NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!



Similar documents
Flexit air handling unit K2 R

Flexit SPIRIT K2R. Air handling unit with integrated kitchen hood

FLEXIT S4 R S6 R S7 R

94210E L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating

94122E FLEXIT L4 X/TT L7 X/TT. User Manual. Air Handling Unit Loft Models with Heat Recovery

FLEXIT S3 X/TT A3 X/TT K3 X/TT S3 R S3 RK

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

111538E Flexit SPIRIT UNI 2. Installation Instructions. Air Treatment Unit & Automatic Control

Installation, operation and maintenance manual TX 35A

IH E Sigma Island 90

Flexit Central Vacuum Cleaner

Flexit Central Vacuum Cleaner

ECOCIAT. Domestic hot water heat recovery unit

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Installation and maintenance instructions. Danfoss Vent

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

ELECTRIC CENTRAL HEATING FLOW BOILER

Accessory Manual Ventilation Section Model Comfort Circle

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

squrboxbox heat recovery squrboxbox I technical information

UDSA - UDSBD unit heater

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

Important Safeguards

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

CADB and CADT-D / DI / DC Series

Topvex SX/C, Topvex TX/C. Air Handling Unit

Energy Efficiency HOSPITALITY.

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

USER S MANUAL HSC-24A

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Drayton Digistat +2RF/+3RF

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Installation Instructions

HDA

Industrial infrared heater IR For premises with large volumes and high ceilings

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

air conditioners how to choose a cooling system

Energy Efficiency. Bars & RestauRants.

This section gives you some helpful information and tips on running your home and the equipment in it.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

User Manual THR840DUK Digital Thermostat

121MC. Vallox. Low-energy ventilation unit with heat recovery. Operating, maintenance and technical instructions. Vallox EN 14.5.

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Portable Air Conditioner

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Spetec. Laminar Flow Box. Portable Clean Room Technology

HERZ-Thermal Actuators

HEAVY DUTY STORAGE GAS

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

york air-conditioning products Residential & VRF News 2015

User's Instructions. Alpha HE CB25/33 and HE SY25

RRV934. Multi-controller. Synco living

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Surface Technology. Centrifugal Fan GMD

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Stove Guard Kit User Manual

The compact unit series

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Rotary screw compressors kw 5,5 7, , bar MODULO

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

2-SLICE COOL TOUCH TOASTER

Displacement ventilation

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Network Time Accessories LED CLOCK. (for NTP Synchronization)

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

Meaco 30L and Meaco 40L dehumidifier instruction manual

Cooktop Low-Profile Ventilation Hoods

Cooling system components, removing and installing

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Instructions for designing heating systems.

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Inverter Air Conditioning for Light Commercial Use

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Delivering exceptional performance and Ecovalue. Ecocent

Heating oven with mechanical convection

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Transcription:

Flexit SL4 R Air Handling Unit with rotating recovery system Energy-efficient New control system NEW! Patent applied for! - Simple settings - Flexible installation - User friendly F O R H E A LT H Y I N D O O R A I R Q U A L I T Y

2

Flexit SL4 R air handling unit with rotor technology - Energy-efficient - Flexible installation - User friendly Flexit s new ventilation unit has a number of important product advantages and meets the new stricter energy efficiency requirements being introduced in various European countries. The unit has a unique design (patent applied for) which gives great flexibility of installation in terms of positioning of ducts and location of the unit. Flexit SL4 R has a rotating recovery system that ensures high recovery and simple installation. The unit is compact and has small physical dimensions (height 700 mm, width 598 mm and depth 450 mm). Flexit SL4 R is suitable for detached houses, smaller homes and flats and smaller offices. The unit can be connected to an external cooker hood. Energy savings and efficiency A balanced ventilation unit with rotating recovery system lowers the cost of heating up ventilation air by up to 80% compared to an extract unit. Example of savings in an ordinary semi-bungalow: Heating requirement with central extraction: approx. 10,600 kwh per year. Heating requirement with balanced ventilation with 80% heat recovery: approx. 2120 kwh per year. Saving: 8480 kwh per year, multiplied by energy cost for heating. With a balanced ventilation unit with heat recovery you save up to 80% of the cost of heating the ventilation air compared to an extraction unit. 3

Outdoor air Optimum ventilation with Flexit SL4 R Exhaust air Supply air Clean, fresh air all year round The rotor unit offers stable operation throughout the year. The rotor technology copes effortlessly with icing and refreezing. This is particularly important in the Nordic countries with their cold climatic conditions. High efficiency energy savings The rotor unit has a high efficiency and recovers up to 80% of the heat from the air extracted from the home. The high efficiency ensures that a high proportion of the energy used for heating the ventilation air is recovered while still providing the desired ventilation in the home even in the cold season. Energy consumption Flexit SL4 R can be supplied with standard fans (AC) and low-energy fans (EC fans). EC fans have extra low energy consumption and ensure that the units are in readiness for future strict energy consumption requirements which will particularly focus on SFP (Specific Fan Power). The SFP value informs how efficiently a fan is able to transport the air. Extra heating required only in severe cold The rotor unit has a high efficiency and meets all the heating requirements for the ventilation air for most of the year. The heating batteries are dimensioned to cover heating requirements for ventilation air all year round, even when outside temperatures are very low. There is a choice between electric or water-based supplementary heating. For units with water-based supplementary heating, a water battery is provided for external installation in the duct. Automatic summer operation The rotor unit has an electronic control that automatically switches the recovery function off/on in accordance with the outside temperature. This gives much simpler operation than, say, a plate heat exchanger, which involves use of a summer cassette. Cleaning sector Simpler installation without a drainage outlet The rotor technology does not require condensation drainage. The moisture in the extract air follows the air out of the house in the exhaust duct. As there is no need for a drainage outlet, this means simpler installation and lower installation costs, plus great freedom when it comes to locating the unit. Area of use The unit is particularly well suited to flats and small detached houses. The unit can be located in many different areas, for example in an outhouse, utility room, passage or loft. The unit can be installed vertically as a cabinet model or horizontally, for example in a loft. l/s 0 20 40 60 80 400 300 200 230V Extract air Basic sketch of rotor operation Heat from the extract air passes through the rotor material to the supply air feeding the home. To prevent contaminated air entering the supply air, the rotor has a cleaning sector. Designed for modern homes Flexit SL4 R is in white lacquer with rounded front door. The unit has been constructed for installation in a utility room, outhouse, technical room or loft. 4 100 Pa 0 190V 170V 150V 120V 105V 85V 60V 60V 85V 150V 190 170V 120V 105V 70dB(A 60dB(A) 65dB(A)

Flexible installation The design of the unit permits many different variations of duct arrangement or locations in a home. The unit is designed for installation in utility rooms, outhouses, lofts or other suitable rooms. The unit can be supplied in left or right versions (exhaust nozzle to the left or right) depending on what is most convenient for duct location. The advantage of rotor technology is that no condensation water is formed and connection to a drainage outlet is unnecessary. In wet rooms the unit must be located in zone 3 (minimum 0.6m from the edge of the bath and 1.2m from the shower head). Wall installation as a cabinet model Flexit SL4 R is ideal for wall installation as a cabinet model. For example the unit can be mounted in a wet room over a hot water heater or in conjunction with a wall cupboard. (Fig. 1). Loft installation Flexit SL4 R has a chassis insulated for condensation and heat loss, which means that it can be installed in cold lofts. (Figs. 2a and b) Fig. 2a NB Mounting according to fig. 2a requires adjusting the nailing strip for hanging (see installation instructions). Fig. 1 Fig. 2b Additional floor panel Yellow Additional insulation Insulation. Mounting according to fig. 2b requires the use of the prescribed underlay (see installation instructions) to avoid vibration noise. 5

Flexible duct connection The duct connections can be installed in different combinations, depending on what is most suitable in relation to the building: Traditional top connection of ducts (Fig. 1, page 5). Outdoor air and extract air ducts on one side and supply air and exhaust air ducts on the other side (Fig. 3) All duct connections on one side of the unit (Fig. 4) The extract duct can be connected to both of the short sides in the case of shorter ducts (Fig. 5). All duct connections on one side of the unit plus an extra extract duct on the other side (Fig. 5). Extract air, supply air and exhaust air ducts on one side and outdoor air on the other side of the unit (Fig. 6) The outdoor air duct and the extract duct can if desired easily be joined to one of the short sides of the unit (top and bottom). External connection of a kitchen hood The unit can be connected to an external kitchen hood. A separate duct connection provided as standard on the unit is used for the external kitchen hood. During cooking, the extract air is led from the cooker hood round the rotary heat exchanger. The cooker hood is supplied separately and is installed on site. There is a choice between slimline models, built-in hoods and ventilator cabinet models. Ask for information on our cooker hoods. The Building Regulations recommend permanent ventilation in the kitchen. The appropriate ventilator should be located in the ceiling or wall. The louvres in the cookerhood must close when not in use. Fig. 3 Fig. 4 Fig. 5 Fig. 6 External connection of cooker hood Explanation of symbols 6

Product Description Basic settings The unit has two basic setting switches, one for supply air and one for extract air. The unit can be set to 120, 150 or 170 Volts on both fans at normal speed. (Flexit SL4 R is supplied from the factory with a setting of 150 V. See Ventilation data documentation for the correct setting.) To achieve further adjustment ranges, it is necessary to switch over directly on the transformer. 120 volt 150 volt 170 volt Flexit SL4 R with rotating recovery system. System description The unit is designed to provide optimal air comfort combined with low energy consumption in the home. The heated used indoor air is sucked out via the extract valves in the kitchen and wet room, then passes through a filter and is fed into the unit s rotary heat exchanger, after which it is expelled from the house via a roof hat or wall outlet (combibox). The outdoor air is introduced into the unit via an outdoor air intake, is filtered, continues through a rotaryheat exchanger where it takes on the heat from the extract air. The electronically controlled supplementary heating battery ensures a comfortable supply air temperature in the event of especially cold weather. After passing through the unit, the supply air normally flows through sound absorbers before entering the home through the supply air valves fresh, clean and at the appropriate temperature. Flexit SL4 R has an electronic control system which is run from a separately mounted control switch, CI 50. Installation The rotor units do not create condensation water. This makes installation simpler, as no drainage outlet is required. Locating the unit is more flexible as no account needs to be taken of distance from the drain. Design The unit s outer cabinet is in white-lacquered sheet steel. The inner cabinet is in galvanised sheet steel with 15 mm of condensation insulation. The front door is in plastic to reduce weight and to facilitate inspection and service. The door is rounded in shape and opens/closes with press buttons. Duct connections The connection dimension is a 160 mm dia. nipple. This is a flexible solution as it includes moveable connecting pieces while blind flanges are used to seal the duct outlets not in use. These are locked with screws during installation (Fig. 7). The unit is available in right or left versions. Fig. 7 Rotating recovery system Flexit SL4 R has an efficient rotating recovery system. To guard against air flows contaminating each other the recovery system is fitted with a cleaning sector. In addition both the exhaust air and the supply air are filtered so no contamination will come into contact with the rotor materials. 7

Temperature adjustment The unit is supplied with an electronic temperature sensor which must be mounted in the supply air duct. The desired supply air temperature is set on the control panel and the temperature is maintained by the unit s rotating recovering system and supplementary heating battery. Fans Flexit SL4 R is fitted with single-suction F-wheel radial fans. The fans have a low noise level and a high capacity, even in the case of long ducts. The cover over the fan can be removed by pressing the catches on the lower edge. The fan can be removed from its track. The motor and fan blades are removed by unscrewing the 4 screws in the round motor plate and carefully pulling the motor out of the motor housing. Heating element electric or waterbased To ensure the supply air has the correct comfort temperature and does not feel like a cold draught, the units are fitted with an electronically controlled supplementary heating element or water-basedheating battery. This is switched on when the supply air temperaturefalls below the set level and produces the necessary temperature increase. supplied. The supply air temperature is maintained by means of the high-efficiency heat recovery system in the rotor. The rotor is controlled according to the required supply air temperature. If this cannot be maintained by the rotor alone, the supplementary heating battery automatically cuts in as required. In the warm part of the year, when heating requirements are minimal, the rotor stops, thus avoiding heating up the supply air. Using the CI 50, the fans can be set to three speeds and the rotor/heating can be activated. The panel has pilot lamps showing the speed selected and whether the heating sequence has been activated. A lamp gives warning of fire/overheating and indicates when the filter should be changed. Fan speeds The desired speed is selected on the unit s control panel. CI 50 A forced air flow is obtained either by altering the pressure fall in the duct network by operating the extract ventilator with pull cord or similar, or by increasing the fan speed to maximum. Summer operation The rotating heat exchanger is electronically controlled and controls the supply air temperature. During the warm part of the year, the recovery function is switched off automatically when not required. A summer cassette is therefore not necessary. Filters The unit is fitted with supply air and extract air filters in the F7 class. The filters can be replaced easily without the use of tools. The rotor unit requires regular filter replacement (1-2 times a year) to ensure clean, fresh air and problemfree operation. Control The Flexit SL4 R is fitted with electronics which control the unit automatically via a circuit board. A CI 50 control panel with a 12 m signal cable and ISDN plug for simple, flexible installation of the control panel is 8

New control system CI 50 The new Flexit SL4 R is also accompanied by a newly developed automatic control system - CS 50, which consists of the control panel CI 50 and the motherboard CU 50. The control panel has a modern design for wall mounting. It is easy to control the unit from the panel, using clearly marked push buttons. Air flow and forced air ventilation, for example when taking a shower, and the desired air changes can all be controlled from the panel. The desired supplementary heating can be adjusted, and a lamp will light when the heating is on. A lamp will also light when the filter needs changing. Position 2 is for normal operating ventilation. This is the position for daily operation. Position 1 is used when not as much ventilation as normal is required. Position 3 is used when there is a need for extra ventilation in wet rooms or the whole house, and is used during and for a while after showering, for example, or clothes drying. As standard, the CI 50 is supplied for flush wall mounting. In this case a double Elko-type wall box must be used. A surface mounted wall box to take the control panel can be supplied as an accessory. CI 500 A separate control panel, CI 500, is available with timer function for automatic timed control of the unit. See list under Accessories. An extra forced air/control switch, CI 50, for installation near a shower, for example, can be supplied as additional equipment. 1 4 3 2 8 10 12 5 6 7 11 9 1. Indicator, alarm 2. Indicator, speed 1 3. Indicator, speed 2 4. Indicator, speed 3 5. Indicator, filter change 6. Indicator, supplementary heating activated (heating element) 7. Indicator, heating Off/On 8. Button, higher fan speed 9. Button, lower fan speed 10. Button, lower supply air temperature 11. Button, higher supply air temperature 12. Button, forced air 13. Indicator, shows set temperature from 15-25 C 13 9

Accessories Filter set (F7) for extract and supply air Art. no. Type 12336 Filter set, F7 09380 Additional forced air/control switch 13750 Brasserie-E white 13751 Brasserie-E steel 13616 Fondu-E Slimline 13626 Bistro-E, built-in cooker hood External water battery with control system Surface-mounted box CI 500, control panel with timer function Extra forced air and control switch Control panel, CI 500 Cooker hoods for external connection Brasserie-E white Fondue-E Brasserie-E, steel Bistro-E Flexit SL4 R Art.no. Type 14020 SL4 REL AC left mod with electric battery and AC fan 14021 SL4 RER AC right mod with electric battery and AC fan 14022 SL4 RWL AC left mod with water battery and AC fan 14023 SL4 RWR AC right mod with electric battery and AC fan 14024 SL4 REL EC left mod with electric battery and EC fan 14025 SL4 RER EC right mod with electric battery and EC fan 14026 SL4 RWL EC left mod with water battery and EC fan 14027 SL4 RWR EC right mod with water battery and AC fan 10

Technical data SL4 RE SL4 RE EC SL4 RW SL4 RW EC Rated voltage: 230 V/50 Hz 230 V/50 Hz 230 V/50 Hz 230 V/50 Hz Fuse: 10 A 10 A 10 A 10 A Rated current, total: 5.4 A 4.4 A 1.5 A 0.5 A Rated power, total: 1235 W 1005 W 335 W 105 W Rated power, electric battery: 900 W 900 W - - Rated power, fans: 2 x 165 W 2 x 50 W 2 x 165 W 2 x 50 W Fan type: F-wheel F-wheel F-wheel F-wheel Fan motor control: Transformer Transformer Transformer Transformer Max. fan speed: 2230 rpm 1800 rpm 2230 rpm 1800 rpm Automatic control standard: CS50 CS50 CS50 CS50 Filter type (SUP/EXTR): F 7/F 7 F 7/F 7 F 7/F 7 F 7/F 7 Filter dimensions Supply air (W x H x D): 350x185x50 mm 350x185x50 mm 350x185x50 mm 350x185x50 mm Filter dimensions Extract air (W x H x D): 350x185x50 mm 350x185x50 mm 350x185x50 mm 350x185x50 mm Weight: 47 kg 47kg 47 kg 47 kg Duct connection: Dia. 160 mm Dia. 160 mm Dia. 160 mm Dia. 160 mm Height: 700 mm 700 mm 700 mm 700 mm Width: 598 mm 598 mm 598 mm 598 mm Depth: 450 mm 450 mm 450 mm 450 mm AC-fan: Normal speed set at factory to 150 V EC-fan: Normal speed set at factory to 7 V Symbols Used This product has a number of symbols that are used to label the product itself and in the installation and user documentation. Here is an explanation of some of the commonest symbols: Flexit SL4 R, right mod Flexit SL4 R, left mod Cooker hood Cooker hood Our products are subject to continuous development and we therefore reserve the right to make changes. We also disclaim liability for any printing errors that may occur. 11

System sketch Extract air Supply air Outdoor air Exhaust air FI2 M1 EB1 F10 F20 FI1 M2 B1 Supply air temperature sensor EB1 Heating element F10 Overheating thermostat, MANUAL RESET F20 Overheating thermostat, AUTOMATIC RESET FI1 Supply air filter FI2 Extract air filter M1 Supply air fan M2 Extract air fan HR-R Rotary wheel-type heat exchanger M4 Rotor motor K Cooker hood (accessory) HR-R M4 455 455 107 107 598 128 Dimensioned Drawing Shown as right version 320 Dimensions in mm THE LEFT MODEL IS INVERTED 107 107 598 Ø125 128 320 700 455 107 107 598 Ø125 Cooker hood 700 299 299 12 0 0 700 128 320 Ø125 Shown from below 299 299 320 320 299 299 320 320 Shown from above Front

Capacity diagram SL4 R W/E (AC-fan) (measured with F7 filter) Supply air side Air flow rate in l/s l/s 0 20 40 60 80 100 400 200 Contact resistance in Pa 300 200 100 Pa 0 150 100 50 0 W Power consumption in Watt m 3 /h 0 100 200 300 400 Pa Air flow rate, m 0 3 /h - Correction factor pressure Extract air side Air flow rate in l/s 0 Contact resistance in Pa Pa W Power consumption in Watt m 3 /h 0 100 200 300 400 Pa Air flow rate, m 3 /h - Correction factor pressure 0 Sound Data is given at sound power level LwA in the capacity diagrams and is corrected with the table below for the various octave bands. Radiated noise produces Lw in the various octave bands and total LwA. Radiated noise is calculated by taking the noise value from the supply air table and deducting the total value from the correction factor table. Correction factors for Lw Hz 63 125 250 500 1000 2000 4000 8000 LwA Supply air 3 1 2-1 -7-11 -18-31 Extract air 10 8 5-2 -11-19 -30-48 Radiated -55-43 -35-36 -33-31 -40-50 -27,1 Temperature efficiency Efficiency is expressed as component efficiency and unit efficiency. Component efficiency (theoretical efficiency of rotor) is 83-85% at 250-200m 3 /h. Unit efficiency (measured efficiency of whole unit, including losses and other factors) is approx. 75% at 200m 3 /h. 13

Capacity diagram SL4 R W/E (EC fan) (measured with F7 filter) Supply air side Air flow rate in l/s 0 Contact resistance in Pa Power consumption in Watt Pa W m 3 /h 0 100 200 300 400 Pa Air flow rate, m 0 3 /h - Correction factor pressure Extract air side Air flow rate in l/s 0 Contact resistance in Pa Power consumption in Watt Pa W m 3 /h 0 100 200 300 400 Pa Air flow rate, m 3 /h - Correction factor pressure 0 F5-filter Sound Data is given at sound power level LwA in the capacity diagrams and is corrected with the table below for the various octave bands. Radiated noise produces Lw in the various octave bands and total LwA. Radiated noise is calculated by taking the noise value from the supply air table and deducting the total value from the correction factor table. Correction factors for Lw Hz 63 125 250 500 1000 2000 4000 8000 LwA Supply air 3 1 2-1 -7-11 -18-31 Extract air 10 8 5-2 -11-19 -30-48 Radiated -55-43 -35-36 -33-31 -40-50 -27,1 Temperature efficiency Efficiency is expressed as component efficiency and unit efficiency. Component efficiency (theoretical efficiency of rotor) is 83-85% at 250-200m 3 /h. Unit efficiency (measured efficiency of whole unit, including losses and other factors) is approx. 75% at 200m 3 /h. 14

11/2006