RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

Similar documents
Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

MVX-Series Diesel Engine Air Shut Down Valves

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

Gas Turbine Fuel Control Valve

MVX-Series Diesel Engine Shut Down Valves (Cable Operated Closure/Integral Reset Lever Types)

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION & MAINTENANCE

167D Series Switching Valves

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

World proven safety solutions for diesel engines

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

API Marine. BMS Presentation. Ballast Measurement Systems

V47 Series Temperature Actuated Modulating Water Valves

Commercial Gas Furnace Upflow

SELECTION, APPLICATION & MAINTENANCE

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

AMF112 Instruction Manual

Diesel Engine Exhaust Spark Arrestors Selection, Application and Maintenance

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

AMF112 ( <00>) 13mm (1/2 in.)

SELECTION, APPLICATION AND MAINTENANCE

SAN25 ( <00>)

Signature and ISX CM870 Electronics

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Hydraulic Control Solutions

Butterfly Valves PN 6/10/16 for flanged connection

6 Crankcase Ventilation

System 8. ü ( System 8

Solenoid Valve Island Type 3965

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Spare Parts Program. Parts, Consumables & Accessories superproductsllc.com

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

POLE MOUNT SYSTEM-3 INSTALLATION

Baumann Little Scotty Bronze Control Valve

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Electro-Pneumatic Bus Door Control Mechanism

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

ARB AIR LOCKER Air Operated Locking Differentials

Pipe Cutting and Beveling Clamshells

Model 43AP Pneumatic Controller, Style B

RT100 ROUGH TERRAIN CRANE DATASHEET - IMPERIAL. Features:

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Fire Pump Plan Review March 2010

Machine bolt shut-off nozzle type BHP pneumatically or hydraulically controlled

Manual piston sampler...m 11

Hose Clamps & Fittings

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

VOYAGER 570G. 744A Sprayer Control

WHOLESALE DIRECT INC WEST 65TH STREET

MONITOR SECTION INDEX

Baumann Way Bronze or Stainless Steel Control Valve

Toroidal Conductivity Sensor

Baumann Flexsleev Sanitary Control Valve

61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

POLE MOUNT SYSTEM EX-3 INSTALLATION

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

Air/Vacuum Valves. Removal of Air from Pipelines. Allow the Entry of Air into Pipelines. Application:

Model 1210C Battery Powered Pump Shown. Description

Explosion-Proof Electric Unit Heaters

TorqPlus TM Electric Valve Actuators and Controls

Wildland Fire Remote Monitor

Spray Height Control System

PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited

ThermoSorb Desiccant Dryers

New 27 hp 2 Cylinder Liquid-Cooled Engine

NITROUS TRANSFER PUMP INSTRUCTIONS

Diesel Engine Driven Generators Page 1 of 6

Worcester DS/DM Series UltraSwitch Switch box

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8

Selecting TEMA Type Heat Exchangers

VW Caddy W INSTALLATION INSTRUCTIONS

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Speed Control Relays SX2

Control blocks for two-hand start ZSB

The Axial Flow Valve. Class 300/ SERIES

OPTIMASS 6000 Technical Datasheet

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Terminal Boxes Series 8146

Precision Solenoid Valves

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Thermometer in stainless steel with capillary and switch contacts

Utility Distribution Systems

In-Line Electronic Flow Switches

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Cooling Capacity CFM in. w.c. (125 Pa)

Volkswagen Golf > VW Rabbit GTI 2006->

REMOVAL AND INSTALLATION

Check Valves & Actuated Valves

C18 ACERT Fire Pump Tier bkw/ rpm

ZF 301 A. Marine Propulsion Systems

Transcription:

Diesel Engine Air Intake Shutoff Valves Model RDS1 Swing Gate Valve Overview If flammable gas or vapor is present in the atmosphere surrounding a diesel engine, it can be ingested into the engine and become an ungoverned fuel supply. This ungoverned fuel can result in runaway engine overspeed, potentially leading to dangerous mechanical failure or an explosion. The Roda Deaco RDS1 Swing Gate Valve is a compact air intake shutoff valve that provides emergency overspeed shutdown of a diesel engine. The RDS1 Swing Gate Valve can be triggered to close, which starves the engine of air and shuts down the engine. RDS1 - Electrically Actuated Valve Typical Applications Drilling rigs (onshore & offshore) Drilling support equipment Well servicing equipment Refinery support equipment Bulk haulers and tankers Generator sets Mining equipment Construction equipment Emergency response vehicles and equipment Aircraft support equipment Work boats Barges Agriculture equipment Key Features and Benefits Easy to install and maintain Lightweight, compact design Corrosion resistant aluminum and stainless steel construction Used in manual and automatic actuation systems: - Electric - Mechanical Wide variety of installation kits for most installations RODADEACO by AMOT DS-RO-RDS1-0809-Rev3 www.rodadeaco.com

Operation The Model RDS1 is a compact swing gate design air intake shutoff valve available with either electric or mechanical actuation. Actuation of the Model RDS1 closes the valve s sealing element which shuts off intake air flow into the engine. The RDS1 can be used in fully automatic or manual shutdown systems. Refer to the Roda Deaco Selection Guide to determine the appropriate system and actuation for your application. Valve Specifications Standard materials: Valve body Aluminum Gate arm Sealing element Seals Solenoid housing Plated steel Floating phenolic disc Silicon standard Plated steel Net weights Manual actuated 2.5 lbs 1.2 kg (incl actuator): Standard solenoid actuated 3.5 lbs 1.6 kg Intake air temperature range: Standard valve -40 F to 221 F -40 C to 105 C Ambient air temperature range: Standard valve -40 F to + 257 F -40 C to +125 C Electric solenoid Standard solenoid actuation: Nominal 12 VDC power requirement 70.5 amp pull in 0.9 amp hold Nominal 24 VDC power requirement 36.4 amp pull in 0.5 amp hold Cycle rate 6 activations per minute Manual actuation: Mechanical pull to release 15 lbs 67 Newton page 2

Valve Selection The RDS1 Swing Gate Valve can be used in applications where the air intake line is 1 /2 to 2 1 /2 inches (15-65 mm) in diameter. The RDS1 Swing Gate Valve can be mounted in vertical or horizontal orientations and airflow through the valve can be in either direction. When specifying the valve, note the clearance requirements for the valve with the geometry of the engine and intake line for your application. Front view of valve To accommodate the installation requirements for the wide variety diesel engine applications, the size and attachment types on the valve body and the valve cover are specified separately. The valve attachments are available in several styles including: hose, O-ring, flange, and engine specific attachment. Profile view of valve Valve Size Standard Attachment Sizes 1 1 /2 38 mm 1 5 /8 41 mm 1 3 /4 44 mm 1 7 /8 48 mm 2 51 mm The RDS1 Swing Gate Valve is available in several standard sizes for intake air lines ranging from 1 1 /2 to 2 inches (38 to 51 mm) in diameter. Standard sizes for hose and V-clamp attachments are listed to the left. Additional sizes are available to meet specific application requirements. page 3

Valve Selection Continued Valve Attachment Mechanism The hose attachment is the standard attachment mechanism. However, additional attachments are available including O-Ring, V-Clamp, Flange, and engine specific adapters. Examples are shown below. To accommodate the installation requirements for the wide variety of diesel engine applications, the size and connection types on the valve body and the valve cover are specified separately. Hose Attachment Uses sections of flexible hose and band clamps to attach the valve to intake line. Standard Hose x Standard Hose Extended Depth Hose x Extended Depth Hose V-Clamp Attachment Heavy duty V-style ring clamp used to clamp valve to metal intake lines. Several types of V-clamp connections are available. Male V Clamp x Female V Clamp Flat Face V Clamp x Standard Hose Female V Clamp x Male Notched V Clamp O-Ring Attachment Space saving single or dual O-Ring attachments are available. O-Rings are used to seal rigid air intake line connections. Exterior Single O-Ring x Exterior Single O-Ring Interior Dual O-Ring x Interior Dual O-Ring Dual O-Ring x O-Ring Receiver Cup Flange Attachment Flange attachments on the valve are available to secure the valve to the engine. Flange x Flange Interior Dual O-Ring x Flange Special Attachments Additional attachments are available on request. page 4

Valve Features Selection Valve Actuation Type Electric actuation The Diesel Engine Air Intake Shutoff Valve has two actuation methods: electric and mechanical. Please refer to the Roda Deaco System Selection Guide for complete descriptions of the systems to help determine the proper actuation required for your application. Electric Actuation The electrically actuated RDS1 is an energize-toclose valve. It operates using either 12 VDC or 24 VDC power. The valve will automatically reset after the engine stops and power is removed. The electrically actuated RDS1 valve is designed for use in the systems indicated below: pull cable mounting bracket Automatic Electric Overspeed RPM Detection with Manual Override Manual Electric System Mechanical Actuation Mechanical actuation The mechanically actuated RDS1 can be operated by using either a remote cable pull system or direct operator action on the valve. The mechanically actuated RDS1 is reset manually. The mechanically actuated RDS1 valve is designed for use in the systems below: Remote Cable Pull Actuated System Direct Actuated Valve Valve Intake Air Temperature Rating Temperature range Standard range -40 F to 221 F -40 C to 105 C The RDS1 Swing Gate Valve can be used on intake lines of naturally aspirated or turbo-charged engines where air intake line temperatures do not exceed 221 F (105 C) at the valve. Valve Feature Option Pneumatic Reset A pneumatic cylinder can be added to the valve to provide remote reset capability for mechanically actuated valves. page 5

Actuation Kits Actuation kits are provided with each system sold. The actuation kit contains hardware required to properly install and integrate the specified shutdown system into the diesel engine application. The kits, specific for each type of system and application, can include items such as: Electric Actuation Kit Electric Pneumatic Actuation Kit Voltage control module Relays Circuit breaker Toggle switch Cable with T-handle Manual Pneumatic Actuation Kit Manual Pull Cable Actuation Kit Installation Kits Simple Hose Kits Installation kits are also provided with each system sold. The installation kit contains the hardware required to facilitate the installation of the Air Intake Shutoff Valve into a diesel engine air intake line. Roda Deaco has hundreds of different installation kits designed to meet specific engine model and application requirements. The kits can range from hose with clamps to custom intake pipes, elbows, flanges, brackets, etc. Single Elbow Kit with Multiple Hose Double Elbow Kit Complex 3 Elbow Kit page 6

Dimensions Electrically Actuated Valve B A 8.00 (203) Clearance Dimensions A* B C D E 1.500 (38) 2.750 (70) 3.750 (95) 2.750 (70) 0.500 (13) C 1.750 (44) 2.000 (51) 2.625 (67) 2.500 (64) 3.625 (92) 3.500 (89) 2.625 (67) 2.500 (64) 0.375 (9) 0.250 (6) 1.00 (25) 3.250 (83) 4.20 (108) E 4.750 (171) D * Hose Attachment Size Inches (mm) Dimension in inches (mm) Mechanically Actuated Valve B A 6.750 (171) Clearance Dimensions A* B C D E 1.500 (38) 1.750 (44) 2.000 (51) 4.500 (113) 4.375 (110) 4.250 (106) 0.750 (19) 0.625 (16) 0.500 (13) 2.375 (60) 2.250 (57) 2.125 (54) 0.500 (13) 0.375 (9) 0.250 (6) C * Hose Attachment Size Inches (mm) 1.00 (25) D E 3.250 (83) 4.375 (111) Dimension in inches (mm) page 7

How to Order Please submit this form by email or fax: Email: orderdesk@rodadeaco.com Fax: (780) 469-6275 ORDERING INFORMATION SHEET Customer Information Application Contact Billing Contact Customer Name Customer Name Customer Title Customer Title Contact Number Contact Number Fax Number Fax Number Email Email Company Name Company Name Shipping Address Billing Address Application Information Please fill out this form to the best of your ability. Photos welcome Application Information Stationary Mobil Marine Equipment Application Quantity for this application Equipment Name Equipment Model Engine Information Make Model Year Serial/VIN No. Turbocharger and Intake Air Cooling Information Intercooler (Air to Air cooler mounted with engine radiator) No air cooling after turbocharger Aftercooler (liquid cooler in the engine) No turbocharger the engine is natural aspirated Air Intake Line Information: The air intake shutoff valve is usually installed at the inlet to the engine. Please provide the air inlet line information requested below. Number of Inlet lines Turbocharger Boost pressure Intake line air temperature (if known) Inlet Line Material: Metal Pipe: outside diameter Rubber Hose: inside Diameter Inlet Line or Elbow Part Number: Attachment mechanism of Air Intake Line to the inlet to the engine: Hose Standard Extended V-Clamp Flat face Female Male Notched O-Ring Internal External Receiver Cup Single O-ring Dual O-Ring Flange Round Square Trapezoid Other Number of Bolts Other (Please specify and include photos) Engine Overspeed Safety System Information Refer to the Roda Deaco System Selection Guide for information about the system listed below. Automatic RPM Overspeed Detection and Shutdown Systems with manual Override Electronic RPM Detection with Electric Actuated Valve and Electronic RPM Detection with Pneumatic Acutated Valve and Manual Override Manual Override System Voltage: 12 vdc 24 vdc System Voltage: 12 vdc 24 vdc Manual Actuated Systems and Valves Electric Actuation System Electric Switch with Pneumatic Valve System Voltage: 12 vdc 24 vdc System Voltage: 12 vdc 24 vdc Cable System Pneumatic System 10 20 30 Direct Manual Valve Additional Valve Features Proximity Switch Valve Position Indication (Available on Pneumatic Reset (Available on pneumatic and mechanical RDS2, RDS3, and RDS5 models) actuated valves) Roda Deaco Valve 3230-97 Street Edmonton, Alberta Canada T6N 1K4 Note that many engines are available in different configurations in different equipment. Some examples include: turbocharged, turbocharged with air to air intercooler, turbocharged with a liquid aftercooler on the engine, twin turbocharger arrangements and naturally aspirated engines. Roda Deaco has a broad array of fully automatic and manual shutoff systems. The systems have sensors, switches, valves, actuation kits and hundreds of different installation kits available to facilitate installation of systems. When ordering, please complete the Roda Deaco Ordering Information form shown on the left. The form is available electronically on the Roda Deaco web site, www.rodadeaco.com, by contacting your local representative or contacting Roda Deaco Customer Service. See the back of this datasheet for contact information. Valve Model Code Valve Body Selection Valve Feature Selection Example Code RDS1-1750 HA 1750 HA - E1 L A Code Description Valve Family RDS1 Valve Body Side Attachment Size (additional sizes available) Valve Body Side Attachment Mechanism (additional attachments available) Valve Cover Side Attachment Size (additional sizes available) Valve Cover Side Attachment Mechanism (additional attachments available) Valve Actuation Type Inlet Air Line Temperature Valve Options Type RDS1 Swing Gate Bocy Attachment Outer Diameter Size - inches 1500 1.500 1 1/2 (38 mm) 1625 1.625 1 5/8 (41 mm) 1750 1.750 1 3/4 (44 mm) 1875 1.875 1 7/8 (48 mm) 2000 2.000 2 (51 mm) Body Attachment Mechanism HA Standard hose connection VA V-clamp EA V-clamp female MA V-clamp male Cover Attachment Outer Diameter Size - inches 1500 1.500 1 1/2 (38 mm) 1625 1.625 1 5/8 (41 mm) 1750 1.750 1 3/4 (44 mm) 1875 1.875 1 7/8 (48 mm) 2000 2.000 2 (51 mm) Cover Attachment Mechanism HA Standard hose connection VA V-clamp EA V-clamp female MA V-clamp male Actuator Type Mech M0 Mechanical Elec E1 12 volt solenoid E2 24 volt solenoid Inlet Air Temperature L -40ºF - 221ºF (-40ºC - 105ºC) Options A No Options B Pneumatic Reset (Mechanical Actuator Only) page 8

North and South America Europe, Middle East and Africa 3230-97 Street Edmonton Alberta T6N 1K4 Canada Tel +1 780 465 4429 Fax +1 780 469 6275 Email orderdesk@rodadeaco.com Western Way Bury St Edmunds Suffolk, IP33 3SZ UK Tel +44 (0) 1284 762222 Fax +44 (0) 1284 760256 Email info@amot.com 8824 Fallbrook Dr Houston TX 77064 USA Tel +1 (281) 940 1800 Fax +1 (713) 559 9419 Email sales@amotusa.com Asia Pacific Rm A308 Building A8 Jiahua Business Center 808 Hongqiao Road Shanghai 200030 China Tel +86 (0) 21 6447 9708 Fax +86 (0) 21 6447 9718 Email shanghai@amot.com RODADEACO by AMOT www.rodadeaco.com An ISO 9001 Registered Company The contents of this publication are presented for informational purposes. While every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. The purchaser and end user are responsible for analyzing all aspects of their application and using their own judgment in the final selection, use, and maintenance of the system and components. The purchaser and end user are also responsible for assuring that all performance, safety and warning requirements of the application are met. Roda Deaco, AMOT, Roper Industries, or any of their affiliated entities assume no responsibility for the selection, use, or maintenance of any product.