Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE



Similar documents
TorqPlus TM Electric Valve Actuators and Controls

ETZGAR CONVEYOR COMPANY Controls Section v12.05

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

SunMaxx Solar Filling Station Operating Instructions

Centro-Matic Automatic Lubrication Systems System Controls

Unit 24: Applications of Pneumatics and Hydraulics

Introduction to Process Control Actuators

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

Oil and Coolant Circulating Heating System. Model - OCSM

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

A descriptive definition of valve actuators

MANTA Piston Distributor for Oil and Fluid Grease

GLOLAB Two Wire Stepper Motor Positioner

EDS / EFS Series Control Stations

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Work Smart - Not Hard with a Blue Giant Lift Table

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Conventional Fire Detection and Extinguishant Control System Specification

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

Mureva Assembly surface mounted wiring devices

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

Note: This information obtained from internet sources and not verified- use at your own risk!!!!

Kobelco Extended Warranty Program.

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

EDS / EFS Series Control Stations

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Operating Manual. Rotary Drum Filter. Technology You Can Afford. Quality You Can Trust. Model: KC10 KC15 KC30 KC60

USER INSTRUCTIONS. Limitorque L Actuator. Installation Operation Maintenance. Experience In Motion FCD LMENIM AQ 06/15

BERMAD Fire Protection

Cooking at the Speed of light!

EKOS Cart. Instructions for Use

DESIGN CLARIFICATION (DC)

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Medical Air Systems: Scroll

SECTION VARIABLE FREQUENCY DRIVES

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Specifying a Variable Frequency Drive s

REMOVAL AND INSTALLATION

POINTS POSITION INDICATOR PPI4

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

IMPORTANT SAFETY RULES TO FOLLOW

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

understanding medium frequency induction melting furnace and its components

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Troubleshooting Guide for Jacks Down LED Lights

DTC Database (OBD-II Trouble Codes)

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Owner s Manual / 5600 Econominder

SECTION LOW VOLTAGE LIGHTING CONTROLS

Electro-Pneumatic Bus Door Control Mechanism

Maxi-Stamper. 200 to 1,000 Tons STAMPING OUT DOWNTIME

WHOLESALE DIRECT INC WEST 65TH STREET

Water Leak Detection System


Hydraulic Troubleshooting PRESENTED BY

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Cooling system components, removing and installing

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Points Position Indicator (PPI1) for Points Motors with Common Ground

Simple Electronic Transmission

COMMERCIAL ITEM DESCRIPTION TRUCK, LIFT, FORK, DIESEL-ENGINE-DRIVEN, PNEUMATIC-TIRED, 10,000 POUND CAPACITY 1. SCOPE. This commercial item

Cat Electronic Technician 2015C v1.0 Product Status Report 2/20/2016 4:34 PM

Series 71, 72, and 76 Modutrol IV Motors

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

Glossary of Common Crane Ter ms:

ABB drives for water Medium voltage drives for energy savings and life-cycle improvements

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Pneumatic control loops save water and energy with fixed-bed filters

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Compressor Service & Maintenance Manual

Single sub-base valve

MC4-50 Feeding System

TMS TANK MANAGEMENT SYSTEM

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

SINGLE LINE CRENTRALIZED LUBRICATION SYSTEM

Magnum Mobile Generator MMG55 Specifications

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

SPECIFICATIONS. S&C Switch Operators Type PM SPECIFICATION BULLETIN For Field Retrofit on Manual PMH, PMS, and PME Pad-Mounted Gear

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

Technical Information

AC Electric Motors best practice

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Transcription:

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE Almost every business day, M&H is assembling and testing valves with Electric Motor operators. Electric motor operator may be furnished on NRS and OS&Y Gate Valves, plug valves, & butterfly valves. Motor operated valves are specified where frequent operation is necessary or where valves are located in remote, inaccessible or hazardous places. For large valves and frequently used valves, operating costs are reduced and efficiently increased by the remote control possible with electric motor operation. In emergencies, quick operation of valves by electric motor may be extremely vital. Electric Motor Operated Valves are used in industrial plants, power plants, water plants, sewage disposal systems and miscellaneous pipe lines. Some of their specific uses include the following: Large Valves Intakes Outlets Pump Discharge Storage Tanks Filter Beds Booster Stations An electric motor is mounted on the valve and geared to the valve stem so that when the motor operates the valve will open or close. Adjustable limit and torque switches are arranged to stop the motor when the valve is completely opened or closed, or automatically stop the motor if there is any obstruction in the valve to prevent the gate from moving. This prevents damage both to the valve parts and to the motor and gearing. Electric equipment conforms to N.E.M.A. codes. Detailed specifications on the construction and design of motor units and controls will be furnished if desired. Motors are high torque, fully enclosed in weather-proof or explosionproof housings. When specified, motor shall include: Integral reversing starter package, which includes reversing controller, 120 volt/25 watt heater, 75 VA transformer with fused secondary & 24 point terminal strip. Available in weather-proof, explosion-proof, etc. enclosures. Three button two light push button station for open, stop and close operation with red and green lights to show whether the valve is open or closed. The green light is lit when the valve is closed, the red light is lit when the valve is open. Both red and green lights remain lit when the valve gates are in any intermediate position between open and closed. Various combinations of buttons and lights are available as well as integral, surface or flush mounting in either weather-proof or explosion-proof enclosures. Mechanical dial position indicator available when specified for easy to read position of valve gate. Available for local remote and local/remote indication. Motor operating units are available with auxiliary handwheels for manual operation, which do not turn during electric operation. If the electric current comes on during manual operation, the handwheel of the unit declutches automatically and thus prevents any possible injury to the operator. July 2005 / M&H Electric Motor Operator

Electric Motor Operator for: Butterfly Valves / Gate Valves / Plug Valves M&H VALVE INFORMATION REQUIRED WITH MOTOR OPERATED VALVE ORDER: 1. Type of valve (Butterfly Valve) (RW Gate Valve)(DD Gate Valve)(Plug Valve) 2. End connection 3. Valve size and quantity. 4. Maximum pressure against which valve will be required to operate (Maximum Differential Pressure) and flow rate in feet/sec. if available. 5. Current Characteristics (Voltage, Phase, Cycles, A.C. or D.C.). 6. Opening or Closing time in seconds or inches per minute (Standard is 12 per minute). 7. Service: Water, etc. 8. Frequency of service; regulating or intermittent duty. 9. Maximum temperature at location of valve control. 10. Type motor desired: Weather-proof, Explosion-proof, etc. 11. Type of Reversing Controller (NEMA-Class). 12. Type of Pushbutton Station (NEMA-Class) (Normally NEMA-1 or NEMA-4). (Flush or Surface Mounted) (Number of Push buttons or Lights Usually 3 buttons, 2 lights). 13. Control Voltage. 14. Any special requirements such as mechanical dial position indicator, hand off automatic switch on pushbutton stations, etc. 15. Complete specification will required with inquiry for all motor valves. July 2005 / M&H Electric Motor Operated Valves

Cylinder or Hydraulic Operated Valves M&H VALVE INFORMATION REQUIRED WITH CYLINDER OPERATED VALVE ORDER: 1. Type of valve (Butterfly Valve) (Plug Valve) 2. End connection 3. Valve size and quantity. 4. Supply pressure provided. 5. If limit switches are required. 6. 2-way or 4-way solenoid if required. 7. If speed controls are required-what type. 8. Is a positioner required. 9. Single or double acting. 10. What type of cylinder required (i.e. Ply, SS Etc). 11. Air or water pressure provided. 12. Complete specifications will be required with inquiry for all cylinder or motor valves. July 2005 / M&H Cylinder Operated Valves