1 GE Measurement & Control RPS/DPS 8100 High Accuracy Resonant Pressure Sensor For over 40 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial, aerospace, oil and gas, and research environments. Today, Druck is part of GE Measurement & Control and has continually worked to develop and improve on the performance of our pressure sensors to meet customer s requirements. The RPS/DPS 8100 incorporates the exciting new TERPS technology. TERPS is a resonant silicon pressure sensor technology platform that provides an order of magnitude greater accuracy and stability than current pressure measurement technologies. In addition to providing the performance and packaging improvements available with TERPS, the RPS/DPS 8100 product line takes advantage of best practices to offer a wide range of pressure and electrical connections to enable a level of customization for your specific requirements never before available in the performance class of this sensor. The combination of the power of the TERPS technology and the quality, reliability and flexibility of the RPS 8100 Series offer a truly unique solution for high accuracy and high stability pressure measurement requirements. Features: High Precision, ±0.01% FS over compensated temperature range High Stability, ±100 ppm FS/year Wide temperature range, -40 to +85 C (-40 to 185 F) Multiple Output configurations, RS-232, RS-485, Frequency & Diode (TTL) Wide selection of pressure & electrical connections to suit specific requirements Low acceleration effects
2 Specifications Measurement Base Pressure Ranges 0 to 2 bar (0 to 30 psi) absolute 0 to 3.5 bar (0 to 50 psi) absolute Calibrated Ranges 35 to 3500 mbar (0.5 to 50 psi) absolute 35 to 2000 mbar (0.5 to 30 psi) absolute 750 to1150 mbar (11 to 17 psi) barometric Any zero-based range between 1 and 3.5 bar (14.5 to 50 psi) can be specified. (Values in psi are approximate.) Alternative barometric ranges are available on request. Higher pressure ranges are available in the RPS/DPS 8000 series. Overpressure 2X FS Pressure Containment 7 bar, (100 psi) Supply and Output Electronics Option Supply Voltage (V) Output 0 6 to 28 Frequency^ & Diode^^ (Low Power)* 1 6 to 28 Frequency^ & Diode^^ (Low Noise)** Current Consumption*** (ma) A 11 to 28 RS quiescent, 32 max B 11 to 28 RS quiescent, 32 max * Low Power has Jitter of <120 ns ** Low Noise has Jitter of <75 ns *** At 25 C (77 F) ^ Square wave pressure signal, 25 khz nominal, 4-10 khz span ^^ Forward voltage diode, 0.4 to C (77 F), typically 2 mv/ C nominal Response Time Frequency Output <25 ms for pressure change from 10% to 90% FS RS232/485 Output Dependent on the output update rate which is set by the user with a minimum of 100 ms (see manual K0473 for details) supply switch on Electrical Protection Connecting V supply and GND between any combinations of pins on the connector will not damage the unit Insulation 500 V dc Performance There are two levels of performance specification: Standard and Improved Specifications include combined effects of non-linearity, hysteresis, repeatability and temperature errors over the compensated temperature range and calibrated pressure range. Accuracy Code Precision A1- Standard 0.02% FS A2- Improved 0.01% FS For Frequency & Diode output the above accuracies are achievable by using a polynomial curve fit algorithm and coefficient data supplied with the sensor. Sensors are calibrated against standards traceable to UKAS operating to better than 100 ppm. Compensated Temperature Ranges: There are two compensated temperature ranges available: -10 to +50 C -40 to +85 C Temperature Effects All temperature effects are included in the accuracy statement. Long Term Stability Standard: ±0.02% FS/annum Improved: ±0.01% FS/annum Note: Unless otherwise stated, specifications are at reference conditions: 25 C (77 F) ±5 C (±9 F). Orientation (g) Sensitivity Less than 0.05 mbar/g Supply Response Frequency & Diode: Accurate to specification within 500 ms of supply switch on, over all operating temperatures RS 232/485: Accurate to specification within 20 s of
3 Physical Specifications Storage Temperature Range As compensated temperature range. Operating Temperature Range -40 to +85 C (-40 to +185 F) Restricted by some electrical connector options. Please ensure that only the intended sealing face is used when mounting the sensor. Failure to comply with this requirement may affect performance or calibration accuracy. Male threaded pressure connectors must not be sealed or constrained against the face at the base of the thread. The forward cone or flat face should always be used, as indicated below. Pressure Media Non-condensing dry gases compatible with 316L Stainless Steel, silicon, silicon dioxide, RTV adhesive and glass Ingress Protection See Electrical Connector Section Vibration DO-160E Curve W Sine sweeps 5 Hz to 2 khz, levels to 20g n <0.2 mbar/g n (<0.003 psi/g n ) output change Shock DO-160E 9 (Figure 7.2) 20 g n 11 ms terminal saw-tooth profile Negligible calibration change Humidity MIL-STD-810D Method Procedure III (Aggravated humidity environment, 65 C, 95% RH). It is recommended that in all non-dry environment applications, that sealed electrical connectors are selected (options 3, 4, 6 or G) Pressure Connector Available Options are G1/4 Female G1/4 Male Flat G1/4 Male 60 degree Cone G1/8 Male 60 degree Cone 1/4 NPT Female 1/4 NPT Male 1/8 NPT Male M20 x 1.5 M14 x degree Internal Cone M12 x 1 Internal Cone 7/16 UNF Male G1/2 Male G1/4 Quick Connect 1/2 NPT Male G1/4 Male Flat Long 7/16-20 UNF Female Depth Cone (G1/4 Female) 7/16-20 UNF Male Short Flat Other pressure connectors may be available. Contact GE to discuss your requirement. Electrical Connector Code Number Description Max Operating temp range C F 0 No Connector -55 to to Polyurethane Cable -40 to to Raychem Cable -55 to to Polyurethane Depth -40 to to Hytrel Depth -40 to to MIL-C to to +257 * C 1/2 NPT Conduit -40 to to G M12 X 1 5-pin -55 to to +267 * H PTFE Cable (Orange) -55 to to IP rating Note: Hermetically sealed connectors with a maximum leak rate of 1 x 10-6 cc/s at 1 Atmosphere. High IP rated mating connectors are available.
4 Connection Details Option Code Connection Function Flying Leads CABLE 1, 3, 4, C Frequency & Diode Digital- RS485 0 RED SUPPLY SUPPLY YELLOW FREQ RS485 B Rx GREEN TEMP RS485 A Tx Digital - RS232 SUPPLY BLUE GROUND GROUND GROUND BLACK -VE TEMP - - ORANGE EEPROM - - RED SUPPLY SUPPLY YELLOW FREQ RS485 B Rx BLUE TEMP RS485 A Tx SUPPLY WHITE GROUND GROUND GROUND BLACK -VE TEMP - - ORANGE EEPROM - - SCREEN RAYCHEM 2 RED SUPPLY SUPPLY WHITE FREQ RS485 B Rx GREEN TEMP RS485 A Tx SUPPLY BLUE GROUND GROUND GROUND BLACK EEPROM - - SCREEN MIL-C 6 A SUPPLY SUPPLY B FREQ RS485 B Rx C TEMP RS485 A Tx SUPPLY D GROUND GROUND GROUND E EEPROM - - F -VE TEMP - - M12 G 1 SUPPLY SUPPLY 2 FREQ RS485 B Rx SUPPLY 3 GROUND GROUND GROUND 4 TEMP RS485 A Tx 5 EEPROM - - PTFE H RED SUPPLY SUPPLY YELLOW FREQ RS485 B Rx GREEN TEMP RS485 A Tx SUPPLY BLUE GROUND GROUND GROUND BLACK EEPROM - - WHITE -VE TEMP - - SCREEN Certification CE Marked RoHS EMC Standards BS EN : 2007 Susceptibility - Light Industrial BS EN : 2005 Susceptibility - Heavy Industrial (except mv versions) BS EN : 2007 Emissions - Light Industrial BS EN : 2007 Emissions - Heavy Industrial BS EN : 2006 Electrical Equipment for Measurement, Control and Laboratory Use - EMC requirements BS EN :2006 Requirements for pressure transducers
5 Mechanical Drawings 8 (0.31) 78 (3.07) DRUCK LTD. GR #### 81## S/N ******* *** TO *** ba Supply: *** T Output: *** T Temp. Range: RPS800 PRESSU MALE PRESSURE CONNECTION MEDIUM PRESSURE CONSTRUCTION POLYURETHANE CABLE IP65 ( 22 A/F) (0.86) 7 (0.27) 21 TYP (0.82) 22 A/F (0.86) RAYCHEM CABLE 14.5 (0.57) 42 (1.65) 32 (1.25) 60 (2.36) Ø25 FEMALE PRESSURE CONNECTION 1/2 NPT CONDUIT WITH POLYURETHANE CABLE POLYURETHANE CABLE (DEPTH) HYTREL CABLE (DEPTH) ( 22 A/F) 16 (0.62) 15.5 (0.61) 7 (0.27) 15 TYP (0.53) DEPTH CONE PRESSURE ADAPTOR M12x1 5-PIN PTFE CABLE (ORANGE) 25 TYP 17 (0.66) OPTIONAL WELDED PRESSURE ADAPTOR Ø25 OTHER PRESSURE CONNECTOR DETAILS AVAILABLE ON REQUEST NO ELECTRICAL CONNECTOR (FLYING LEADS) MIL-C (6 PIN SHELL SIZE 10) Notes: 1. All dimensions are nominal lengths and are subject to change. 2. All dimensions are in millimeters (inches). 3. Other pressure and electrical connectors may be available, please contact GE.
6 (1) Select model number Main Product Variant RPS Resonant Pressure Sensor - Frequency & Diode Output (Note 1) DPS Digital Pressure Sensor - Digital Output (Note 1) Product Series 8 RPS/DPS 8000 Series Diameter, Material and Isolation 1 25mm Stainless Steel Silicon Exposed Electrical Connector 0 No Electrical Connector (Flying leads) 1 Polyurethane Cable 2 Raychem Cable 3 Polyurethane Cable (Depth) 4 Hytrel Cable (Depth) 6 MIL-C (6-pin Shell Size 10) C 1/2 NPT Conduit with Polyurethane Cable G M12x1 5-Pin H PTFE Cable (Orange) Output Option 0 Frequency & Diode (Low Power <3.5 ma) 1 Frequency & Diode (Low Jitter aprox 75 ns) A RS485 B RS232 Compensated Temperature Range TA -10 to +50 C TB -40 to +85 C Accuracy A1 - Standard 0.02% A2 - Improved 0.01% Calibration CC Full Thermal Calibration Hazardous Area Approval H0 None Pressure Connector PA G1/4 Female PB G1/4 Male Flat PC G1/4 Male 60 degree internal Cone PD G1/8 Male 60 degree internal Cone PE 1/4 NPT Female PF 1/4 NPT Male PG 1/8 NPT Male PH M20x1.5 PJ M14x Internal Cone PK M12x1 Internal Cone PL 7/16-20 UNJF Male 74 degree external cone PN G1/2 Male PQ G1/4 Quick Connect PR 1/2 NPT Male PT G1/4 Male Flat Long PV 7/16-20 UNF Female) PW Depth Cone (G1/4 Female) PX 7/16-20 UNF Male Flat R TA - A2 - CC - H0 - PA Typical Model Number Note 1: RPS variants require Output Option Code 0 or 1. DPS variants require Output Option Code A or B..
7 2) State pressure range and units: e.g. 0 to 20 bar, 0 to 100 psi Unit options are: Symbol bar mbar psi Pa hpa kpa MPa mmh 2 O cmh 2 O mh 2 O inh 2 O fth 2 O mmhg inhg kgf/cm 2 atm Torr Description bar millibar pounds/sq. inch Pascal hectopascal kilopascal megapascal mm water cm water metres water inches water feet water mm mercury inches mercury kg force/sq. cm atmosphere torr 3) State cable lengths and units: e.g. 1 m cable, 8 ft cable (only required on certain electrical connectors) Typical order examples: RPS 8110-TA-A1-CC-H0-PA, 3.5 bara, 5 m cable DPS 816A-TB-A2-CC-H0-PL, 750-1,150 mbara
8 B 2013 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.
RPS 8000. High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:
GE Measurement & Control Solutions RPS 8000 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in
UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.
GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform
UNIK 5000. Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard. Expertise
GE Measurement & Control UNIK 5000 Pressure Sensing Platform The new UNIK 5000 is a high performance configurable solution to pressure measurement. The use of Druck silicon technology and analogue circuitry
PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features
Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a
RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features
GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high
Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020
Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and vibration resistant
Druck DPI 142/150. GE Infrastructure Sensing. Pressure Indicator Calibration manual - K382
GE Infrastructure Sensing 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Druck DPI 142/150 Pressure Indicator Calibration manual - K382 Introduction This technical manual
PACE1001 Barometer Precision Barometric Indicator and Recorder
GE Measurement & Control PACE1001 Barometer Precision Barometric Indicator and Recorder A high precision Druck indicator and recorder, designed for barometric monitoring in laboratories, airfields and
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394
GE Industrial Sensing 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Druck DPI 104 Digital pressure indicator User manual - K394 A1.1 A1.2 B1 1 A2 B2 2 3 4 5 6 A1.3 8 7
Temperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
PACE1000 Precision Pressure Indicator
GE Measurement & Control PACE1000 Precision Pressure Indicator A high precision Druck pressure indicator, designed for test bench, bench top and panel mount calibration, test and monitoring applications.
The PACE5000 Modular Pressure Controller/Indicator
GE Sensing The PACE5000 Modular Pressure Controller/Indicator First in a new generation of modular, high precision Druck pressure controllers/indicators, designed for ATE and test bench applications. The
Relative and absolute pressure switch type 529
Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20
PACE Modular Pressure Controller
GE Measurement & Control Solutions PACE Modular Pressure Controller A new generation of high precision Druck pressure controller, designed for test bench, bench top & rack mount calibration & automated
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
MicroMachined Silicon modular pressure sensor
MicroMachined Silicon modular pressure sensor Configurable High Accuracy High Temperature Performance For Industrial, Test and Measurement, and Aerospace Applications Low Pressure from 10 in-h 2 O to 2.5
Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
9000 Series Accelerometers Specifications
Technical Data 9000 Series Accelerometers Specifications Catalog Numbers EK-43781I, EK-43782I, EK-46255I, EK-45890I, EK-43784I, EK-47086I, EK-43792I, EK-47090I, EK-43799I, EK-43794I, EK-43795I, EK-43797I,
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
www.suco.de Electronic Pressure Monitoring New Products
Electronic Pressure Monitoring New Products RoHS compliant Electronic Pressure Switches SoS-Technology with one or two switching functions Electronic Pressure Switches CE marking SUCO Electronic pressure
DPI 260 SERIES: Digital Pressure Indicators
DPI 260 SERIES: Digital Pressure Indicators INTRODUCTION The DPI 260, 261 and 262 range of digital pressure instruments measure and indicate pressure in any specified scale units and provide accuracies
Description. Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers
Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers R Description These accelerometers are intended for critical machinery applications where casing acceleration
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring Description The standard 330400 Accelerometer has a limited temperature range it can be exposed to, due to its signal
330505 Low Frequency Velocity Sensor
330505 Low Frequency Velocity Sensor Bently Nevada* Asset Condition Monitoring Description The Bently Nevada Low Frequency Velocity Sensor is designed to measure absolute (relative to free space) bearing
200350 and 200355 Accelerometers
and Accelerometers Bently Nevada Asset Condition Monitoring Description The and Accelerometers are general purpose, casemounted seismic transducers designed for use with Trendmaster Pro Constant Current
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured
OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Relative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
OEM-EP Pressure Controllers
Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
QR12 (1.22 ) Diameter Optical Encoder
Improving the Quality of Life through the Power in Light QPhase QR12 (1.22 ) Diameter Optical Encoder Design Features: Low profile assembled height of Bearing design simplifies encoder attachment Resolutions
Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
Velomitor Piezo-velocity Sensor
Specifications and Ordering Information Velomitor Piezo-velocity Sensor BENTLY NEVADA MADE IN U.S.A. VELOMITO PN 330500 100 mv/in/s (4 mv/mm/s) Description Velomitor Piezo-velocity Sensors measure absolute
Typical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
Digital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
Givare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Features. Picture. Specifications
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
Precision Pressure Indicator Model CPG2500
Calibration Technology Precision Pressure Indicator Model CPG2500 Data Sheet CPG2500 11/2014 Applications Pressure standard for calibration labs Transfer standard with remote transducers Pressure instrument
Druck DPI 104-IS Intrinsically safe digital pressure indicator
GE Measurement & Control Solutions Druck DPI 104-IS Intrinsically safe digital pressure indicator User manual - K0436 L1 II 1 G Ex ia IIC T4 Ga (-10 C Ta +50 C) ( 1) L2 Druck, LE6 0FH, UK ITS07ATEX25517X
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Conductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer
PT-400 Heavy Duty, Amplified Output Pressure Transducer C US The PT-400 offers high accuracy and reliability over a wide range of pressures. The small size, integrated electronics, wide operating temperature
Description. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T
Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock
RoHS. Shock / vibration resistant. Magnetic field proof. Many variants
Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.
Sensors OXYGEN SENSORS PRESSURE SENSORS TEMPERATURE SENSORS ROTARY POTENTIOMETER SPEED SENSORS UEGO LAMBDA BOX STAND-ALONE PRT 02/03/06 P002P010 OPS04
OXYGEN SENSORS UEGO LAMBDA BOX STAND-ALONE PRESSURE SENSORS PRT 02/03/06 P002P010 OPS04 TEMPERATURE SENSORS Sensors ATS 04 NTC PT1000 TC-K WTS 05 ROTARY POTENTIOMETER RPT98 W1051 W1059 SPEED SENSORS SEN
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
Mass Flow Meters & Controllers
HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2% of Full Scale) 0-5 VDC or 4-20
Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
How To Power A Schen
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
Heavy Duty Pressure Sensors/ Transducers Line Guide
Sensors/ Line Guide products. Built for the toughest applications. Honeywell Sensing and Productivity Solutions (S&PS) offers decades of experience in the heavy duty pressure products industry. That s
Datalogger DL/N 70 Version: 28.03.2012
Datalogger DL/N 70 Version: 28.03.2012 Technical Specifications Pressure measuring range (mh20) 1... 5 > 5... 20 > 20... 250 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure > 200 bar > 200 bar
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000
Electrical Specification for: CPCI-3U-AC-300W-R Rugged 300W AC Input 3U CompactPCI Power Supply Telkoor Part Number: 900-4602-0000 GENERAL SCALE RELEASE DATE 12/9/06 SHEET 1 OF 6 REVISION HISTORY Rev Level
FEATURES. ! Sealing to IP68 (fully waterproof) Infra-red optical navigation technology
ERGONOMICAL IP68 TRACKBALL UNIT Waterproof trackball & scroll wheel IP68 50mm The Series desktop trackball is an extremely high specification device that incorporates the latest IP68 technology. The trackball
Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Measurement & Control. Features. Applications. High accuracy. Bore hole monitoring
GE Measurement & Control Depth/Level Druck Submersible Pressure Sensors Product Guide Features High accuracy Excellent reliability Robust construction Harsh media compatible High stability Low power/pulsed
Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES
Precision Gage/Absolute Transducer DESCRIPTION Model TJE pressure transducers are all-welded stainless steel sensors built for rugged industrial applications that require high accuracy and measurement
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]
Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]
Data Sheet PS1B Pressure Switch
Data Sheet PS1B Pressure Switch Main Features Pressure Ranges 0 to 6 up to 0 to 600 bar (gage) Electrical Connection G 1/4 A DIN 3852-E or -A Pressure Connection Output Signal M12-4 Pin 4-20 ma, Programmable
1/2 NPTM. 29.21 mm 1.15. Nose cone fitting Ideal for clean liquids
PT-500 Submersible Liquid Level Transmitter 1.0 Hex 25.4 mm 7.0 177.8 mm Re-Usable cage fitting Ideal for dirty liquids 5.63 143 mm 5.33 136 mm 1/2 NPTM 3.5 88.9 mm 1.15 29.21 mm Nose cone fitting Ideal
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
Technical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370
Pump_TM016 Pump Local Display TM0200 TM0200 4-20mA PLC/DCS Case 1 Pump Relay Output Module 4-20mA Optional PT371 Modbus PT373 Case 2 PCM370 TM016 Velocity/ Acceleration Vibration Transmitter Introduction
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Turbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
Laminar Flow Elements
Laminar Flow Elements Meriam Laminar Flow Elements (LFEs) are excellent for measuring low gas flow rates from 0.2 SCCM up to 2250 SCFM. They are inherently accurate and repeatable and are calibrated traceable
PTU Series Transducer Digital Display Indicator User s Manual
PTU Series Transducer Digital Display Indicator User s Manual The Swagelok PTU series digital display indicator is available to mount directly to the Swagelok PTU series transducer to provide local indication
DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators
Features Ranges 2.5 mbar to 700 bar Accuracy from 0.025% full scale (FS) Integral combined pressure/vacuum pump Dual readout: input and output 4 to 20 ma loop test: auto step and ramp Intrinsically safe
ABSOLUTE ROTARY ENCODER ETHERNET/IP
Main Features - Compact and heavy duty industrial model - Interface: EtherNet/IP - Conformance tested by ODVA - Housing: 58 mm - Full shaft: 6 or 10 mm / hollow shaft15 mm - Resolution: max. 30 Bit = 1,073,741,824
O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications
Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection
Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol
Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]
Specification of 5 Wire Analog Touch Panel
Specification of 5 Wire Analog Touch Panel 5 WIRE ANALOG RESISTIVE TOUCH PANEL A. Application This specification applies to the 5 Wire Analog Resistive Touch Panel. B. Environmental Conditions 1. Operating
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
iva Cable & Antenna Analyzer
iva Cable & Antenna Analyzer VSWR, Return Loss Measurement & Distance to Fault The iva Series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure VSWR/return
Product Catalogue. AP Automatyka +48 67 357 10 80 [email protected] www.apautomatyka.pl ISO 16949 ISO 14001 OHSAS 18001 ISO 9001.
Product Catalogue ISO 16949 ISO 14001 OHSAS 18001 ISO 9001 Marine Division Since 1945 your qualified partner 1945 Huba Control AG founded 1974 Taken over by Stäfa Control System AG 1990 Concentration
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency
for low-frequency measurements FEATURES» From the Vibro-Meter product line» Low-frequency compensation allows frequency response down to 0.5 Hz ( 3 db)» Voltage or current modulated output signal» No need
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
DS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
Precision digital pressure gauge Model CPG1500
Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration
P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features
P3000 Series Pneumatic Deadweight Testers P3000 Technical Data Features Pressure ranges from Vacuum through 2 000 psi (140 bar) Accuracy better than 0.015 % of reading. (Increased accuracy option of 0.008