INDEPENDENT HOBS WITH HIC ELECTRONIC CONTROL



Similar documents
B/S/H/ Error codes and service programmes PH

Gas Touch. Built-in Gas Hobs with Electronic Control and Touch User Interface

INSTRUCTION FOR THE USER

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

NC-12 Modbus Application

EK908FHL - Thermostat for floor heating

ABB i-bus KNX Fan Coil Controller FC/S 1.1

IH E Sigma Island 90

Drayton Digistat +2RF/+3RF

Fused Spur Time Switch

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

Applied Electronics. Commercial Dimming System UPDATE NOTICE

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Single Channel Loop Detector

Stove Guard Kit User Manual

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Comfort 250, 252 Operator System for Garages Anriebssystem für Garagen Anriebssystem für Garagen Anriebssystem für Garagen Anriebssystem für Garagen

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

How To Use A Power Supply On A Powerline 2.2 (Ai)

SERVICE MANUAL REFRIGERATION

SCORPION. micron security products

Manual for Fire Suppression & Methane Detection System

MIGRATION HEIGHT-ADJUSTABLE DESKS. Troubleshooting Guide

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Thermo Top - Troubleshooting Tree

GSM HOME SECURITY SYSTEM

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46

User Manual THR840DUK Digital Thermostat

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

14. Troubleshooting Guide

MP-4000 Alarm List (Software version or later)

Wok à induction Induktion Wok Induction WOK Wok aan inductie

Installation and Operation Back-UPS 1250, 1300, 1500

Secure Keypads for access control

*.ppt 11/2/ :48 PM 1

Energy Smart Electric Water Heater Controller

CHAPTER 11: Flip Flops

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Installation and User Guide

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

LK Electric Boiler - 4,5

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Wireless Alarm system s manual

FG MOISTURE MONITOR Installation & Operation Manual

TC-9102 Series Surface Mount Temperature Controllers

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

How To Program An Autodialer

Installation Instructions

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

MAGNUM Original Sauna Stove 6.6 kw 9.0 kw 10.5 kw MAGNUM Cenik and Lite Sauna Stoves 6.6 kw 9.0 kw 10.5 kw Use and Installation

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

DMX2PWM 9 Channel Dimmer Setup Manual

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: Fax:

Power Socket (2 Gang)

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Mode Switch. Fan Switch Menu button Program button

Portable Air Conditioner

User and installation manual

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor


Electric mobility: The small charging in between Safe charging with the right charging cable for mode 2

Quick start: Energy Switch EU

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR


REMOTE CONTROL MANUAL

FIREDEX Conventional Fire Panels

Descriptive Technical Documentation. DTD no

Table of Contents Getting Started... 3 The Motors... 4 The Control Board... 5 Setting up the Computer with Mach Starting up the Equipment...

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

INFRARED QUARTZ WALL HEATER

ABB i-bus KNX SA/S Switch Actuators Product Manual

Transcription:

INDEPENDENT HOBS WITH HIC ELECTRONIC CONTROL ESSE-N / A.S. 1

What is HIC? HIC = Hob Independent Control New touch-control electronic for independent hobs, with new user interface philosophy Electronic modules with reduced width and height allow a new build-in philosophy, with higher flexibility in kitchen planning ESSE-N / A.S. 2

Mechanical construction Schematic Brand-specific aesthetics User Interface Variants 1 / 2 / 3 MACS-BUS Power board Electrics 1 circuit board for control and power supply to the elements = Power Board (PB) User Interface (UI) with touch control: single board (variants 1 and 2) double board (variant 3) ESSE-N / A.S. 3

HIC Touch Control Principle Touch Control is not capacitive, but works with Infrared Reflexion * Positioning of sensor relative to vitroceramic surface important for correct function ESSE-N / A.S. 4

Compact Horizontal 60 cm width, UI on R.H. front side ESSE-N / A.S. 5

Compact Horizontal 60 cm width, UI on R.H. front side ESSE-N / A.S. 6

Split Vertical 68 cm width, split lateral UI ESSE-N / A.S. 7

Split Vertical 68 cm width, split lateral UI ESSE-N / A.S. 8

Compact Horizontal* 60 cm width, UI on R.H. front side Frame Ceramic Glas & Print Worktop Protection Box Protection Box Powerboard Carrier Powerboard & Interface Box Right and left side wall of furniture 2 variants to place the intercaes in der hob with impact on Plastic Boxes and positioning of powerboard and wiring Level 2 Frame Carrier Mains Terminal Heaters Heaters Wiring Variante 1 (egal Touch 2) * split variant possible Heaters Heaters Sealing 2 Interface left Powerboard Interface right Interface Powerboard Interface & Powerboard Box ESSE-N / A.S. 9

Split Vertical 68 cm width, split lateral UI Pillar Clue Glas/Carrier Ceramic Glas & Print Pillar Worktop Left Side Box Screws - Frame Carrier Protection Box Rivets Boxes Carrier Right Side Box Worktop Right and left side wall of furniture Right and left side wall of furniture Interface Carrier Interface left Powerbo ard Mylar Folie Carrier Interface right Mains Terminal Interface Carrier Wiring Sealing 2 Mylar Folie Powerboard Heater Heaters Heater Heaters Sealing 1 Sealing 2 Interface Carrier Interface left Heaters Heater Heaters Heater Screws - Frame Carrier ESSE-N / A.S. 10

Compact Vertical 68 cm width, lateral UI on R.H. side Pillar Ceramic Glas & Print Clue Glas/Carrier Pillar Worktop Left Side Box Screws - Frame Carrier Protection Box Rivets Boxes Carrier Right Side Box Worktop Right and left side wall of furniture Right and left side wall of furniture Interface Carrier Powerboa rd Mylar Folie Carrier Interface right Mains Terminal Wiring Sealing 2 Mylar Folie Powerboard Heater Heater Sealing 1 Sealing 2 Heater Heater ESSE-N / A.S. 11

Build-in Philosophy of 68 cm Hob 68cm hob: HIC vertical, split or compact Hob tray Work plate furniture 75-90cm standard hob Disadvantage: cut-outs in furniture walls Hob tray Advantage: No cut-out required in furniture Lateral bays containing the circuit boards not thicker than work plate Adjacent furniture is fully usable, e.g. for building-in a dishwasher (!) ESSE-N / A.S. 12

User Philosophy Zone hot, booster not possible! Touch both fields to switch of zone H 0 3 A Decrease setting Increase setting Booster active ESSE-N / A.S. 13

ON/OFF 0 0 0 0 touch ON/OFF for about 2 sec automatic safety switch-off if: neither a cooking zone nor the timer are switched on within the next 10 sec permanent touch (e.g. object on touch fields) for more than 10 sec touch ON/OFF for about 2 sec for manual switch-off ESSE-N / A.S. 14

Stop & Go / Keep Warm U U U U all zones switch to keep-warm setting u when touching 2nd button (if configured as Keep Warm, or Stop&Go ) back to previous settings at next touch ESSE-N / A.S. 15

Function Lock (Key Symbol) 8 2 20. 3 5 neither cooking zone settings nor timer can be changed after touching 2nd button configured as Function lock (key symbol printed on panel) only main switch (ON/OFF) and function lock still active unlock by pressing key symbol again ESSE-N / A.S. 16

Booster A A A A activation depends on model definition: either with dedicated touch zone, or automatically if zone setting is selected with + only not possible if zone still hot (H shown) for duration see settings table ESSE-N / A.S. 17

0 0 Timer 20. 0 8 touch timer symbol repeatedly to select desired zone, set time with + or - acts as switch-off timer for cooking zone indicated by flashing dot, or as minute minder if activated without switching on any cooking zone ESSE-N / A.S. 18

Residual Heat Indicator H H H duration controlled by software with simple algorithm using preceding ON and OFF times Attention: residual heat indicator will not be re-activated after a power failure! ESSE-N / A.S. 19

Child Lock L L L L switch ON hob touch 2nd button (which, depending on model, is configured either as Lock, Keep Warm, or Stop&Go ) for 3 secs touch one of the + button L shows in display use same sequence with - button to de-activate to override once: touch + und - of one cooking zone simultaneously for 1 sec ESSE-N / A.S. 20

Demo and Service Mode J- S touch ON/OFF until display will go OFF again touch + and - for the front zones ( short beep) simultaneously for 3 sec ( short beep again) touch timer symbol d and S are shown in display either of the 2 modes can now be selected as shown on next slides ESSE-N / A.S. 21

Demo Mode J. - S touch + adjacent to d a dot will show in the display (d.) display goes OFF full user interface functionality can be simulated without switching on the heating elements use same input sequence to de-activate demo mode DISCONNECTING THE POWER SUPPLY WILL NOT DE-ACTIVATE THE DEMO MODE! ESSE-N / A.S. 22

Service Mode J- S touch + adjacent to S automatic test sequence will start relays switch on and off for 3 secs each all LEDs ON timer display shows software versions of the different boards no Alarm Codes!! hob switches off at the end of the test sequence ESSE-N / A.S. 23

Settings ESSE-N / A.S. 24

Flatpak Block Diagramm Intelligent Power Board EMC filter ~ 13 V Power switching 2 APD & 8 Relay max. 20kHz PWM Reset circuit Reset µc ST72314 44 pin QFP 8k ROM Board temp AD SCI 50Hz 5 V GND Zero crossing detection EMC filter SMPS UI Connector 3-pole Mask µc > 20K Flash for flexibility ESSE-N / A.S. 25

Power Board BR13 APD Relay 10 APD Relay 9 BR14 Relay 8 Relay 7 Relay 6 Relay 5 Relay 4 Relay 3 Relay 2 Relay 1 BR12 BR16 BR10 BR9 BR8 BR7 BR6 BR5 BR4 BR3 BR2 BR1 Heater 8 5.2A max. L1-17.4A max. Heater 7 10A max. Heater 6 10A max. Heater 5 5.2A max. Heater 4 5.2A max. L2 17.4A max. Heater 3 10A max. Heater 2 10A max. Heater 1 5.2A max. L2 L1 N HOC2000 Power Board ESSE-N / A.S. 26

Power Board not possible to detect wrong connection (400 V), because power supply circuits are destroyed very quickly hob is switched off if power board temperature exceeds 130 C ESSE-N / A.S. 27

Communication UI - PB User Interface Left User Interface Right User Interface Rast 2,5 L1 Neutral Heaters Heaters Heaters BR14 BR13 BR12 BR11 BR10 BR9 BR8 BR7 BR6 BR5 BR4 BR3 BR2 BR1 Neutral Phase L2 + 5V MACS BUS Mains supply Heaters earth Power Board (Flatpak) connector ESSE-N / A.S. 28

Variants Max. relay current ESSE-N / A.S. 29

Variants Max. relay current ESSE-N / A.S. 30

Variants Max. relay current ESSE-N / A.S. 31

Variants Max. relay current ESSE-N / A.S. 32

Variants Max. relay current ESSE-N / A.S. 33

Variants (Heater Codes) 1200 W RHL1 5.2 A 1800 W RHL2 7.8 A 2300 W RHL3 10.0 A 800 W RHLD3-s 3.5 A 800 W RHLD3-d 3.5 A 700 W RHLD3-t 3.0 A 700 W RHLZ2-s 3.0 A 1000 W RHLZ2-d 4.3 A 600 W RHLZ20-s 2.6 A 1100 W RHLZ20-d 4.8 A 750 W RHLZ3-s 3.3 A 1450 W RHLZ3-d 6.3 A 1000 W RHLZ31-s 4.3 A 1200 W RHLZ31-d 5.2 A 1500 W RHLZ7-s 6.5 A 700 W RHLZ7-d 3.0 A 600 W RH3RHL-hp 2.6 A 1900 W RH3RHL-lp 8.3 A ESSE-N / A.S. 34

Power Management duty cycles of cooking zones are interlaced as far as possible Heater 1 L 1 Heater 2 state state state or T state or T T T ESSE-N / A.S. 35

Faults Zones still active after switch off UI= User Interface PB= Power Board Reset possible by switching on and off Communication error (poss. EMC problem) UI inactive, zones on low sensitivity of touch fields permanent touch detected presumably faulty PB UI active, zones do not react to inputs: presumably faulty PB ESSE-N / A.S. 36

Faults Zones went off, UI still on UI= User Interface PB= Power Board Reset possible by switching on and off Communication alarm caused relays to switch-off elements Reset NOT possible by switching on / off EEPROM fault, change PB UI can t be switched off: presumably faulty PB possibly faulty UI, or wrong positioning* of UI * N.B.: if UI is replaced, always use complete unit with new plastic support. Bending of old support can cause wrong position ESSE-N / A.S. 37

Faults Zones and UI went off UI= User Interface PB= Power Board Hob active again after approx. 30 secs. PB or UI reset Touch zones covered safety switch-off (beep) Permanent touch detected although touch zones not covered safety switch-off (beep). Touch zones re-calibrated after switch-off. Hob doesn t react any more: presumably faulty PB possibly faulty UI or wrong positioning* of UI Hob active again after some time PB overheat ESSE-N / A.S. 38

Faults UI went off, zones still on UI= User Interface PB= Power Board Reset possible by switching on and off switch-off caused by timer, auto switch-off. or permanent touch; not transmitted due to communication error UI active, zones don t react: presumably faulty PB UI not active, zones still on low sensitivity of touch fields permanent touch detected presumably faulty PB possibly faulty UI ESSE-N / A.S. 39