Pocket Colorimeter II
|
|
|
- Stanley Walton
- 9 years ago
- Views:
Transcription
1 DOC Pocket Colorimeter II User Manual 04/2014, Edition 1
2
3 Table of Contents Section 1 Specifications...3 Section 2 General information Safety information Use of hazard information Precautionary labels Certification Product overview... 7 Section 3 Startup Install the batteries Install the cap cord...10 Section 4 User interface and navigation Keypad description Display description...11 Section 5 Operation Configure the instrument Run a test Show the recorded measurements Standard calibration adjust Adjust the factory calibration with a standard Set the standard calibration adjust to off User-entered calibration Channel restrictions Enter a calibration curve with standards Enter a calibration curve with the keypad Remove a calibration point Set to the factory default calibration...22 Section 6 Maintenance Clean the instrument Clean the sample cells Replace the batteries...24 Section 7 Troubleshooting...25 Section 8 Replacement parts
4 Table of Contents 2
5 Section 1 Specifications Specifications are subject to change without notice. Specification Details Dimensions (W x D x H) 6.1 x 3.2 x 15.2 cm (2.4 x 1.25 x 6 in.) Enclosure Light source Detector Display Weight Pollution degree 2 Installation category Protection class 3 Power requirements Operating environment Storage temperature Photometric precision Wavelength Filter bandwidth Absorbance range Sample cell path length Data storage Certifications Warranty IP67, waterproof at 1 m (3.3 ft) for 30 minutes (battery compartment not included). Keep out of direct sunlight. Light emitting diode (LED) Silicon photodiode LCD with backlight 0.2 kg (0.43 lb) I 4 AAA batteries; approximate life of 2000 tests (use of backlight decreases this number) Rechargeable batteries are not recommended. 0 to 50 C (32 to 122 F), 0 to 90% relative humidity non-condensing 20 to 55 C ( 7.6 to 131 F) ± Abs Fixed wavelength ±2 nm, different for each model 15 nm 0 to 2.5 Abs 1 cm (5 10 ml), 25 mm (10 ml) Last 10 measurements CE mark 2 years 3
6 Specifications 4
7 Section 2 General information In no event will the manufacturer be liable for direct, indirect, special, incidental or consequential damages resulting from any defect or omission in this manual. The manufacturer reserves the right to make changes in this manual and the products it describes at any time, without notice or obligation. Revised editions are found on the manufacturer s website. 2.1 Safety information N O T I C E The manufacturer is not responsible for any damages due to misapplication or misuse of this product including, without limitation, direct, incidental and consequential damages, and disclaims such damages to the full extent permitted under applicable law. The user is solely responsible to identify critical application risks and install appropriate mechanisms to protect processes during a possible equipment malfunction. Please read this entire manual before unpacking, setting up or operating this equipment. Pay attention to all danger and caution statements. Failure to do so could result in serious injury to the operator or damage to the equipment. Make sure that the protection provided by this equipment is not impaired. Do not use or install this equipment in any manner other than that specified in this manual Use of hazard information D A N G E R Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or serious injury. W A R N I N G Indicates a potentially or imminently hazardous situation which, if not avoided, could result in death or serious injury. C A U T I O N Indicates a potentially hazardous situation that may result in minor or moderate injury. 5
8 General information N O T I C E Indicates a situation which, if not avoided, may cause damage to the instrument. Information that requires special emphasis Precautionary labels Read all labels and tags attached to the instrument. Personal injury or damage to the instrument could occur if not observed. A symbol on the instrument is referenced in the manual with a precautionary statement. This symbol, if noted on the instrument, references the instruction manual for operation and/or safety information. Electrical equipment marked with this symbol may not be disposed of in European domestic or public disposal systems. Return old or end-of-life equipment to the manufacturer for disposal at no charge to the user Certification Canadian Radio Interference-Causing Equipment Regulation, IECS-003, Class A: Supporting test records reside with the manufacturer. This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de classe A répond à toutes les exigences de la réglementation canadienne sur les équipements provoquant des interférences. FCC Part 15, Class "A" Limits Supporting test records reside with the manufacturer. The device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: 1. The equipment may not cause harmful interference. 2. The equipment must accept any interference received, including interference that may cause undesired operation. 6
9 Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their expense. The following techniques can be used to reduce interference problems: 1. Move the equipment away from the device receiving the interference. 2. Reposition the receiving antenna for the device receiving the interference. 3. Try combinations of the above. 2.2 Product overview General information This instrument is a portable filter photometer used for testing water. Refer to Figure 1. This instrument is configured at the factory to measure one or two specific parameters. This instrument is calibrated at the factory. No user calibration is necessary. Note: This instrument has not been evaluated to measure chlorine and chloramines in medical applications in the United States. 7
10 General information Figure 1 Instrument overview 1 Instrument cap 3 Cell holder with 1-cm cell adapter 1 2 Cell holder 4 Display 5 Keypad 1 Factory installed in some models 8
11 Section 3 Startup 3.1 Install the batteries W A R N I N G Explosion hazard. Incorrect battery installation can cause the release of explosive gases. Be sure that the batteries are of the same approved chemical type and are inserted in the correct orientation. Do not mix new and used batteries. Install the batteries as shown in Figure 2. Figure 2 Install the batteries 9
12 Startup 3.2 Install the cap cord Attach the cap cord to prevent loss of the instrument cap. Refer to Figure 3. Figure 3 Install the cap cord 10
13 Section 4 User interface and navigation 4.1 Keypad description Figure 4 shows the keypad and gives the key functions. Figure 4 Keypad 1 Power/Backlight key: Sets the power to on and off. Push and hold for 1 second to set the backlight to on or off. 2 Zero/Scroll key: Sets the instrument to zero, scrolls through menu options and numbers 3 Menu key: Enters and goes out of menu mode. 4 Read/Enter key: Starts a sample measurement, selects a menu option, moves the cursor to the next digit 4.2 Display description Figure 5 shows the values and icons shown on the display. 11
14 User interface and navigation Figure 5 Display 1 Numeric display: Measured value or menu options 2 Range icon: Selected range or parameter 3 Range value: Range(s) or parameters 4 Menu icon: The instrument is in menu mode. 5 Calibration adjusted icon: The factory default calibration was adjusted or a user-entered calibration curve was entered. Refer to the expanded user manual on the manufacturer's website. 6 Low battery icon: Battery level is 10%. Flashes when the battery level is too low to complete measurements. 12
15 Section 5 Operation 5.1 Configure the instrument 1. Push. 2. Push to scroll through the menu options. Push to select an option. Option Description SEL Sets the measurement range or parameter. Push to toggle between the measurement ranges or parameters. 00:00 Sets the time in 24-hour format (hh:mm). Push to change the time. Push to change the first digit, then to go to the next digit. rcl Shows the last 10 measurements recorded. Push to show the recorded measurements (01 most recent measurement, 10 oldest measurement). Push to scroll through the measurements. To select a measurement by number, push to select the number and then. Push to go out of this option. SCA Refer to Standard calibration adjust on page Push to go back to measurement mode. 5.2 Run a test W A R N I N G Chemical exposure hazard. Obey laboratory safety procedures and wear all of the personal protective equipment appropriate to the chemicals that are handled. Refer to the current safety data sheets (MSDS/SDS) for safety protocols. The basic measurement steps necessary to run a test follow. Refer to the applicable method to run a specific test. 1. Select the applicable measurement range or parameter. Refer to Configure the instrument on page Prepare the blank according to the method document. Make sure to use the correct sample cell size. Rinse the sample cell and cap with the blank before the sample cell is filled. 13
16 Operation 3. Close the sample cell and clean the optical faces of the sample cell with a lint-free cloth. 4. Insert the blank sample cell into the cell holder. Make sure to install the blank sample cell in the correct and consistent orientation so that the results are more repeatable and precise. Refer to Figure Install the instrument cap over the cell holder. Refer to Figure Push to set the instrument zero. The display shows "0.000", or the degree of resolution that was previously selected. 7. Prepare the sample. Rinse the sample cell and cap with the sample three times before the sample cell is filled. Add reagents as specified by the method document. 8. Close the sample cell and clean the optical surfaces of the cell with a lint-free cloth. 9. Insert the sample into the cell holder. Make sure to install the sample cell in the correct and consistent orientation so that the results are more repeatable and precise. Refer to Figure Install the instrument cap over the cell holder. Refer to Figure Push. The display shows the results in concentration units or absorbance. Note: The result flashes if the result is less or more than the instrument range. 12. Remove the prepared sample from the cell holder. 13. Immediately empty and rinse the sample cell. Rinse the sample cell and cap three times with deionized water. 14
17 Operation Figure 6 Sample cell orientation 1 Orientation mark 2 Sample cell, 25-mm (10 ml) 3 Sample cell, 1-cm (10 ml) 15
18 Operation Figure 7 Install the instrument cap over the cell holder 5.3 Show the recorded measurements Refer to the "rcl" option in Configure the instrument on page
19 5.4 Standard calibration adjust Use the standard calibration adjust (SCA) option when a calibration must be adjusted to meet regulatory requirements. The factory calibration is adjusted slightly with the standard calibration adjust (SCA) option so that the instrument shows the expected value of the standard solution. The adjusted calibration is then used for all test results. This adjustment can increase the test accuracy when there are slight variations in the reagents or instruments. Note: For instruments with factory-calibrated ranges or methods, the standard calibration adjust (SCA) feature is disabled when a user-entered method is entered into the instrument. To set SCA back to on, set the instrument to the factory default calibration. Refer to Set to the factory default calibration on page Adjust the factory calibration with a standard 1. Complete the test procedure for the range to calibrate. For the sample, use the standard solution concentration given in the test procedure documentation. Note: If a standard solution concentration is not given in the test procedure documentation, a different known standard can be used. 2. When the test procedure is completed, push. 3. Push until SCA shows, then push. The display shows the standard calibration adjust value. 4. If a different known standard is used, enter the value of the standard: a. Push until "Edit" shows, then push. b. Push to enter the value of the standard. Push to go to the next digit. 5. Push to add the standard calibration adjust value to the factory calibration curve. The calibration adjusted icon shows on the display. Refer to Figure 5 on page 12. Operation 17
20 Operation Set the standard calibration adjust to off To use the factory default calibration again, set standard calibration adjust (SCA) to off. 1. Push. 2. Push until SCA shows, then push. 3. Push until "OFF" shows, then push. Note: To set the SCA function to on again, calibrate with a standard. 5.5 User-entered calibration This instrument accepts a user-prepared calibration curve. The calibration curve can be from 0 to 2.5 absorbance. Make sure that the calibration curve includes standard values that are less and more than the range of interest. The instrument range will be the same as the calibration range. For example, when the standards that are used are 1.00, 2.00 and The instrument range is 1.00 to There are two options to enter a user calibration curve: Enter a calibration curve with standards The standard solution values are entered with the keypad and the absorbance values are measured. Enter a calibration curve with the keypad The standard solution values and absorbance values are entered with the keypad. Note: If the instrument is set to off or the instrument power is removed before a user-entered calibration curve is completed, the calibration curve is not saved. The instrument automatically switches off in user-entered calibration entry mode after 60 minutes of no activity. User-entered calibrations are completed when the user goes out of calibration (cal) mode or edit mode Channel restrictions A user-entered calibration curve can be entered into any channel that does not contain a factory-programmed curve. These channels have the label: abs on the instruments that have a single factory calibration 18
21 Operation 1 and 2 on the single wavelength instruments that are not calibrated Any chemistry that can be done at the instrument wavelength can contain a user-entered calibration in these channels Enter a calibration curve with standards Note: Deionized water can be used for the blank unless the sample is significantly more turbid or has more color than deionized water. 1. Set the instrument to the range to calibrate. Refer to Configure the instrument on page Prepare the blank and the reacted standard solution. Refer to the test procedure. Let the color fully develop. 3. Set the instrument to zero. a. Insert the blank sample cell in the cell holder. b. Install the instrument cap over the cell holder. c. Push. The display shows , then d. Remove the instrument cap. e. Remove the sample cell from the cell holder. 4. Push and hold until "USER" and then "CAL" shows, then push. Note: If "USER" and "CAL" do not show, the factory calibration cannot be changed on the selected range. 5. If "RES" shows on the display, set the resolution. a. Push. The resolution setting (decimal placement) shows. b. To change the resolution, push, then. Push to save the change. c. To not change the resolution, push. Note: "RES" does not show on the display of factory-calibrated instruments because the resolution cannot be changed. Only instruments that are not factory calibrated or have "abs" as one of the two ranges show "RES" on the display. 19
22 Operation 6. When "S0" shows on the display, push. Push to enter the blank value, then push. Note: Push to go to the next digit. 7. When A0 shows on the display, measure the absorbance of the blank. a. Insert the blank sample cell in the cell holder. b. Install the instrument cap over the cell holder. c. Push. The display shows the absorbance value for "S0". d. Remove the sample cell from the cell holder. 8. Push to show "S1". 9. When "S1" shows on the display, push. Push to enter the first standard value, then push. Note: Push to enter the next digit. 10. When "A1" shows on the display, measure the absorbance of the reacted standard solution. a. Insert the reacted standard sample cell in the cell holder. b. Install the instrument cap over the cell holder. c. Push. The display shows the absorbance value for "S1". d. Remove the sample cell from the cell holder. 11. The calibration is completed with two calibration points. If additional standards are necessary for calibration: a. Push until Add shows, then push. b. Do steps 9 10 again to enter more standards. 12. Push two times to go back to measurement mode Enter a calibration curve with the keypad At least two data pairs are necessary to enter a user-prepared calibration curve. A concentration value and the absorbance value for the given concentration is necessary for each data pair. A maximum of 10 data pairs can be entered. Note: This procedure can also be used to change the data pairs in a userentered calibration curve or factory calibration curve. 20
23 1. Set the instrument to the range to calibrate. Refer to Configure the instrument on page Push and hold until "USER" and then "CAL" shows, then push. Note: If "USER" and "CAL" do not show, the factory calibration cannot be changed on the selected range. 3. Push until "EDIT" shows, then push. 4. If "RES" shows on the display, set the resolution. a. Push. The resolution setting (decimal placement) shows. b. To change the resolution, push, then. Push to save the change. c. To not change the resolution, push. Note: "RES" does not show on the display of factory-calibrated instruments because the resolution cannot be changed. Only instruments that are not factory calibrated or have "abs" as one of the two ranges show "RES" on the display. 5. When "S0" shows on the display, push. Push to enter the concentration value of the first data pair, then push. Note: Push to go to the next digit. 6. When "A0" shows on the display, push. Push to enter the absorbance value of the first data pair, then push. "S1" shows on the display. 7. Do steps 5 6 again to enter the second data pair (S1 and A1). 8. The calibration is completed with two data pairs. If additional data pairs are necessary for calibration: a. When Add shows, push. b. Do steps 5 6 again to enter more data pairs. 9. Push two times to go back to measurement mode. Operation Remove a calibration point To remove a calibration point from a user-entered calibration curve: 21
24 Operation 1. Set the instrument to the range to calibrate. Refer to Configure the instrument on page Push and hold until "USER" and then "CAL" shows. Note: If "USER" and "CAL" do not show, the factory calibration cannot be changed on the selected range. 3. Push until "EDIT" shows, then push. Note: Calibration points can also be removed in calibration (CAL) mode. 4. Push until the calibration point to remove shows (i.e., S0 or S1), then push. 5. Push until "del" shows, then push. Note: The minimum number of data pairs is two. When only two data pairs remain, no more data pairs can be removed. 6. Push two times to go back to measurement mode Set to the factory default calibration 1. Set the instrument to the applicable range. Refer to Configure the instrument on page Push and hold until "USER" and then "CAL" shows. Note: If "USER" and "CAL" do not show, the factory calibration cannot be changed on the selected range. 3. Push until "dfl" shows, then push. 22
25 Section 6 Maintenance C A U T I O N Multiple hazards. Only qualified personnel must conduct the tasks described in this section of the document. N O T I C E Do not disassemble the instrument for maintenance. If the internal components must be cleaned or repaired, contact the manufacturer. 6.1 Clean the instrument Clean the exterior of the instrument with a moist cloth and a mild soap solution and then wipe the instrument dry. 6.2 Clean the sample cells C A U T I O N Chemical exposure hazard. Obey laboratory safety procedures and wear all of the personal protective equipment appropriate to the chemicals that are handled. Refer to the current safety data sheets (MSDS/SDS) for safety protocols. C A U T I O N Chemical exposure hazard. Dispose of chemicals and wastes in accordance with local, regional and national regulations. Most laboratory detergents are used at recommended concentrations. Neutral detergents, such as Liquinox, are safer to use when regular cleaning is necessary. To decrease the cleaning times, increase the temperature or use an ultrasonic bath. To complete the cleaning, rinse a few times with deionized water and then let the sample cell air dry. Sample cells may also be cleaned with acid, followed by a thorough rinse with deionized water. Note: Always use acid to clean sample cells that were used for low-level metal tests. 23
26 Maintenance Special cleaning methods are necessary for individual procedures. When a brush is used to clean sample cells, take extra care to avoid scratches on the interior surfaces of the sample cells. 6.3 Replace the batteries Replace the batteries when the battery power level is low. Refer to Install the batteries on page 9. 24
27 Section 7 Troubleshooting Error Description Solution E-0 No zero In user calibration mode, a standard solution was measured before the instrument zero was set. Measure a blank solution to set the instrument to zero. E-1 Ambient light error 1 There is ambient light in the cell holder. Make sure that the instrument cap is fully installed over the cell holder. E-2 LED error 1 The LED (light source) is out of regulation. Replace the batteries. Make sure that the LED in the cell holder comes on when or is pushed. E-3 Standard adjust error The measured value of the standard solution is more than the adjustment limits. Prepare a fresh standard. The standard solution is not within the concentration range that can be used for standard calibration adjust. Prepare a standard with a value at or near the recommended concentrations given in the procedure. Make sure that the concentration of the standard solution is entered correctly. E-6 Abs error The absorbance value is not correct or the user-entered calibration curve has fewer than two points. Enter or measure the absorbance value again. E-7 Standard value error The standard solution concentration is equal to another standard solution concentration that is already entered in the user-entered calibration curve. Enter the correct standard concentration. E-9 Flash error The instrument is not able to save data. 25
28 Troubleshooting Error Description Solution Reading flashes The reading is more or less than the instrument range. 2 If the reading is less than the instrument range, make sure that the instrument cap is fully installed over the cell holder. Measure a blank. If the blank reading is not zero, set the instrument to zero again. If the reading is more than the instrument range, identify if there is a light blockage in the cell holder. Dilute the sample. Do the test again. For factory-calibrated programs, the maximum and minimum values always equal the factorycalibrated values and cannot be changed. 1 When an E-1 or E-2 error occurs on a measurement, the display shows _.. The decimal place depends on the chemistry. If the E-1 or E-2 error occurs while the instrument is set to zero, set the instrument to zero again. 2 The flashing value will be 10% over the upper test range limit. 26
29 Section 8 Replacement parts W A R N I N G Personal injury hazard. Use of non-approved parts may cause personal injury, damage to the instrument or equipment malfunction. The replacement parts in this section are approved by the manufacturer. Note: Product and Article numbers may vary for some selling regions. Contact the appropriate distributor or refer to the company website for contact information. Replacement parts Description Quantity Item no. AAA batteries, alkaline 4/pkg Cap cord Instrument cap Sample cell, 25 mm (10 ml), with caps 6/pkg Sample cell, 1 cm (10 ml), with caps 2/pkg
30 Replacement parts 28
31
32 HACH COMPANY World Headquarters P.O. Box 389, Loveland, CO U.S.A. Tel. (970) (800) (U.S.A. only) Fax (970) HACH LANGE GMBH Willstätterstraße 11 D Düsseldorf, Germany Tel. +49 (0) Fax +49 (0) [email protected] HACH LANGE Sàrl 6, route de Compois 1222 Vésenaz SWITZERLAND Tel Fax Hach Company/Hach Lange GmbH, All rights reserved. Printed in U.S.A.
Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls
Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific
Phosphorus, Reactive (Orthophosphate)
Phosphorus, Reactive (Orthophosphate) DOC316.53.01113 Amino Acid Method 1 Method 8178 0.23 to 30.00 mg/l PO 4 Reagent Solution Scope and application: For water, wastewater and seawater. 1 Adapted from
Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856
Nickel DOC316.53.01065 Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows
Esterification Method 1 Method 8196 27 to 2800 mg/l (as acetic acid) Reagent Solution
Volatile Acids DOC316.53.01144 Esterification Method 1 Method 8196 27 to 2800 mg/l (as acetic acid) Reagent Solution Scope and application: For digestor sludges. 1 Adapted from The Analyst, 87, 949 (1962).
LZV585 (B) The 1-cm path is aligned with the arrow on the adapter. 5940506
Chlorine, Total DOC316.53.01029 USEPA DPD Method 1 Method 10070 0.1 to 10.0 mg/l Cl 2 (HR) Powder Pillows Scope and application: For testing higher levels of total chlorine (free and combined) in drinking
Color, True and Apparent
Color, True and Apparent DOC316.53.01037 Platinum-Cobalt Standard Method 1, 2, 3 Method 8025 15 to 500 color units 5 to 500 color units (low range technique) Scope and application: For water, wastewater
Chlorine, Total. DPD Method 1 Method 10101 0.09 to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information
Chlorine, Total DOC316.53.01028 DPD Method 1 Method 10101 0.09 to 5.00 mg/l Cl 2 Test 'N Tube Vials Scope and application: For testing higher levels of total (free plus combined) chlorine in drinking water,
Color, True and Apparent
Color, True and Apparent DOC316.53.01037 Platinum-Cobalt Standard Method 1, 2, 3 Method 8025 15 to 500 color units Scope and application: For water, wastewater and seawater; equivalent to NCASI method
USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls
Iron, Total DOC316.53.01053 USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater; digestion is required
FerroVer Method 1 Method 10249 0.1 to 3.0, 1.0 to 30.0 and 10.0 to 300.0 mg/l Fe Powder Pillows
Iron, Total DOC316.53.01314 FerroVer Method 1 Method 10249 0.1 to 3.0, 1.0 to 30.0 and 10.0 to 300.0 mg/l Fe Powder Pillows Scope and application: For oil and gas field waters; digestion is required for
NFC Communication Tray Model: HHX-IT3-Z
INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8
Quaternary Ammonium Compounds DOC316.53.01128
Quaternary Ammonium Compounds DOC316.53.01128 Direct Binary Complex Method Method 8337 0.2 to 5.0 mg/l as CTAB (cetyl-trimethylammonium bromide) Powder Pillows Scope and application: For cooling tower
DOC026.97.80348 DOC026.97.80348. HL4 Sonde. 11/2013, Edition 1. User Manual ENGLISH ONLY
DOC026.97.80348 HL4 Sonde 11/2013, Edition 1 User Manual Table of contents Specifications on page 3 General information on page 3 Startup on page 6 Operation on page 8 Maintenance on page 13 Troubleshooting
Wireless Optical Mouse
Wireless Optical Mouse User s Manual Model PD950P FCC STATEMENT PD950P This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause
Direct Measurement Method Method 8157 0 to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor
Oxygen, Dissolved DOC316.53.01241 Direct Measurement Method Method 8157 0 to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor Scope and application: For water, wastewater and process
Scope and application: For testing residual corrosion inhibitors (oxygen scavengers) in boiler feed water or condensate
Oxygen Scavengers DOC316.53.01105 Iron Reduction Method Method 8140 3 to 450 µg/l DEHA; 5 to 600 µg/l carbohydrazide; 9 to 1000 µg/l hydroquinone; 13 to 1500 µg/l iso-ascorbic acid (ISA); 15 to 1000 µg/l
Bounce & Spin ZebraTM
K0317 Bounce & Spin ZebraTM Please keep this instruction sheet for future reference, as it contains important information. Requires three AAA (LR03) alkaline batteries (not included). Adult assembly is
Nitrogen, Ammonia. Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table
Nitrogen, Ammonia DOC316.53.01234 Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N Scope and application: For wastewater 2. Ammonia ISE 1 Adapted from the Standard Methods for the Examination
Pocket Tach 99 (PT99) Non-Contact Tachometer
CE DECLARATION OF CONFORMITY As Manufacturer: Monarch Instrument Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA declares under Monarch s sole responsibility that the product:
USEPA Electrode Method Method 8156
ph DOC316.53.01245 USEPA Electrode Method Method 8156 Scope and application: For drinking water 1, wastewater 2 and process water. 1 Based on Standard Method 4500-H+B, ASTM Method D1293-95 and USEPA Method
User s Manual. 2010 VTECH Printed in China 91-002395-025-000
User s Manual 2010 VTECH Printed in China 91-002395-025-000 INTRODUCTION When Skipper overhears King Julien insulting the penguins, a contest is proposed. Who is more popular, the penguins or the lemurs?
HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide
HP SuperSpeed USB 3.0 PCIe x1 Card User Guide Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows
XP Series Balances Operation Manual
XP Series Balances Operation Manual North and South America: 6542 Fig Street Arvada, Colorado 84 1-8-321-1135 Tel: 33-431-7255 Fax: 33-423-4831 U.K. and Ireland: Denver House, Sovereign Way Trafalgar Business
Wireless Optical Travel Mouse
Wireless Optical Travel Mouse User s Manual PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING THIS DEVICE. Table of Contents FCC Statement Page 3 Introduction.. Page 6 Package Contents.. Page
62 Max/62 Max + Infrared Thermometer
Infrared Thermometer Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measurement of the infrared energy radiated from the target
D UTILISATION. Catch-Me-Kitty. 2011 VTech Printed in China 91-002585-003 美
MANUEL User's Manual D UTILISATION Catch-Me-Kitty TM 2011 VTech Printed in China 91-002585-003 美 Dear Parent, Ever notice the look on your baby s face when they learn something new through their own discovery?
4.3-inch Back-Up Camera
TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION
T55003. TPMS Tool Manual 1. T55003 INTRODUCTION 2. KEYPAD SUMMARY AND FUNCTIONS
T55003 TPMS Tool Manual To ensure correct operation and service, read the following instructions before operating the T55003 Tool. 1. T55003 INTRODUCTION The T55003 interacts with the tire pressure sensor
Weather Radio Alarm Clock
1200093 User s Guide Weather Radio Alarm Clock Thank you for purchasing your Weather Radio Alarm Clock from RadioShack. Please read this user s guide before installing, setting up, and using your new weather
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
LASER DIAGRAM TABLE OF CONTENTS. SKY Technologies Inc. www.skytechlasers.com. Laser Diagram. Technical Specifications. Laser Operation.
TABLE OF CONTENTS LASER DIAGRAM Laser Diagram 1 Technical Specifications 2 Laser Operation 3 Laser Safety 5 Maintanence 6 Limitation of Liability 7 Warranty 8 Laser Pointer Series Operations Manual Page
Table of Contents Function Keys of Your RF Remote Control Quick Setup Guide Advanced Features Setup Troubleshooting
Congratulations on your purchase of the AT&T U-verse TV Point Anywhere RF Remote Control. This product has been designed to provide many unique and convenient features to enhance your AT&T U-verse experience.
DR/4000 PROCEDURE. CHLORINE, Free
DR/4000 PROCEDURE CHLORINE, Free Method 10069 DPD method* UHR (0.1 10.0 mg/l as Cl 2 ) Scope and Application: For testing higher levels of free chlorine (hypochlorous acid and hypochlorite ion) in drinking
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
User s Manual. for. Tote-Remote
User s Manual for Tote-Remote Remote Control & Laser Pointer for Laptop Computers TABLE OF CONTENTS Important Safety & Health Information 2 Special Notice Regarding Carrying Laser Pointers On Commercial
User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual RK-2d / RK-2t 1U Short Depth Keyboard Drawer Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October
Wireless Keyboard and Optical Mouse Bundle
Wireless Keyboard and Optical Mouse Bundle Enjoy the freedom of wireless optical precision User Manual F8E832-BNDL TABLE OF CONTENTS Introduction....................................1 Compatible Equipment............................2
CL90i. 77-021 Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser
3 - Beam Self-Leveling Cross Line Laser CL90i 77-01 Please read these instructions before operating the product Self-Leveling GB D F I E PT NL DK SE FIN NO PL GR CZ RU HU SK SI BG RO EE LV LT Contents
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4
User s manual FLIR VP50/VP52 Non-contact AC voltage detector
User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 #T559851; r. AD/ 9134/9134; en-us Table of contents 1 Disclaimers... 1 1.1 Copyright... 1 1.2 Quality assurance...
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System Instruction Manual DELUXE AND MINI RECEIVER KIT (RX) INSTRUCTIONS " WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL INDIVIDUALS
Instruction Manual Temp 4/5/6 Temperature Meter Series
Instruction Manual Temp 4/5/6 Temperature Meter Series 68X243607 Technology Made Easy... Rev. 2 01/03-1 - Preface This instruction manual serves to explain the use of the Temp 4/5/6 temperature meter.
User Guide for the Wireless Headset (HS-11W) 9235346 Issue 1
User Guide for the Wireless Headset (HS-11W) 9235346 Issue 1 DECLARATION OF CONFORMITY We, NOKIA CORPORATION declare under our sole responsibility that the product HS-11W is in conformity with the provisions
www.fisher-price.com
M9523 Please keep this instruction sheet for future reference, as it contains important information. Requires three LR44 button cell alkaline batteries (included) for bear toy operation. Adult assembly
Atomic Alarm Clock model 13131W2
Instruction Manual Atomic Alarm Clock model 13131W2 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 4 Atomic Clock... 5 Set
PEARL Portable Reading Camera
PEARL Portable Reading Camera Quick Start Guide Freedom Scientific, Inc. 440528-001 Rev. D Freedom Scientific, Inc., 11800 31 st Court North, St. Petersburg, Florida 33716-1805, USA www.freedomscientific.com
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 7-6 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified
Conference Phone UserÕs Manual. Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc.
Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc. UserÕs Manual Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of
juice pack juice pack Made for Samsung Galaxy S6 Made for Samsung Galaxy S6 edge USER MANUAL
juice pack Made for Samsung Galaxy S6 juice pack Made for Samsung Galaxy S6 edge USER MANUAL Welcome Thank you for purchasing the mophie juice pack battery case for Samsung Galaxy S6 or S6 edge. Your juice
2013 VTech Printed in China 91-009656-000 US
Rechargeable Power Pack User s Manual 2013 VTech Printed in China 91-009656-000 US INTRODUCTION The Rechargeable Power Pack makes it easier than ever to keep the InnoTab 3 or InnoTab 3S charged and ready
Intelli-Time Alarm Clock model 13027
Instruction Manual Intelli-Time Alarm Clock model 13027 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 4 Intelli-Time Clock...
Atomic Projection Alarm Clock model 13021
Instruction Manual Atomic Projection Alarm Clock model 13021 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 5 Atomic Clock...
Product Overview. Product Interface
mobile speaker Product Overview Thank you for purchasing the bēm wireless Mobile Speaker. Our speaker will bring you a new found freedom from wires while delivering an incredible sound. The Mobile Speaker
DELORME. Getting Started with. Earthmate GPS BT-20. Bluetooth
DELORME Getting Started with GPS BT-20 Bluetooth Earthmate Table of Contents Overview... 2 Hardware Features... 2 Using the Earthmate GPS BT-20... 3 Charging the Battery... 4 Troubleshooting... 4 Hardware
Automatic Wrist Blood Pressure Monitor with
Instruction Manual Automatic Wrist Blood Pressure Monitor with Model HEM-609 ENGLISH ESPAÑOL CONTENTS Before Using the Monitor Introduction...................................... 3 Important Safety Notes.............................
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System Instruction Manual DELUXE AND MINI RECEIVER KIT (RX) INSTRUCTIONS " WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL INDIVIDUALS
Optical Wireless Mouse. User s Manual
Optical Wireless Mouse Model : OM4000W User s Manual 110935-109154 Rev. 061101 User s Record: To provide quality customer service and technical support, it is suggested that you keep the following information
RT-1261A Ear and Forehead Thermometer Owner s Manual
RT-1261A Ear and Forehead Thermometer Owner s Manual 311-1261000-009 Version 1.0 April, 2009 IMPORTANT SAFETY INSTRUCTIONS nu-beca RT-1261A Ear and Forehead Thermometer READ THIS BEFORE USING The following
Wireless Stow-N-Go Keypad USER GUIDE
Wireless Stow-N-Go Keypad USER GUIDE Table of Contents Introduction...3 System Requirements...3 Installing the Battery...4 Connecting the Receiver and Installing the Default Drivers...5 Turning the Keypad
Portable Multiband Radio (120-0456A) Features Faxback Doc. # 56400
(120-0456A) Features Faxback Doc. # 56400 Your RadioShack Portable Multiband Radio is an all-in-one radio system designed to provide high-quality sound. the multi-band tuner lets you listen to the radio,
W850. Maintenance Guide
W850 Maintenance Guide August 2011 www.lexmark.com Contents...3 Cleaning the exterior of the printer...3 Storing supplies...3 Conserving supplies...3 Checking the status of supplies...4 Checking the status
Pull & Learn Car Carrier
User s Manual Pull & Learn Car Carrier 2008 VTech Printed in China 91-002289-009 049701 IM 009.indd 1 7/18/08 9:19:27 AM Dear Parent, Ever notice the look on your baby s face when they learn something
CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok
CM100 Carbon Monoxide Meter Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok CM100 Carbon Monoxide Meter English Users Manual CM100_Rev001 2008 Amprobe Test Tools.
INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE
INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE m Before Use Please read IMPORTANT SAFETY INSTRUCTIONS on page 10 before use. It is important
INSTRUCTION MANUAL. 10 series Blood Pressure Monitor with ComFit TM Cuff. Model BP785CAN FRANÇAIS ENGLISH
INSTRUCTION MANUAL 10 series Blood Pressure Monitor with ComFit TM Cuff Model BP785CAN ENGLISH FRANÇAIS TABLE OF CONTENTS Before Using the Monitor Introduction..................................................4
Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)
INSTRUCTION MANUAL ➏ ➋ ➊ Product Features ➎ ➍ ➌ Built-in wireless Bluetooth 3.0 keyboard Compatible across ios, Android, and Windows, enabling you to mix and match with devices Ultra-thin, lightweight
RADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906
RADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906 QUICK SETUP GUIDE IMPORTANT! INSTALL BATTERIES IN THE OUTDOOR TRANSMITTER BEFORE INSTALLING BATTERIES IN THE RADIO-CONTROLLED CLOCK. ALKALINE BATTERIES
MB169B+ USB Monitor. User Guide
MB169B+ USB Monitor User Guide Table of contents Notices... iii Safety information... iv Care & cleaning... v Takeback services... vi 1.1 Welcome!... 1-1 1.2 Package contents... 1-1 1.3 System requirement...
MoCA Adapter MC1001 v2 Installation Guide
Technical Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label of your product and use it to register your product at www.netgear.com/register.
When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.
BeoLab 11 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.
Targus Wireless Remote Presenter Making Your Mobile Life Easier. Visit our Web site at: www.targus.com Features and specifications are subject to change without notice. 2003 Targus Corp. 400-0110-001B
e 1 0 0 I N S T RUC TION M ANU A L
e 1 0 0 I N S T RUC TION M ANU A L The Empire Digital Level Accuracy, Readability, Durability one FEATURES: Easy to read back light Display reads right side up even if the level is upside down Audio beep
DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product
DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual Please read carefully before using this product 15 1 Table of Contents 1 Table of Contents... 16 2 Safety Instructions:... 17 3 Specification:...
56-K61A-15000. Plantronics Calisto Headset with Bluetooth USB Adapter. User Guide
56-K61A-15000 Plantronics Calisto Headset with Bluetooth USB Adapter User Guide Table of Contents Package Contents... 1 Product Features... 2 Wearing Your Headset... 3 Powering... 4 Charging... 5 Indicator
ExStik TM ph Waterproof Meters
User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL
ES-3305P V2 / ES-3308P V2. Quick Installation Guide. 09-2013 / v1.0
ES-3305P V2 / ES-3308P V2 Quick Installation Guide 09-2013 / v1.0 1 COPYRIGHT Copyright Edimax Technology Co., Ltd. all rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
Universal Laptop Charger
USER GUIDE Universal Laptop Charger NS-PWLC591/NS-PWLC591-C Before using your new product, please read these instructions to prevent any damage. NS-PWLC591/NS-PWLC591-C Insignia NS-PWLC591/ NS-PWLC591-C
QFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
Laser Wireless Rechargeable Mouse. User s Manual
Laser Wireless Rechargeable Mouse Model #: LM8000WR User s Manual Rev. 060801 User s Record: To provide quality customer service and technical support, it is suggested that you keep the following information
User Guide. Soft-Touch TM Bluetooth Laser Mouse N2953
Soft-Touch TM Bluetooth Laser Mouse 410-XXXXXXXXXXX 1 YEAR LIMITED WARRANTY: We pride ourselves on the quality of our products. For complete warranty details and a list of our worldwide offices, please
by QUICK START GUIDE 1
by QUICK START GUIDE 1 BUTTONS & CONTROLS TALK* PREVIOUS / NEXT* POWER BUTTON & LED PAIRING BUTTON LINE IN USB DC IN PLAY / PAUSE* VOLUME DOWN / UP * Only works when connected wirelessly via Bluetooth
Wireless Internet Keyboard and Laser Mouse
Wireless Internet Keyboard and Laser Mouse User s Manual Model KB1045LSR FCC STATEMENT KB1045LSR This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: (1)
User Guide. BLUETOOTH WIRELESS KEYBOARD for ipad
BLUETOOTH WIRELESS KEYBOARD for ipad 410-2119-001A / AKB32US 1 YEAR LIMITED WARRANTY: We pride ourselves on the quality of our products. For complete warranty details and a list of our worldwide offices,
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
The Determination of an Equilibrium Constant
The Determination of an Equilibrium Constant Computer 10 Chemical reactions occur to reach a state of equilibrium. The equilibrium state can be characterized by quantitatively defining its equilibrium
Plantronics Calisto Headset with Bluetooth USB Adapter User Guide 56-K61A-23010
56-K61A-23010 Plantronics Calisto Headset with Bluetooth USB Adapter User Guide Contents Package Contents... 1 Product Features... 2 Wearing Your Headset... 3 Powering Your Headset and USB Bluetooth Adapter...
Digital Library Assistant Model 701
Digital Library Assistant Model 701 Intended Use The 3M Digital Library Assistant Model 701 (DLA) is designed and tested for use in processing 3M Digital Identification Tags. These tags are used to identify
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION FRONT VIEW SENSOR TX141TH-Bv2 LED TX Sensor Battery Cover Sensor Battery Compartment 2 AA Buttons Battery Compartment 3 AAA BACK VIEW Battery
VGA to HDMI video converter with scaler
VGA to HDMI video converter with scaler VGA2HDPRO2 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com
Regulatory Compliance Statement
Regulatory Compliance Statement 0560 EU Declaration of Conformity The declaration of conformity may be consulted at www.kobo.com/userguides SAR Limits The exposure standard for wireless devices employs
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
56-A11A-10511. Plantronics Calisto Headset with Bluetooth USB Adapter. User Guide
56-A11A-10511 Plantronics Calisto Headset with Bluetooth USB Adapter User Guide Table of Contents Package Contents... 1 Product Features... 2 Wearing Your Headset... 3 Powering... 4 Charging... 5 Indicator
Zebra RW 420 Mobile Battery Eliminator Kits
Zebra Technologies Corporation 475 Half Day Road, Suite 500 Lincolnshire, IL 60069 USA Zebra RW 420 Mobile Battery Eliminator Kits Installation Instructions September, 2010 RW 420 Mobile Battery Eliminator
HANDS-FREE BLUETOOTH CONTROLLER for SMART READY TABLETS AND COMPUTERS
HANDS-FREE BLUETOOTH CONTROLLER for SMART READY TABLETS AND COMPUTERS Operating Manual 2 CONTENTS Before Turning on Your PED... 4 Power... 5 ON... 5 OFF... 5 Modes... 6 Changing the MODE... 7 Connecting
Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE
Sodium DOC316.53.01240 Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE Scope and application: For drinking water and process water. Test preparation Instrument-specific information This procedure
ZigBee Extender 3. Features. Supported Models and Requirements. Important Safety Instructions. What Is Included: Specifications
ZigBee Extender 3 Features The Card Access ZigBee Extender 3 operates as a ZigBee (IEEE 802.15.4) router and mesh extender. The Extender is designed to improve ZigBee signal latency that can occur when
Pad. Quick Start Guide
Pad Quick Start Guide Copyright 2008 Mimio Congratulations on your mimio Pad purchase! mimio Pad is a 4 GHz wireless pad. To configure mimio Pad for use, install the mimio Studio software and plug the
Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide
Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide Features: Bluetooth Wireless technology Compact design fits in the palm of your hand and weighs less than 2 oz. Comfortable Behind the Neck design
Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy
Determining the Free Chlorine Content of Swimming Pool Water Computer 33 Physicians in the nineteenth century used chlorine water as a disinfectant. Upon the discovery that certain diseases were transmitted
INSTRUCTION MANUAL MODEL PCD-88
INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website: