Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes



Similar documents
Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Chloride 80-NET from 60 to 500 kw. Secure Power for Mission Critical Applications

Liebert NXC from 10 to 200 kva

Liebert 80-eXL from 100 to 1200 kw. Enhanced Design and Improved Efficiency

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

Advantages and Efficient Use of Programmable Sockets. By Miguel Rascon AC Power Senior Product Manager

Trinergy Cube from 300 kw to 3 MW. Beyond the Power Revolution

Uninterruptible Power Supply Product Regulations and Standardization in the European Union. By Matteo Tricarico Patents and Regulatory Engineer

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

4.0 UPS dedicated to ICT for unmatched energy savings

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

Eaton 93PM UPS Where aesthetics meet intelligence.

How To Make A Data Center More Efficient

Phase Modular Finally the benefits of Modular ups are for all

Power protection for data centers

Galaxy VM. Three-phase power protection. schneider-electric.com

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

PowerGem Pro Uninterruptible Power Supply

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Enterprise Remote Monitoring

Eaton 93PM UPS Efficient. Scalable. Innovative.

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

RIELLO ELETTRONICA. Master HP

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Eaton 93PM UPS Efficient. Scalable. Innovative.

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

ABB PSPS Erich Steinmann; Generator control-2013

Standardization and modularity as the foundation of data center UPS infrastructure

IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

The Trellis Dynamic Infrastructure Optimization Platform for Data Center Infrastructure Management (DCIM)

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling

CUSTOMER EXPERIENCE CENTER

Protect. UPS Solutions for large Data centers

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw

Panduit Infrastructure Management Software for Data Centers and Enterprises

UPS system for emergency lighting and smoke extraction

The Trellis Dynamic Infrastructure Optimization Platform for Data Center Infrastructure Management (DCIM)

IT White Paper. N + 1 Become Too Many + 1?

SG Series UPS kva three phase 400 Vac

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

POWER. Your Partners in Availability POWER

The Trellis Dynamic Infrastructure Optimization Platform

Liebert icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

Opportunity of Energy Saving in electrical path is lesser as compared to other areas

An Uninterruptible Power Supply Topology to Manage the Arrival of Big Data Kenny Green

ABB central inverters PVS to 1000 kw

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

GAMATRONIC ELECTRONIC INDUSTRIES LTD.

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Five Essential Components for Highly Reliable Data Centers

Physical Infrastructure Management Solutions

Product catalog ABB UPS products and solutions Power protection for critical infrastructures

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

TLE Series. Product Description kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES

Data centre experts. Advanced power protection for data centres

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Integrated Power Systems for Data Centers

Product brochure Eaton 93PS UPS 8-40 kw. More advanced. power. protection

LAP ENERGIA PARA DATACENTERS

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

Revolutionizing Data Center Infrastructure Management

Technical Specification Kohler PW 5000/TP

Using DCIM to Identify Data Center Efficiencies and Cost Savings. Chuck Kramer, RCDD, NTS

Increased power protection with parallel UPS configurations

GE Digital Energy. SG-CE Series UPS kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

DATA CENTER PHYSICAL INFRASTRUCTURE

SiteWeb Monitoring System. Real Time Power and Environment Monitoring Platform for Telecom Applications

Precision Cooling for Business-Critical Continuity. Liebert PCW. Cool the Cloud

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Smart Data Center Solutions

Cisco Nexus 7000 Series Power Supply Modules

Essential Power System Requirements for Next Generation Data Centers

Transcription:

Trinergy from 200 to 1600 kw High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative solutions for the benefit of its customers. Emerson Network Power protects and optimizes critical infrastructure for data centers, communications networks, healthcare and industrial facilities. Emerson Network Power s broad technology base and global expertise support a full spectrum of enterprise-wide solutions for today s vital business needs. Regardless of your size, you can t afford for your critical business systems to go down and you can t waste time recovering your IT infrastructure after a disruption. Leave that to us, the experts in grid to chip solutions, from the biggest to the smallest data centers, we are ready to serve your needs. More standardization, so you don t need further budget allocations to install it. More simplification so you don t need to be a specialist to get the best for your business. More support, so while you are enjoying doing business, we are protecting you. 2

3

Trinergy From 200 To 1600 kw 99% tracking mode transitioning An Industry First Trinergy s revolutionary architecture comes from incorporating the three industry standard functioning configurations for the first time in one high power UPS: Maximum Power Control (VFI) Maximum Energy Saving (VFD) Conditioning (VI) Trinergy s unique combination of technology allows it to monitor the environment and operating conditions of the network before intelligently selecting the functioning mode best suited to the line conditions. Trinergy s ability to choose the most efficient operating mode based on the different network conditions ensures that the supply to the load remains in optimum condition at all times. This allows the system to achieve extraordinary energy savings, first class performance and maximum power protection. 1 The high level of flexibility, energy efficiency and adaptability of Trinergy are in line with the European Union s Code of Conduct on Best Practices, thus further confirming its outstanding performance capabilities. Features And Performances Transformer free design Full IGBT double conversion technology Excellent input performances - PF > 0.99 - THDi < 3% Output Power Factor 1 Output Power Factor diagram symmetrical respect to zero Permanent 100% kva - no derating with any load (lagging or leading) Optimum space/power ratio Automatic output power upgrade up to +10% High conversion efficiency (certified up to 99%). 1) Class 1 (IEC 62040-3) CBEMA 4

Dynamic Functioning Modes Manual Bypass Static Bypass Power interface Rectifier Inverter Output Batteries Maximum Power Control (VFI) provides the highest level of power conditioning and protects the load from all electrical network disturbances. Manual Bypass Static Bypass Power interface Rectifier Inverter Output Batteries Maximum Energy Saving (VFD) detects when conditioning is not required and allows the energy flow to pass through the bypass line. Manual Bypass Static Bypass Power interface Rectifier Inverter Output Batteries Conditioning (VI) compensates the load THDi, PF and main sags and swells. Dynamic Modes 5

Minimized Total Cost Of Ownership Maximized Savings Trinergy s design features and outstanding efficiency up to 99%, greatly minimize the total cost of ownership from installation through to operation: of air conditioning system Delivering requirements Extraordinary Savings The modular architecture of the Trinergy UPS allows for great advantages in terms of installation: Reduced size of electrical infrastructure Reduced size of circuit protection devices Reduced cabling Trinergy features unitary input Power Factor and low content of harmonics providing full compatibility with gensets and greatly contributing to reduced installation and running costs. Running Cost Savings Circular redundancy Trinergy s circular redundancy feature adjusts available UPS capacity to meet immediate load requirements by automatically switching excess module capacity to standby, thus greatly improving efficiency at partial load and reducing operating costs. Air conditioning The extremely high efficiency achieved with Trinergy reduces the energy dissipated by the UPS (kw), thus minimizing the demand and consumption of the air conditioning system. 70 60 50 70 70 40 60 THDi 70 % 70 60 6030 50 60 50 20 40 THDi 50 % 50 40 40 30 1040 THDi % THDi THDi % % 20 30 30 030 20 10 25% 20 20 50% Load 75% 100% 0 10 10 10 25% 50% 75% 100% Load 0 Input 0Harmonic 0 Distortion vs Load Percentage 25% 1 25% 25% 50% 50% 75% 50% 75% 100% 75% 100% 100% Load Load Load 0.95 PF 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.9 1 0.85 0.95 PF 1 0.8 1 0.9 0.95 0.95 0.85 0.75 PF 0.9 0.7 0.9 0.8 0.85 0.85 PF PF0.65 0.75 0.8 0.8 0.6 0.7 0.75 0.75 0.65 25% 50% 75% 100% Load 0.7 0.7 0.6 0.65 0.65 25% 50% 75% 100% 0.6 0.6 Load 25% 25% 25% 50% 50% 75% 50% 75% 100% 75% 100% 100% Load Load Load Input Power Factor vs Load Percentage 100 98 96 94 92 % 90 88 86 84 82 80 0% 20% 40% 60% 80% 100% Load 95-99% efficiency at down to 20% load 100 90 80 70 60 kw 50 40 30 20 10 0 Trinergy Six Pulse Six Pulse + Filter 92% 93% 94% 95% 96% 97% 98% 99% Efficiency Air conditioning size & power reduced by 400% 6

High Efficiency Trinergy and technology have been Able to discriminate between the different network input conditions and select the best functioning mode in relation to the disturbance, Trinergy can achieve maximum energy savings by using only the necessary amount of energy required to provide the best output power quality and conditioning to the load. Premium energy savings via transformer free technology and Trinergy s algorithm Quietest UPS in its power range Maximized battery life with Advanced Battery Care (ABC) Circular redundancy 7

Sizing Your System Vertical modularity Service a 200 kw module while the UPS system continues to protect your load. I/O Box Major interface for connectivity and power connections. Horizontal modularity Up to 1600 kw with additional 200 kw modules. Orthogonal modularity Up to 8 units in parallel. the stacked drawers in each module can be individually extracted for service purposes while the UPS system continues to protect your load. Trinergy can scale up to 1.6 MW in power by adding complete 200 kw UPS modules side-by-side and around the input/output power section. is the ability of Trinergy to work with up to 8 complete UPS (fully populated with UPS modules) in parallel. 8

Three Dimensional Modularity Trinergy s three dimensions of modularity allow businesses to expand their power protection needs at the same pace as their evolving load requirements by simply adding additional power modules. These three dimensions of modularity are built around Trinergy s I/O Box which is the major interface for connectivity and power connections as well as centralized and distributed battery configurations. Modules can be added at anytime during the lifecycle of the UPS available in one UPS. 3 Dimensional Modularity 9

Servicing Critical Infrastructure Proactive equipment maintenance reduces downtime and extends equipment life which in turn maximizes return on investment and increases system availability. Emerson Network Power supports entire critical infrastructures with an extensive service offering, guaranteeing network availability and total peace of mind 24/7. Our approach to servicing critical infrastructure covers all aspects of availability and performance, from single units to entire mission critical systems, providing customers with tailored services to meet their individual business needs and further guaranteeing critical continuity. Emerson Network Power s service program is designed to ensure that your critical power protection system is maintained in an optimum state of readiness at all times. The LIFE remote monitoring and diagnostic service provides early warning of UPS conditions and out of tolerances. This allows effective proactive maintenance, fast incident response and remote trouble shooting, giving customers complete security and peace of mind. Maximize Availability Regular preventive maintenance increases uptime. Emerson Network Power s LIFE provides early warning of operating anomalies allowing real-time diagnosis and swift identification and resolution. Minimize Downtime Should an emergency condition arise, an engineer in the 24/7 manned LIFE service center carries out an immediate fault analysis and instigates appropriate corrective action. Through comprehensive data collection and analysis, LIFE s detailed reporting system provides valuable information on power and equipment trends, over any selected period of time. Connectivity And Tracking Real-time connectivity, tracking and LIFE remote diagnosis ensure that your system is closely monitored 24 hours a day. LCD Touch Screen Features High security access with separate password levels for users and service engineers User-friendly graphical interface Single-line mimic diagram showing system status Contemporary dashboard-style indicators for major system values and conditions Automatic charting display for logged power and environmental data Information Tracking Overall system and module readiness Module level alerts for all major subsystems including rectifier, inverter, batteries, static switch and bypass System voltages and power Load vs. capacity indicator LIFE Diagnostics 10

System temperature gauge Battery charge indicator Service history logs Hardware Connectivity The touch screen display ensures the monitoring and control of networked UPS, through two different options of the TCP/IP protocol: The integration of UPS with Building Monitoring and Automation Systems via MODBUS RTU, MODBUS/TCP or JBUS protocols The integration of UPS in Network Management Systems through SNMP protocol Software Connectivity Liebert Nform will monitor the UPS via SNMP protocol. Authenticated alarm management, trend analysis and event notification delivers a comprehensive monitoring solution. Available in a variety of versions to suit anything from small computer rooms to multiple location distributed IT networks, Liebert Nform enables: Condition based system state recording Alarm event exporting to disk SMTP email Execution of external program Shut down clients Trellis Platform Emerson Network Power s Trellis platform is a real-time infrastructure optimization platform that enables the unified management of data centre IT and facilities infrastructure. The Trellis platform software can manage capacity, track inventory, plan changes, visualize configurations, analyze and calculate energy usage, and optimize cooling and power equipment as well as enable for virtualization. The Trellis platform monitors the data center, providing a thorough understanding of system dependencies to help IT and facilities organizations keep the data center running at peak performance. This unified and complete solution, delivers the power to see the real situation in your data center, make the right decision and take action with confidence. System status, measurements and single-line diagram. 11

In The Field availability. Input/output connections Three phases of inverter CAD - Trinergy internal architecture Three phases of rectifier I/O Box Static bypass Battery connection Booster Faster Installation And Service Trinergy s modular design facilitates installation by allowing the UPS to be assembled on-site, module-by-module, making it ideal even for sites with difficult accessibility. Trinergy can be configured to suit immediate load requirements as additional modules can easily be added/removed to respond to changing load demands. This feature minimizes initial capital investment and ensures that the UPS system operates at a significant percentage load in order to ensure optimum system efficiency. Accessibility Modules are easily accessible from the front of each cabinet, allowing simplified service and maintenance to be carried out. 12

Serviceability Concurrent Maintainability Allows single modules to be serviced while the remaining modules continue to supply power to the load. Internal Redundancy The system is configured so that any individual unit can be easily isolated for safe maintenance whilst the remaining modules continue to provide conditioned power to the load. High Reliability (MTBF) Is achieved through the possibility of adding internal redundancy to the system. This can be based on a common battery bank for the whole system, or using distributed batteries i.e. a battery bank for each 200 kw UPS module. MTTR) The multi-module concept that enables a user to define the level of redundancy required ensures a reduced Mean Time To Repair (MTTR) of individual UPS modules. Trinergy s proven reliability and simplified maintainability guarantee uninterrupted availability of power for critical loads. Serviceability 13

Trinergy Specifications Technical Characteristics Rating 400 800 1000 1200 1400 400 600 800 1000 1200 1400 1600 400 600 800 1000 1200 1400 1600 440 660 880 1100 1320 1400 1760 200 400 600 800 1000 1200 1400 400 (250 to 460), three phase + neutral 400 ± 10% (380 V, 415 V selectable) three phase + neutral 45-65 Hz <3 >0.99 - static - dynamic - with mains synchronization - with internal reference 400 (380 V, 415 V selectable) three phase + neutral ± 1 Complies with IEC/EN 62040-3, Class 1 50 (60 Hz selectable) ± 1 (2, 3, 4 selectable) ± 0.1 125% for 10 min., 150% for 1 min. Any power factor (leading or lagging) up to 1 without output derating; crest factor up to 3:1 110% at 25 C, 100% at 40 C General VFI - SS - 111 0-40 <95% Protection level IP 20 Frame colour RAL 5004 71 73 74 75 76 77 78 technology up to 99% up to 8 UPS* = Max 9.6 MW Height (mm) 1780 1800 2775 3450 4450 5125 6900 7600 860 860 860 860 860 880 880 UPS weight (kg) 1450 2370 3040 3890 4560 5100 5700 * Conditions apply 14

More than 35,000 organizations in 70 countries depend on our expertise. Today s successful businesses depend on adaptable technologies to help them respond quickly to market demands. Your data center must be built on a support infrastructure designed to match the power and cooling needs of rapidly changing IT initiatives such as virtualization and consolidation. Each IT change, move or addition will affect the entire support infrastructure so you need products and support that ensure your IT systems will operate reliably in these environments.

Ensuring The High Availability Of Mission-Critical Data And Applications. About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), delivers software, hardware and services that maximize availability, capacity and efficiency for data centers, healthcare and industrial facilities. A trusted industry leader in smart infrastructure technologies, Emerson Network Power provides innovative data center infrastructure management solutions that bridge the gap between IT and facility management and deliver efficiency and uncompromised availability regardless of capacity demands. Our solutions are supported globally by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at www.emersonnetworkpower.eu Locations Emerson Network Power Global Headquarters 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229, USA Tel: +1 614 8880246 Emerson Network Power AC Power EMEA Via Fornace, 30 40023 Castel Guelfo (BO) Italy Tel: +39 0542 632 111 Fax: +39 0542 632 120 ACpower.Networkpower.Emea@Emerson.com Emerson Network Power United Kingdom George Curl Way Southampton SO18 2RY, UK Tel: +44 (0)23 8061 0311 Fax: +44 (0)23 8061 0852 While every precaution has been taken to ensure accuracy and completeness herein, Emerson assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice. MKA4L0UKTRIN Rev.4-09/2013 Globe Park Fourth Avenue Marlow Bucks SL7 1YG Tel: +44 1628 403200 Fax: +44 1628 403203 UK.Enquiries@Emerson.com EmersonNetworkPower.eu 2013 Emerson Electric Co. All rights reserved.