Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.



Similar documents
Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Battery Power Line. Battery-driven power tool system for orthopaedics and traumatology.

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Small Battery Drive. For orthopaedic trauma applications.

Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

Rebuild Instructions for and Transmission

Expert LFN. Lateral Femoral Nail.

How To Use A Phoenix Retrograde Femoral Nail

PERIPROSTHETIC IMPLANTS

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.

TFN Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

Technique Guide. Norian SRS Fast Set Putty. Calcium phosphate bone void filler.

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.

Step-by-step instructions:

Expert ALFN. Adolescent Lateral Femoral Nail.

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

DRAFT. Triathlon TS Knee System. Surgical Protocol. Version 1

Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis.

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue.

Titanium Wire with Barb and Needle. For canthal tendon procedures.

V-TEK IVP System 2.7 System 4.0

TRIGEN TAN and FAN Intramedullary Nails

Expert TN. Tibial Nail.

Zimmer Periarticular Proximal Tibial Locking Plate

TwinFix Cannulated Compression Screw

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

M/DN Femoral Interlocking & Recon Nail Intramedullary Fixation Surgical Technique

Round Housing with Side Ports

Expert HAN. Expert Hindfoot Arthrodesis Nail.

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

BODY-12, Door Handle - Removal, Installation, and Adjustment

Zimmer Small Fragment Universal Locking System. Surgical Technique

Build a Junior Solar Sprint Model Car Kit Materials: 1 PITSCO Ray Catcher Sprint Kit or Solar Made Junior Solar Sprint Kit 1 White Sheet of Plastic

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Drive shaft, servicing

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Polaris 9300 & 9400 Series Robotic Cleaner

INSTALLATION MANUAL. Contents JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. To the installing technician: CEILING BRACKET

Zimmer Periarticular Elbow Locking Plate System

Speed-Mat Rectangle Cutter

Slide the new steering column shaft through the steering column from the driver compartment.

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

M V Intake Manifold INSTALLATION INSTRUCTIONS

JOURNEYMAN400 User s Guide Guía del usuario Mode d emploi

TRS 090/105 Compressor. Repair Procedures

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Implant Extraction Guide Module One & Two

Solstice/Sky Water Pump Replacement

TRIGEN INTERTAN Intertrochanteric Antegrade Nail Surgical Technique. Table of Contents

CALIBRATION FOR LAL20X & LAL24X

Original Assembly Guide

The Drink-Aide The NEW look of independence

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

NCB Distal Femur System. Surgical Technique

COLIBRI II INSTRUCTIONS FOR USE. Universal and powerful battery system for a variety of applications

TransFx External Fixation System Large and Intermediate Surgical Technique

The information contained in this document is intended for healthcare professionals only.

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

LCP Compact Foot/Compact Hand.

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

ZERO-P VA. Variable angle zero-profile anterior cervical interbody fusion (ACIF) device SURGICAL TECHNIQUE

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

Owner s Manual Read and keep this manual. Patents World Wide

PFNA. With Augmentation Option.

Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection

apple Service Source PowerBook G4 (DVI) Updated 4 December Apple Computer, Inc. All rights reserved.

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

SUCTION & TUBING YANKAUER, POOLE, FRAZIER AND SIGMOID INSTRUMENTS PREMIUM CONNECTORED AND ECONOMY ROLL TUBING

#12 Professional Meat Grinders

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

Joplin Rebuild Instructions

STEEL-RITE II or III COMMERCIAL SECTIONAL DOOR Owner s Manual Supplement Model NOTICE TO USER

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

Arctic Leash Instruction Manual Alaskan Products Company LLC.


SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

AXLE SHAFTS - FRONT Pontiac Bonneville MODEL IDENTIFICATION DESCRIPTION & OPERATION TROUBLE SHOOTING REMOVAL & INSTALLATION

Guidance for implant removal. Straumann Dental Implant System

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

MatrixNEURO CMF Matrix

11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

chronos BOne VOid Filler Beta-Tricalcium Phosphate (b-tcp) bone graft substitute

Installation Instructions

1.8 CRANKSHAFT OIL SEALS

Assembly instructions VOSS quick connect system 246 NX

Transcription:

Technique Guide Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

Table of Contents Introduction Reamer/ Irrigator/ Aspirator (RIA) 2 Indications 4 Surgical Technique Preparation 5 Assembly 9 Reaming 18 Bone Harvesting 20 Reamer Head Exchange 22 Disassembly 24 Product Information Instruments 25 Power Equipment 31 Set List 32 Image intensifier control Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes

Reamer/Irrigator/Aspirator (RIA) Reaming with reduced risk of systemic complication Reduces intramedullary pressure Reduces potential for fat embolization Reduces heat generated Removal of infected tissue Fast, efficient reaming Time-saving, single-pass procedure Easier handling Sharp reamer heads for optimized cutting Reamer head Tube assembly Flow of irrigating fluid Bone marrow, morselized bone Autograft harvesting Familiar technique Irrigation fluid constantly cools reamer head and emulsifies marrow for easy evacuation Removal of marrow and bone through aspiration holes creates negative intramedullary pressure Sharp edges for efficient cutting Deep flutes to minimize clogging 2 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

Locking clip Drive shaft Drive shaft seal Aspiration of bone marrow and finely morselized bone Irrigation fluid gravity-fed into cannulation of drive shaft Mesh sized to capture morselized bone and bone marrow Graft filter 100 cc capacity Aspiration tube connected to suction canister Vacuum source creates suction Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 3

Indications The Synthes RIA System is intended for use in adults and adolescents (12-21 years) To clear the medullary canal of bone marrow and debris To effectively size the medullary canal for the acceptance of an intramedullary implant or prosthesis To harvest finely morselized autogenous bone and bone marrow for any surgical procedures requiring bone graft to facilitate fusion and/or fill bone defects. To remove infected and necrotic bone and tissue from the medullary canal in the treatment of osteomyelitis. 4 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

Preparation 1 Select appropriate length of tube assembly Instruments 314.745S RIA Tube Assembly, minimum 360 mm length, sterile 314.746S RIA Tube Assembly, minimum 520 mm length, sterile Select the appropriate length RIA tube assembly based on the length of the canal. Length of the canal Less than 350 mm Greater than 350 mm Tube assembly 360 mm 520 mm Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 5

Preparation 2 Confirm reaming diameter Instrument 351.717 Depth Gauge To estimate the canal diameter, position the image intensifier for an AP view of the limb at the level of the isthmus. Hold the radiographic depth gauge perpendicular to the limb and overlay the diameter tabs over the isthmus. Read the diameter on the tab that fills the canal. Repeat with an LM view. a. For reaming only, choose the implant diameter. Select a reamer head 1.0 mm to 1.5 mm larger than the chosen implant diameter. b. For bone harvesting, select a reamer head 1.0 mm to 1.5 mm larger than the canal diameter at the isthmus. Note: Measure in both AP and LM view. Caution: The distance of the depth gauge from the bone and the position of the receiver affect the diameter measurement Always place the depth gauge on the side of the limb closest to the receiver. Estimate the width as follows: Distance between depth gauge and bone a. 25 mm = 1 mm larger reading b. 50 mm = 2 mm larger reading c. 100 mm = 3 mm larger reading 6 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

3 Access canal and place reaming rod Instruments 351.706S 2.5 mm Reaming Rod with ball tip, 950 mm or 351.707S 2.5 mm Reaming Rod with ball tip and extension, 950 mm 393.10 Universal Chuck with T-Handle Gain access to the intramedullary canal using standard opening procedures and instrumentation for the chosen implant or entry point. Reduce the fracture, if present. Attach the universal chuck with T-handle to the reaming rod. Insert the reaming rod into the canal to the physeal scar. Verify its position with the image intensifier. Note: Ensure the reaming rod is centered in the canal in both AP and LM views. Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 7

Preparation 4 Confirm nail length (for reaming only) Instruments 351.717 Depth Gauge 351.719 Depth Gauge Extension Tube Assemble the extension tube to the depth gauge. Place the depth gauge assembly over the reaming rod. Note: The tip of the depth gauge assembly should be positioned at the desired location of the implant end. Caution: Use the depth gauge extension tube only with the 950 mm reaming rod. Determine the length of the canal. Choose implant length accordingly. Note: Consider dynamization when choosing implant length. 8 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

Assembly 1 Attach reamer head Instruments 314.745S RIA Tube Assembly, minimum 360 mm length, sterile 314.746S RIA Tube Assembly, minimum 520 mm length, sterile 352.250S Reamer Heads, for RIA 352.259S 12.0 mm 16.5 mm, sterile 352.261S Reamer Heads, for RIA 352.265S 17.0 mm 19.0 mm, sterile Select the appropriate reamer head. Insert it into the tube assembly. Caution: Reamer heads are sharp. Use the provided tip protector when attaching the reamer head to the tube assembly. Note: The reamer head is attached correctly when it can spin freely and is retained by the tube assembly. Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 9

Assembly 2 Attach drive shaft to tube assembly and reamer head Instruments 314.742 Drive Shaft, minimum 360 mm length 314.743 Drive Shaft, minimum 520 mm length Select the appropriate length drive shaft. Guide the tip of the drive shaft through the RIA tube assembly. Mate the hexagonal end of the RIA drive shaft with the hexagonal recess in the reamer head. Note: Visually check mating through the aspiration holes. 10 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

Note: The drive shaft is properly attached when the hex flats are not visible. The helix is also visible when properly attached. Note: The drive shaft hex is properly engaged in the reamer head when the retaining groove is hidden. Retaining groove Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 11

Assembly 2 Attach drive shaft to tube assembly and reamer head continued Push the outer sleeve of the RIA drive shaft forward to engage the body of the RIA tube assembly. Note: The drive shaft is properly attached when the tan plastic coupling shaft is no longer visible. 12 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

3 Attach locking clip Instrument 352.260S Locking Clip, for RIA, sterile Slide the locking clip onto the assembled RIA drive shaft and tube assembly. Note: The small ridge on the inner surface of the locking clip matches the groove between the drive shaft and the tube assembly. Rotate the locking clip until the circular notches on the locking clip align with the corresponding buttons on the tube assembly. Button on tube assembly Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 13

Assembly 4 Attach drive shaft seal Instrument 351.718S Drive Shaft Seal, for RIA, sterile Attach the drive shaft seal to the proximal end of the drive shaft. Drive shaft seal Note: The drive shaft seal is important to retain irrigation fluid in the cannulation of the drive shaft. 14 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

5 Attach drive unit to large quick coupling Instruments 530.605 Battery Reamer/ Drill 530.760 Large Quick Coupling, for Battery Power Line Select a cannulated drive unit that will deliver 3.5 Nm to 4.5 Nm of torque and 700 rpm to 900 rpm (standard drill speed). Use the cannulated quick coupling to attach the drive shaft to the drive unit. Caution: Do not use a reduction drive. Drills with a torque greater than 6 Nm must not be used. Power equipment designed for reaming must not be used. Alternative with Jacobs chuck with key Alternative instrument 530.730 Jacobs Chuck with key Use the Jacobs chuck to attach the drive shaft to the drive unit. Note: Insert the key into one hole of the chuck and tighten. Move the key to all subsequent holes on the chuck and tighten again. Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 15

Assembly 6 Connect irrigation Additional materials 1 2 liter container of irrigation fluid (e.g. isotonic 0.9% NaCl) Irrigation tubing set ( TURP, cysto-bladder, cystoscopy) Suspend a 1 or 2 liter container of irrigation fluid approximately one meter above the level of the RIA assembly. Attach spike end of tubing set to the irrigation container. Note: The clamp on the irrigation tubing set should be closed until reaming begins. Connect the opposite end of the irrigation tube to the irrigation port on the tube assembly. Note: The irrigation port is the smaller of the two ports and is indicated by an I. 16 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

7 Connect aspiration Additional materials Aspiration/suction tubing (minimum diameter = 1 4 or 6 mm) 2 5 liter suction canister Vacuum source Connect the aspiration tube to the aspiration port on the tube assembly. Note: The aspiration port is the larger of the two ports and is indicated by an A. Alternative for bone harvesting Instrument 352.229S Graft Filter for RIA, sterile Connect the graft filter to the aspiration port on the tube assembly. Connect the distal end of the graft filter to the aspiration tube. Note: Before use, ensure filter cap is tightened. Connect the other end of the aspiration tube to the suction canister. Connect the suction canister directly to the vacuum source. Note: Connect the aspiration tube directly to the suction canister to avoid a reduction in suction. Never connect several suction canisters in series. Start the vacuum source, if necessary. Note: Adjust to maximum level. Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 17

Reaming 1 Introduce RIA assembly into medullary canal Guide the reamer head over the reaming rod. Open the irrigation clamp to start liquid flow and ensure vacuum is operational. Note: Prior to insertion into patient s limb, visually verify flow of irrigation fluid at the tip of the reamer head. Advance the RIA assembly over the reaming rod until the aspiration holes are fully immersed into the bone. Check position on the image intensifier. A flow of blood and bone marrow becomes visible in the aspiration tube. Note: Flow of aspiration begins when aspiration holes are fully immersed in the bone. Aspiration holes Caution: Never ream when there is no irrigation/ aspiration. The irrigation/ aspiration cools the reamer heads and removes bone marrow and morselized bone from the medullary canal. Liquid flow is crucial for proper system performance. 18 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

2 Ream Begin reaming, using a gradual advance/ retract technique. Slowly advance 20 30 mm and then retract 50 80 mm allowing the irrigation fluid to flow in front of the reamer head. Advance the assembly until resistance is felt, then repeat. Note: An insufficient irrigation volume may lead to clogging. To prevent clogging, avoid rapid advancement of the assembly. Caution: Periodically check that the reaming aspirate is flowing through the tube and into the suction canister. Stop reaming if there is no flow. After the reamer head reaches the desired depth, withdraw the RIA assembly while maintaining rotation of the drill. Note: Reverse the drill if advancement of the reamer becomes difficult. Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 19

Bone Harvesting Note: When deciding to harvest autogenous graft, the patient s history, bone quality, physiological condition and compliance must be taken into account. 1 Turn off irrigation and aspiration Instrument 352.229S Graft Filter, for RIA, sterile Stop irrigation after withdrawing the RIA assembly from the canal. Turn off suction, or clamp the suction tubing. Disconnect the filter canister from the lid and move it to the back table. 2 Prepare graft Hold the graft filter vertically. Compress the bone graft by gently pushing down on the plunger. Estimate the volume of bone graft with the scale on the outer canister. 20 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

3 Remove graft from filter With the plunger inserted, invert the filter. Remove the inner filter from the canister. Caution: When handling, do not hold the opening downward as there is a risk of dropping the graft material. Hold the inner filter over an appropriate container. Position the inner filter vertically. Push the bone graft out of the filter with the plunger. Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 21

Reamer Head Exchange 1 Disengage drive shaft Intraoperative RIA reamer head exchange is determined by surgeon preference. Place reamer head tip protector over reamer head and disengage drive shaft. The tip protector is provided with each RIA reamer head. Caution: Reamer heads are sharp. finger Align reamer head in aspiration hole. The reamer head is correctly positioned when one reamer head finger is visible in the aspiration hole. finger Correct alignment Incorrect alignment 22 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

2 Remove reamer head Insert a 3.5 mm or 4.0 mm hex screwdriver into the aspiration hole at a 30 45 angle to collapse the reamer head finger. Rotate screwdriver away from reamer head to release head. Replace with sterile reamer head. Note: Dispose of reamer head. Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 23

Disassembly 1 Remove drive shaft Remove and dispose of the irrigation/ aspiration tubing and locking clip. Push the outer sleeve of the drive shaft toward the body of the RIA tube assembly. Keep the outer sleeve in a forward position while withdrawing the drive shaft from the body of the tube assembly. Remove the drive shaft from the RIA tube assembly. Note: Dispose of the tube assembly and reamer head. Remove and dispose of the drive shaft seal. 24 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

Single-use Instruments Reamer Heads Conical tip helps centralize reamer Deep flutes minimize clogging Sharp edges for cutting efficiency Diameters: 12 mm 19 mm in 0.5 mm increments Stainless steel Sterile packed Attaches to RIA tube assemblies Diameter Diameter (mm) (mm) 352.250S 12.0 352.258S 16.0 352.251S 12.5 352.259S 16.5 352.252S 13.0 352.261S 17.0 352.253S 13.5 352.262S 17.5 352.254S 14.0 352.263S 18.0 352.255S 14.5 352.264S 18.5 352.256S 15.0 352.265S 19.0 352.257S 15.5 RIA Tube Assemblies Two lengths available (attach to corresponding drive shafts) Sterile packed Length (mm) 314.745S 360 314.746S 520 2.5 mm Reaming Rods with ball tip Length (mm) 351.706S 950 351.707S 950, with extension 351.708S 1150 Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 25

Single-use Instruments 351.718S Drive Shaft Seal, for RIA (2/ pkg.) Elastomeric seal Minimizes flow of irrigation fluid into drive unit Sterile packed 352.229S Graft Filter, for RIA Collects finely morselized bone chips and marrow Capacity: 100 cc Graduations for estimating volume Plunger for easy removal of graft Sterile packed 352.260S Locking Clip, for RIA Secures attachment between drive shaft and tube assembly Sterile packed 26 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

Additional Materials Irrigation Fluid Bag 1 2 liters for reaming 3 liters minimum for harvesting Suction Canister 2 liters minimum for reaming 3 liters minimum for harvesting Irrigation Tubing Clip to control liquid flow Spike to connect irrigation fluid bag ( TURP, cysto-bladder, cystoscopy) Aspiration/ Suction Tubing Minimum diameter: 1 4, or 6 mm, allowing tight seal around port Vacuum Source Wall suction or portable suction Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 27

Instruments 314.742 Drive Shaft, minimum 360 mm length 314.743 Drive Shaft, minimum 520 mm length 351.05 Tissue Protector 351.717 Depth Gauge 351.719 Depth Gauge Extension Tube 393.10 Universal Chuck with T-Handle 28 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

Optional Instruments 03.010.036 12.0 mm Cannulated Drill Bit, large quick coupling, 190 mm 03.010.040 12.0 mm Cannulated Awl 03.010.115 3.2 mm Guide Wire, 290 mm 351.02 Small Awl, 210 mm length 351.782 Holding Forceps Hand Reamers, 450 mm length 351.92 6.0 mm 351.93 7.0 mm 351.94 8.0 mm Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 29

Optional Instruments 355.006 Medullary Tube Note: Single sterilization only. Do not use with 3.0 mm Reaming Rod with offset ball tip (351.71) 357.403 6.0 mm/10.0 mm Stepped Cannulated Drill Bit, large quick coupling, 435 mm 30 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

Power Equipment 530.605 Battery Reamer/Drill 530.730 Jacobs Chuck with Key, for Battery Power Line 530.760 Large Quick Coupling, for Battery Power Line Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 31

Reamer/Irrigator/Aspirator Instrument Set (105.309) Graphic Case 690.308 Reamer/ Irrigator/ Aspirator Instrument Set Graphic Case Instruments 314.742 Drive Shaft, minimum 360 mm length, for use with Reamer/ Irrigator/ Aspirator (RIA) 314.743 Drive Shaft, minimum 520 mm length, for use with Reamer/Irrigator/Aspirator (RIA), 2 ea. 351.05 Tissue Protector 351.717 Depth Gauge 351.719 Depth Gauge Extension Tube 393.10 Universal Chuck with T-Handle Note: For additional information, please refer to package insert. For detailed cleaning and sterilization instructions, please refer to http://us.synthes.com/medical+community/cleaning+and+sterilization.htm or to the below listed inserts, which will be included in the shipping container: Processing Synthes Reusable Medical Devices Instruments, Instrument Trays and Graphic Cases DJ1305 Processing Non-sterile Synthes Implants DJ1304 32 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guide

Also Available Single-use Items 314.745S Reamer/ Irrigator/ Aspirator Tube Assembly, minimum 360 mm length, sterile, for use with RIA drive shaft (314.742) 314.746S Reamer/ Irrigator/ Aspirator Tube Assembly, minimum 520 mm length, sterile, for use with RIA drive shaft (314.743) 351.706S 2.5 mm Reaming Rod with ball tip, 950 mm, sterile 351.707S 2.5 mm Reaming Rod with ball tip and extension, 950 mm, sterile 351.708S 2.5 mm Reaming Rod with ball tip, 1150 mm, sterile 351.718S Drive Shaft Seal, for Reamer/ Irrigator/ Aspirator, sterile (2/pkg.) 352.229S Graft Filter, for Reamer/ Irrigator/ Aspirator, sterile 352.260S Locking Clip, for Reamer/ Irrigator/ Aspirator, sterile Reamer Heads, for Reamer/ Irrigator/ Aspirator, sterile Diameter Diameter (mm) (mm) 352.250S 12.0 352.258S 16.0 352.251S 12.5 352.259S 16.5 352.252S 13.0 352.261S 17.0 352.253S 13.5 352.262S 17.5 352.254S 14.0 352.263S 18.0 352.255S 14.5 352.264S 18.5 352.256S 15.0 352.265S 19.0 352.257S 15.5 Instruments 03.010.036 12.0 mm Cannulated Drill Bit, large quick coupling, 190 mm 03.010.040 12.0 mm Cannulated Awl 03.010.115 3.2 mm Guide Wire, 290 mm 351.02 Small Awl, 210 mm length 351.15 Flexible Shaft Handle, quick coupling, cannulated 351.782 Holding Forceps 351.92 6.0 mm Hand Reamer, 450 mm length 351.93 7.0 mm Hand Reamer, 450 mm length 351.94 8.0 mm Hand Reamer, 450 mm length 352.040 5.0 mm Flexible Shaft, 470 mm 352.050 7.0 mm Reduction Head, straight 352.055 7.0 mm Reduction Head, angled 355.006 Medullary Tube 357.403 6.0 mm/10.0 mm Stepped Cannulated Drill Bit, large quick coupling, 435 mm 360.243 Handle, for 12.0 mm Tapered Intramedullary Reduction Tool 360.244 Shaft, for 12.0 mm Tapered Intramedullary Reduction Tool Power Equipment 511.73 Jacobs Chuck with Key 511.761 Large Quick Coupling 530.100 Power Drive 530.605 Battery Reamer/ Drill 530.730 Jacobs Chuck with key, for Battery Power Line 530.760 Large Quick Coupling, for Battery Power Line Recommended Additional Sets 115.545 Accessory Instrument Set for IM Nail Insertion 150.060 Flexible Reamer Set for IM Nails 150.16 ComPact Air Drive II Set 150.119 Battery Power Line Set 105.957 Power Drive Set 105.955 Small Battery Drive Set Synthes

Synthes (USA) 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322 Fax: (610) 251-9056 Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185 www.synthes.com 2005 Synthes, Inc. or its affiliates. All rights reserved. Synthes is a trademark of Synthes, Inc. or its affiliates. Printed in U.S.A. 11/11 J4352-H