diagnostic service provides early warning of UPS conditions and out of tolerances. This allows effective proactive maintenance, fast incident response and remote trouble shooting, giving customers complete security and peace of mind. Maximize Availability Pre-Emptive Maintenance Regular preventive maintenance increases uptime. Emerson Network Power s LIFE provides early warning of operating anomalies allowing real-time diagnosis and swift identification and resolution. Minimize Downtime Immediate Identification of Problems Should an emergency condition arise, an engineer in the 24/7 manned LIFE service center carries out an immediate fault analysis and instigates appropriate corrective action. Reduce Operating Costs Superior Asset Management Through comprehensive data collection and analysis, LIFE s detailed reporting system provides valuable information on power and equipment trends, over any selected period of time. Connectivity And Tracking Interactive control, connectivity and LIFE remote monitoring and diagnostics allow for real time tracking and fast intervention. Communication Chloride 80-NET features a hitech, 15 language user interface, for closely controlling and monitoring the system status and performance. The UPS offers the following standard communication features: Voltage-free contact ports Digital inputs and outputs Two serial ports and LAN connection Two internal slots for LIFE and connectivity options. Hardware Connectivity ManageUPS NET ensures the monitoring and control of the networked UPS, through the TCP/IP protocol. Two different options permit: The integration of Chloride UPS with Building Monitoring 8

and Automation Systems via MODBUS RTU, MODBUS/TCP or JBUS protocols The monitoring of environmental conditions where the UPS systems are installed. Software Connectivity MopUPS Professional provides the safe shutdown of the operating system in the event of an interruption to the load. This includes event logging and gives notifications via e-mail. ManageUPS CIO software provides a central management system for critical power infrastructures distributed within a building, campus or wide area network environment. Servicing And Security The Chloride 80-NET s modular drawer-design allows modules to be removed easily by extracting the drawers from the front of the UPS. This architecture considerably minimizes the time needed for repairs and optimizes installation and serviceability. Each UPS will be equipped with an ID card, including all UPS working parameters. This card, univocally related to the UPS, shortens UPS off time in the case that the control board needs to be replaced. Trellis Platform Emerson Network Power s Trellis platform is a real-time infrastructure optimization platform that enables the unified management of data centre IT and facilities infrastructure. The Trellis platform software can manage capacity, track inventory, plan changes, visualize configurations, analyze and calculate energy usage, and optimize cooling and power equipment as well as enable for virtualization. The Trellis platform monitors the data center, providing a thorough understanding of system dependencies to help IT and facilities organizations keep the data center running at peak performance. This unified and complete solution, delivers the power to see the real situation in your data center, make the right decision and take action with confidence. Hardware Connectivity ID card 9

Flexibility And Security Parallel Configurations Chloride 80-NET can be connected with up to eight units in parallel for an increased level of capacity as well as redundancy, thus enhancing its fault management capability by preventing a single point of failure. The parallel architecture of Chloride 80-NET allows single units to be serviced while the remaining units continue to power the load. A single Chloride 80-NET unit can be upgraded to parallel simply, via dedicated and easy to modify software settings. Chloride 80-NET s self configuring, hot plug parallel feature allows the system to automatically detect when new units have been added without the need for stopping the system. This simplified parallel process provides maximum flexibility in terms of scalability for capacity and redundancy. The Loop CAN BUS connection, used to connect the paralleled UPS also allows for unprecedented reliability, perfect load sharing and fast detection of any variation in status of the UPS system. Chloride 80-NET can support both distributed and centralized parallel configurations: Distributed Parallel Configuration Paralleling single Chloride 80-NET units offers advanced scalability. In a distributed parallel configuration each unit has a dedicated static bypass switch, providing parallel operation without the need for a system control cabinet, thus reducing initial installation costs. Bypass Load Chloride 80-NET distributed parallel configuration, with 8 UPS units in parallel. Centralized Parallel Configuration With the Chloride 80-NET s centralized parallel configuration, the internal static bypass switch of each unit is disabled and an external Main Static Switch (MSS) rated for the desired maximum capacity, is installed. Therefore, the reserve supply to the loads operates via one central piece of equipment (MSS). The MSS can be easily integrated into any switchgear, thus simplifying cabling and installation. System level commands are given to the MSS via its integrated touch screen display. Bypass MSS Load Chloride 80-NET centralized parallel configuration, with MSS plus 8 UPS units in parallel. 10

Intelligent Paralleling Feature for Centralized Parallel Configuration Activating the the Main Static Switch (MSS) intelligent paralleling feature optimizes efficiency at partial load, thus achieving superior running cost savings. Enabling this feature allows the system to automatically adapt capacity to meet immediate load requirements by switching excess units to standby mode, while ensuring continued system availability. Furthermore, the Main Static Switch allows each Chloride 80-NET unit to operate in standby mode for the same amount of time, ensuring an equal life-span of module components. This Main Static Switch intelligent paralleling feature further maximizes Chloride 80-NET sdouble conversion efficiency at partial load and allows for an overall energy dissipation reduction. MSS 65% Chloride 80-NET Intelligent Paralleling mode in centralized parallel configuration with MSS Two units @65% load each = 95 % efficiency. 100% 95% 90% 85% 80% Efficiency (%) 0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Load (%) Chloride 80-NET / efficiency with MSS Intelligent Paralleling feature. Intelligent ECO Mode for Centralized Parallel Configuration In a centralized parallel configuration it is possible to activate the intelligent ECO mode feature, thus powering the critical loads through the central main static switch, allowing it to operate at an efficiency up to 98.5%, further maximizing energy savings for an optimized total cost of ownership (TCO). Efficiency (%) 100% 95% 90% 85% 80% 0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Load (%) MSS Intelligent ECO mode efficiency for centralized parallel configuration. 11

Chloride 80-NET Specifications Technical Characteristics Rating (from 60-120 kva) 60 80 100 120 Output active power at 40 C (kw) 60 80 100 120 Apparent nominal output power at 40 C (kva) 60 80 100 120 Apparent nominal output power at 25 C (kva) 66 88 110 132 Input Nominal primary mains input voltage/voltage range (V)* Nominal bypass input voltage/voltage tolerance (V) Nominal input frequency/frequency tolerance (Hz) 400 (250 to 460), three phase + neutral 400 ± 10% (380 V, 415 V selectable) three phase + neutral 50 ± 10% (60 Hz selectable) Input current distortion (THDi) (%) <3 Primary input Power Factor >0.99 Output Nominal output voltage (V) Output voltage stability by load variation 0-100% (%) - static - dynamic Nominal output frequency (Hz) Output frequency variation (%) - with mains synchronization - with internal reference 400 (380 V, 415 V selectable) three phase + neutral ± 1 Complies with IEC/EN 62040-3, Class 1 50 (60 Hz selectable) ± 1 (2, 3, 4 selectable) ± 0.1 Inverter overload capacity Compatibility with loads 125% for 10 min., 150% for 1 min. Any power factor (leading or lagging) up to 1 without output derating; crest factor up to 3:1 Automatic adjustment of nominal output power with temperature 110% at 25 C, 100% at 40 C General Classification according to IEC/EN 62040-3 VFI - SS - 111 Operating temperature ( C) 0-40 Relative humidity (without condensation at 20 C) <95% Protection level IP 20 Frame Color RAL 7016 Noise at 1 m (dba)* 62 62 65 65 / efficiency (%)* up to 98% Parallel configuration up to 8 units Dimensions And Weight Height (mm) 1780 Width (mm) 570 570 845 845 Depth (mm) 858 UPS weight (kg) 290 290 400 400 * Conditions apply 12

Technical Characteristics Rating (from 160-500 kva) 160 200 300 400 500 Output active power at 40 C (kw) 160 200 300 400 500 Apparent nominal output power at 40 C (kva) 160 200 300 400 500 Apparent nominal output power at 25 C (kva) 176 220 330 440 550 Input Nominal primary mains input voltage/voltage range (V)* Nominal bypass input voltage/voltage tolerance (V) Nominal input frequency/frequency tolerance (Hz) 400 (250 to 460), three phase + neutral 400 ± 10% (380 V, 415 V selectable) three phase + neutral 50 ± 10% (60 Hz selectable) Input current distortion (THDi) (%) <3 Primary input Power Factor >0.99 Output Nominal output voltage (V) Output voltage stability by load variation 0-100% (%) - static - dynamic Nominal output frequency (Hz) Output frequency variation (%) - with mains synchronization - with own reference 400 (380 V, 415 V selectable) three phase + neutral ± 1 Complies with IEC/EN 62040-3, Class 1 50 (60 Hz selectable) ± 1 (2, 3, 4 selectable) ± 0.1 Inverter overload capacity Compatibility with loads 125% for 10 min., 150% for 1 min. Any power factor (leading or lagging) up to 1 without output derating; crest factor up to 3:1 Automatic adjustment of nominal power with temperature 110% at 25 C, 100% at 40 C General Classification according to IEC/EN 62040-3 VFI - SS - 111 Operating temperature ( C) 0-40 Relative humidity (without condensation at 20 C) <95% Protection level IP 20 Frame Color RAL 7016 Noise at 1 m (dba)* 67 67 69 70 71 / efficiency (%)* up to 98% Parallel configuration up to 8 units Dimensions And Weight Height (mm) 1780 Width (mm) 975 975 1675 1675 1900 Depth (mm) 858 UPS weight (kg) 550 632 1035 1190 1430 * Conditions apply 13

Chloride 80-NET Main Static Switch (MSS) Specifications MSS Technical Specification Electrical Data 1000A 2000A 3000A 4000A 5000A Nominal current (A) 1000 2000 3000 4000 5000 Power @380V (kva) 658 1316 1975 2633 3291 Power @400V (kva) 693 1386 2078 2771 3464 Power @415V (kva) 719 1437 2156 2875 3594 Nominal voltage (selectable) (V) 400 (380/415) Nominal frequency (selectable) (Hz) 50 (60) Voltage range (selectable) (%) ± 10 (± 15) Freqeuncy range (selectable)(%) ±1 (2, 3, 4 selectable) Maximum operating voltage range (V) 350-460 Maximum overload capacity for 10min (%) for 1min (%) for 600ms (%) for 100ms (%) 125 150 500 700 125 150 500 700 125 150 500 700 125 150 500 700 125 150 500 700 SCR I 2 t @ Tvj= 125 C; 8,3-10ms (A 2 s) 4,5*10 6 16,2*10 6 16,2*10 6 36*10 6 36*10 6 I tsm @ Tvj=125 C; 10ms (ka) 30 57 57 85 85 Withstand rating (4) (karms) 50 50 50 85 85 ECO mode Efficiency (%) >98 Transfer time when in synchro Inverter to reserve (ms) Reserve to inverter (ms) Transfer time without synchro (ms) <0.5 (no break) <0.5 (no break) <20 (selectable 0 to 20 ms) Retransfer delay (s) 5 System Data Noise @ 1 metre as per ISO 3746 (dba ± 2dBA) 64 70 Protection degree with open door IP 20 Mechanical dimensions: - Height (mm) - Width (mm) - Depth (mm) 1780 1025 848 (2) 1780 2422 (1200 (1) ) 848 (2) Weight (kg) 345 835 (571 (1) ) 1117 (827 (1) ) Switches Not included Floor area (m 2 ) 0.87 2,05 (1,03 (1) ) Floor loading (kg/m 2 ) 397 407 545 Cable entry Top / Bottom Top / Bottom (3) Access Ventilation Front and Top Forced Ventilation (air flow front/bottom to top) Air flow (when SCR are ON only) (m 3 /h) 1130 5000 Frame color (RAL scale) 7016 Environmental Data Operating Temperature ( C) 0-40 Maximum relative humidity @ 20 C (non condensing) (%) Up to 95% Max altitude above sea level without derating (m) 1000 m (for higher altitudes complies with IEC/EN 62040-3) Note: (1) Central MSS cabinet only. (2) Including handle (3) Top and bottom cable entry through TCE cabinets (4) With optional fuses 14

More than 35,000 organizations in 70 countries depend on our expertise. Today s successful businesses depend on adaptable technologies to help them respond quickly to market demands. Your data center must be built on a support infrastructure designed to match the power and cooling needs of rapidly changing IT initiatives such as virtualization and consolidation. Each IT change, move or addition will affect the entire support infrastructure so you need products and support that ensure your IT systems will operate reliably in these environments. 15

Ensuring The High Availability Of Mission-Critical Data And Applications. About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), is the world s leading provider of critical infrastructure technologies and life cycle services for information and communications technology systems. With an expansive portfolio of intelligent, rapidly deployable hardware and software solutions for power, thermal and infrastructure management, Emerson Network Power enables efficient, highly-available networks. Learn more at www.emersonnetworkpower.eu Locations Emerson Network Power Global Headquarters 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229, USA Tel: +1 614 8880246 Emerson Network Power Power EMEA Via Fornace, 30 40023 Castel Guelfo (BO) Italy Tel: +39 0542 632 111 Fax: +39 0542 632 120 power.networkpower.emea@emerson.com Emerson Network Power United Kingdom George Curl Way Southampton SO18 2RY, UK Tel: +44 (0)23 8061 0311 Fax: +44 (0)23 8061 0852 While every precaution has been taken to ensure accuracy and completeness herein, Emerson assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice. MKA4L0UK80NET Rev.4-08/2015 Globe Park Fourth Avenue Marlow Bucks SL7 1YG Tel: +44 1628 403200 Fax: +44 1628 403203 UK.Enquiries@Emerson.com EmersonNetworkPower.eu Follow us on Social Media: Emerson. Consider it Solved, LIFE, Trellis, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. or one of its affiliated companies 2015 Emerson Electric Co. All rights reserved.