SECTION 098400 ACOUSTICAL WALL TREATMENT. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.



Similar documents
Bafl-Sorb Sound Absorbing Ceiling Baffles

Fiberglas, Exterior Wall Thermal Insulation

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

SECTION STANDING SEAM METAL ROOFING

H-Stud Area Separation Wall System

PART 1 GENERAL 1.1 SECTION INCLUDES

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

Preformed Metal Roofing and Siding

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

Window Installation Instructions

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS WINDOWS

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Sun Windows General Information Sun New Construction Window Installation Instructions

GUIDELINE SPECIFICATIONS

Product Information. Tel: x2426 or x2443 Fax:

CLEAR-DIVISIONS CENTERFOLD

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

CLEAR-DIVISIONS VARIOFOLD

2. Division 05 Structural Steel Framing for steel framework requirements

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Section EXTERIOR STONE VENEER Full Mortar

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

CLEAR-DIVISIONS APERTO

INSTALLATION OF A BAY WINDOW

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

FORM DESIGN. easy to work with, and generally available.

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Wall. Between us, ideas become reality. Acoustical Wall, Baffle, and Diffuser Systems

Think Of Us First! When It s Time to Distribute Your Plans

All bidders shall indicate in their bid/proposal that this Addendum has been received and considered in their bid proposal.

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

March 14, Installation of Bay, Bow and Garden Windows

Triarch Products Over Various Interior Substrates

Product Guide Specification

Housing Fact Sheets. Energy Saving Window Treatments

GENERAL PROVISIONS

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

to control interfering reflections and provide an ambient sound field using diffusion instead of

application instructions

Fire Barrier Duct Wrap 15A

SECTION STANDING SEAM METAL ROOF

Guide Specification SECTION SHEET CARPETING PART 1 - GENERAL 1.1 SUMMARY. A. This Section includes broadloom carpet. 1.

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

B. Types of mechanical insulation specified in this section include the following:

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

FIRESTOPPING & SMOKE SEALS

SECTION METAL WALL PANELS

GigaCrete Specification PlasterMax

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Lightweight Partition Design for Residential and Commercial Buildings

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Tundra Series Windows January 2016

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

Premium Nixalite All Stainless Steel Bird Barrier Spikes Includes specifications for: Premium Nixalite Models S, H and W and Mounting Hardware.

Premier & Deluxe 3-Season Room Sliding Glass Door

Underwriters Laboratories Testing Information

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

Brick Veneer Construction

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

RACO Interior OfficeFronts. SolutionsII Typical Details. SolutionsII

ST. MONICA FOOD PANTRY HOUSTON, TEXAS

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

From the Office of: MAHLUM ARCHITECTS 71 Columbia Street Floor 4 Seattle, WA 98104

SERIES 642F SPECIFICATIONS

pinta ACOUSTIC PANEL [1/7]

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION STORM DRAIN SYSTEM

Composite Panel Firewall Systems

SECTION STORAGE SHELVING. Copyright ARCAT, Inc. - All rights reserved

GreenGuard Housewrap Installation Guide

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Frequently Asked Questions LP SmartSide Siding, Trim, and Soffit

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version

GYPSUM BOARD AND PLASTER

EcoTouch Insulation with PureFiber Technology

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

Springlok Flashing System

Transcription:

SECTION 098400 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting a bid for the work of this SECTION. 1.02 SCOPE OF WORK A. Furnish and install the following items required to complete the work of this SECTION, as shown on the Drawings and specified herein. 1. Fibrous wood wall panels (ʻFAPʼ), including all necessary attachment hardware and edging material. 2. Fabric covered acoustic panels and all necessary attachment hardware and edging material. 1.03 RELATED WORK SPECIFIED ELSEWHERE A. The following related work is to be performed under the designated SECTIONS: 1.04 SUBMITTALS 1. Metal stud and back up for fibrous wood wall panels: SECTION 092116- GYPSUM WALLBOARD. 2. Furring and blocking for attachment of wall hung items: SECTION 061000-ROUGH CARPENTRY. 3. Attachments to and penetrations of fibrous panels by trades requiring same. 4. Caulking between items furnished and installed under this SECTION and adjacent construction: SECTION 070001-DAMPPROOFING, WATERPROOFING AND CAULKING. A. Submit complete shop drawings in accordance with SECTION 013300- SUBMITTALS. 098400-1

B. Shop drawings shall include wall elevations and reflected ceiling plans of fibrous panel systems, including large scale details of attachment and adjacent construction. Include with shop drawings manufacturer's data sheets for all items specified herein. 1. Shop drawings shall include wall elevations of fibrous panel systems, including large scale details of attachment and adjacent construction. Include with shop drawings manufacturerʼs data sheets for all items specified herein. 2. Submit complete product literature for items specified herein. C. Submit the following samples in accordance with the requirements of SECTION 013300-SUBMITTALS. 1. All fibrous panels - 12 inch by 12 inch section of each type, showing specified long edge and end treatments. 2. Edging materials - 12 inch length of each type specified or required by job conditions. 3. Fabric Samples Complete standard manufacturerʼs selection for color. 098400-2

PART 2 PRODUCTS 2.01 FIBROUS WOOD PANEL SYSTEM A. General - To establish a standard of quality, function and design, drawings and specifications for fibrous acoustic panels ( FAP ) are based on fibrous wood panels as manufactured by Tectum, Inc., Newark, Ohio. B. Fibrous Wood Panels - Panels shall be composed of aspen wood fibers bonded with an inorganic hydraulic cement, and formed by a continuous process under heat and pressure, as follows: 1. Wall Panels - 2 inches thick (one inch thick where noted on drawings) by 47-1/2 inches wide by lengths shown on the drawings. Panels shall have long edges both beveled, and tongue and grooved for interlocking of continuous paneling. Panel ends at exposed butt joints shall have edges field beveled to match factory beveled long edges. Panels shall be factory painted white for field finish painting by SECTION 09901. B. Fasteners, metal furring and related hardware - as recommended by a panel manufacturer for various installation conditions. C. Edge Treatment - Aluminum shapes, factory primed white, for field painting by SECTION 090007-PAINTING. 2.02 FABRIC COVERED PANEL SYSTEM A. General To establish a standard of quality, function and design, drawings and specifications for fabric wrapped acoustic wall panels are based on ʻAPʼ acoustic panel system as manufactured by Decoustics, Getzville, NY. Similar panels by Armstrong Sandsoak and other manufacturers will be considered for approval as an equal by the architect upon receipt of adequate supporting data and samples. B. General System shall include the following components 1. Fabric covered panels 2. Fasteners, adhesive, clips and hook and loop fasteners as recommended by the panel manufacturer for the installation conditions. C. Fabric covered panels 1. Medium density core with square resin hardened edges, one and two inches thickness as shown on the drawings. Panels shall be factory finished with fabric finish bonded to the panel face, edges, and one inch on the back. Fabric shall be flat and wrinkle free and fully tailored at the corners with no exposed darting. 2. Panel and fabric shall have a flame spread rate of 25 or less and smoke developed rate of 450 or less under ASTM E-84. 098400-3

3. Fabric and color shall be selected by Architect from manufacturerʼs standard selection. 4. Panels shall have the following noise reduction coefficient values when tested in accordance with ASTM C-423 (type ʻAʼ mounting per ASTM E- 795). Panel Frequency (Hz) Thickness Finish 125 250 500 1000 2000 4000 NRC SAA 2 Fabric 0.23 0.81 1.19 1.19 1.11 1.12 1.05 1 Fabric 0.03 0.37 0.89 1.10 1.09 1.05 0.85 0.87 098400-4

PART 3 EXECUTION 3.01 INSTALLATION A. Install acoustic panels in strict accordance with manufacturer's requirements and the approved shop drawings. B. Secure fibrous wood panels to metal studs, furring and masonry substrates using "blind" mechanical fasteners wherever possible. When installation requirements necessitate face fastening, fastener heads shall be slightly depressed, with void filled with wood fibers (from panel) and white glue. Fasteners shall not be less than 16 inches on center. C. Furnish and install fibrous wood panels in lengths to minimize end jointing, in accordance with the Contract Documents and approved shop drawings. Where required, field cut and fit and fill ends of panels for a tight butt joint. 1. Where shown on the drawings, field bevel ends of panels to match factory bevel on long edge. D. Fabric covered panels shall be factory fabricated to sizes shown on the drawings and installed using mechanical, mechanical/velcro and mechanical/adhesive combination in strict conformance to manufacturerʼs recommendations. Install pre-painted trim over cut edges. 3.02 ADDITIONAL MATERIAL A. Provide to the Owner on completion of work, maintenance stock of facric finishes used in an identical dye lot, the greater of an amount equal to 2% of the total yardage required or enough material to cover one of the largest acoustical units supplied, whichever is greater. END OF SECTION 098400-5