AC SIMDIS Solutions. True Boiling Point Distribution up to C120. Compliance with Global Standard Test Methods



Similar documents
AC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer

The Distillation Group, Inc.

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

CHROMOCTANE O N LINE ANALYZER

Process Instrumentation

ROC800L Liquid Application Software

A Complete Solution for Method Linearity in HPLC and UHPLC

Crude Assay Report. Crude Oil sample marked. "AL SHAHEEN CRUDE OIL" dated 10th April On Behalf Of. Maersk Oil Qatar AS

High-temperature Simulated Distillation Applications in Petroleum Characterization. Dan C. Villalanti, Joseph C. Raia, and Jim B.

Optimal Model-Based Production Planning for Refinery Operation

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Transformer Oil Gas Analysis

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

INVESTIGATION ON DIESEL COLD FLOW PROPERTIES

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

ADU 5. Automatic Distillation Unit

23 The Thermal Conductivity Detector

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Pesticide Analysis by Mass Spectrometry

Gas Detection for Refining. HA University

Gas Turbine Fuel Control Valve

Did you know that. NEXBTL renewable diesel. Premium quality renewable diesel. As a drop-in biofuel, NEXBTL diesel behaves exactly like fossil diesel.

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

ASimple Guide to Oil Refining

Determination of Ultra Low Chlorine (and Sulfur) in Oil

OIL MARKETS AND THEIR ANALYSIS IEA ENERGY TRAINING WEEK PARIS, APRIL 2013

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Plutonio Crude oil from Angola

<Insert Picture Here> JD Edwards EnterpriseOne Bulk Stock Industry & Overview

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Providing a complete Ethernet anywhere solution. IS Ethernet Solutions

Thermo Scientific ConFlo IV Universal Interface

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

DMA-1 Direct Mercury Analyzer

SULFUR RECOVERY UNIT. Thermal Oxidizer

Analytical Standards and CRMs for the Petroleum Industry

Gas Chromatography Liner Selection Guide

Application of Synthetic Diesel Fuels

Reliability Accuracy Performance

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

FACE GASOLINES AND BLENDS WITH ETHANOL: DETAILED CHARACTERIZATION OF PHYSICAL AND CHEMICAL PROPERTIES

Application of Simulation Models in Operations A Success Story

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Effect of GTL Diesel Fuels on Emissions and Engine Performance

Dräger X-dock Release Notes Software-Update and Manager Software 1.7.0

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Get the Right GC for Your Industry

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:

Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x

Refinery Equipment of Texas. Mini - Refinery Feasibility Overview

Dual Fuel Medium Speed Product. Presenter Name Date

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

MILESTONE H E L P I N G C H E M I S T S

TO THE MINISTERIAL COUNCIL OF THE ENERGY COMMUNITY represented by the Presidency and the Vice-Presidency of the Energy Community REASONED REQUEST

Syngas Purification Units

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

Drayton Digistat +2RF/+3RF

BQ-9000 Quality Management System. Marketer Requirements

On-line Dissolved Gas Analysis

MINIMAT-EC-Servo Screwdriver Spindles

Analytical Test Method Validation Report Template

Refinery Evaluation Model

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers

Sulphur in Nigerian Diesel

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

MATHESON STACK EMISSION CALIBRATION PROGRAM. Experience the MATHESON Commitment to Supply Chain Excellence

Maximize Conversion and Flexibility

Dräger Alcotest 9510 Evidential Alcohol Measuring Device

AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

CIMAC Guideline

Fundamentals of Gas Chromatography

Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

VERTELIS SUITE A software suite to manage your energy performance

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

Weekly Petroleum Status Report

FP628. Nitrogen / Protein Determination by Combustion. Rev 1-6/8/11

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# RFQ)

Hydrocracking Process Description and CRITERION / ZEOLYST Hydrocracking Catalyst Applications

Refining of Crude Oil - Process

Addressing the World Helium Shortage For Gas Chromatography

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

High-Throughput 3-D Chromatography Through Ion Exchange SPE

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

SCION SQ Series GC-MS

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Worldwide Winter Diesel Fuel Quality Survey 2014

Transcription:

AC SIMDIS Solutions True Boiling Point Distribution up to C120 Compliance with Global Standard Test Methods Unique Solutions include AC 8634 & Crude Oil Analyzer Dedicated Correlations & Calculations ONE WORLD ONE COMPANY ONE TEAM www.paclp.com

www.simdis.com 2 Complete Range of Applications AC Analytical Controls (AC), the global SIMDIS market leader, provides solutions that accurately determine true boiling point data from naphtha up to crude oil samples. Full range of SIMDIS applications determine boiling points up to C120 Product range includes several unique solutions: - AC 8634 analyzer for accelerated D 86 data of jet fuel and diesel - Crude Oil analyzer Merges DHA Front End with High Temp SIMDIS Technique - Sulfur and Nitrogen SIMDIS solutions to determine Hydrocarbon, Sulfur and Nitrogen BP distributions in a single run - Wax D 5442 application Dedicated correlations and calculations are available for: - Correlation to Physical Distillation D 86 & D 1160 ( D 2887; IP 406; ISO 3924) - NOACK - DIN 51.581-2 - MOV - D 6417 - Conversion to volume % for crude oil - Cutpoints & fractions - Flashpoint ( D 7215) Excellent LIMS connectivity: upload the results directly to your LIMS or manually after approval Solutions comply with, CEN, DIN, IP and ISO SIMDIS methods A broad set of calibration, reference and quality control samples completes each SIMDIS application User group meetings allows users to improve analyzer performance SIMDIS software is compatible with major chromatographic data systems AC software puts the instrument in standby mode after analysis, to save gas and keep the instrument in optimal condition Several features contribute to the analysis precision: - Use of pre-programmed sample types - Automatic blank subtraction, calibration and system validation - Customer selective start and end algorithm Version 6,1,0,0 simdi s IP PM-CF-98 2 Sample name : REF Acquired on : 3/9/01 4:05:16 PM Vial : 103 Processed on : 6/11/01 7:52:35 AM Injection : 1 Data File : HT750A\103F0401.D General Variables Used Blank HT750A\101F0201.D Used BP calibrant HT750A\102F0301.D Used Reference Used Start elution (min) 5.005 Used End elution (min) 30.452 Total area 173938 New Response factor 5.7492e-006 Signal Reference Check Recovered Target Values Determined Values mass % BP C dbp C BP C dbp C 10.0 421.0 3.5 420.8 0.0 20.0 437.0 3.5 436.6 0.5 30.0 448.0 3.5 447.0 1.0 40.0 457.0 3.5 456.0 1.0 50.0 464.0 3.5 464.5-0.5 60.0 473.0 3.5 472.5 0.5 70.0 481.0 3.5 480.7 0.5 80.0 489.0 3.5 489.6-0.5 90.0 501.0 3.5 501.4-0.5 Maximum Squared Deviation = 43 Found Maximum Squared Squared Deviation Deviation = 43 4 Squared Found Squared test passed Deviation = 4 Squared test passed Retention Time (min) AC High Temp SIMDIS analysis of a reference sample

Compliance with Global Standard Test Methods Boiling point data is a major specification in characterizing petroleum streams. SIMDIS uses a gas chromatographic technique to determine the true boiling point (TBP) distribution. By automating the analysis the AC SIMDIS applications provide fast and accurate boiling point results. Our active involvement in worldwide standardization committees resulted in a compliance with all, CEN, DIN, IP and ISO methods and a listing of these methods in current jet fuel and diesel specifications. The AC SIMDIS application meets and exceeds the reproducibility of the worldwide standard test methods. www.simdis.com 3 Method Number D 3710 D 7096 D 2887* D 5307 D 7213 D 6352 D 7169 D 7398 D 7500 Maximum Carbon Number reported C 15 C 16 C 44 C 44 C 60 C 90 C 100 C 60 C 110 Sample Range Gasoline Naphtha Gasoline Naphtha Jet Fuel Diesel Crude Oil Lube Oil Base Stocks Lube Oil Base Stocks Residue Crude Oil FAMES (biodiesel, B100) Blends of Diesel and Biodiesel (B1 through B100) Distillates, Base Oils Lubricating Base Stocks Boiling Range Sample FBP < 260 C (500 F) FBP < 280 C (536 F) FBP < 538 C (1000 F) IBP > 100 C (212 F) FBP < 615 C (1138 F) IBP > 174 C (345 F) FBP < 700 C (1292 F) FBP > 720 C (1328 F) FBP < 538 C (1000 F) IBP > 100 C (212 F) FBP < 735 C (1355 F) Overview of SIMDIS methods *includes Accelerated SIMDIS/8634 TM Method Number ISO 3924 IP 406 IP 480 EN 15199-1 DIN 51.435 IP 507 EN 15199-2 pren 15199-3 IP 545 Maximum Carbon Number reported C 44 C 120 C 120 C 120 Sample Range Jet Fuel Diesel Lube Oil Base Stocks (totally eluting) Residue Crude Oil Boiling Range Sample FBP < 538 C (1000 F) IBP > 100 C (212 F) FBP < 750 C (1382 F) IBP > 100 C (212 F) FBP > 750 C (1382 F) FBP > 750 C (1382 F) Overview of SIMDIS CEN, DIN, IP, ISO methods Signal BP F Recovery Mass Retention Time (min) Accelerated SIMDIS analysis of a reference sample

www.simdis.com 4 Flexible Configuration The AC SIMDIS solutions are based on the new Agilent Technologies 7890 Series or the 6850 gas chromatograph equipped with: Single or dual channel, packed or capillary column(s) for boiling point separation AC proprietary Temperature Programmable Inlet to simplify system maintenance, improve peak identification and prevent column contamination Flame Ionization Detector A 16-shot automatic liquid sampler (150 tray optional) A set of calibration, reference, and quality controls samples dedicated to the method Data System Compatibility The AC SIMDIS application offers you a choice in selecting a chromatographic data system. The AC software allows fully automated analysis processing and operates on the following chromatographic data systems: ChemStation - Agilent Technologies EZChrom Elite - Agilent Technologies Atlas - Thermo Electron SIMDIS report menu offers several plot options for the chromatogram Extensive Report Options The AC SIMDIS applications offer several options to report the true boiling point distribution & analysis parameters and include dedicated correlations & calculations. Reports are fully configurable per sample type. Report Options Chromatogram and boiling point distribution plot List of calculation parameters Quality control report check Report of peak skew and column resolution parameters Tables and graphs of boiling point versus retention time or versus mass% Several correlation reports such as D86 and D1160, Flashpoint (D7215) Output of report to several formats, such as CSV, PDF file, for reviewing the results outside the SIMDIS software, direct import to excel, or direct upload to a LIMS system.

Accurate Crude Oil Analysis One unique AC solution is the Crude Oil Analyzer, which combines detailed hydrocarbon analysis (DHA) front end technique with high temperature simulation distillation. Merging the DHA and SIMDIS data of the crude oil analysis improves accuracy. This merging technique is an AC innovation and is standardized as IP 545, D 7169 and pren 15199-3. The dedicated system design of the Crude Oil Analyzer consists of the following: The AC High Temp SIMDIS application that incorporates all, DIN, IP and CEN methods for high temperature simulated distillation The AC DHA Front End application which uses a single capillary column conform IP PM-DL to characterize the C1-nC9 fraction in crude oil Merging principle for DHA & SIMDIS www.simdis.com 5 High Temp SIMDIS analysis of a crude oil Conversion to Volume% The AC High Temp SIMDIS Analyzer includes a special report option to convert data from mass% to volume % for crude oils that comply with: FBP > 538 ºC (1000 F) T (50wt%) < 538 ºC (1000 F) Converting Mass % to Volume %

www.simdis.com 6 Jet Fuel and Diesel Analysis D 2887, IP 406 & ISO 3924 To determine the true boiling point (TBP) distribution for jet fuel and diesel AC Analytical Controls offers the SIMDIS D 2887, IP 406 & ISO 3924 application. Jet fuel specifications D 1655 and DEF STAN 91-91 list D 2887 as an alternative to physical distillation D 86 in determining distillation properties for Jet A & A-1. The AC application reports both the TBP and correlated D 86 data. D 86 Boiling Point To assist refiners in determining D 86 boiling range data, AC developed the AC 8634 application. The AC8634 TM principle is now accepted within several standard methods, such as D 2887. Hydrocarbon AC 8634 analysis of a gasoil Sulfur and Nitrogen Boiling Point AC enhanced the SIMDIS application with a dedicated Sulfur and Nitrogen Chemiluminescence Detector to characterize the sulfur and nitrogen specifications. The AC CNS SIMDIS applications report the Hydrocarbon, Nitrogen and Sulfur boiling point distributions. Nitrogen 199 ppm N Carbazole Anilines, Indoles, Quinolines C1-CA C2-CA C3+-CA Sulfur 325 ppm S C1-BDTH C2-BDTH C3-BDTH DiBenzoThiophene BenzoThiophene C1-BDTH C2-BDTH AC Sulfur SIMDIS analysis of a NIST standard Example of a diesel sample on CNS - A single analysis run yields three chromatograms

User Group & PMP SIMDIS users may join the AC User Group. Members are invited to attend meetings scheduled periodically and to participate in PAC s Performance Monitoring Program. Regularly AC schedules a worldwide SIMDIS Performance Monitoring Program (PMP), which is an anonymous round robin test. AC reports the statistical values and advices on improving analysis precision. A great number of labs worldwide participate in this PMP. Optimize Analyzer Precision Sample type menu displays the pre-programmed sample types www.simdis.com 7 Several features contribute to the analysis precision: Use of pre-programmed sample types Automatic blank subtraction, calibration and system validation Customer selective start and end elution algorithm Automatic validation of the Analyzer through user-configurable reference values checks AC software puts the instrument in standby mode after analysis to save gas and to keep it in optimal condition. One-click access to the blank, calibration and reference analysis for quick validation Each system comes with a broad set of Quality Control samples Special error viewer shows users when the software detects anomalies in the analysis AC SIMDIS reference report AC High Temp SIMDIS 5010 reference sample

AMERICAS UNITED STATES PAC Corporate Headquarter 8824 Fallbrook Drive Houston, TX 77064 USA Phone: 800.444.TEST or +1 281 940 1803 Fax: +1 281 580 0719 EMEAI GERMANY Badstrasse 3-5, P.O. Box 1241 DE-97912 Lauda-Königshofen Germany Phone: +49 (0) 9343 6400 Fax: +49 (0) 9343 640 101 FRANCE BP 70285 - VERSON 14653 CARPIQUET Cedex France Phone: +33 (0) 231 264 300 Fax: +33 (0) 231 266 293 THE NETHERLANDS Innsbruckweg 35 3047 AG Rotterdam The Netherlands Phone: +31 (0) 10 462 4811 Fax: +31 (0) 10 462 6330 RUSSIA & CIS Shabolovka street, 34, Bldg. 2 115419, Moscow, Russia Phone: +7-495-617-10-86 Fax: +7-495-913-97-65 UAE Villa#8/1, Street#9 Al Karama District P.O.Box 10917 Abu Dhabi, United Arab Emirates Phone: +971 2 446 9671 Fax: +971 2 446 9672 ASIA SINGAPORE 61, Science Park Road #03-09/10 The Galen Singapore Science Park III Singapore 117525 Phone: + 65 6412 0890 Fax: + 65 6412 0899 CHINA Rm.1003, Sunjoy Mansion No.6 RiTan Rd. ChaoYang District, Beijing P.R. China 100020 Phone: +86-10-65072236 ext 370/371/372/373/375 Fax: +86-10-65072454 Features and Benefits Full range of SIMDIS applications determines boiling points up to C120 Product range includes several unique solutions: - AC 8634 analyzer for accelerated D 86 data of jet fuel and diesel - Crude Oil analyzer merges DHA Front End with High Temp SIMDIS Technique - Sulfur and Nitrogen SIMDIS solutions to determine sulfur and nitrogen distributions - Wax D 5442 application Solutions comply with, CEN, DIN, IP and ISO SIMDIS methods A broad set of calibration, reference and quality control samples completes each SIMDIS application User group meetings help users network and improve analyzer performance SIMDIS software is compatible with major chromatographic data systems Dedicated correlations and calculations are included for: - Correlation to Physical Distillation D 86 & D 1160 ( D 2887; IP 406; ISO 3924) - NOACK - DIN 51.581-2 - MOV - D 6417 - Conversion to volume % for crude oils - Cutpoints & fractions - Flashpoint ( D 7215) Excellent LIMS connectivity: upload the results directly to your LIMS or manually after approval Several features contribute to the analysis precision: - Use of pre-programmed sample types - Automatic blank subtraction, calibration and system validation - Customer selective start and end algorithm The AC SIMDIS is a complete, turnkey system that s completely assembled with all necessary valves, connections, and analyzer columns. It s ready to go, calibrated, tested to certified calibration blends, fine-tuned and delivered to the customer s facility in plug and play condition. A qualified and dedicated Service Engineer will visit at the customer s convenience after delivery to perform installation and training, so that the customer can begin getting the most benefit out of their SIMDIS right away. Plus, PAC s solid guarantee covers all parts and analytical performance during the first year. THAILAND 25 Floor, M. Thai Tower, All seasons place 87 Wireless Road, Lumpini Phatumwan Bangkok 10330 Thailand Phone : +66 2 627 9410 Fax : +66 2 627 9401 SOUTH KOREA World Vision Building #621 24-2 Youido-dong, Youngdeungpoku 150-877 Seoul Korea Phone: +82-2-785 3900 Fax: +82-2-785 3977 00.00.006 Copyright 2010 PAC L.P. All rights reserved