60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS



Similar documents
5W LED Energy Saver PIR Bulkhead

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

PIR Motion Detector INSTALLER GUIDE E-700. SF-SA-140 -B.qxd 16/05/ :19 Page 1

PIR Motion Detector INSTALLER GUIDE E-806. SF-SA-360-CS-W.qxd 12/04/ :34 Page 1

PIR Motion Detector E-808

60W Security Twinspot. 754HB2/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

OPERATING INSTRUCTIONS

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

LED MOTION ACTIVATED FLOOD LIGHT

LED MOTION ACTIVATED FLOOD LIGHT

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

Fused Spur Time Switch

LED Security Spotlight User Manual

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

LOS 2500 SUPER CEILING SENSOR. Installation Manual

EBDSPIR-PRM, EBDSPIR-PRM-IP

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Infrarot-Bewegungsmelder IP44

Die-Cast Metal, Motion- Activated Post Light

Wireless 7 Day Programmable Room Thermostat

Passive Infrared Motion Detector 5420/90. Installation Instructions

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

INFRARED QUARTZ WALL HEATER

Operating instructions IV / 2007

FIRERAY 2000 Installation Guide

ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Installation Instructions

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Awning Instructions. Full Cassette 1.5m to 6m

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Floodlight Range Installation Guide

Drayton Digistat +2RF/+3RF

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

Operating instructions II / 2004

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

EBDSPIR-DD, EBDSPIR-DD-IP

Product and functional description

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

Operating Instructions. Room temperature controller

V94 BULK TAPE DEGAUSSER

High definition day/night

Operating Instructions Bedienungsanleitung Mode d emploi

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Radiant Temperature Sensor TY7321

Portable Air Conditioner

Installation Manual. The STEALTH 360 is the most reliable and technically advanced motionactivated

Meaco 30L and Meaco 40L dehumidifier instruction manual

BATTERY OPERATED LED MOTION SENSOR LIGHT MODEL #GU8002-LED-DC

Busch-Watchdog Presence EIB Type:

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

TIG INVERTER INSTRUCTION MANUAL

Wireless Home Security Alarm System AM 500

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

REDWALL-V adjustment procedures guide

Cross-beam scanning system to detect slim objects. 100 mm in

SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

in a new light. Occupancy sensors and sensor lights. Sleek new styling and more features than ever before.

Triac Printed Circuit Board Replacement

Lighting Management solutions

LUCCI AIRFUSION QUEST II CEILING FAN

Product Catalogue August Energy management Switches and controls

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

H45 LED - Direct and indirect pendant

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

3 IN 1 BATHROOM HEATER

User's Instructions. Alpha HE CB25/33 and HE SY25

Power Socket (2 Gang)

Duct Humidity Transmitter

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

6x 54w SuperZoo T5 HIGH FREQUENCY ELECTRONIC CONTROLLER LUMINAIRE

Wiper Motor Marinco 2.5. Installation Instructions

6 LED colours: White Blue Green Red Yellow Amber

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

Dual Technology Ceiling Mount Sensor

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

GB/DAS User Instruction

Medical Lighting. XL4 Patient Light

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Xenon HID Lighting System

ORLAND FOLLOW PR-1211

INSTALLATION INSTRUCTIONS

HERZ-Thermal Actuators

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

Transcription:

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

SLB88 PIR BULKHEAD LIGHT - BLACK WEATHERPROOF LAMP TYPE IP44 60w ES MAXIMUM PIR SWITCHING 500w MAXIMUM TIME ON DETECTION ANGLE 5sec 5min 110 DUSK TO DAWN DETECTION RANGE 8m 3 YEAR GUARANTEE In the unlikely event of this product becoming faulty due to defective material or manufacture, within 3 years of the date of purchase, please return it to your supplier with proof of purchase and it will be replaced free of charge. Should you encounter any difficulty please contact our helpline on 020 8450 0515.

SLW89 PIR BULKHEAD LIGHT - WHITE WEATHERPROOF LAMP TYPE IP44 60w ES MAXIMUM PIR SWITCHING 500w MAXIMUM TIME ON DETECTION ANGLE 5sec 5min 110 DUSK TO DAWN DETECTION RANGE 8m 3 YEAR GUARANTEE In the unlikely event of this product becoming faulty due to defective material or manufacture, within 3 years of the date of purchase, please return it to your supplier with proof of purchase and it will be replaced free of charge. Should you encounter any difficulty please contact our helpline on 020 8450 0515.

SECTION ONE GENERAL INFORMATION The unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the lamp will illuminate for a user-determined time period. An integral daylight sensor ensures night-only operation. PARTS INCLUDED - Luminaire c/w PIR Sensor unit. - Instruction manual. Please keep safe for future reference. - Accessory Pack. TOOLS & PARTS NEEDED - Electric/hand-held drill & bits. - Terminal or Electricians screwdriver - Large slotted/philips screwdriver - Wire cutters Unit is for outdoor use only. Unit must be mounted on a non-flammable surface as a fixed luminaire, and is not suitable for portable use. The unit can get very hot during use. Ensure the unit has cooled before handling. Ensure adequate ventilation space is allowed between the unit and any object above, in front or to either side of the unit. Suggested space is 0.5m above, 0.3m to either side & 1.0m in front. If in any doubt, consult a qualified tradesperson or electrician. DO NOT USE THIS PRODUCT WITH COMPACT FLUORESCENT ENERGY SAVING LAMPS. SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones, at various vertical and horizontal angles as shown (see diagram A). A moving human body needs to cross/enter one of these zones to activate the sensor. The best all-round coverage is achieved with the unit mounted at the optimum height of 1.8m. Careful positioning of the sensor will be required to ensure optimum performance. See diagram A detailing detection range and direction. The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS (see diagram B). Therefore position the unit so that the sensor looks ACROSS the likely approach path. Avoid positioning the sensor where there are any sources of heat in the detection area (extractor fans, tumble dryer exhausts etc.). Reflective surfaces (ie pools of water or white-painted walls) and overhanging branches may cause false activation under extreme conditions. During extreme weather conditions the motion sensor may exhibit unusual behaviour. This does not indicate a fault with the sensor. Once normal weather conditions return, the sensor will resume normal operation.

SECTION THREE INSTALLATION After choosing a suitable location (see previous section) install the unit as follows: The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that 3-core round flexible cable of 1mm 2 gauge is used. A isolating switch should be installed to switch the power to the unit ON & OFF. This allows the sensor to be easily switched off when not required or for maintenance purposes. *** IMPORTANT *** Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. Remove the diffuser using a terminal screwdriver to release the clips on both sides (diagram E). Remove the connection cover (diagram F) Ensure the unit is in an upright position with the sensor module at the bottom. Mark the position of the fitting holes. Drill the holes. Insert the rawl plugs into the holes. PIERCE & PASS THE CABLE THROUGH THE GROMMET BEFORE PROCEEDING. Attach the mounting plate to the wall using suitable screws. Do not overtighten the mounting screws as this could damage the mounting plate. If using a power screwdriver, use the lowest torque setting. CONNECTION Pass the mains supply cable around the back of the lampholder for ease of wiring. Connect the cable to the terminal block on the unit as follows (see connection diagram): NEUTRAL (Blue) EARTH (Green/Yellow) LIVE (Brown) N L Ensure that the connections are secure. Re-attach the connection cover. Install the lightbulb (not supplied). Fit the diffuser back onto the main body of the unit, ensuring it clicks firmly in place. CONNECTION DIAGRAM Mains Supply N L Isolation Switch E E L N L1

The diagram below also shows the required connections for the addition of slave luminaires. When adding slaves, be sure not to exceed the maximum switchable load (see Technical Specifications). Mains Supply N L E Isolation Switch SECTION FOUR OPERATION AND TESTING E WALK TESTING PROCEDURE The sensor will rotate from left to right. Adjust the sensor to point in the desired direction. Set the two adjustment controls on the underside of the unit (diagram C) to the following positions: TIME - Fully anti-clockwise DUSK (LUX) - Fully clockwise The unit will now operate during daytime as well as at night, illuminating the lamp for approx. 5 seconds each time. This allows testing to be carried out to establish the best position for the sensor. The lamp will immediately illuminate as the unit goes through its "warm-up" period. After approximately 1-2 minutes the lamp will extinguish. Try to remain outside the detection area during the warm-up period. Walk across the detection area approx 5 metres from the unit. As you cross a detection "zone" the lamp will illuminate. Now stand still until the lamp extinguishes (this should take approx. 5 seconds). Start moving again. As you cross each "zone" the lamp will illuminate. Repeat the above, walking at various distances and angles to the unit. This will help you to establish the detection pattern. SETTING UP FOR AUTOMATIC OPERATION When walk tests are complete, the unit can be switched to automatic operation : The TIME setting controls how long the unit remains illuminated following activation & after all motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time (fully clockwise) is approx. 5 minutes. Set the control to the desired setting between these limits. The DUSK control determines the level of darkness required for the unit to start operating. The setting is best achieved by the procedure below: Set the DUSK control knob fully anti-clockwise. Wait until darkness falls. When the ambient light level reaches the level of darkness at which you wish the lamp to become operative (ie. At dusk), SLOWLY rotate the control in a clockwise direction until a point is reached where the lamp illuminates. Leave the control set at this point. L N L1

At this position, the unit should become operative at approximately the same level of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust the control slightly anti-clockwise. If the unit starts to operate too late (ie. only when it is very dark), adjust the control slightly clockwise. Continue to adjust until the unit operates as desired. MASKING THE SENSOR LENS To reduce the sensor coverage, preventing detection in unwanted areas, mask the sensor lens using electricians tape or similar (see diagram D). For your information, the top section of the lens covers long range detection, the bottom covers short range. Similarly, the left and right lens sections cover the left and right detection areas respectively. SECTION FIVE TECHNICAL SPECIFICATIONS Detection Range Detection Angle Power Supply Maximum Switchable Load Lamp Type Time On Adjustment Dusk Level Adjustment Environmental Protection EC Directives Up to 8 metres 110º 230 V AC ~ 50Hz 500W including fitted bulb Not suitable for energy 230V 60W (max) GLS ES saving lamps 5 seconds - 5 minutes Day & night or night only operation IP44 (suitable for outdoor use) Conforms to 73/23/EEC, 89/336/EEC If you experience problems refer to Troubleshooting Guide. If problems still exist, do not immediately return the unit to store. Telephone the Timeguard Customer Helpline 020 8450 0515 Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.

SECTION SIX TROUBLESHOOTING GUIDE PROBLEM Lamp stays ON all the time at night. PIR keeps activating for no reason / at random. PIR sensor will not operate at all. SOLUTION The unit may be suffering from false activation. Cover the sensor lens completely with a thick cloth. This will prevent the sensor from "seeing" anything. If the unit now switches off after the set time duration and does not reactivate, this indicates that the problem was caused by false activation. The problem may be solved by slightly adjusting the direction/angle of the sensor head (see previous section). You may not be allowing the unit time to complete it's warm-up period. Stand well out of the detection range and wait (the warm-up period should never exceed 5 minutes). Occasionally, winds may activate the sensor. Sometimes passages between buildings etc. can cause a "wind tunnel" effect. Ensure the unit is not positioned so as to allow detection of cars/people using public thoroughfares adjacent to your property. Check that the power is switched ON at the circuit breaker/internal wall switch. Turn OFF the power to the unit and check the wiring connections as per the diagram (see previous section 3). Ensure no connections are loose. Check the lamp. If the lamp has failed, replace. Ensure that the lamp is seated correctly in the lampholder. The PIR sensor will not operate at night. Unit activates during the daytime PIR coverage is poor/sporadic Detection range varies from day to day The level of ambient light in the area may be too bright to allow operation at the current DUSK setting. During the hours of darkness, adjust the DUSK control slowly clockwise until the lamp illuminates. Refer to previous section for more details. The level of ambient light in the area may be too dark for the current DUSK setting. During daylight, adjust the DUSK control slightly anti-clockwise. When the lamp load extinguishes, enter the detection area. If the PIR still activates, the setting is still too high. Repeat the above procedure until the PIR does not activate when you enter the detection area. Refer to previous section for more details. Unit may be poorly located. See previous section - Selecting The Location and re-locate the unit. PIR sensors are influenced by climatic conditions. The colder the ambient temperature, the more effective the sensor will be. You may need to make seasonal adjustments to the sensor head position to ensure trouble-free operation all year round.

TOP VIEW A C 110º SIDE VIEW 2.5m 8m B D Lens Mask Less sensitive Restrict long detection Restrict short detection More sensitive Restrict RHS detection Restrict LHS detection

E Diffuser Fitting hole F Fitting hole Removeable connection cover Grommet Positions

CONSUMER PRODUCT RANGE SLB500 500W PIR Halogen Floodlight - Black SLW500 500W PIR Halogen Floodlight - White SLW2000 2000W PIR Light Controller - White SLB88 60W PIR Bulkhead Light - Black SLB150 150W PIR Halogen Floodlight - Black SLW89 60W PIR Bulkhead Light - White SLW150 150W PIR Halogen Floodlight - White SLB44 60W PIR Lantern Light - Black SLB2000 2000W PIR Light Controller - Black SLW45 60W PIR Lantern Light - White

Helpline 020-8450-0515 For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND or email csc@timeguard.com