DR/4000 PROCEDURE. CHLORINE, Free



Similar documents
LZV585 (B) The 1-cm path is aligned with the arrow on the adapter

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Phosphorus, Reactive (Orthophosphate)

Quaternary Ammonium Compounds DOC

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

Method 8155 NITROGEN, AMMONIA (0 to 0.50 mg/l NH 3 -N) For water, wastewater, seawater

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Color, True and Apparent

Color, True and Apparent

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Scope and application: For testing residual corrosion inhibitors (oxygen scavengers) in boiler feed water or condensate

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

USEPA Electrode Method Method 8156

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

A Volumetric Analysis (Redox Titration) of Hypochlorite in Bleach

Solids, Volatile Dissolved and Fixed Dissolved

An Introduction to Standards and Quality Control for the Laboratory Barbara Martin

Measurement by Ion Selective Electrodes

FT FIELD MEASUREMENT OF RESIDUAL CHLORINE

(1) Hydrochloric acid reacts with sodium hypochlorite to form hypochlorous acid: NaOCl(aq) + HCl(aq) HOCl(aq) + NaCl(aq) hypochlorous acid

Thermo Scientific Orion AQUAfast Powder and Tablet Reagent Chemistry User Guide

Total Aerobic Bacteria, Yeasts and Molds

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Phosphorus, colorimetry, phosphomolybdate, automated-segmented flow

Chlorine Residual Testing Fact Sheet

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

Neutralizing an Acid and a Base

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

Current Technology of Chlorine Analysis for Water and Wastewater

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

OXIDATION-REDUCTION TITRATIONS-Permanganometry

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

Reagents also compatible in Hach

A Visual Method for the Detection of Arsenic 0 to 500 µg/l By Dan Kroll R&D Chemist. Hach Co., Loveland Colorado

Specification and Certificate of Analysis

EPB 311- Strategies for Dealing with Groundwater Treatment Systems Having High Natural Ammonia

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Preparation of frequently used solutions

Phenolphthalein-NaOH Kinetics

Standardization of Potassium Permanganate solution with Standard Sodium Oxalate Solution.

SPIKE RECOVERY AND DETERMINING A METHOD DETECTION LIMIT Pamela Doolittle, University of Wisconsin Madison, pssemrad@wisc.edu 2014

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

1.4 This method is capable of measuring DO in the range of 0.20 to 20 mg/l.

HS 1003 Part 2 HS 1003 Heavy Metals Test

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

ph Alkalinity of Water

Pocket Colorimeter II

Bluelab Soil ph Meter Instruction Manual

Odor (Threshold Odor, Consistent Series)

Removal of Chlorine Residual in Tap Water by Boiling or Adding Ascorbic Acid

Dissolving of sodium hydroxide generates heat. Take care in handling the dilution container.

XI. Methods of Analysis DETERMINATION OF POTASSIUM CARBONATE CALCULATIONS REAGENTS PROCEDURE

Syllabus OC18 Use litmus or a universal indicator to test a variety of solutions, and classify these as acidic, basic or neutral

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

Estimation of Alcohol Content in Wine by Dichromate Oxidation followed by Redox Titration

Analysis of Vitamin C Using Iodine. Introduction

FAJANS DETERMINATION OF CHLORIDE

Customer application report

Chapter 16: Tests for ions and gases

1. Qualitative Analysis of Chromium, Iron, and Copper

Determination of Aspirin using Back Titration

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

Solutions and Dilutions

Basic Chemistry of Chlorination

Supporting Guidance (WAT-SG-41)

Spectrophotometer - Milton Roy Spectronic 21D or equivalent.

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy

Juice Titration. Background. Acid/Base Titration

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

NITRIC OXIDE and NITROGEN DIOXIDE 6014

Recovery of Elemental Copper from Copper (II) Nitrate

HOW TO MAKE STANDARD SOLUTIONS FOR CHEMISTRY

Standard Methods for the Examination of Water and Wastewater

Experiment 7: Titration of an Antacid

Wastewater Reuse. Typical treated wastewater is:

Experiment 17: Potentiometric Titration

OBJECTIVE: To measure Chemical Oxygen Demand. BACKGROUND AND PRINCIPLE: SELECTION OF METHODS. Page 1

ph and Acidity in Wine and Fruit Juice

Stability of sodium hypochlorite in solution after adding sodium hydroxide

PART I: PREPARATION OF SOLUTIONS AND STANDARDIZATION OF A BASE

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Chemistry Laboratory Chemistry THE POTENTIOMETRIC TITRATION OF AN ACID MIXTURE 1

Enzyme Pre-Lab. Using the Enzyme worksheet and Enzyme lab handout answer the Pre-Lab questions the pre-lab must be complete before beginning the lab.

Sodium and Potassium chlorate synthesis, the complete guide

Instructions Answer all questions in the spaces provided. Do all rough work in this book. Cross through any work you do not want to be marked.

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

Swimming Pool and Spa Water Chemical Adjustments

Reaction in a Bag. Scientific Method Demonstrations

DETERMINATION OF PHOSPHORIC ACID CONTENT IN SOFT DRINKS

ph and Acidity in Tomato Sauce

Austin Peay State University Department of Chemistry CHEM 1021 TESTING FOR ORGANIC FUNCTIONAL GROUPS

Use of Chlorine in the Food Industry

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Transcription:

DR/4000 PROCEDURE CHLORINE, Free Method 10069 DPD method* UHR (0.1 10.0 mg/l as Cl 2 ) Scope and Application: For testing higher levels of free chlorine (hypochlorous acid and hypochlorite ion) in drinking water, cooling water, and industrial process waters. * Adapted from Standard Methods for the Examination of Water and Wastewater. Tips and Techniques Analyze samples immediately. Do not preserve for later analysis. If chlorine is present, a pink color will develop after adding DPD Free Chlorine Reagent If the chlorine concentration is typically less than 2 mg/l, use method 8021, program number 1450. Powder Pillow Method 10069 HACH PROGRAM ENTER 1 4 8 5 HACH PROGRAM: 1485 Monochlor F, LR 1. Press the soft key under HACH PROGRAM. Select the stored program number for Chlorine, HR by pressing 1485. Use the numeric keys. 2. Press: ENTER. The display will show: HACH PROGRAM 1485 Chlorine, UHR The wavelength (λ), 530 nm, is automatically selected. 3. Insert the AccuVac adapter into the sample cell module by sliding it under the thumbscrew and into the alignment grooves. Fasten with the thumbscrew. 4. Fill the 10-mL/1-cm cell to the 5-mL line with sample. ZERO 5. Place the cell into the cell holder so that the locking ridge on the cell is oriented to the left. Press the top rim of the cell on the right side to lock it in place. Close the light shield. 6. Press the soft key under ZERO. The display will show: 0.0 mg/l Cl 2 7. Remove the cell from the cell holder and add the contents of one pillow of DPD Free Chlorine to the sample. Proceed immediately to step 8. Cap and shake the cell about 20 seconds to dissolve. 8. Place the cell into the cell holder so the locking ridge on the cell is oriented to the left. Press the top rim of the cell on the right side to lock it in place. CHLORINE, Free ChlorineFree_MP_UHR_4000.fm Page 1 of 6

9. Close the light shield. Within 1 minute after reagent addition, read the results in mg/l chlorine (as Cl 2 ). Sampling and Storage Analyze samples for chlorine immediately after collection. free and combined chlorine are strong oxidizing agents and react rapidly with various compounds. Many factors such as sunlight, ph, temperature, and sample composition will influence decomposition of free chlorine in water. Method Performance Avoid plastic containers, which may have a large chlorine demand. Pretreat glass containers to remove chlorine demand by soaking in a dilute bleach solution (1 ml commercial bleach to 1 L of deionized water) for at least 1 hour. Rinse thoroughly with deionized or distilled water. If sample containers are rinsed thoroughly with deionized or distilled water after use, only occasional pretreatment is necessary. Do not use the same sample cells for free and total chlorine. If trace iodide from the total chlorine reagent is carried over to the free chlorine test, monochloramine could interfere. It is best to use separate, dedicated sample cells for free and total chlorine determinations. A common error in testing for chlorine is obtaining a representative sample. If sampling from a tap, let the water flow for at least 5 minutes to ensure a representative sample. Let the container overflow with the sample several times, then cap the sample container so there is no air above the sample. If sampling with a sample cell, rinse the cell several times with the sample, then carefully fill to the 5-mL mark. Proceed with the chlorine test immediately. Precision Standard: 5.6 mg/l Cl 2 Program 95% Confidence Limits of Distribution 1485 5.5 5.7 mg/l Cl 2 Page 2 of 6 ChlorineFree_MP_UHR_4000.fm

Sensitivity Portion of Curve Abs Concentration Entire range 0.010 0.1 mg/l Cl 2 Accuracy Check Standard Additions Method (Sample Spike) 1. Leave the unspiked sample in the sample compartment. Verify that the units displayed are in mg/l. Select standard additions mode by pressing the soft keys under OPTIONS, (MORE) and then STD ADD. 2. Press ENTER to accept the default sample volume (ml), 10. 3. Locate the average chlorine concentration shown on the certificate enclosed with the LR Voluette Ampules. When prompted for the standard concentration, use the numeric keys to enter the certificate value. Press ENTER. 4. Press the soft key under ENTRY DONE. 5. Snap the neck off of a Chlorine Voluette Ampule Standard, 50 75 mg/l Cl 2. 6. Use the Tensette Pipet to add 0.1 ml, 0.2 ml, and 0.3 ml of standard, respectively, to three 10-mL samples. Mix each thoroughly. 7. Analyze each standard addition sample as described above. Accept the standard additions readings by pressing the soft key under READ each time. Each additions should reflect approximately 100% recovery. 8. After completing the sequence, the display will show the extrapolated concentration value and the best-fit line through the standard additions data points, accounting for matrix interferences. 9. See Section 1.4.1 Standard Additions for more information. Interferences The following have been tested for interference and found to interfere at the indicated levels: Table 1 Interfering Substances Substance Level Correction Acidity Alkalinity Greater than 150 mg/l CaCO 3 May not develop full color or color may fade instantly. Greater than 250 mg/l CaCO 3 May not develop full color or color may fade instantly. 1 Neutralize to ph 6 7 with 1 N Sodium Hydroxide. 2 Determine the amount to be added on separate sample aliquot, then add the same amount to the sample being tested. 3 Correct for volume additions. 1 Neutralize to ph 6 7 with 1 N Sulfuric Acid. 2 Determine the amount to be added on separate sample aliquot, then add the same amount to the sample being tested. 3 Correct for volume additions. ChlorineFree_MP_UHR_4000.fm Page 3 of 6

Table 1 Interfering Substances (Continued) Substance Level Correction Bromine, Br 2 Chlorine dioxide, ClO 2 Chloramines, organic Chromium, oxidized (Cr 6+ ) Iodine, I 2 Manganese, oxidized (Mn 4+, Mn 7+ ) Ozone Peroxides ph (extreme sample ph or highly buffered samples) May interfere May interfere 1 Adjust sample ph to 6 7. 2 Add 2 drops Potassium Iodide (30 g/l) to a 5-mL sample. 3 Mix and wait 1 minute. 4 Add 2 drops Sodium Arsenite* (5 g/l) and mix. 5 Analyze the treated sample as described in the procedure. Subtract the result from this test from the original analysis to obtain the correct chlorine concentration. 1 Adjust sample ph to 6 7. 2 Add 2 drops Potassium Iodide (30 g/l) to a 5-mL sample. 3 Mix and wait 1 minute. 4 Add 2 drops Sodium Arsenite* (5 g/l) and mix. 5 Analyze the treated sample as described in the procedure. 6 Subtract the result from this test from the original analysis to obtain the correct chlorine concentration. Adjust to ph 6 7 using acid (1.000 N Sulfuric Acid) or base (1.00 N Sodium Hydroxide). * Samples treated with sodium arsenite for manganese or chromium interference will be hazardous wastes as regulated by the Federal RCRA for arsenic (D004). Summary of Method The range of analysis using the DPD method for free chlorine can be extended by adding more indicator in proportion to sample volume. Thus, a larger fill powder pillow of DPD Free Chlorine Reagent is added to a 5-mL sample portion. Chlorine in the sample as hypochlorous acid or hypochlorite ion (free chlorine or free available chlorine) immediately reacts with DPD (N, N-diethyl-pphenylenediamine) indicator to form a magenta color which is proportional to the chlorine concentration. Safety Good safety habits and laboratory techniques should be used throughout the procedure. Consult the Material Safety Data Sheet (MSDS) for information specific to the reagent used. Page 4 of 6 ChlorineFree_MP_UHR_4000.fm

REQUIRED REAGENTS Quantity Required Description Per Test Unit Cat. No. DPD Free Chlorine Reagent Powder Pillows...1... 100/pkg...14070-99 REQUIRED APPARATUS Sample Cell, 10-mL/1-cm, with cap...1... 2/pkg...48643-02 OPTIONAL REAGENTS Sodium Hydroxide, 1 N...100 ml MDB...1045-32 Sulfuric Acid, 1 N...100 ml MDB...1270-32 Potassium Iodide, 30 g/l...100 ml MDB...343-32 Sodium Arsenite, 5 g/l...100 ml...1047-32 OPTIONAL APPARATUS Cylinder, graduated mixing... each...1896-40 TenSette Pipet, 0.1 1.0 ml... each...19700-01 Replacement Tips for 19700-01... 50/pkg...21856-96 REQUIRED STANDARDS Chlorine Standard Solution, PourRite Ampules, 50 75 mg/l... 20/pkg...14268-20 ChlorineFree_MP_UHR_4000.fm Page 5 of 6

FOR TECHNICAL ASSISTANCE, PRICE INFORMATION AND ORDERING: In the U.S.A. Call toll-free 800-227-4224 Outside the U.S.A. Contact the HACH office or distributor serving you. On the Worldwide Web www.hach.com; E-mail techhelp@hach.com HACH COMPANY WORLD HEADQUARTERS Telephone: (970) 669-3050 FAX: (970) 669-2932 Hach Company, 1997-2003. All rights reserved. Printed in the U.S.A. 6/03 11ed Page 6 of 6 ChlorineFree_MP_UHR_4000.fm