SIMATIC. PC Adapter USB. Preface, Contents Properties of the PC Adapter USB 1. Package Components



Similar documents
SIMATIC. PC Adapter USB. Preface, Contents Properties of the. PC Adapter USB. Package Components 2

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

SIMATIC. S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis. Introduction. Preparation. Learning units 3. Further information 4.

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Universal Serial Bus (USB) to DH-485 Interface Converter

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

SIMATIC. Programming device SIMATIC Field PG M2. Introduction. Description 2. Application Planning 3. Setting up and connecting 4. Startup 5.

Validity 1. Installation 2 SIMATIC. WinCC flexible Tag simulator Update 1. Readme

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual

TX OPEN RS232/485 module

USB-to-Data Highway Plus Cable

Kvaser Mini PCI Express User s Guide

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

Digital input modules

SIMATIC HMI. WinCC flexible 2008 Getting Started - First-Time Users Getting Started. Printout of the Online Help 06/2008 A5E

CompactLogix Power Supplies Specifications

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

1 Application Description Objective Goals... 3

Automation License Manager

Waveguide Access Point WGA631. Product Guide

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Modular I/O System Analog and Digital Interface Modules

Safety Precautions WARNINGS

SIMATIC. SIMATIC Logon. User management and electronic signatures. Hardware and Software Requirements. Scope of delivery 3.

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

MINI MCR-SL-R-UI(-SP)

Installation instructions CAN/RS232-USB interface CANfox EC / / 2010

USB Fieldbus Interface

Configuration limits for products of the SIMATIC NET PC Software V12 SIMATIC NET. Configuration limits for products of the SIMATIC NET PC Software V12

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual

MADRIX NEO Quick Start Guide & User Manual

PCAN-ISA. CAN Interface for ISA. User Manual

PCAN-USB CAN Interface for USB. User Manual. Document version ( )

1-Port R422/485 Serial PCIe Card

MACTek Corporation. USB HART Interface. Users Manual

SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules

PROFINET CPU 314C-2 PN/DP, PN/DP, PN/DP, PN/DP: Configuring the PROFINET interface

USB VoIP Phone Adapter. User s Manual

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3. Simatic. Readme. Readme

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

AXIS T81B22 DC 30W Midspan

NX safety stand-alone

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Operating Instructions (Compact) Edition 02/2006

A6210 WiFi USB Adapter ac USB 3.0 Dual Band User Manual

SIMATIC. ET 200S distributed I/O 2AI U ST analog electronic module (6ES7134-4FB01-0AB0) Preface. Properties 1. Parameters 2.

4-Port Pocket. USB KVM Switch with USB 2.0 Hub

R60 USB to CAN interface Manual (1.5 EN)

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

User s Manual. Powerline 200M Ethernet Bridge

AXIS 5810 A Bluetooth Print Plug. Quick Start

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

1788 Linking Device Specifications

User Manual Revision English

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.

is then retained absolutely without interruption.

User Manual Revision English

ABB Drives. User s Manual HTL Encoder Interface FEN-31

PCS0100en Persy Control Services B.V. Netherlands

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

RS 485 Repeater SIMATIC. RS 485 Repeater. Preface 1. Introduction. Description 3. Installation 4. Connecting. Technical data 6.

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

User's Guide. Integrating Sound Level Datalogger. Model Introduction

SIMATIC NET. S7-CPs for PROFIBUS. CP Basic. Manual Part B3

Telephone- and leased line modem for industrial applications TD-36

2-Port RS232/422/485 Combo Serial PCI Card

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

PT Mbps Powerline Adapter. User Guide

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

SIMATIC The Process Device Manager Manual Edition 12/2004 A5E

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Portable BACnet /IP to MS/TP Router

Creating the project and hardware. TIA Portal. SIMATIC Creating the project and hardware. Introduction to the TIA Portal 1. Creating a project

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

USB 2.0 to 10/100Mbps Ethernet Adapter UE User Manual

User Manual Revision English

SYSTEM DESCRIPTION Termination Boards

Powerline 1200 User Manual

Wireless-N. User Guide. PCI Adapter WMP300N (EU) WIRELESS. Model No.

L5354 ControlNet Communications Interface

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

1. SAFETY INFORMATION

Patch management and security. updates SIMATIC. Process Control System PCS 7 Patch management and security updates. Preface 1

Transcription:

s SIMATIC Manual Preface, Contents Properties of the 1 Package Components 2 Requirements for Operation 3 Hardware Design of the 4 Working with the 5 on the MPI/DP Network 6 Firmware Update 7 Error Diagnostics 8 Technical Data 9 Appendix 10 Index 10/2007 A5E01134250-01

Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring to property damage only have no safety alert symbol. The notices shown below are graded according to the degree of danger.!!! Danger indicates that death or severe personal injury will result if proper precautions are not taken. Warning indicates that death or severe personal injury may result if proper precautions are not taken. Caution with a safety alert symbol indicates that minor personal injury can result if proper precautions are not taken. Caution without a safety alert symbol indicates that property damage can result if proper precautions are not taken. Qualified Personnel Prescribed Usage Notice indicates that an unintended result or situation can occur if the corresponding notice is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notices in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Note the following:! Warning This device and its components may only be used for the applications described in the catalog or the technical description, and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. Trademarks All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Automation and Drives Postfach 4848 90437 NÜRNBERG GERMANY A5E01134250-01 10/2007 Copyright Siemens AG 2007 Technical data subject to change

Preface Purpose of the Manual This manual gives you a complete overview of. It guides you when installing and commissioning the software and hardware. It also describes the operation and hardware installation requirements, as well as, the connection of the Adapter to MPI/DP networks. This manual is intended for the programmers and for those responsible for configuring, commissioning, and servicing automation systems. Required Basic Knowledge You require a general knowledge in the field of automation engineering to be able to understand this manual. In addition, you should know how to use computers or devices with similar functions (e.g. programming devices) under the Microsoft Windows operating systems. Where is this Manual valid? This manual is valid for the product with order number: 6ES7972-0CB20-0XA0. A5E01134250-01 iii

Preface Certification have the following certification: Underwriters Laboratories, Inc.: UL 60950 registered and Canadian Standard C22.2 No. 60950 (Information Technology Equipment) CE Labeling fulfil the requirements and protection guidelines of the following EU directives: EC Directive 89/336/EWG "EMC directive" CTick Mark is compliant with requirements of the AS/NZS 3548 (Australian and New Zeeland) standard. Further Support If you have any technical questions, please get in touch with your Siemens representative or agent responsible. You will find your contact person at: http://www.siemens.com/automation/partner You will find the directory to offers on technical documentation for each SIMATIC products and systems under: http://www.siemens.de/simatic-tech-doku-portal You will find the Online catalog and the Online ordering system under: http://mall.automation.siemens.com/ Training Centers Siemens offers a number of training courses to familiarize you with the automation system SIMATIC S7 automation system. Please contact your regional training center or our central training center in D 90327 Nuremberg, Germany for details: Telephone: +49 (911) 895-3200. Internet: http://www.sitrain.com iv A5E01134250-01

Preface Technical Support You can get Technical Support for all A&D products Via the Web formula for the Support Request http://www.siemens.de/automation/support-request Phone: + 49 180 5050 222 Fax: + 49 180 5050 223 You can find more information on our Technical Support on the Internet under http://www.siemens.de/automation/service Service & Support on the Internet In addition to our documentation, we offer our Know-how online on the internet at: http://www.siemens.com/automation/service&support where you will find the following: The newsletter, which constantly provides you with up-to-date information on your products. The right documents via our Search function in Service & Support. A forum, where users and experts from all over the world exchange their experiences. Your local representative for Automation & Drives. Information on field service, repairs, spare parts and more under "Services". A5E01134250-01 v

Preface vi A5E01134250-01

Contents 1 Properties of the 1-1 1.1 Function... 1-1 1.2 Performance specifications... 1-2 2 Package Components 2-1 3 Requirements for Operation 3-1 3.1 Software requirements... 3-1 3.2 Hardware requirements... 3-1 4 Hardware Design of the 4-1 4.1 Connections... 4-1 4.2 LEDs on the... 4-2 4.3 Power supply... 4-3 4.4 MPI/DP interface... 4-5 4.5 USB interface... 4-6 5 Working with the 5-1 5.1 Technical safety notes... 5-1 5.2 Installation of the software... 5-1 5.3 Configuring the PG / PC interface... 5-2 5.4 Connecting the... 5-3 6 on the MPI/DP Network 6-1 6.1 General... 6-1 6.2 Use as a stand-alone system... 6-1 6.3 Use in a networked system... 6-2 7 Firmware Update 7-1 8 Error Diagnostics 8-1 9 Technical Data 9-1 10 Appendix 10-1 Index 10.1 Certificates, Directives and Declarations... 10-1 10.2 Certification for the USA, Canada and Australia... 10-3 Index-1 A5E01134250-01 vii

Contents viii A5E01134250-01

1 Properties of the The is compatible with USB V1.1 and satisfies the requirements for "Low-Powered USB devices. The SIMATIC supports the energy saving mode (hibernate mode). 1.1 Function The SIMATIC connects a PC to the MPI/DP interface of an S7/M7/C7 system via USB. A slot is not required in the PC, which means that the adapter can also be used for non-expandable PCs such as notebooks. USB MPI/DP Fig. 1-1: Configuration with Note Only one can be used on a PC. A5E01134250-01 1-1

Properties of the 1.2 Performance specifications The can be used on MPI and PROFIBUS networks. Starting at firmware V1.1, the can also be operated on homogeneous PPI networks. The following table shows the transmission rates and network types supported by the. Tabelle 1 : Busprofile und Übertragungsgeschwindigkeiten Transmission rate MPI PPI PROFIBUS DP Standard Universal Userdefined 9.6 kbps - 19.2 kbps 45.45 kbps - - - 93.75 kbps - - 187.5 kbps 500 kbps - - 1.5 Mbps - Other performance features Automatic bus profile detection Up to 16 communication connections, of those up to 4 slaves (DP/T connections) Routing support As of firmware V1.3, the DPV1 Standard slaves is supported through - Slave address assignment - Device diagnosis - Read/write data record 1-2 A5E01134250-01

2 Package Components The SIMATIC package includes: One "SIMATIC Software CD containing the software and documentation One USB cable (5 m) One MPI cable (0.3 m) The MPI cable can be used to connect the to MPI, homogeneous PPI or PROFIBUS (DP) networks. Spare parts Spare parts USB cable (5 m) MPI cable (0.3 m) Order number A5E00276884 A5E00164946 You can forward your spare parts orders to your local Siemens partner. Supplies (not included in the ) To operate the to MPI/DP interfaces which do not have a 24V supply voltage, you can order an external power supply (order number: 6ES7 972-0CA00-0XA0). A5E01134250-01 2-1

Package Components 2-2 A5E01134250-01

3 Requirements for Operation 3.1 Software requirements One of the following operating systems must be installed on the PC in order to be able to operate the SIMATIC : Windows 2000 Windows XP Professional Windows XP Home Windows Server 2003 Standard Edition Windows Vista and a SIMATIC software package that communicates via MPI (for example, STEP 7) To operate the on a PPI network, you also need the STEP 7-Micro/Win32 SW package. 3.2 Hardware requirements You require a PC with a USB interface and a CD ROM drive. A5E01134250-01 3-1

Requirements for Operation 3-2 A5E01134250-01

4 Hardware Design of the 4.1 Connections Connections or displays on the : USB interface LEDs: USB Power MPI MPI/DP interface A5E01134250-01 4-1

Hardware Design of the 4.2 LEDs on the The LEDs on the indicate the following: Name Color Meaning USB green Lights up when the is connected to the USB and the operating system of your PC is in normal operating mode. This LED is not lit when the PC is in standby or idle mode. The LED flickers when data are being transferred. POWER green Lights up when the is supplied with the necessary power. Flashes when a hardware fault is detected. MPI green Lights up when the is connected to the MPI/DP network and is operational. The LED flashes when data are transferred on the MPI/DP network. The LED is off when no firmware has been loaded in the. The LED displays for error states are described in Chapter 8 Error Diagnostics.. 4-2 A5E01134250-01

Hardware Design of the 4.3 Power supply The is supplied with power by the automation system via the MPI cable or alternatively via the external power supply (see Section 2) included in the delivery. It requires 24 V (see the technical data).! Caution Always connect the to power supplies with limited power or NEC Class 2. UL cable, AWM 2464, 80 C, 300 V, 28 AWG, VW-1 Fig. 1: MPI cable, 0.3 m with 9-pin sub-d connectors.! Warning Always use the MPI cable included with your. A5E01134250-01 4-3

Hardware Design of the Shield 1 2 3 4 5 6 7 8 9 NC NC NC M24V LTG_B RTSAS M5V P24V LTG_A Shield NC NC NC 1 2 3 4 5 6 7 8 9 9-pin subminiature D 9-pin subminiature D Fig. 2: MPI cable (0.3 m) 9 8 RTSPG LTG_A USBV1.1 12MBit/s P5 D- D+ M5 1 2 3 4 USB Electronics 5V 1M NC NC 3 4 6 5 1 LTG_B RTSAS P5V M5V M 7 P24V USB POWER MPI +3,15V +1,95V M 24V DC 2 M24V Shield PC potential area AS potential area Fig. 3: Block diagram The MPI/DP and USB interfaces of the are electrically isolated within a safety extra low-voltage circuit (SELV). It can therefore be operated directly on ungrounded S7/M7/C7 systems. 4-4 A5E01134250-01

Hardware Design of the 4.4 MPI/DP interface Pin assignment Pin assignment of the MPI/DP interface: Description of signals Pin no. Short name Meaning Input / Output 1 NC Not connected 2 M24V Zero volt of the 24 V power supply, Input provided by the electronic DC/DC circuit of the adapter (AS potential range) 3 LTG_B Data line B Input / Output 4 RTS_AS RTSAS control signal for receive data Input current. The signal is active 1 when the directly connected AS is transmitting data. 5 M5V Reference potential of the MPI/DP Input interface for the RTS_AS and RTS_PG signals 6 P5V Not connected 7 P24V Zero volt of the +24 V power supply, Input provided by the electronic DC/DC circuit of the adapter (AS potential range) 8 LTG_A Data line A Input / Output 9 RTS_PG Adapter s RTS output signal. The signal is Output 1 when the adapter is transmitting data. The signal is not contained in the 0.3 m MPI cable! Shielding on connector housing* * The shielding is interconnected with the USB interface via the adapter electronic module. A5E01134250-01 4-5

Hardware Design of the 4.5 USB interface Interface pin assignments Top view of the USB socket: Description of signals Pin no. Signal 1 +5V Power supply 2 -Data - Differential signal 3 + Data + Differential signal 4 Ground Ground! Caution Operating several USB devices on your PC may effect the data transmission rates. To obtain optimum communication performance with the automation system, disconnect USB devices that are not required. 4-6 A5E01134250-01

5 Working with the 5.1 Technical safety notes Qualified personnel The device should only be accessed by qualified personnel. Qualified personnel as referred to in safety guidelines in this documentation are persons who are authorized to commission, ground, and tag circuits, equipment, and systems in accordance with established safety practice. Use as intended:! Warning The equipment/system or the system components may only be used for the applications described in the catalog or the technical description, and only in combination with the equipment, components, and devices of other manufacturers as far as this is recommended or permitted by Siemens. The product will function correctly and safely only it is transported, stored, set up, and installed as intended, and operated and maintained with care. 5.2 Installation of the software Setup runs the installation of the software automatically after you insert the CD. If the autorun function is disabled, proceed as follows: 1. Insert the CD for your into the CD-ROM drive. 2. Open the root directory of this drive. 3. Double-click "setup.exe" to run Setup. Setup is menu controlled. Please note the readme file in the root directory on the CD for information on the installation and use of your. A5E01134250-01 5-1

Working with the 5.3 Configuring the PG / PC interface You are prompted to configure the PG / PC interface during setup. 1. Check the PG / PC interface dialog box for the following interface settings. The following items should be available in the selection list: - PC Adapter (Auto) (only when STEP 7 is installed) - PC Adapter (MPI) - PC Adapter (PPI) (only if STEP 7-Micro/Win has been installed) - PC Adapter (PROFIBUS) If this is not so: - Click "Select..." to add / remove interfaces. This opens a dialog box for installing / uninstalling interfaces. - Select the PC Adapter module from the list and install it. Click "Close" to exit the dialog box. 2. Now select the interface configuration in the PG / PC interface dialog box with which you intend to communicate, for example, the PC Adapter (MPI). Click "Properties". 3. In the Properties dialog box of the PC Adapter (see table below), check if the parameter settings fit your system configuration, and change the settings if necessary: Interface configuration PC Adapter (Auto) PC Adapter (MPI) PC Adapter (PPI) PC Adapter (PROFIBUS) check in the tab Auto-detection of the bus profile MPI PPI PROFIBUS 4. The properties dialog box for the PC Adapter (MPI) appears. Select the local connection tab. Set USB in the COM port selection box (or connection to:). 5. Close this properties dialog box by clicking "OK". 6. Click OK to close the PG / PC interface dialog box. 7. A warning appears if you have changed an access path during the configuration. Acknowledge the message with OK to accept the changes. 5-2 A5E01134250-01

Working with the 5.4 Connecting the Connecting to the PC 1. Insert the supplied USB cable into the USB port of your PC. 2. Plug the other end of the USB cable into. Connecting to the PLC 1. Insert the supplied MPI cable into the and screw-tighten it. 2. Insert the other end of the MPI cable into the MPI port of your CPU and screwtighten it. Note The adapter and the S7/M7/C7 system each represent a network node. In networks consisting of two nodes (adapter and S7/M7/C7 system), the adapter is connected directly to the socket of the S7/M7/C7 system. When the network contains more than two nodes, the adapter should be connected to the "PG socket of a PROFIBUS connector (SINEC L2 bus connector). You do not need to change the settings of the terminating resistors. Caution Do not connect the SIMATIC to the automation system with any other cable than the supplied MPI cable. A5E01134250-01 5-3

Working with the 5-4 A5E01134250-01

6 on the MPI/DP Network 6.1 General A maximum of 32 nodes can be connected to an MPI/DP network segment. The total cable length may not exceed 50 meters. Several network segments can be connected together using RS485 repeaters, thus allowing a maximum number of 127 network nodes. The maximum data transmission rate in the MPI/DP network is 12 Mbps. The supports transmission rates up to 1.5 Mbps.! Warning An extension cord should not be interconnected between the adapter and the S7/M7/C7 system. 6.2 Use as a stand-alone system The following illustration shows the connection to a stand-alone system (2 network nodes). A5E01134250-01 6-1

on the MPI/DP Network 6.3 Use in a networked system The following illustration shows the connection in a networked S7 system (MPI/DP network containing 2 or more network nodes). S7x S7y 3) Adapter 3) Bus connector with PG socket 4) PROFIBUS bus connector PROFIBUS bus cable 4) Once you have completed the installation and configuration of the PG / PC interface, you can communicate with the PLC using your SIMATIC software package.. 6-2 A5E01134250-01

7 Firmware Update The firmware of the can be updated, for example, when new functions have been added. How to update the firmware: Download the latest firmware and the firmware update utility from the Internet: http://www.siemens.com/automation/service&support Search the product support area for the term ". Download the self-extracting EXE file containing the available firmware and the firmware update utility to your PC. Unzip the files to a local drive, then run the *.exe file to update your PC Adapter USB firmware. Follow the instructions on the screen. Please read the readme file in the "Firmware" folder of the firmware update utility. It contains notes about the installation and use of the latest firmware. Note The latest firmware and the firmware update utility is available on your "SIMATIC Software " CD in the "Firmware" folder at the time of delivery. A5E01134250-01 7-1

Firmware Update 7-2 A5E01134250-01

8 Error Diagnostics The information in the following section offers support to help you locate and perhaps correct common errors by yourself. Error / cause The power LED is not lit MPI cable not connected The PLC is switched off Hardware error The USB LED is not lit USB cable not connected PC and are in energy saving mode (hibernate mode). The PC can not find the To avoid or correct errors Connect the MPI cable Switch on the PLC Inform Customer Support Connect the USB cable permitted operating mode Check your driver installation, and install it if necessary The MPI LED is not lit The MPI cable not connected Connect MPI cable Firmware not loaded Start the supplied firmware update utility and check if the firmware is loaded. None of the LEDs is lit MPI cable not connected Connect the MPI cable The required 24 V DC are not wired to the MPI Check the wiring socket Hardware error Inform Customer Support The power LED flashes continuously Hardware error If the POWER LED of the device continues to flash continuously even after pulling and plugging the MPI cable several times, the device is defective and should be replaced. A5E01134250-01 8-1

Error Diagnostics 8-2 A5E01134250-01

9 Technical Data Order no. 6ES7972-0CB20-0XA0 Dimensions Approx. 105 x 58 x 26 mm Weight Approx. 250 g Interfaces to S7 / M7 / C7 RS485 (max. 1.5 Mbps) to PC USB (12 Mbps) Power supply 24 V DC (SELV) (18V.. 30 V DC) (via MPI interface) Power consumption 50 ma (typically) / 100 ma (max.) Inrush current Imax. 700 ma; 8µs Safety Safety class Safety class III conforming to IEC 60950 Safety requirements IEC 60950 corresponds to DIN/EN 60950 Degree of protection IP 20 Electromagnetic compatibility (EMC Noise emission Limit value class B according to EN 55022 Noise immunity on signal lines 2 kv (according to IEC 61000-4-4; burst; length > 3m) Immunity to discharge of static electricity 6 kv, contact discharge (according to IEC 61000-4-2 (ESD) 8 kv, air gap discharge (according to IEC 61000-4-2 RF immunity 10 V/m 80-1000 MHz, 80% AM (to IEC 61000-4-3) 10 V/m 900 MHz, 1.89 GHz, 50% ED (to IEC 61000-4-3) RF conductance 10 V 9 khz - 80 MHz (to IEC 61000-4-6) Climatic conditions Temperature Operation Storage / shipping Tested according to DIN EN 60068-2-2, DIN IEC 60068-2-1 +0 C to +60 C, temperature change max. 10 K/h 20 C to +60 C, temperature change max. 20 K/h Relative humidity Tested according to DIN IEC 60068-2-3, DIN IEC 60068-2-30, DIN IEC 60068-2-14 Operation Storage / shipping 5% to 80% at 25 C (no dewing) 5% to 95% at 25 C (no dewing) A5E01134250-01 9-1

Technical Data Mechanical ambient conditions Vibration Operation Storage / shipping Shockproof Operation Storage / shipping Tested according to DIN IEC 60068-2-6 10 to 58 Hz: amplitude 0.075 mm, 58 to 500 Hz: acceleration 9.8 m/s 5 to 9 Hz: amplitude 3.5 mm, 9 to 500 Hz: acceleration 9.8 m/s Tested according to DIN IEC 60068-2-27/29 150 m/s, 11 ms, 100 shocks 250 m/s, 6 ms, 1000 shocks 9-2 A5E01134250-01

10 Appendix 10.1 Certificates, Directives and Declarations Notes on the CE Label The following applies to the SIMATIC product described in this documentation: EMC directive This product fulfills the requirements for the EC directive 89/336/EEC on electromagnetic compatibility and the following fields of application apply according to this CE label: Fields of application Residential and commercial areas and small businesses. Requirement for Noise emission Noise Immunity EN 61000-6-3: 2001 EN 61000-6-1: 2001 Industry EN 61000-6-4: 2001 EN 61000-6-2: 2001 Declaration of Conformity The EC declarations of conformity and the documentation relating to this are available to the authorities concerned, according to the above EC directive, from: Siemens AG Automation and Drives A&D AS RD 4 PO Box 1963 D 92209 Amberg, Germany Phone: +49 9621 80 3283 Fax: +49 9621 80 3278 A5E01134250-01 10-1

Appendix Observing the installation guidelines The installation guidelines and notes on safety given in the manual must be observed at startup and during operation. Connecting I/O devices Noise immunity when connected to industrial standard PC conforms with the requirements of EN 61000-6-2:2001. 10-2 A5E01134250-01

Appendix 10.2 Certification for the USA, Canada and Australia One of the following markings on a device is indicative of the corresponding approval: Underwriters Laboratories (UL) according to the UL 60950 standard, and Canadian standard C22.2 No. 60950 (I.T.E) or to UL508 and C22.2 No. 142 (IND.CONT.EQ) UL Recognition Mark EMC Australia and New Zealand This product meets the requirements of the AS/NZS 3548 Standard. A5E01134250-01 10-3

Appendix 10-4 A5E01134250-01

Index B Busprofile 1-2 C Compatibility 1-1 Configuration with the 1-1 Connecting to the PC 5-3 Connecting to the PLC 5-3 Connections 4-1 D Description of signals 4-5 E Energy saving mode 1-1 Error diagnostics 8-1 F Firmware Update 7-1 H Hardware requirements 3-1 M MPI 4-2 MPI cable 2-1 MPI/DP interface 4-5 MPI/DP network 6-1 O Operating state LEDs 4-2 P Package components 2-1 Performance specifications 1-2 POWER 4-2 Power supply 4-3 S Software installation 5-1 Software requirements 3-1 T Technical data 9-1 Technical safety notes 5-1 Transmission rate 1-2, 6-1 U USB 4-2 USB cable 2-1 USB interface 4-6 A5E01134250-01 1

Index 2 A5E01134250-01