Sanitary and CIP Toroidal Sensor



Similar documents
Submersion/Insertion Toroidal Sensor

Submersion/Insertion Toroidal Sensor

Toroidal Conductivity Sensor

ENDURANCE Conductivity Sensors

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

For additional information, please visit our website at

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

Dissolved Oxygen Sensors

Trace Dissolved Oxygen Sensor

General Purpose ph/orp Sensor

PART 1 - INTRODUCTION...

General Purpose ph/orp Sensors

The Unique Accelabar Flow Meter

THEORY AND APPLICATION OF CONDUCTIVITY

Digital inductive conductivity transmitter

Micro Motion Model D and DL Coriolis Flow and Density Meters

Sanitary Type Electronic Flow Switches

Models SFP33 & SFP32 Pressure Transmitters

Electric Heat Tracing INSTALLATION PROCEDURES

TB2CS Conductivity sensor 2-Electrode. Superior accuracy in low level conductivity measurement ranges

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Charge Regulator SCR 12 Marine

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Replacing Displacers with Guided Wave Radar

Instruction Manual PN /rev E March Model 242 Flow-Through Toroidal Conductivity Sensor

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

T0118 T2118 T3118. Instruction Manual

ATL Fuel Level Sender Probes

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

T7079A,B Solid State Remote Temperature Controllers

Load Cell Troubleshooting

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Quick Connect. RTDs, Cordsets and Transmitter with M12 Connections

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

HMI display Installation Guide

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Multi-Parameter Electrochemical / Optical Water Quality System

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

8146/5 Series Breaker Panelboards

Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers

3-Component Measuring System

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

SDX Submersible Depth Transmitter User Manual

Oil and Coolant Circulating Heating System. Model - OCSM

DS 600. A contact free flux gate based current measurement sensor 600A rms

PRODUCT PROFILE FEATURES

Duct Humidity Transmitter

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Contents. Document information

, User s Manual

T7560A,B,C Digital Wall Module

BB-18 Black Body High Vacuum System Technical Description

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Series DFMT Digital Paddlewheel Flowmeter

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Series 510 Submersible Level Transmitters

Antenna Splitter ASA 1. Instruction manual

Drayton Digistat +2RF/+3RF

Chapter2. Installation

Solar Panel Installations

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

OPL BASIC. Dosing System for Professional Laundry machines. Contents

PERF10 Rubidium Atomic Clock

Butterfly Valves PN 6/10/16 for flanged connection

TMS TANK MANAGEMENT SYSTEM

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Analog signal converters CC-E I/I Current / current isolators

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

46120-F0 Solar Energy Training System

BX7000 Multi-Access Gateway Getting Started Guide

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

OLI. Oil level indicator

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Manual for Fire Suppression & Methane Detection System

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Transcription:

Instruction Sheet PN 51A-225/rev.I December 2010 Model 225 Sanitary and CIP Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor materials may not be compatible with process com position and operating conditions. Application compat ibility is entirely the responsibility of the user. WARNING CAUTION Before removing the sensor, be absolutely certain that the process pressure is reduced to 0 psig and the process temperature is lowered to a safe level! SPECIFICATIONS MODEL Wetted Materials Temperature Pressure 225-03 PEEK (glass-filled) 230 F (110 C) 200 psig (1480 kpa abs) 225-07 Unfilled PEEK, meets 21CFR177.2415 1 266 F (130 C) 200 psig (1480 kpa abs) 225-08 Unfilled PEEK, meets USP Class VI 266 F (130 C) 200 psig (1480 kpa abs) 225-09 Tefzel (unfilled) 230 F (110 C) 200 psig (1480 kpa abs) 1 Sensor meets 3A sanitary requirements for sensors and sensor fittings and connections used on milk and milk products equipment (74-03). INSTALLATION The sensor may be installed in either a tank or pipe using a customer-supplied Triclamp and tee assembly. The sensor requires a 2-inch Tri-clamp, a 2-inch type 1 gasket, and a 2-inch tank ferrule or tee. Keep at least 1 in. (25 cm) between sensor and pipe wall. If clearance is too small, calibrate the sensor in place. Ensure that the sensor is completely submerged in liquid to the flange. Mounting the sensor in a vertical pipe run with the flow from bottom to top is best. If the sensor must be mounted in a horizontal pipe run, orient the sensor in the 3 o clock or 9 o clock position. FIGURE 1. Dimensions

INSTALLATION WIRING Keep sensor wiring away from ac conductors and high current demanding equipment. Do not cut cable. Cutting the cable may void the warranty. FIGURE 2. Wire Functions FIGURE 3. Wiring 225-54 and 225-56 sensors to Model 1056 and 56 analyzers 2

INSTALLATION FIGURE 4. Wiring 225-54 and 225-56 sensors to Model 54eC analyzer FIGURE 5. Wiring 225-54 and 225-56 sensors to Model Xmt-T panel mount transmitter 3

WIRING FIGURE 6. Wiring 225-54 and 225-56 sensors to Model Xmt-T pipe/wall mount transmitter TB2 RTN SENSE RTD IN SHLD GREEN WHITE GREEN WHITE TB1 RCV B RCV A RSHLD DRV B DRV A DSHLD TB2 RTN SENSE RTD IN SHLD GREEN WHITE GREEN WHITE TB1 RCV B RCV A RSHLD DRV B DRV A DSHLD (NOT USED) 225-54 225-56 FIGURE 7. Wiring 225-54 and 225-56 sensors to Model 1066 transmitter. 4

WIRING FIGURE 8. Wiring 225-54 and 225-56 sensors to Model 5081-T transmitter PRESENT IN 23294-05 ONLY AND PN 23294-04 FIGURE 9. Wiring sensors through a remote junction box Wire sensors point to point. For wiring at the analyzer end, refer to the appropriate analyzer wiring diagram. For interconnecting cable 23294-00, use the 225-54 wiring diagram. For interconnecting cable 23294-04 and 23294-05, use the 225-56 wiring diagram. 5

CALIBRATION FIGURE 10. Remote Junction Box (PN 23550-00) CALIBRATION The nominal cell constant of the Model 225 sensor is 2.7/cm. The error in the cell constant is about ±10%, so conductivity readings made using the nominal cell constant will have an error of at least ±10%. Wall effects, discussed below, will likely make the error greater. For higher accuracy, the sensor must be calibrated. Wall effects arise from the interaction between the current induced in the sample by the sensor and nearby pipe or vessel walls. As Figure 11 shows, the measured conductivity can either increase or decrease depending on the wall material. Because wall effects do not disappear until the Model 225 sensor is at least 1 inch (25 mm) away from the nearest wall, wall effects are present in most installations. Correcting for them is an important part of calibration. Conductivity sensors are calibrated against a solution of known conductivity (a standard) or against a previously calibrated referee sensor and analyzer. If wall effects are present, calibrating a toroidal sensor with a standard solution is possible only if the vessel holding the standard has exactly the same dimensions as the process piping. Model 225 sensors are often installed in sanitary flange tees, so an appropriate calibration vessel is another tee with blank flanges on the ends. If removing the sensor from the process piping for calibration is impractical, calibrate the sensor in place against a referee sensor and analyzer while both sensors are simultaneously measuring the process liquid. If this is not practical the sensor can also be calibrated against the results of a measurement made on a grab sample. For more information about calibrating toroidal conductivity sensors, refer to application sheet ADS 43-025 available on the Rosemount Analytical website. MAINTENANCE CAUTION Be sure sensor has been cleaned of process liquid before handling. Generally, the only maintenance required is to keep the opening of the sensor clear of deposits. Cleaning frequency is best determined by experience. FIGURE 11. Measured conductivity as a function of clearance between sensor and walls 6

TROUBLESHOOTING TROUBLESHOOTING PROBLEM PROBABLE CAUSE SOLUTION Off-scale reading Wiring is wrong. Verify and correct wiring. RTD is open or shorted. Sensor is not in process stream. Check the RTD for open or short circuits. See Figure 12. Confirm that the sensor is fully submerged in the process stream. See installation section. Sensor is damaged. Perform isolation checks. See Figure 12. Noisy reading Sensor is improperly installed in the Confirm that the sensor is fully submerged process stream. in the process stream. See installation section. Sensor cable is run near high voltage conductors. Sensor cable is moving. Move cable away from high voltage conductors. Keep sensor cable stationary. Reading seems wrong (lower Bubbles are trapped in the sensor, Install the sensor in a vertical pipe run with or higher than expected) particularly in the toroid opening. the flow against the toroid opening. Increase flow if possible. Sensor is not completely submerged in the process stream. Cell constant is wrong. Wall effects are present. Wrong temperature correction algorithm is being used. Temperature reading is inaccurate. Slow temperature response to sudden changes in temperature. Confirm that the sensor is fully submerged in the process stream. See installation section. Calibrate the sensor in place in the process piping. See calibration section. Check that the temperature correction is appropriate for the sample. See analyzer manual for more information. Disconnect the RTD leads (Figure 12) and measure the resistance between the in and common leads. Resistance should be close to the value in Table 1. Use an RTD in a metal thermowell for temperature compensation. Sluggish response Sensor is installed in a dead area in the Move sensor to a location more representative piping. of the process liquid. Slow temperature response to sudden changes in temperature. Use an RTD in a metal thermowell for temperature compensation. TABLE 1. Temperature Resistance 10 C 103.9 Ω 20 C 107.8 Ω 25 C 109.7 Ω 30 C 111.7 Ω 40 C 115.5 Ω 50 C 119.4 Ω 7

FIGURE 12. Resistance check. Disconnect leads from analyzer before measuring resistances. The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Specifications subject to change without notice. 8 Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2010