AMP Power Series Connectors



Similar documents
Universal MATE-N-LOK Connector System

USA: 866.LAWSON4U ( ) Canada: lawsonproducts.com. Electrical Industrial and Fleet Solutions

How To Build A Powerline Box Powerline Generator

Quick Reference Guide 1.5 mm AMP Mini CT Connector Series

Quick Reference Guide Euro Style Terminal Blocks

Anderson Power Products

Quick Reference Guide AMP CT Connector Series

Quick Reference Guide 1.5 mm AMP Mini CT Connector Series

TRAIL CHARGER BASED CHARGING SOLUTIONS

ELECTRICAL CONNECTORS

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

Glenair Military and Industrial Power and Signal Connectors

CoolWave r 2 Phase Control Board and Cable Replacement Kits

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N

Charging connections for electric vehicles

Our full line of JS Popper test products enables you to monitor circuits without taking them offline

CONEC SnapLock. 1 Introduction

This product can be assembled to the baseplate maintaining 5 mm center-to-center spacing. Thus any number of poles can end-to-end stack.

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

FTTX Solutions FDH 3000 Cross-Connect

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

FANG 24T, 26T and 28T -EU

HM-W536 Install Guide

Universal MATE-N-LOK Connectors

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

USB 3.0 Cables. Color. Black Black Black Black Black Black Black Black Black Black

Assembly Instruction CAI- Connector with universal Endbell

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

19-PIN. PLS 19-pin connector series. Features: SOLDER TYPE CRIMP TYPE PLS-5219LM PLS-5219CLM PLS-5219CLF PLS-5219LF PLS-5219SM PLS-5219CSM

CutMaster Major External Replacement Parts

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

WIRELESS STATUS MONITOR

Massage, Heat & Air Systems

400 Series - Mini USB Buccaneer

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Cell Phone Charging Purse

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

K-39/K-39B. Drain Cleaning Machine. Ridge Tool Company/Elyria, Ohio, U.S.A.

Server Racks, Cabinets, and Workspace Solutions

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Directory chapter 04

Forklift/Pallet Jack Scales Table of Contents

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

TELEPHONES Accessories. Phones. parts. Keypad Telephones Auto Dial. Courtesy Inmate Telephones. Hands-Free Telephone. Catalog.

Part Name/Description Part Number Quantity. Power Cable

Mini USB and USB 2.0-IP67 Connector System

multi-axis system ROBOTRAX cable 3D cable carrier system carrier

SMS - Qikmate. Performance characteristics

Current Monitoring Kit QUICK START GUIDE

CutMaster Major External Replacement Parts

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

BATTERY CONNECTOR # DESCRIPTION (1 HOUSING & 2 CONTACTS) HOUSING # CONTACT KIT #

Software... pg 3 File Maintenance Training

EZ-Steer Assisted Steering System

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

Selecting and Installing a Tripp Lite Battery Backup System for Your Sump Pump

SPECIFICATIONS. S&C Switch Operators Type PM SPECIFICATION BULLETIN For Field Retrofit on Manual PMH, PMS, and PME Pad-Mounted Gear

Terminal Block WR-TBL

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

INSTALLATION INSTRUCTIONS

Current Monitoring Kit

SERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N &

Emergency Response. Prepared for Fire Service, Law Enforcement, Emergency Medical, and Professional Towing Personnel by American Honda Motor Co., Inc.

ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L

Passive Anti -Theft System (PATS) Diagnostic Flowcharts. Issue: This bulletin provides diagnostic information for the Passive Anti-Theft System.

Section M POWER LIFTS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

ATS - Automatic Changeover


RoHS. Heavy Duty Sealed Connector Series (HDSCS) Ready. for Industrial & Commercial Vehicles

Accessory Name Part Number Description

MUSTANG II IFS COMPLETE PARTS PACKAGE

Poor quality welds Machine downtime High maintenance costs Lost revenue

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

MCR1900 Media Converter 19-Slot Chassis

Wire, Cable, and Battery Accessories Product Catalog

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Schauer 3210 Wasson Road Cincinnati, Ohio For More Information Or Call VOLT (8658).

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

STUDY OF CELLPHONE CHARGERS

BLUETOOTH WIRELESS COMMUNICATIONS

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

08. SEK IDC CONNECTORS

13 Watt PORTABLE SOLAR POWER KIT

EASYLIFT ECONOMY DRUM TRANSPORTER

LHD LINEAR HEAT D ETECTIONN

EPIC CIRCON M23 Series Circular Signal Connectors

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

Alternator Identification

mpm DIN CONNECTORS

GENUINE PARTS INSTALLATION INSTRUCTIONS

Replacing the Gateway M675 Keyboard

FLOOR INDICATORS CATALOGUE 2007

CHAPTER 5 PARTS. This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation.

SECURITY SYSTEM SMART SIREN KIT

Transcription:

May 3, 2011 2011 Tyco Electronics Corporation. All Rights Reserved. TE Connectivity, TE Connectivity (logo) and TE (logo) are trademarks. Other logos, products and/or Company names might be trademarks of their respective owners..

Single-pole and 2-pole power connectors Available in nine series with current ratings from 15 to 275* amps and voltage ratings up to 600 volts (AC or DC); equivalent to competition Contact wire range from 12 AWG to 300 MCM Contacts available Cold-headed contacts for Series 50, 75, 120, 175, 180 and 350 Connectors Stamped and formed contacts for Series 15, 30, 45, 50 and 75 Connector Integral stainless steel locking spring in housing for contact retention and mating force *Tested to 275 amps with 4/0 AWG wire page 2 / May 3, 2011

Hermaphroditic/genderless housings reduce inventory Housings are color-coded Accessories (not used with every series): Reducing Bushings Mounting Clamps Mounting Wings Retaining Pins Battery Handle Dust Cover Strain Relief Cable Clamps Plastic Handle Outer Shell Housings (black) accept Single-Pole Housings to form 2- thru 10-Pole Connectors Charger Key Spacers page 3 / May 3, 2011

Series 15/30/45 Single-pole housing Built-in interlocking features (dovetails) allow stacking and wire routing Rated at 15 to 40 A, 600 V (AC or DC) 15 A contact for 16-20 AWG wire 30 A contact for 12-16 AWG wire 45 A contact for 10-14 AWG wire Accessories: Mounting wings, retaining pins, spacers, mounting clamps, cable clamp kits and outer shell housings (accept single-pole housings) Housings can be Stacked page 4 / May 3, 2011

Series 50 2-pole housing Rated at 50 A, 600 V (AC or DC) Wire size 6-12 AWG Choice of cold-headed or stamped and formed contacts Accessories: Reducing bushings, strain relief cable clamps, dust cover, and plastic handle Optional special Finger Probe Resistant (FPR) version of housing available page 5 / May 3, 2011

Series 75 Single-pole housing Built-in interlocking features (dovetails) allow stacking and wire routing Rated at 75 A, 600 V (AC or DC) Wire size 6-12 AWG Choice of cold-headed and stamped and formed contacts Accessories: Mounting wings, retaining pins, mounting clamp sets, and reducing bushings Housings can be Stacked page 6 / May 3, 2011

Series 120 (Single-Pole) Built-in interlocking features (dovetails) allow stacking and wire routing Rated at 120 A, 600 V (AC or DC) Wire size 2-6 AWG Cold-headed contacts Accessories: Retaining pins, reducing bushings, and mounting clamp sets page 7 / May 3, 2011

Series 120 (2-Pole) Rated at 120 A, 600 V (AC or DC) Wire size 2-8 AWG Cold-headed contacts Accessories: Reducing bushings, retaining pins, and mounting clamp sets page 8 / May 3, 2011

Series 175 2-pole housing Rated at 175 A, 600 V (AC or DC) Wire size 4-1/0 AWG Cold-headed contacts Accessories: Reducing bushings, battery handle, cable clamps and dust cover page 9 / May 3, 2011

Series 180 Single-pole housing Built-in interlocking features (dovetails) allow stacking and wire routing Rated at 180 A, 600 V (AC or DC) Wire size 4-1/0 AWG Cold-headed contacts Accessories: Retaining pins, reducing bushings, and mounting clamps With Mounting Clamps page 10 / May 3, 2011

Series 350 2-pole housing Rated at 275* A, 600 V (AC or DC); equivalent to competition Wire size 1/0-300 MCM Cold-headed contacts Accessories: Reducing bushings, battery handle and cable clamps page 11 / May 3, 2011

Typical Applications Include: Power Supplies AC/DC Power Supply AC/DC Power Converter UPS Backup Power Units Portable Power Supply AC Power Cord Power Junction Boxes Charging Systems Rechargeable Battery Applications page 12 / May 3, 2011

Typical Applications Include: Material Handling Equipment Fork Lift Trucks Electrical Vehicles Golf Carts Sweepers Electric Cars Medical Wheelchairs Industrial Equipment Industrial Vacuum Cleaners page 13 / May 3, 2011

Typical Applications Include: Power Distribution Modules Floors Under Counters Office Furniture Modular Office Panels Telecommunications Telecom Rectifier Telecom Power Plant page 14 / May 3, 2011

Features Color-coded connector housings Mechanical keys (2-pole version only) Hermaphroditic/genderless housings Single-pole housings are side-toside and top-to-bottom stackable Cold-headed and stamped & formed contacts Benefits Color designates recommended application voltage Helps prevent two different voltage color-coded housings from mating Reduces inventory Flexibility of application with minimum part number inventory Wire range flexibility and application cost page 15 / May 3, 2011

Application Tooling PICO tools (recommended for cold-headed contacts) Mechanical hand tool (for loose piece) Heavy-duty pneumatic tool (for loose piece) Heavy Duty Mini-applicators for the AMP-O-LECTRIC Model K bench machine for stamped & formed contacts Applicator PN 1385664-2 (6-8 AWG) Applicator PN 1385663-2 (10-12 AWG) Taped version of the cold-headed contacts is available page 16 / May 3, 2011

Resources Catalog 1308885 Full Line Product Info. Kit 1309280 - Series 50 Flyer 1654450 - Series 15/30/45 Flyer 1309169 - Series 50 Flyer 1654219 - Series 50 Finger Probe Resistant (FPR) Flyer 1309336 - Series 75 Single-Pole Flyer 1654458 - Series 120 Single-Pole Flyer 1309414 - Series 120 2-Pole Flyer 1654204 - Series 175 2-Pole Flyer 1654512 - Series 180 Single-Pole Flyer 1654205 - Series 350 2-Pole page 17 / May 3, 2011