Experiment 5. Lasers and laser mode structure



Similar documents
Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Lab 9: The Acousto-Optic Effect

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

Alignement of a ring cavity laser

- thus, the total number of atoms per second that absorb a photon is

Using light scattering method to find The surface tension of water

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Acousto-optic modulator

THE BOHR QUANTUM MODEL

Module 13 : Measurements on Fiber Optic Systems

Lab 1: The Digital Oscilloscope

Synthetic Sensing: Proximity / Distance Sensors

FTIR Instrumentation

Laser Gyroscope. 1) Helium-Neon laser

INTERFERENCE OF SOUND WAVES

Introduction to Fourier Transform Infrared Spectrometry

ELECTRON SPIN RESONANCE Last Revised: July 2007

Creating a Cavity-Dumped Helium Neon Laser

The Sonometer The Resonant String and Timbre Change after plucking

Blackbody Radiation References INTRODUCTION

v = λ f this is the Golden Rule for waves transverse & longitudinal waves Harmonic waves The golden rule for waves Example: wave on a string Review

Electrical Resonance

Interferometers. OBJECTIVES To examine the operation of several kinds of interferometers. d sin = n (1)

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Experiment #5: Qualitative Absorption Spectroscopy

Experiment 1: SOUND. The equation used to describe a simple sinusoidal function that propagates in space is given by Y = A o sin(k(x v t))

A Guide to Acousto-Optic Modulators

INTERFERENCE OF SOUND WAVES

Lasers Design and Laser Systems

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.

Nuclear Magnetic Resonance (NMR) Spectroscopy cont... Recommended Reading:

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Interference. Physics 102 Workshop #3. General Instructions

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

RC Circuits and The Oscilloscope Physics Lab X

Experiment 8: Undriven & Driven RLC Circuits

Polarization of Light

Undergraduate Research Academy (URA) Cover Sheet

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Introduction to Diode Lasers

Data Acquisition Using NI-DAQmx

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

Experiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil

Waves - Transverse and Longitudinal Waves

Fraunhofer Diffraction

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

OPTICAL FIBERS INTRODUCTION

FIBER LASER STRAIN SENSOR DEVICE

Diffraction and Young s Single Slit Experiment

Introduction to Geiger Counters

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

A More Efficient Way to De-shelve 137 Ba +

A METHOD OF PRECISE CALIBRATION FOR PIEZOELECTRICAL ACTUATORS

Four Wave Mixing in Closely Spaced DWDM Optical Channels

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Atomic and Nuclear Physics

What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)

It has long been a goal to achieve higher spatial resolution in optical imaging and

APPLICATION NOTE AP050830

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

DIODE PUMPED CRYSTALASER

APPLICATION NOTE POLARIZATION MEASUREMENTS

Germanium Diode AM Radio

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

TOF FUNDAMENTALS TUTORIAL

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

O6: The Diffraction Grating Spectrometer

Physics 41 Chapter 38 HW Key

Fibre Bragg Grating Sensors An Introduction to Bragg gratings and interrogation techniques

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

Lab Exercise 1: Acoustic Waves

Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect

Experiment #12: The Bohr Atom. Equipment: Spectroscope Hydrogen and Helium Gas Discharge Tubes, Holder, and Variac Flashlight

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

Antenna Deployment Technical Brief

ULTRAFAST LASERS: Free electron lasers thrive from synergy with ultrafast laser systems

Upon completion of this lab, the student will be able to:

Experiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

Measuring of optical output and attenuation

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Experiment 5. Strain Gage Measurements

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

Diffraction of a Circular Aperture

Interferometric Measurement of Dispersion in Optical Components

Amplified High Speed Fiber Photodetectors

Gamma Rays OBJECT: READINGS: APPARATUS: BACKGROUND:

Lab E1: Introduction to Circuits

Dash 18X / Dash 18 Data Acquisition Recorder

Fundamentals of Photonics. (Course 1 of 8. Now under field test) EDITORS Arthur Guenther Leno S. Pedrotti Chandrasekhar Roychoudhuri.

ILLUSTRATIVE EXAMPLE: Given: A = 3 and B = 4 if we now want the value of C=? C = = = 25 or 2

4.3.5: High Temperature Test 3

Cathode Ray Tube. Introduction. Functional principle

Aesthetic Plus LASER TRAINING MANUAL FOR MEDICAL PROFESSIONALS. presents

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

Transcription:

Northeastern University, PHYS5318 Spring 2014, 1 1. Introduction Experiment 5. Lasers and laser mode structure The laser is a very important optical tool that has found widespread use in science and industry, from high resolution, ultra-fast spectroscopy, to precise, high power welding. In this lab, we will explore how lasers work and examine some of the details that make different laser appropriate for different tasks. Any laser starts with a gain medium. This gain medium, which can be solid, liquid, or gas, contains atoms or molecules with excited states that emit light over a range of wavelengths. The laser we will be exploring is the common Helium Neon laser, or HeNe. It is really the excited states of neon that are of interest. Neon is excited by an electrical discharge, which causes it to enter one of many high energy states. When the atom relaxes to a lower energy state, it emits light at several possible wavelengths. Neon emits at several wavelengths in the red, yellow, and green. Figure 1. Diagram of external cavity HeNe laser. For the gas to lase, a population inversion must be created, in which the gas contains more atoms in a specific high energy state relative to the low energy state. This is done by reflecting light of a specific wavelength back and forth across the gain medium using two mirrors, which causes stimulated emission of more radiation of the same wavelength. The region between the two mirrors is referred to as the laser cavity. This region is usually hidden from the users of a laser, but in our case we have an external

Northeastern University, PHYS5318 Spring 2014, 2 cavity, which allows us to adjust the parameters that determine the properties of the laser beam. 2. The external cavity HeNe laser On the optical table in 230 Dana you will find our HeNe laser. The sealed laser tube (do not touch it!) contains an appropriate mixture of helium and neon. The back mirror seals one end of the tube, while at the other end there is a window at an angle. This angle is referred to as the Brewster angle, which allows only one polarization to pass through. Thus, the output will be polarized light at the various wavelengths emitted when neon is excited, which looks pink. Outside the laser tube there is a small mirror mounted on a post. This is the output coupler, which reflects 99% of the light at the desired wavelength, 633 nm. The setup is shown in Figure 1. Do not touch the electrodes on the laser tube! They are high voltage! To turn on the laser tube, use the switch on the Melles Griot power supply. After a few seconds, the tube will begin to glow pink. Move the output coupler close to the Brewster window output of the laser tube. Adjust the micrometers on the output coupler to achieve lasing. This may take some time, but be patient and systematic. The effect when you see lasing will be very dramatic and cool. 3. Studying multiple spatial lasing modes. In addition to multiple modes at different laser wavelengths, multiple transverse spatial modes are also observed. These modes are designated by the number of transverse nodal lines in the x and y directions. Examples of this are illustrated in Figure 2. Adjust the length of the optical cavity, the size of the pinhole diaphragm, and the angle of the output coupler (using the two micrometers on its mount) and explore modes that you see. List the modes that you see and under what conditions you see them. Can you remove some Figure 2. Spatial laser modes and their designations. From Hecht, Optics, Addison- Wesley, 2 nd Edition.

Northeastern University, PHYS5318 Spring 2014, 3 modes by closing the pinhole? Which ones? 4. Using a scanning confocal interferometer to determine the cavity mode frequencies of lasers. The confocal interferometer is a useful device for studying the frequency content of lasers because it has very high finesse (200 or greater). The finesse is very sensitive to the alignment of the input light relative to the interferometer and the mirror spacing. The interferometer must be operated with the mirrors very close to the confocal spacing in order to get high finesse. Mirror sets are specified by the free spectral range corresponding to the proper mirror spacing. The mirrors in our interferometer are designed to operate with 2 GHz FSR. The FSR serves as a scale factor for the horizontal axis - the output repeats itself every FSR scanned. The resolution of the interferometer is given by the FSR divided by its finesse, so we should have a resolution of 10 MHz. The spacing of the mirrors can be changed using piezoelectric crystals (PZT) that change mirror spacing by a few wavelengths of light when a voltage is applied. The controller for the interferometer can apply a ramp voltage to the PZT to scan the interferometer. You can adjust the amplitude and frequency of the ramp. We will use this instrument to look at laser cavity modes. Please consult the SA Plus user manual for instructions on how to control and display the data from the interferometer. Laser cavity modes are determined by the cavity mirror spacing and curvatures. Modes are specified by a longitudinal mode number, which specifies the number of wavelengths that fit into one round trip at cavity center, and two transverse mode numbers that give the number of nodes in the two directions perpendicular to the cavity axis. These are the numbers shown in Figure 2. The longitudinal number is usually quite large, while the transverse numbers are usually less than 4. The transverse mode numbers can be reduced to zero by misalignment of the cavity or insertion of an aperture. The frequency of a particular cavity mode depends on all three mode numbers. Changing the longitudinal mode number by one changes the frequency by ν long = c 2L (1) The general case of transverse mode spacing is complex. The simplest case to consider is a symmetric cavity with identical mirrors. Changing either of the transverse mode numbers by 1 changes the frequency by ν trans = c πl tan 1 where L 2z R (2) z R = 1 2 L 2R L. (3) Our mirrors each have a radius of 45 cm.

Northeastern University, PHYS5318 Spring 2014, 4 To observe these modes, you must set up the confocal interferometer to display the laser spectrum on the digital oscilloscope. First, you must have the laser light aligned and entering the interferometer. This will be the case when the input laser light is reflected back onto itself. The interferometer has a photodiode detector at its back, which is connected to an amplifier. The output of the amplifier should be connected to channel 1 on the scope. For a given mirror spacing, you will observe a fixed intensity on the detector which depends on whether or not you are getting constructive or destructive interference. To generate the frequency spectrum of the laser light, the ramp generator must be turned on to generate a ramping voltage that repeats at a fixed frequency. The blanking output of the ramp generator outputs a square pulse for each ramp repeat. Connect this to channel 2 or the trigger to trigger your oscilloscope sweep. You should observe several peaks on the screen and these should repeat. Refer to the SA Plus user manual for further instructions on how to Figure 3. Example of output of interferometer when properly aligned. Note that the laser is operating in several modes under these conditions. Also, the signal is repeating every 0.18 s. resolve these narrow laser peaks. When the setup is working, you should be able to identify different laser mode structures. When the mirrors are adjusted so the laser is at its highest power, you will likely see many laser modes. Slowly adjust the mirrors away from optimum and watch the oscilloscope. You may be able to find a condition under which you can get a single laser peak, so the laser is operating in a single mode, both longitudinal and transverse. If this is difficult, at least try to obtain a minimum number of lines for analysis. 5. Digital data acquisition using the GPIB interface After you get the interferometer aligned and can observe a clean signal similar to that shown above, you should stop and figure out how to transfer data from the oscilloscope to the computer. Fortunately, our oscilloscopes are digital and we can directly transfer the digital data to the computer. You will now apply the skills that you learned in Experiment 1 to write a short data acquisition program using Labwindows. The data is transferred using a standard interface called the GPIB, or General Purpose Interface Bus. This is an old standard for talking to instruments with a computer and its protocol is well developed. Labwindows has a large collection of commands designed to send and

Northeastern University, PHYS5318 Spring 2014, 5 receive commands over the GPIB. With many instruments, you would first look in the manual and learn the commands that must be sent to the instrument to tell it to send data or change settings. This can take a lot of work, but in some cases it is necessary. Fortunately, the Tektronix TDS210 oscilloscope is a very common instrument and the GPIB commands have already been written into special programs for this oscilloscope, referred to as drivers. We have already downloaded the Tektronix TDS2xx drivers from the National Instruments web site and installed them in Labwindows. Write a simple program to read the waveform from the oscilloscope, display it on the front panel of your program, and write it to a file. There should be an example program available on the computer for this experiment, which you can use to start with, but please only edit a copy of the example program, do not attempt to overwrite the program. 6. Analyzing the data and writing the report The objective of this experiment is to observe different types of laser modes and quantify your observations. Set the laser mirrors so you are observing multiple transverse modes and measure the laser power using the power meter. Now look at the frequencies observed on the oscilloscope. Save this image and discuss it. If possible, find conditions under which you observe only one peak (single mode) repeated, or as few modes as possible. Measure the laser power and the spectrum. What do you see on the oscilloscope? Set the time scale so you can measure the width of the peak. Find the width of this peak. Is it a reasonable value? What is this width in Hz? What is the linewidth in nm? Use the fact that the center wavelength of the laser is 632.8 nm. Make a graph of this data with the x axis in units of Hz. Adjust the laser to lase in multiple modes. Extract your data and plot it in Excel. Measure the line spacing and explain it in terms of Eqs. 1-3 describing the cavity mode spacing. Do this for one cavity length. Are your results consistent with these equations? Hint: You will need to use the fact that this interferometer has an FSR of 2 GHz to calculate the linewidth.