Similar documents
Temperature Control of Air Heater with DeltaV

Level control with DeltaV

Level Control with DeltaV

PT-100 Temperature Measurement

Two-Tank Alarm Management

Using Outlook Web Access

Quick Start Guide. Hosting Your Domain

Hardware-in-the-Loop Simulation

Instructions for Importing (migrating) Data

C-more Remote Access, Data Log, FTP File Transfer, and Tutorial

Upgrading from MSDE to SQL Server 2005 Express Edition with Advanced Services SP2

To successfully initialize Microsoft Outlook (Outlook) the first time, settings need to be verified.

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

NAS 225 Introduction to FTP Explorer

Installing Remote Desktop Connection

Mariemont City Schools

Application Note. Example of user log on Magelis HMI with XB5S5B2L2 biometric switch. Advanced Technical Support - Brazil. Version: 1.

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

Genesee Intermediate School District Technology & Media Services 2413 West Maple Avenue Flint, Michigan GenNET Self-Service Helpdesk Tipsheet

28 What s New in IGSS V9. Speaker Notes INSIGHT AND OVERVIEW

SA-9600 Surface Area Software Manual

1. Installing The Monitoring Software

Snapshot Reports for 800xA User Guide

How To Run Eve 5 On A Pc Or Mac Or Ipad (For Pc Or Ipa) On A Network (For Mac) On Your Computer Or Ipro (For Ipro) On An Ipro Or Ipo (For Windows)

Using Remote Web Workplace Version 1.01

NOVA MULTI-MONITORING SOFTWARE. Instruction Manual

ICP Data Entry Module Training document. HHC Data Entry Module Training Document

Resource Guide INSTALL AND CONNECT TO CISCO ANYCONNECT VPN CLIENT (FOR WINDOWS COMPUTERS)

FrontDesk Installation And Configuration

D800002X122 March Getting Started With Your DeltaV Digital Automation System

Step by Step. Use the Cloud Login Website

GRS Advantage Website User Reference Guide

Using. Microsoft Virtual PC. Page 1

How To Sync Google Drive On A Mac Computer With A Gmail Account On A Gcd (For A Student) On A Pc Or Mac Or Mac (For An Older Person) On An Ipad Or Ipad (For Older People) On

Accessing The Doctors Clinic Physician Connect

NASP PRO USER GUIDE. Contents

MiraCosta College now offers two ways to access your student virtual desktop.

TECHNICAL NOTE. The following information is provided as a service to our users, customers, and distributors.

Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges

User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720

Internet Setup Manual for Windows 95/98

Setting up in Outlook Express

IGSS. Interactive Graphical SCADA System. Quick Start Guide

WinCC. Configuration Manual. Manual Volume 3

Building a groov HMI for Allen-Bradley Logix Systems. About groov. Building a groov HMI for Allen-Bradley Logix. A-B Systems and groov

Jump Start: Aspen HYSYS Dynamics V7.3

SOS SO S O n O lin n e lin e Bac Ba kup cku ck p u USER MANUAL

Global Image Management System For epad-vision. User Manual Version 1.10

FORM SIMPLICITY QUICK REFERENCE GUIDE PROFESSIONAL/ULTIMATE EDITION

TAMUS Terminal Server Setup BPP SQL/Alva

Frequently Asked Questions

INF-USB2 and SI-USB Quick Start Guide

SCADA, OPC and Database Systems

icom Software Update Guide Updating the icom using the Service Tool (ist)

EBOX Digital Content Management System (CMS) User Guide For Site Owners & Administrators

User Guide. emoney for Outlook

Installing Microsoft Outlook on a Macintosh. This document explains how to download, install and configure Microsoft Outlook on a Macintosh.

MAS 90 Demo Guide: Accounts Payable

QUANTIFY INSTALLATION GUIDE

How to Use JCWHosting Reseller Cloud Storage Solution

Working with SQL Server Integration Services

LEARNING RESOURCE CENTRE GUIDE TO OFFICE 365

SUMMARY. e-soft s.r.l.

Installation Guide for Microsoft SQL Server 2008 R2 Express. October 2011 (GUIDE 1)

How To Use Exhange On Outlook On A Pc Or Macintosh Outlook 2007 On Your Pc Or Ipad (For Windows Xp) On Your Ipad Or Ipa (For Your Windows Xp). (For A Macintosh) On A

Recruitment Management System USER GUIDE

Snow Active Directory Discovery

WAM Remote Wireless Asset Monitoring. Website User Guide

WatchDox Administrator's Guide. Application Version 3.7.5

GETTING STARTED WITH STUDIO ONE ARTIST

Reading Wonders Training Resource Guide

Transitioning from TurningPoint 5 to TurningPoint Cloud - LMS 1

Install SQL Server 2014 Express Edition

InTouch Example Description

Using SSH Secure Shell Client for FTP

Quick start guide to using Attendant

SQLBackupAndFTP User Instructions (Rev 0.3) 9/14/10

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

ANYWHERE POLLING - POLLING WITH A QUESTION LIST

Apple OS / ios Installation Guide Includes MAC OSx and ios based devices

Does the GC have an online document management solution?

Preparing Your Course Shell on Blackboard Learn 9.1

File Management and File Storage

Lab: Data Backup and Recovery in Windows XP

HADS 2.1.0e Installation and migration

From a Finder window choose Applications (shown circled in red) and then double click the Tether icon (shown circled in green).

RHINO TRACKS STANDARD GPS VEHICLE TRACKER

Setting Up Monthly Reporter

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

Workshop 7 PC Software - Tracker

Backing up with Windows 7

Frog VLE Update. Latest Features and Enhancements. September 2014

How to setup Backup Anywhere on your local PC

ONcbx Feature Guide UC Desktop Client

Concession FTP User Guide May 2011 Version 1.2

Getting the best from your OneDrive

A Guide to Getting Started with the AmeriCorps VISTA Applicant Tracking Tool

User s Manual. Management Software for ATS

Web Portal Step by Step

Transcription:

Fakultet for teknologiske fag Bachelor i ingeniørfag Temperature Control with DeltaV Fakultet for teknologiske fag Adresse: Kjølnes ring 56, 3918 Porsgrunn, telefon 35 02 62 00, www.hit.no Bachelorutdanning - Masterutdanning Ph.D. utdanning

Table of contents TABLE OF CONTENTS Table of contents... 3 1 Introduction... 4 2 Program... 5 2.1 Step 1:Creating a new database... 5 2.2 Step 2: Starting to program a PID module... 5 2.3 Step 3: Connecting I/O to the PID_LOOP... 6 2.4 Step 4: Activate I/O... 8 2.5 Step 5: Assign module, alarm and events... 9 2.6 Step 6: Download... 11 3 HMI... 13 3.1 Step 1: Open a new picture... 13 3.2 Step 2: Creating interface... 14 3.3 Step 3: Creating variables... 17 4 Operate... 19 3

1 Introduction 1 INTRODUCTION In this task you will learn how to create a program and a HMI to control the temperature of the Air Heater system using a PID-controller in DeltaV. Figure 1-1 shows the Air Heater and describes the different components. Figure 1-1 Air Heater system Equation (1-1) is the mathematical model to the Air Heater system. [ ( ) ] (1-1) Where: is the air temperature at the tube outlet u[v] is the control signal to the heater [s] is the time-constant [deg C/V] is the heater gain [s] is the time-delay representing air transportation and sluggishness in the heater is the environmental(room) temperature 4

2 Program 2 PROGRAM In this chapter we will learn how to create the program used to control the temperature in the air heater model. 2.1 Step 1:Creating a new database Before we start to program in DeltaV we would like to start on an empty program where no in or outs are used. This is easily done with the use of database. To avoid adding all the hardware configurations each time, we have premade a database that is empty, but contains the hardware configurations we need. The First thing you need to do is log on to the DeltaV station with username: Administrator and password: deltav. When this is done choose DeltaV Desktop. Click on the start-menu and Database Administration. Double click on the icon Copy Database, choose Student1 and write your name in the Copy to field. Figure 2-1 is showing you how it should look like. Figure 2-1 How to set up your database Now set the database you just made active, with the Set Active Database button, this button is found in the Database Administration window. Select the database you just made and press ok. Your database is now created and active. 2.2 Step 2: Starting to program a PID module Go back to the start menu and run DeltaV Explorer. Right click on Control Strategies and select New Area. Name your new AreaAir heater. We now have a new area called Air heater. Now we just need to configure a control module. Grab a PID module from library, see Figure 2-2. 5

2 Program Choose Library Module Templates Analog Control, Select the PID_LOOP and drag and drop it down to your Area called Air heater. Figure 2-2 PID_LOOP You will find the PID loop you just added in your Air heater area. 2.3 Step 3: Connecting I/O to the PID_LOOP Right click the PID_LOOP and choose open with Control Studio see Figure 2-3. 6

2 Program Figure 2-3 Open with Control Studio We can now see that we have a PID block. The air heater model only needs one Analog in and one analog out. We need to connect these to the block. Right click the PID block and choose Assign I/O-To Signal Tag see Figure 2-4. 7

2 Program Figure 2-4 Assign I/O to Signal Tag First choose IO_IN and press modify. Browse Device Tag, Double click on CTLR and choose TLR-1-HITC01CH01. This is the first AI on the module (CH01) Press ok until you are back to where you can choose IO_OUT. Browse Device Tag, double click on CTLR and choose TLR-1-HITC02CH01. This is the first OUT on the analog out module (CH01). Press OK and then close. We have now connected the I/O to the PID controller. 2.4 Step 4: Activate I/O Now we need to activate the I/O. This is done in Exploring DeltaV. Choose applications I/O configuration see Figure 2-5. 8

2 Program Figure 2-5 Exploring DeltaV Here we can see all the modules that are connected to the station see Figure 2-6. Choose C01 and right click the CH01 and enable it. Do the same with C02 CH01. CH01 under C01 and C02 should now be activated. Figure 2-6 Configuration I/O 2.5 Step 5: Assign module, alarm and events 9

2 Program Now we need to return to Control Studio and download our program. This is done by pressing the big arrow called Download, see Figure 2-7. You will then get a question box that asks if you want to assign the module. Press yes, Choose CTLR-1-HIT, press Ok, and yes on the Control Studio box. After that, press ok and yes on everything until you have downloaded. If you get any error messages just press Ok and proceed. Figure 2-7 Download The control module and I/O is now connected to the hardware module. For alarms and events to work we need to connect this to the history module that s premade in DeltaV Then we return to Exploring DeltaV, choose your area Air heater, under Control Strategies and drag and drop it down to Alarms And Events see Figure 2-8. 10

2 Program Figure 2-8 Alarms and Events 2.6 Step 6: Download The last thing that needs to be done before we start making the user interface is to make sure everything is downloaded. Right click on Physical network and choose Download physical network. Right click again and download setup data. Right click on Control Network, choose download control network. Right click again and download Setup Data, see Figure 2-9. Figure 2-9 Download Setup Data Before we make our interface we need to download the program in Control Studio once more. Every time you make a change to the program we need to download it again, see Figure 2-10. 11

2 Program Figure 2-10 Download again The program should now be ready. We just need to make the HMI 12

3 HMI 3 HMI To be able to read and write values and simulate a process we need to create an HMI. 3.1 Step 1: Open a new picture When you are in Exploring Deltav. Choose Applications and press: DeltaV operate Configure see Figure 3-1. Figure 3-1 Exploring DeltaV Press the +sign on the folder Pictures, then templates and double click on main. You will then get a standard picture. See Figure 3-2. 13

3 HMI Figure 3-2 Main Picture Delete all the text on the picture so you get a blank picture like the one below see Figure 3-3. Figure 3-3 Blank Picture 3.2 Step 2: Creating interface Now we can begin creating our interface. In the left column you can find many premade components. We need a pipe, a fan, a temperature measure and a heating element. Choose Dynamo sets and Blowers. Drag and drop a suitable fan onto the drawing board, see Figure 3-4. 14

3 HMI Figure 3-4 Fan Then we choose Pipes_DF. Drag and drop Pipes and adjust them so you get something that looks similar to the Air heater model see Figure 3-5. 15

3 HMI Figure 3-5 Pipes Also drag a sensor to show where the temperature measurement is located. This you will find under Sensor. Also find a heating element from GeneralMfg see Figure 3-6. Figure 3-6 Temperature Measurement Find a symbol that can replicate a heating element see Figure 3-7. 16

3 HMI Figure 3-7 Heating element 3.3 Step 3: Creating variables Now we need some variables. Let s make one for PV, SP and OUT (so we can run the system manually) Here we use DeltaV_Toolbox. Press the big A and write the different variables we need. These need to be connected to our regulator. Let s start with PV. See Figure 3-8. Press ABC100 that you can find in DeltaV_toolbox. Then press the button. Browse DeltaV control parameters, air heater, pid_loop_1, pid1 and double click PV, then CV. Press ok until the Datalink box is left. Here we will swap Type to Numeric and press ok. Place the variable next to PV see Figure 3-9. Figure 3-8 Datalink 17

3 HMI Do exactly the same for SP, but choose SP, and in datalink box we need to choose in-place on the data entry to be allowed to change the variables. Place it next to SP. Figure 3-9 PV variable The only one left is OUT. Exactly the same procedure as when we did with SP, except that we choose OUT. Place the variable next to Out. You have now made the program and interface that can be used to regulate the temperature in the tube see Figure 3-10. Press ctrl+w to set the program in run mode. When you get question about saving your picture, save this with yourname.grf. Figure 3-10 Model Completed 18

4 Operate 4 OPERATE To operate the model we need to physical connect it to DeltaV. Figure 4-1 shows a sketch of how the model is to be wired Outl et Temperatur e sensor 1 Inlet Outlet AI Heating 0-5V (A) Mains cable 230V AO Temperature 1 1-5V (C) On/Off Fan adjustme nt Figure 4-1 Connection of the model When the model is connected you can press Ctrl+w to enable run mode, the model is now ready to be controlled. To get the faceplate up you need to mark either SP or OUT. You then press the faceplate button in upper left corner. If you press the button with the magnifying glass on, the detail point will appear. This is where you change the PID parameters. Under tuning, Gain is the P-value, Reset is the I-value and Rate is the D-value. We choose P=2 and I=10 as start values. But feel free to experiment and find better values. See Figure 4-2 19

4 Operate On the faceplate you have options to control the process manually or set it to auto. You can trend the regulator by pressing the button that looks like a graph. You will then see SP, OP and PV. Figure 4-2 Operate Run 20