PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features



Similar documents
RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

MicroMachined Silicon modular pressure sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

UNIK Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard. Expertise

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Pressure transmitter For general industrial applications Model A-10

SEMICONDUCTOR TECHNICAL DATA

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Electronic Pressure Switch EDS 3000

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

The Do s and Don ts of Pressure Transducers

DPI 260 SERIES: Digital Pressure Indicators

The PACE5000 Modular Pressure Controller/Indicator

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Electronic Pressure Monitoring New Products

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

9000 Series Accelerometers Specifications

Relative and absolute pressure switch type 529

Airflow Sensors Line Guide

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Electronic Pressure Switch EDS 300

Models SFP33 & SFP32 Pressure Transmitters

ATL Fuel Level Sender Probes

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

PRODUCT PROFILE FEATURES

How to measure absolute pressure using piezoresistive sensing elements

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394

Heavy Duty Pressure Sensors/ Transducers Line Guide

Givare NC-SRS 280 och 880

Conductive Level Switch FK 2 Technical Data:

PTU Series Transducer Digital Display Indicator User s Manual

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Measurement & Control. Features. Applications. High accuracy. Bore hole monitoring

Electronic Pressure Switches

Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES

Features. Picture. Specifications

Freescale Semiconductor. Integrated Silicon Pressure Sensor. On-Chip Signal Conditioned, Temperature Compensated and Calibrated MPX5500.

Contents. Document information

D. PARAMETER SPECIFICATION Measured Variable: Displacement

Sensors OXYGEN SENSORS PRESSURE SENSORS TEMPERATURE SENSORS ROTARY POTENTIOMETER SPEED SENSORS UEGO LAMBDA BOX STAND-ALONE PRT 02/03/06 P002P010 OPS04

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

How To Use A Flowmeter

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Digital inductive conductivity transmitter

Product Catalogue. AP Automatyka ISO ISO OHSAS ISO 9001.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

and Accelerometers

The accelerometer designed and realized so far is intended for an. aerospace application. Detailed testing and analysis needs to be

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Data Sheet PS1B Pressure Switch

Adjustment functions for both span and shift have been incorporated

Mounting instructions. Acceleration Transducer B12. B 26.B12.10 en

Typical Aluminum GFM Mass Flow Meter

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

How To Power A Schen

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Relative pressure transmitter type 520

DS 600. A contact free flux gate based current measurement sensor 600A rms

Freescale Semiconductor. Integrated Silicon Pressure Sensor. On-Chip Signal Conditioned, Temperature Compensated and Calibrated MPX4080D.

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Low Frequency Velocity Sensor

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

Turbine Flowmeters for Gas Applications

Micro Motion Model D and DL Coriolis Flow and Density Meters

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Series 6000 Torque measured metal bellow coupling

Series 510 Submersible Level Transmitters

3-Component Measuring System

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Subminiature Load Cell Model 8417

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Electronic Product Catalog

Integrated Silicon Pressure Sensor On-Chip Signal Conditioned, Temperature Compensated and Calibrated

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

1701/22 FieldMonitor Management Interface Module

PART 1 - INTRODUCTION...

Actuators and Sensors. Products

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Cable Plug acc. to DIN EN , Form A

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

QR12 (1.22 ) Diameter Optical Encoder

Transcription:

Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a standard production device. Accuracy to ±0.04% full scale (FS) best straight line (BSL) Pressure ranges from 1 psi to 10,000 psi (70 mbar to 700 bar) Gauge, absolute and differential formats available Stability ±0.1% per annum GE manufactures precision pressure sensors with a capability to meet critical applications in industrial and research environments. Test equipment Research and development Environmental test Monitoring critical pressures General industrial 4 x full scale over pressure PMP 4000 Series Druck Amplified Output Pressure Transducers PMP 4000 Series is a Druck product. Druck has joined other GE high-technology sensing businesses under a new name GE. g

PMP 4000 Series Concept At the heart of the 4000 Series is an advanced, high stability pressure measurement element micromachined from single crystal silicon within GE s own processing facility. The silicon element is mounted within a high integrity glass-to-metal seal and is fully isolated from the pressure media by a Hastelloy isolation diaphragm, electron beam welded to the glass-to-metal seal. Surface mount electronics condition the output from the silicon diaphragm, correct for thermally induced errors and configure the output to the required high level voltage. Advanced design features built into the electronic circuitry enable minimum sensor size with utmost reliability. The electronics incorporate power supply regulation, reverse polarity, over-voltage and short circuit protection, coupled with EMC protection components. Silicon wafers being loaded into an oxidation furnace. The fully encapsulated solid state design ensures integrity of product under high levels of shock and vibration, with an ingress protection rating up to IP68, dependent upon the electrical termination selected. Every sensor is fully tested over both pressure and temperature ranges to demonstrate compliance to the specification. Prior to despatch, the sensor is adjusted to meet the particular pressure range and units, configured to the desired high level output voltage and completed with a range of electrical connections. The demountable electrical connection formats allow the user to access the zero and span trim controls for system interchangeability and ease of re-calibration. A range of stainless steel pressure connections interface the sensor to the process media. Computerised testing and calibration of pressure transducers. The PMP 4000 Series from GE is ideally suited to meet the demands of the industrial and automotive test cell market. Improved levels of performance measurement (± 0.04%), coupled with excellent stability, reduces the need for regular re-calibration periods, thus significantly reducing the cost of ownership. With the benefit of the latest silicon measurement technology, the PMP 4000 Series can withstand the most demanding applications and still provide the performance of a precision pressure measurement device. Automotive engine shown on a research and development test bed

PMP 4000 Series Specifications Pressure Measurement Operating Pressure Range Any zero based range from 1 to 940 psi (70 mbar to 65 bar) gauge 950 to 10,000 psi (65.1 to 700 bar) sealed gauge 5 to 10,000 psi (350 mbar to 700 bar) absolute 1 to 500 psi (70 mbar to 35 bar) differential Compound ranges, e.g. -15 to 30 psi (-1 to 2 bar) gauge, bi-directional differential ranges and other pressure units can be specified. Static/Line Pressure (PMP 4100) 1000 psi (70 bar) maximum Over Pressure The rated pressure can be exceeded by the following multiples causing negligible calibration change: Gauge and absolute reference: 10 x for ranges 1 to 5 psi (70 to 350 mbar) 6 x for ranges 5 to 10 psi (350 to 700 mbar) 4 x for ranges 10 to 940 psi (700 mbar to 65 bar), 2000 psi (140 bar) maximum 2 x for ranges 950 to 10,000 psi (65.1 to 700 bar), 20,000 psi (1380 bar) maximum Differential reference: Positive side: 10 x for ranges 1 to 5 psi (70 to 350 mbar) 6 x for ranges 5 to 10 psi (350 to 700 mbar) 4 x for ranges 10 to 500 psi (700 mbar to 35 bar) (1500 psi (100 bar) maximum) Negative side: Must not exceed positive side by greater than 6 x for ranges 1 to 5 psi (70 to 350 mbar) 4 x for ranges 5 to 10 psi (350 to 700 mbar) 2 x for ranges 10 to 75 psi (700 mbar to 5 bar) 150 psi (10 bar) for ranges 100 to 500 psi (7 to 35 bar) Containment The rated pressure can be exceeded by the following multiples while containing the pressure media: Gauge reference: 12 x for ranges 1 to 2.5 psi (70 to 175 mbar) 6 x for ranges 2.5 to 950 psi (175 mbar to 65 bar), 3000 psi (200 bar) maximum Absolute and Sealed Gauge reference: 3,000 psi (200 bar) for ranges up to 940 psi (65 bar) 20,000 psi (1380 bar) for ranges 950 psi (65.1 bar) and above Differential reference: Positive port: 12 x for ranges up to 5 psi (350 mbar) 8 x for ranges up to 10 psi (700 mbar) 6 x for ranges up to 500 psi (35 bar), 3000 psi (200 bar) maximum Negative port: 8 x for ranges up to 5 psi (350 mbar) 6 x for ranges up to 10 psi (700 mbar) 4 x for ranges up to 500 psi (35 bar), 200 psi (15 bar) maximum Excitation Voltage 9 to 32 VDC 15 to 32 VDC for all ranges and spans below 10 psi (700 mbar) 15 to 32 VDC for 10 VDC output Output Voltage 1 psi (70 mbar) 0 to 2 VDC (maximum) 2 psi (175 mbar) 0 to 4 VDC (maximum) 5 psi (350 mbar) and above Standard Output 0 to 5 VDC Alternate Output, e.g. 1 to 5 VDC 0 to 10 VDC, 5 to +5 VDC can be specified Compound and bi-directional outputs are available 4 wire outputs are available Note: maximum offset at zero pressure cannot exceed +2.5 VDC. For non standard output, please check with your local sales office before ordering. Output Impedance <20 Ω Load Impedance Greater than 10 k Ω for quoted performance R-Cal Facility/Shunt Calibration (Option C) Connecting an external link between the appropriate terminals results in a positive shift of 80% FSO. Other values are available refer to GE.

Performance Accuracy Combined Non-linearity, Hysteresis and Repeatability Standard: ±0.08% FS BSL Option A: ±0.04% FS BSL ranges above 2.5psi (175 mbar) except ±0.06% FS BSL for 75 psi range (5 bar) Zero and Span adjustment ±5% site adjustable by sealed, noninteracting potentiometers. (Demountable electrical connections only.) Temperature Effects Standard: ±1% FS TEB over 32 to 122 F (0 to 50 C) ±2% FS TEB over -4 to 176 F (-20 to 80 C) Option B: ±0.5% FS TEB over 32 to 122 F (0 to 50 C) ±1% FS TEB over -4 to 176 F (-20 to 80 C) For ranges below 5 psi (350 mbar) these values increase pro rata. Acceleration Sensitivity Typically 0.02% FS/g for 5 psi (350 mbar) decreasing to 0.0003% FS/g for ranges above 900 psi (60 bar), along the sensitive axis. Mechanical Shock 1000g, 1ms half sine pulse in each of 3 mutually perpendicular axes will not affect performance. Vibration Response less than 0.05% FS/g at 30g peak 10Hz-2kHz, limited by 0.47 in (12 mm) double amplitude. (MIL-STD 810C Proc 514.2-2Curve L) Physical Operating Temperature Range -4 to 176 F (-20 to 80 C). Positive Pressure Media Fluids compatible with stainless steel 316L and Hastelloy C276 Negative pressure media (PMP 4100) Fluids compatible with stainless steel 316L, silicon, pyrex and adhesive Weight 0.24 lb (120 g) nominal, 1 to 940 psi (70 mbar to 65 bar) ranges 0.37 lb (170 g) nominal, 950 to 10,000 psi (65.1 to 700 bar) ranges 0.42 lb (200 g) nominal for differential ranges CE marking CE marked for electromagnetic compatibility and the pressure equipment directive Pressure Connection 1/4 NPT female as standard Other pressure connections available For pressure ranges above 950 psi (65.1 bar) alternative pressure connections are via adaptors (refer to GE for details). Electrical Connection A range of cable and connector versions are available. Some electrical options are demountable to allow access to zero and span potentiometers. See installation drawings and ordering information for details. Calibration Standards Instruments manufactured by GE are calibrated against precision pressure calibration equipment which is traceable to National Standards. Options (A) Improved accuracy ±0.04% FS BSL, ±0.06% FS BSL for 75 psi (5 bar) ranges (B) Improved temperature effects (C) R Cal/shunt facility (D) Mating connectors for PMP4X6X variants

Gauge and absolute core 2.7 in (69 mm) up to 940 psi (65 bar) 3.8 in (96 mm) 950 psi (65.1 bar) and above Differential core 22 A/F 1 in (25 mm) High Low 1 in (25 mm) 22 A/F 2.5 in (65 mm) Ordering Information Please state the following: 1) Select model number Code Base model number PMP4 Base model Code Pressure Reference 0 Gauge, Absolute or Sealed Gauge 1 Differential Code Electrical Connector 10 Fixed cable 15 Demountable cable 30 Fixed submersible cable 60 Fixed 6 pin bayonet 65 Demountable 6 pin bayonet 70 Demountable DIN plug/socket Code Options O None A Improved accuracy B Improved temperature effects C Rcal/shunt facility D Mating bayonet connector (for 4X6X) 2.3 in (58 mm) 2.4 in (61 mm) Cable 0.17-0.27 in (4.5-7 mm) 2) State pressure range and units 3) State pressure reference (Gauge, Absolute, Sealed Gauge) 4) Output voltage at lowest pressure (check output voltage rules) 5) Output voltage at highest pressure (check output voltage rules) 6) Non standard pressure connection (refer to GE ) Din plug Cable 1.29 in (33 mm) 0.2 in (6 mm) PMP4X70 (Demountable) 1.97 in (50 mm) 0.2 in (6 mm) Wiring detail US Build Part No. supply supply output output RCAL*1 RCAL*1 Case +ve -ve +ve -ve PMP4X10 red white yellow blue orange black n/a PMP4X15 red white yellow blue orange black shield PMP4X30 red white yellow blue orange black shield PMP4X60 A B C D E F n/a PMP4X65 A B C n/a E F D PMP4X70 1 2 3 n/a n/a n/a earth (Fixed) PMP4X10 (Demountable) PMP4X15 2.8 in (70 mm) 1.02 in (26 mm) PMP4X30 1.42 in (36 mm) 0.3 in (8 mm) Bayonet connector (Fixed) PMP4X60 (Demountable) PMP4X65

g 2007 GE. All rights reserved. 920-241B All specifications are subject to change for product improvement without notice. GE is a registered trademark of General Electric Co. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE. www.gesensing.com