Multi-Cyclone Dust Collectors



Similar documents
Chapter 3.5: Fans and Blowers

ENGINEERING DATA. Fan Performance Troubleshooting Guide

product application guide

Efficiency on a large scale CFB Steam Boilers

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

SEPARATING DUST PARTICLES USING AN AERODYNAMIC DEDUSTER

Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance

Pipe Cutting and Beveling Clamshells

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

Manual piston sampler...m 11

TABLE OF CONTENT

Basic Selection & Proper Application of Overhead Air Distribution Devices

Air Conditioning Clinic

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

TYPE E Main Valve Sizes 3 /8 through 12

SFI SPECIFICATION 61.1 EFFECTIVE: FEBRUARY 26, 2014

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Element D Services Heating, Ventilating, and Air Conditioning

Fan Applications. Major Considerations Defined. Fan Application. Major Application Considerations. A. Fan Types FA/126-06

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

Centrifugal Fans and Pumps are sized to meet the maximum

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

FLSmidth ball mill for cement grinding

Fuller-Kinyon Pump: Dry Material Line Charger

ROOF TOP MOUNTED Air Handler Specification

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes. Accurate airflow measurement for demanding applications

AABC Specifications for Testing and Balancing HVAC Systems

RPV - RP - RA air handling units

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Gas-Fired, Residential Storage Type Water Heaters

TOP 10 NOISE CONTROL TECHNIQUES

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Boiler Plan II Table of Contents

Machine Design II Prof. K.Gopinath & Prof. M.M.Mayuram. Module 2 - GEARS. Lecture 17 DESIGN OF GEARBOX

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Selecting TEMA Type Heat Exchangers

AMD-33 Air Measuring Station with VCD-33 Control Damper

2367 LAKESIDE DRIVE, SUITE A-1 BIRMINGHAM, AL PHONE (205) FACSIMILE (205)

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

Goulds AF. Axial Flow Pump

Particulate Matter Emissions-Control Options for Wood Boiler Systems

VERTICAL TURBINE AND PROPELLER PUMPS

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Unit 24: Applications of Pneumatics and Hydraulics

Pump Division MNR MND. Absorber Recirculation Pumps. Bulletin PS (E)

Air Eliminators and Combination Air Eliminators Strainers

Testing Capabilities. Worldwide Designers & Manufacturers of Air Moving Equipment

Daniel Venturi Tubes and Flow Nozzles Brochure

SPECIAL APPLICATIONS

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Packaged Terminal Air Conditioner Wall Sleeve Installation

FIX TURE CARRI ERS. 140(a) MPB-2011-USA

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Field Service and Replacement Parts for Air Cooled Heat Exchangers

IMPROVING ENERGY EFFICIENCY IN CEMENT PLANTS

PART 1 GENERAL 1.1 SECTION INCLUDES

AURORA AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES

Chapter 12 Industrial Ventilation

For New Technology Network. Steel Manufacturing Machinery Product Guide Book

PFT Two stage axial fan The high pressure fan for modern boiler plants

National System of Garage Ventilation s Engineering Guide

Chemical Fume Hoods. Environmental Health and Safety

FAN ENGINEERING. ( ) ρ N. Fan Performance Troubleshooting Guide

Cooktop Low-Profile Ventilation Hoods

CCI 100 DPC DRAG Wellhead Production Choke Valve

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

AESCO/MADSEN. Self-Erect Silos by AESCO/MADSEN

Pneumatic Tires. Specialist Tires for Maximum Efficiency

Downflo workstation DuSt ColleCtorS

API Flanged Safety Relief Valves Series 526 CATALOG

5. FANS AND BLOWERS. 5.1 Introduction. 5.2 Fan Types

FUNDAMENTALS OF GAS TURBINE ENGINES

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

OilonChooser Operating Instructions

Tube Type Oil Skimmer Comparison

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB

EMERGENCY VAPOR SCRUBBER SYSTEMS

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Technical Information

Liquid Flowmeters A Guide for Selecting a Flowmeter for Pressurized Systems

Diagnostics for Mobile Homes: HVAC

300 Series PA Pump and Cooler Assemblies

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

PIPING DRAWINGS BASICS N.P.TODKAR

OHV / OHVL Type OH3 Vertical Inline Pumps ISO (API 610)

ASX7-4-IOM-7 J

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Transcription:

Multi-Cyclone Dust Collectors

Clarage Half a Century of Design and Experience Designed and Fabricated to Meet Customer Needs Clarage Multi-Cyclone Mechanical CollectorS Experience makes the difference. Clarage has been in business since 1874, dedicated to the design and fabrication of fans since 1912 and mechanical multi-cyclone dust collectors since 1940. When Clarage collectors were first introduced, it was under the name of the Fly Ash Arrestor Corporation. In the late 1960 s, the name changed to Zurn Air Systems Division, and in 1997 our current name, Clarage was introduced. Although the name has changed, Clarage still manufactures mechanical collector equipment that has established one of the best known and widely respected reputations in the world. There are thousands of Clarage collectors installed in the United States and around the world. Clarage's experience, capability, and extensive installation list has been built up over decades of dedication and resourcefulness. Practical uses for Clarage collectors range from helping a system meet its required air quality emission levels, to extending the life of the system ID Fan and connecting ductwork. Specific applications Clarage has supplied collectors for include: Oil Rockwool Bagasse Lime dust Glass beads Sludge Coke calciner Sulfur dust Sinter dust Feldspar Clinker cooler dust Iron ore pellets/dust Kalor dust Rice hulls Petroleum coke Sulfite Wood waste/bark (various types) Coal (various types) Miscellaneous refuse Unmatched experience along with flexible engineering and the capability of altering conventional designs to meet specific customer needs, makes Clarage the best choice for mechanical collectors.

Clarage Collectors The Multi-Cyclone Mechanical Collector A collector consists of a housing containing a quantity of collecting tube assemblies, each an individual centrifugal dust collector. As illustrated, dust laden gas enters the top of the collecting tube through the inlet guide vanes. These vanes impart a smooth, fast spiral to the gas, setting up a highly centrifugal action with a minimum of turbulence and erosion. As the gas descends in a cyclonic pattern, the dust is forced by centrifugal action against the wall of the collecting tube and gravitates to the bottom where it is discharged through the dust discharge boot. A vortex forms at the bottom of the collecting tube and the cleaned gas makes an inner whirl up into the outlet tube. Optional outlet recovery vanes help straighten the gas flow to reduce draft loss. Careful attention to housing design details such as inlet and outlet proportions, collecting tube spacing, and dust discharge boot design assures uniform gas distribution and proper flow to each individual collecting tube for maximum design efficiency. Tube Diameters and Efficiency Clarage collectors are available with 6", 9" and 11.5" diameter collection tubes. Theoretically, high-collection efficiencies are achieved with the smaller 6" or 9" diameter tubes, since the centrifugal force applied to the dust particles increases as the tube diameter decreases. Three other major design factors also significantly affect collection efficiency, namely proper gas distribution, draft loss, and particle size/specific gravity. Clarage engineering is available for assistance in determining tube size. Standard (STD) and Totally Accessible (TA) Mechanical Collectors Clarage collectors are designed and fabricated to meet the customers needs. The two types available are Standard (STD) and Totally Accessible (TA). The collecting tube assemblies for both the STD and the TA collectors are identical. The differences between the STD and the TA collector are in the design of the housings and outlet tubes. Operation of collecting tube assembly.

Standard Design Collector The STD design collector is most commonly used in smaller industrial applications. The greatest advantage of the STD collector is its compact design that can easily accommodate space limitations. Additional advantages of the STD collector design can be realized through cost reduction in insulation and lagging area, as well as a smaller support structure. Standard Design Collector when space is a premium. Totally Accessible Design Collector when total access is required. Standard Collector Features: Available in Three Tube Sizes Collecting tubes in 6", 9" and 11.5" diameters available to meet individual requirements. Heavy-Duty Construction All components are designed for rugged service by an experienced collector team totally familiar with collector operation. Each application is individually evaluated based on the severity of service and previous field experience. Completely Shop-Assembled All collectors are custom-fabricated and completely assembled to the extent practical for shipment. This results in minimum erection man-hours and handling at the installation site. Cast Collecting Tubes Special cast tubes give uniform wall thickness and maximum Brinell hardness for prolonged service-life. The mounting flange at the top of the collecting tube is an integral part of the casting. Four studs provide secure, gas-tight mounting. Replaceable Dust Discharge Boots Sturdy cast iron boots are at the base of the collecting tubes where the greatest wear occurs. Each boot bolts in place for quick, economical replacement compared to more costly tube designs which utilize an integral tube bottom. Access Doors This feature is constructed of heavy duty cast iron with quick open design, that requires no special tools to open. These doors can be located in any direction. Special configuration such as our Double-Doors can be incorporated at the customers request. Warning signs and safety chains are always standard components of Clarage Collector Access Doors.

Clarage Collectors Totally Accessible Design Collector The TA collector offers three basic differences to conventional standard collector designs. These result in significant improvements in collector wearresistance and maintenance. These differences are: Grouped collecting tubes with inlet access corridors Separate outlet plenums for tube groupings Equal length outlet tubes The inlet access is such that every tube is within easy reach and view. Normal design provides that no tube is more than one tube away from the access corridor, making it totally accessible. Totally Accessible Collector Features: Totally Accessible Collectors have all of the features of the Standard Collector, and the following additional features: Totally Accessible The accessibility is available through access doors provided at both inlet and outlet locations for inspection, cleaning and maintenance as required. Lower Velocities Lower velocities significantly reduce the wear of the tube assembly components. Entering gases/particulate utilize the access corridors, therefore do not cause abrasion while passing through the array of gas outlet tubes, which is common to conventional collectors. Flexible Arrangement TA collectors, with no inlet static pressure differential, make long and narrow arrangements possible for substantial duct savings. The unique TA design also allows flexibility in inlet and outlet arrangements. Elimination of Hopper Recirculation The TA collector does not have differential pressure in the hopper, thereby eliminating the problem of hopper recirculation. Balance Flow To All Tubes The plenum hooded design eliminates obstruction in the gas stream as the gas travels through the collector assembly. This non-obstructive feature allows for no inlet static pressure differential, and provides low-velocity/low-pressure drop gas flow to every tube. Optional STD and TA Design Features Hopper Evacuation Systems Inlet/Outlet Arrangements Damper Control for Increased Collector Flexibility Sectionalizing By-Pass Isolation

Clarage (6) OUTLET TUBE (Constant length for Totally Accessible Collectors; variable length for Standard Collectors) (3) SEAL (Airtight) (5) INLET GUIDE VANES (8) BOOT STRAP (7) DUST DISCHARGE BOOT Cut-away View of the Inlet Tube Assembly (10) TOP TUBE SHEET (Sloped in Standard Collectors) (2) BOTTOM TUBE SHEET (4) STUD (9) OPTIONAL OUTLET RECOVERY VANES (1) CAST INLET COLLECTING TUBE Your Single source for all collector replacement parts Clarage s expertise certainly does not end with the design and fabrication of our own collectors. One Clarage's greatest strengths has been, and continues to be, the ability to repair, modify, or replace other manufacturer s collectors. Replacing obsolete equipment produced by companies like Western, Joy, UOP, etc. is routine and common practice at Clarage. Engineering flexibility, in most cases, allows Clarage to match existing collector dimensions exactly. This results in lower replacement costs, through fewer modifications to the surrounding structures. Even when only replacement tubes are required, Clarage is the logical choice. Most competitor tube assembly designs (obsolete and current), can be easily substituted with one of Clarage s available tube sizes. Over the years, the 9" inlet tube has become the most universally used tube size for Mechanical Collectors. Clarage offers this size, and is able to adapt it to any collector design which uses the 9" tube. This ability, along with an always adequately stocked supply of collector parts, makes Clarage the best choice. Whether it s a single part or the entire unit, Clarage has your mechanical collector replacement part needs covered. Cast Inlet Collecting Tubes With Integral Mounting Flange Clarage collecting tubes (1) are constructed of cast iron with an alloy additive to yield a higher Brinell hardness. A mounting flange is cast at the top of the collecting tube, which holds the entire assembly to the bottom tube sheet (2). A permanent airtight seal (high temp. gasket) (3) is required to prevent gas from escaping around the tube directly into the hopper. A 3/8-inch lip extends above the integral flange to extend through the tube sheet into the inlet. The flange is sealed to the tube sheet with four studs (4) to retain the initial tight-seal even under severe service.

Clarage Collectors Inlet Guide Vanes The inlet guide vanes (5) are separately cast and are held in place by support on the gas outlet tube (6). They fit securely in place inside the collecting tube keeping the outlet tube centered. Inlet guide vanes are designed to give the gas maximum centrifugal action on its spiraling path down the tube toward the dust discharge boot (7). Inlet guide vanes are replaceable by splitting them in half. Each vane has two notches for this purpose. Dust Discharge Boot The cast-iron dust discharge boot is retained at the lower end of the collecting tube by two boot straps (8). The boot straps in turn are bolted in place at the top of the collecting tube with two of the studs used to connect the assembly to the bottom tube sheets. Since the boot is subject to the greatest wear, it has been designed for easy replacement. This design allows greater cost savings than replacement of the entire collecting tube, as with competitive designs having the boot and tube as an integral assembly. The dust discharge boot has three peripheral slots where collected dust is discharged by inertial and centrifugal force out of the tube, immediately prior to the vortex reversal of the gas at the tube bottom. Outlet Recovery Vanes Recovery vanes (9) are used at the lower end of the gas outlet tube in certain applications. These vanes are used to recover the rotational energy of the exiting gas, thereby increasing the total capacity of each collecting tube. Recovery vanes are not recommended where the incoming gas has a characteristic, such as heavy oil or bark-fired combinations. Outlet recovery vanes have the efficiency benefits of permitting a smaller collector for a given gas flow. Outlet Tubes Outlet tubes are held in place at the lower end by the inlet guide vane and welded at the top to the top tube sheet (10). Their purpose is to deliver the cleaned gas from the collecting tubes to the outlet chamber. The abrasive gases on the outside of these tubes cause greater wear than from the inside. Both steel and high- Brinell cast outlet tubes are available. The unique design of the discharge boot means low cost replacement with improved operating efficiency. Example of STD Type collector modified to incorporate TA Type structural supports, and angle iron wear shields on the front row of outlet tubes.

Clarage Products and Services Standard Centrifugal Fans Backward Curved Backward Inclined Pressure Blower Industrial Exhauster Radial/ Paddle Wheel Cast Iron Exhauster Custom Centrifugal Fans Airfoil Backward Curved Backward Inclined Radial Tip Straight Radial Forward Curved Hi-Boost 2-Stage Pressure Blowers All Drive Arrangements SWSI and DWDI Selections Inlet Boxes Sleeve or Anti-friction Bearings Axial Fans Jet Fans Tubeaxial Vaneaxial Fixed Pitch Adjustable Pitch In Motion Adjustable Pitch At Rest Multi-Cyclone Dust Collectors 6", 9" and 11.5" Tube Availability Standard (STD) and Totally (TA) Accessible Designs Services Repair and Rebuild Field Service Upgrade Engineering Performance Material Construction Quality Fabrication Erection and Start-up Supervision Testing Services Turnkey Services Volume Control Dampers High Temperature Fans Special Materials 5030 - June 2003 5959 Trenton Lane Minneapolis, MN 55442 24-Hour Emergency Service Hotline 800-598-9234 Phone 763-551-7600 Fax 763-551-7601 www.clarage.com sales@clarage.com ISO 9001 CERTIFIED