Submersion/Insertion Toroidal Sensor

Similar documents
Submersion/Insertion Toroidal Sensor

Sanitary and CIP Toroidal Sensor

ENDURANCE Conductivity Sensors

Toroidal Conductivity Sensor

General Purpose ph/orp Sensors

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

For additional information, please visit our website at

Trace Dissolved Oxygen Sensor

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

General Purpose ph/orp Sensor

Dissolved Oxygen Sensors

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation Instructions S

Installation Instructions

PART 1 - INTRODUCTION...

REPAIR AND MAINTENANCE MANUAL

Digital inductive conductivity transmitter

Installing a Probe. Typical Installation

Baumann Flexsleev Sanitary Control Valve

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

with installation dynafact boost GAUGE this manual is for use with systems

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Oil and Coolant Circulating Heating System. Model - OCSM

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Watts Pure Water Systems

Your safety and the safety of others are very important.

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Powers Controls TH 192 S Single Temperature Room Thermostat

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Stainless Steel Single and Dual Circulation Kits

Easy Tool Retracting System CMC-SR2159ER36

SureSite Magnetic Liquid Level Indicator

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Installation Instructions

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Micro Motion Model D and DL Coriolis Flow and Density Meters

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Auto-belay Cable Replacement Process

Tech Bulletin. Hose / Cord Replacement and Required Wraps. Series RT

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

INSTALLATION INSTRUCTIONS for INSIGHT FIBER OPTIC FLAME SCANNERS

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Model 43AP Pneumatic Controller, Style B

INSTALLATION MANUAL. Installation Instructions

DC400 Dispensing Cutoff System

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

The Unique Accelabar Flow Meter

Threaded Resistance Thermometers Model TR10-D, Miniature Design

VOYAGER 570G. 744A Sprayer Control

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Instruction Manual. Cable Splicing. Models , HDF1, HDF SS1

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

CHROME FRONT BRAKE MASTER CYLINDER KIT

Connecting the Channel A

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

2006 JUDY SERVICE GUIDE

Installation and Maintenance Instructions

STC 3S A Series Solenoid Valves

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Models SFP33 & SFP32 Pressure Transmitters

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

TY-FLO Needle Valves

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

INSTALLATION & OPERATING INSTRUCTIONS

HP UPS R1500 Generation 3

Fiberstars Lighted Laminar Flow Fountain Installation Manual

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Float and Thermostatic Traps Series H, C and X

INSTRUCTIONS. FLHR/C/S (Road King) FRONT END LOWERING KIT 1WARNING -J03242 REV General. Removal (Left and Right Forks) Kit Number

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Trunnion-Design Ball Valves

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

Baumann Way Bronze or Stainless Steel Control Valve

WAVELET WATER QUALITY MONITORING KIT

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Installation Instructions

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

SWIMMING POOL HEAT PUMP Owners Manual

LED Security Spotlight User Manual

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Transcription:

Instruction Manual 228 Sensor LIQ_MAN_ABR_228 May 2014 PN 51A-228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.rosemountanalytical.com CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor materials may not be compatible with process com position and operating conditions. Application compat ibility is entirely the responsibility of the user. CAUTION Before removing the sensor, be absolutely certain that the process pressure is reduced to 0 psig and the process temperature is lowered to a safe level! Specifications - Sensors Model Wetted Materials Temperature Pressure CRN pressure* 228-02 PEEK (glass-filled) 248 F (120 C) 295 psig (2135 kpa abs) 220 psig (1618 kpa abs) 228-03 PEEK (glass-filled) 392 F (200 C) 295 psig (2135 kpa abs) 220 psig (1618 kpa abs) 228-04 Tefzel (glass-filled) 248 F (120 C) 200 psig (1480 kpa abs) 150 psig (1135 kpa abs) 228-05 Tefzel (unfilled) 248 F (120 C) 200 psig (1480 kpa abs) 150 psig (1135 kpa abs) * Maximum pressure for applications requiring CRN registration Specifications - Retraction Assemblies PN 23311-00 (mechanical) 23311-01 (manual) Wetted Materials 316 SS, Teflon, EPDM 316 SS, Teflon, EPDM Specifications - Adapters Operating Conditions Retraction/Insertion Conditions Temperature Pressure Temperature Pressure 392 F (200 C) 392 F (200 C) 295 psig (2135 kpa abs) 295 psig (2135 kpa abs) 392 F (200 C) 266 F (130 C) 295 psig (2135 kpa abs) 35 psig (343 kpa abs) PN Wetted Materials Temperature Pressure CRN pressure* 23242-02 PEEK, Viton, 316 SS 392 F (200 C) 295 psig (2135 kpa abs) 220 psig (1618 kpa abs) 23242-03 PEEK, Viton, 316 SS 392 F (200 C) 295 psig (2135 kpa abs) 220 psig (1618 kpa abs) 2001990 CVPC, PEEK, Viton * Maximum pressure for applications requiring CRN registration 100 F (38 C) at 100 psig (791 kpa abs) 185 F (85 C) at 45 psig (412 kpa abs) NA

228 Sensor Instruction Manual May 2014 LIQ_MAN_ABR_228 Figure 1. Adapter PN 23242-02 use with 228-21 (¾ in. MNPT) FIigure 2. Adapter PN 23242-03 use with 228-20 (⅝-11 UNC threads) Figure 3. Adapter PN 2001990 use with 228-21 (¾ in. MNPT) Installation Keep at least 1 in. (2.5 cm) between the sensor and pipe walls. If the clearance is too small, calibrate the sensor in place. Ensure that the sensor is completely submerged in liquid. Mounting the sensor in a vertical pipe run with the flow from bottom to top is best. If the sensor must be mounted in a horizontal pipe run, orient the sensor in the 3 o clock or 9 o clock position. Wiring Keep sensor wiring away from AC conductors and high current demanding equipment. Do not cut cable. Cutting the cable may void the warranty. Note For additional wiring information on this product, including sensor combinations not shown here, please refer to either our online wiring programs or the Manual DVD enclosed with each product. 1056, 1057, 56, 5081, 6081, 54e, and XMT : http://www3.emersonprocess.com/raihome/sp/liquid/wiring/xmt/ 1066 and sensors with SMART preamps: http://www2.emersonprocess.com/en-us/brands/rosemountanalytical/liquid/sensors/ Pages/Wiring_Diagram.aspx 1055: http://www3.emersonprocess.com/raihome/sp/liquid/wiring/1055/ Figure 4. Wire Functions 2

Instruction Manual 228 Sensor LIQ_MAN_ABR_228 May 2014 PN 51A-228 Figure 5. Wiring 228-54 and 228-56 sensors to 1056 and 56 analyzers Figure 6. Wiring 228-54 and 228-56 sensors to 54eC analyzer 3

228 Sensor Instruction Manual May 2014 LIQ_MAN_ABR_228 Figure 7. Wiring 228-54 and 228-56 sensors to Xmt-T panel mount transmitter Figure 8. Wiring 228-54 and 228-56 sensors to Xmt-T pipe/wall mount transmitter 4

08-95 Instruction Manual 228 Sensor LIQ_MAN_ABR_228 May 2014 PN 51A-228 Figure 9. Wiring 228-54 and 228-56 sensors to 1066 transmitter TB2 TB1 TB2 TB1 RTN SENSE RTD IN SHLD GREEN WHITE CLEAR BLACK GREEN BLACK WHITE RCV B RCV A RSHLD DRV B DRV A DSHLD RTN SENSE RTD IN SHLD CLEAR GREEN WHITE BLACK BLACK GREEN CLEAR BLACK WHITE CLEAR RCV B RCV A RSHLD DRV B DRV A DSHLD 228-54 228-56 CLEAR CLEAR CLEAR CLEAR SHIELD SHIELD IS IS NOT NOT CONNECTED. IT IS PRESENT CONNECTED. IN HIGH TEMPERATURE IT IS PRESENT (OPTION-03) IN HIGH ONLY TEMPERATURE (OPTION-03) ONLY Figure 10. Wiring 228-54 and 228-56 sensors to 5081-T transmitter NOTES: UNLESS OTHERWISE SPECIFIED DRAWN CHECKED PROJECT ENGR APVD APPROVALS THIS DWG CREATED IN SOLID EDGE DATE C. HOANG 7-7-10 J. COVEY 7-23-10 Rosemount Analytical, Inc. 2400 Barranca Pkwy Irvine, CA 92606 NOTES: UNLESS OTHERWISE SPECIFIED TITLE WIRING MODEL 228-54 SENSOR TO MODEL 1066 B SIZE DWG NO REV 40106601 B DRAWN CHECKED PROJECT ENGR APVD APPROVALS THIS DWG CREATED IN SOLID EDGE DATE C. HOANG 7-7-10 J. COVEY 7-23-10 TITLE Rosemount Analytical, Inc. 2400 Barranca Pkwy Irvine, CA 92606 WIRING MODEL 228-56 SENSOR TO MODEL 106 B SIZE DWG NO REV 40106604 B 5

228 Sensor Instruction Manual May 2014 LIQ_MAN_ABR_228 Wiring through a Remote Junction Box Figure 11. Wiring sensors through a remote junction box Wire sensors point to point. For wiring at the analyzer end, refer to the appropriate analyzer wiring diagram. For interconnecting cable 23294-00, use the 228-54 wiring diagram. For interconnecting cable 23294-05, use the 228-56 wiring diagram. Figure 12. Remote Junction Box (PN 23550-00) 6

Instruction Manual 228 Sensor LIQ_MAN_ABR_228 May 2014 PN 51A-228 Insertion - Retraction Assemblies Installation Requirements 1. Process connection: 1 ½ inch. Larger openings may keep the sensor from inserting far enough into the process liquid. 2. Line size: 3 in.; 2-in. line requires in-place calibration. 3. Valve: 1 ½ NPT full port ball valve (PN 9340065). 4. Retraction clearance: 2 ft (0.6 m). 5. Provide mechanical support if excess vibration is expected. 6. Flush water: provide ⅛ in. valves in inlet and outlet flush ports. Position flush ports so that retraction chamber can be drained. Manual Retraction Assembly (PN 23311-01) Installation 1. Loosen the collet nut and retract the sensor tube into the retraction chamber. See Figure 14. 2. Loosen the union nut and separate the retraction chamber from the assembly. 3. Install the retraction chamber on the 1 ½ in. NPT full port ball valve mounted on the process line or vessel. 4. Thread the sensor cable through the tube into the junction box. Screw the sensor into the tube. Hand tighten the sensor an additional half turn once the gasket is seated. 5. Connect the sensor and interconnecting cable leads to the terminal strip in the junction box. See figure 13. 6. Connect the other end of the cable to the analyzer. See the wiring diagrams in Figures 5 through 10. For cable PN 23294-00 follow the wiring for the 228-54 sensor. For cable PN 23294-05, follow the wiring for the 228-56 sensor, with the following exception: Refer to the wire function diagram for the 228-56 option in figure 4 and identify the RTD wire bundle. Connect the RTD wires to the analyzer as follows: Green RTD in Black no connection Clear RTD common or RTD return White RTD sense Wrap the bare end of the black wire to prevent accidental connections. 7. Insert the sensor and tube assembly into the retraction chamber. 8. Tighten the union nut. 9. Open the ball valve, check for leaks, and manually insert the sensor into the process. 10. Position the sensor at least ½ in. (13 mm) away from any wall of the vessel or pipe. 11. Tighten the collet nut. Figure 13. Sensor-Mounted Junction Box Wiring The wiring diagram shown is for cable PN 23294-00, which has three RTD (TC) leads. If you are using cable PN 23294-05, which has four RTD (TC) leads, connect the green, white, and clear wires in the RTD bundle as shown in the drawing. Do not connect the black wire. When you connect the RTD wires in PN 23294-05 to the analyzer, make the connections as described in step 6 of Manual Retraction Assembly (Installation) above or step 3 of Mechanical Retraction Assembly (Installation) on page 9. Cable PN 23294-00 7

228 Sensor Instruction Manual May 2014 LIQ_MAN_ABR_228 Retraction 1. Make certain that the system pressure is less than 35 psig (342 kpa abs). Push in on the sensor using the top of the junction box. Slowly loosen the collet nut. Figure 14. Manual Refraction Assembly WARNING Severe impact injury can occur if the collet nut is loosened under pressure. 2. When the collet nut is loose enough, slowly ease the sensor back so that it clears the ball valve. Close the valve to the process line. 3. Drain the retraction chamber contents using the ⅛ in. flush ports. 4. Loosen the 3 in. hex union nut. Remove the sensor and tube assembly. 5. Replace the 3 in. hex nut O ring. Place the sensor and tube assembly back in the retraction assembly. Tighten the 3 in. hex union nut. Verify that the ⅛ in. flush ports are closed. Note With the ball valve closed and the retraction chamber ⅛ in. flush ports open, some residual process fluid may leak from the 3 in. hex union nut female ACME threads. This leakage is normal and to be expected. 6. Before opening the ball valve, make sure that the process pressure is less than 35 psig (342 kpa abs). Open the ball valve and check for leaks. Insert the sensor into the process. Tighten the collet nut. WARNING Retraction chamber contents may be under pressure 8

Instruction Manual 228 Sensor LIQ_MAN_ABR_228 May 2014 PN 51A-228 Mechanical Retraction Assembly (PN 23311-00) Installation 1. Thread the sensor cable through the tube into the junction box. Screw the sensor into the tube. Hand tighten the sensor an additional half turn once the gasket is seated. See Figure 15. 2. Terminate the sensor wiring in the junction box. See Figure 13 for wiring details. 3. Connect the other end of the cable to the analyzer. See the wiring diagrams in Figures 5 through 10. For cable PN 23294-00 follow the wiring for the 228-54 sensor. For cable PN 23294-05, follow the wiring for the 228-56 sensor with the following exception: Refer to the wire function diagram for the 228-56 option in Figure 4 and identify the RTD wire bundle. Connect the RTD wires to the analyzer as follows: Green RTD in Black no connection Clear RTD common or RTD return White RTD sense Wrap the bare end of the black wire to prevent accidental connections. 4. Using a ½ in. (13 mm) socket wrench, retract the sensor into the retraction chamber. 5. Install the assembly on the 1 ½ in. NPT full port ball valve mounted in the process line or vessel. 6. Tighten the union nut. 7. Open the ball valve and check for leaks. 8. Using a ½ in. (13 mm) socket wrench, insert the sensor into the process line or vessel. 9. Position the sensor at least ½ in. (13 mm) away from any wall of the vessel or pipe. Set the travel stop collar A next to the nut housing. WARNING Do not loosen cap screws or collar when pressurized Retraction 1. Make certain that the system pressure is less than 295 psig (2135 kpa abs) before retracting the sensor. 2. Retract the sensor using a ½ in. (13 mm) socket wrench. When the sensor clears the ball valve, close the valve. WARNING Retraction chamber contents may be under pressure 3. Drain the retraction chamber contents using the ⅛ in. flush ports. Figure 15. Manual Refraction Assembly 4. Loosen the 3 in. hex union nut, and remove the retraction stop collar and orange clamp top. Remove the sensor and tube assembly. 5. Replace the 3 in. hex nut O ring. Place the sensor and tube assembly back in the retraction assembly. Replace the retraction stop collar about ½ in. in front of the clamp. Tighten the clamp screws, retraction stop collar, and 3-in. hex union nut. Verify that the ⅛ in. flush ports are closed. Note With the ball valve fully closed and the retraction chamber ⅛ in. flush ports open, some residual process fluid may leak from the 3 in. hex union nut female ACME threads. This leakage is normal and to be expected. 6. Before opening the ball valve, make sure that the process pressure is less than 295 psig (2135 kpa abs). Open the valve, check for leaks, and insert sensor into the process. 9

228 Sensor Instruction Manual May 2014 LIQ_MAN_ABR_228 Replacing Seals in Manual and Mechanical Retraction Assemblies 1. Retract the sensor into the retraction chamber and fully close the ball valve. 2. Drain the retraction chamber contents using the ⅛ in. flush ports. WARNING Retraction chamber contents may be under pressure 3. (Mechanical) Mark the location of the nut housing cap and retraction collar on the sensor tube. Remove both socket head cup screws from the nut housing and loosen the retraction stop collar. 4. Remove the 3 in. Hex Union nut. 5. Withdraw the sensor from the retraction chamber. 6. Open the junction box and disconnect the sensor wires from the terminal block. 7. Remove the compression fitting just below the junction box and remove the junction box from the sensor tube. 8. (Manual) Pull down the nut guard and remove the collet nut from the bushing housing. 9. Slide all hardware including the bushing housing off the sensor tube. 10. Remove the retaining ring from the bottom of the bushing housing. 11. Remove the Teflon guard. 12. From the top of the bushing housing press out the Teflon bushing. This will also push out the Teflon cup seal. 13. Replace all damaged parts with replacement parts from Figure 16 or 17. Replace the sensor tube if the surface is damaged. A rough or uneven surface will prevent the Teflon cup from sealing. 14. Rebuild the bushing housing. The open end of the cup seal (spring visible) faces the process. 15. Carefully slide the bushing housing onto the sensor tube. Do not damage the Teflon bushing or the Teflon cup seal. 16. (Manual) Slide the 3 in. Hex Union nut, collet nut with nut guard, junction box compression nut, and plastic ferrules onto the sensor tube. 17. (Mechanical) Slide the 3 in. Hex Union nut, retraction stop collar, junction box compression nut, and plastic ferrules onto the sensor tube. 18. Connect the junction box to the sensor tube and wire the sensor leads to the appropriate terminals. 19. (Mechanical) Lock the retraction stop collar into position (see Figure 15 or previously marked position for proper location). 20. Place the Union nut O-ring on the bottom of the bushing housing. Insert the sensor assembly into the retraction chamber and tighten the 3 in. Hex Union nut. 21. (Mechanical) Install the nut housing cap (see Figure 15 or previously marked position for proper location). 10

Instruction Manual 228 Sensor LIQ_MAN_ABR_228 May 2014 PN 51A-228 Figure 16. Mechanical Retraction Assembly Replacement Parts 11

228 Sensor Instruction Manual May 2014 LIQ_MAN_ABR_228 Figure 17. Manual Retraction Assembly Replacement Parts 12

Instruction Manual 228 Sensor LIQ_MAN_ABR_228 May 2014 PN 51A-228 Calibration The nominal cell constant of the 228 sensor is 2.7/cm. The error in the cell constant is about ±10 %, so conductivity readings made using the nominal cell constant will have an error of at least ±10 %. Wall effects, discussed below, will likely make the error greater. For higher accuracy, the sensor must be calibrated. Wall effects arise from the interaction between the current induced in the sample by the sensor and nearby pipe or vessel walls. As Figure 18 shows, the measured conductivity can either increase or decrease depending on the wall material. Because wall effects do not disappear until the 228 sensor is at least 1 inch (25 mm) away from the nearest wall, wall effects are present in most installations. Correcting for them is an important part of calibration. Conductivity sensors are calibrated against a solution of known conductivity (a standard) or against a previously calibrated referee sensor and analyzer. If wall effects are present, calibrating a toroidal sensor with a standard solution is possible only if the vessel holding the standard has exactly the same dimensions as the process piping. If the 228 sensor is installed in a tee, duplicating the process environment in the laboratory or shop might be possible. Otherwise, calibration against a standard solution is probably impractical. The alternative is to calibrate the sensor in place against a referee sensor and analyzer, ideally while both sensors are simultaneously measuring the same process liquid. If this is not practical, calibrate the process sensor against the results of a measurement made on a grab sample. For more information about calibrating toroidal conductivity sensors, refer to application sheet ADS 43-025 available on the Rosemount Analytical website. Figure 18. Measured conductivity as a function of clearance between sensor and walls measured conductivity metal pipe true conductivity true conductivity 1 inch (25mm) distance to wall 13

228 Sensor Instruction Manual May 2014 LIQ_MAN_ABR_228 Maintenance Generally, the only maintenance required is to keep the opening of the sensor clear of deposits. Cleaning frequency is best determined by experience. WARNING Retraction chamber contents may be under pressure CAUTION Be sure sensor has been cleaned of process liquid before handling. Troubleshooting Problem Probable Cause Solution Off-scale reading Noisy reading Reading seems wrong (lower or higher than expected) Sluggish response. Wiring is wrong. RTD is open or shorted. Sensor is not in process stream. Verify and correct wiring. Check the RTD for open or short circuits. See Figure 19 Confirm that the sensor is fully submerged in the process stream. See installation section. Sensor is damaged. Perform isolation checks. See Figure 19. Sensor is improperly installed in the process stream. Sensor cable is run near high voltage conductors. Sensor cable is moving. Bubbles are trapped in the sensor, particularly in the toroid opening. Sensor is not completely submerged in the process stream. Cell constant is wrong. Wall effects are present. Wrong temperature correction algorithm is being used. Temperature reading is inaccurate. Slow temperature response to sudden changes in temperature. Sensor is installed in a dead area in the piping. Slow temperature response to sudden changes in temperature. Confirm that the sensor is fully submerged in the process stream. See installation section. Move cable away from high voltage conductors. Keep sensor cable stationary. Install the sensor in a vertical pipe run with the flow against the toroid opening. Increase flow if possible. Confirm that the sensor is fully submerged in the process stream. See installation section. Calibrate the sensor in place in the process piping. See calibration section. Check that the temperature correction is appropriate for the sample. See analyzer manual for more information. Disconnect the RTD leads (Figure 19) and measure the resistance between the in and common leads. Resistance should be close to the value in Table 1. Use an RTD in a metal thermowell for temperature compensation. Move sensor to a location more representative of the process liquid. Use an RTD in a metal thermowell for temperature compensation. 14

Instruction Manual 228 Sensor LIQ_MAN_ABR_228 May 2014 PN 51A-228 Figure 19. Resistance check. Disconnect leads from analyzer before measuring resistances. Table 1. Temperature Resistance 10 C 103.9 Ω 20 C 107.8 Ω 25 C 109.7 Ω 30 C 111.7 Ω 40 C 115.5 Ω 50 C 119.4 Ω 15

228 Sensor Instruction Sheet May 2014 LIQ_MAN_ABR_228 Rev. R facebook.com/emersonrosemountanalytical AnalyticExpert.com Credit Cards for U.S. Purchases Only. twitter.com/raihome youtube.com/user/rosemountanalytical Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 rosemountanalytical.com Rosemount Analytical Inc. 2014 2014 Rosemount Analytical, Inc. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand name is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.