Electronic Pressure Switches

Size: px
Start display at page:

Download "Electronic Pressure Switches"

Transcription

1 Electronic Pressure Switches Electronic Pressure Switches c Pressure - Electronic Pressure Switches - Mechanical Pressure Switches - Pressure Transducer c Valves & Regulators c Temperature c Level c Flow c Air Suspension Valves

2 Table of Contents Electronic Pressure Switches SW Electronic Pressure Switch UDS7 Series - Electronic Pressure Switch 5 UDS7-BX - Explosion Proof Electronic Pressure Switch 7 UDS Series - UDS7-BX 9 UAS Series - Electronic Trip Amplifier

3 Solid State Electronic Pressure Switch SW2000 Features Pressure control with internal stainless steel diaphragm High accuracy with fully adjustable deadband 2 solid state contacts or solid state contact plus -20 ma analog output Built-in digital display readout Fully configurable via keypad Suitable for rapid cycling (00 times per second) UL/CSA approved Electrical connector not included Applications OEM-applications in hydraulics and pneumatics Lubrication monitoring Machine tool industry Injection molding machines Compressor Apparatus engineering equipment Shown with /-8 NPT connection General Specifications* Accuracy: Linearity Error: 0.5% FS Repeatability: ±0.% f. s. Sensor Element: Material: Wetted Parts: Seals: Measuring Ranges (psi): Proof Pressure (psi): Process Connection: Electrical Connection: Power Supply: Power Consumption: A/D-Converter: Resolution: Time Constant: Analog Output: Current Output: Load: Load Influence: Voltage Output: Rating: Adjustment Range Switching Output(s): Switching Function (adjustable): * See product configurator for additional options. ±0.5% f. s. at 77 F(25 C) Piezoresistive silicone measuring sensor 0 stainless steel Viton (FKM fluorelastomer) ,600 /-8 NPT, 7/6-20 SAE, G/ M Plug M 2 x, -pin 5 to 28 VDC reverse polarity protected approx. 50 ma (without load) 0 bit (,02 steps per measure. span) 00/s (for peak value memory) approx. 0s -20 ma max. Rl = (Ub-2 V) / 20 ma Rl = 600 ohm at 2 VDC 0.% / 00 ohm 5 ms 0 to 0 VDC (optional) max. 0 ma, short circuit-protection 25% to 00% f. s. Normally open / normally closed, standard-/window-mode Switching Output(s) Cont.: Adjustment Range: Hysteresis: Switching Frequency: Contact Rating: Status Display(s): Digital Display: Display Range: Display Rate: Error Display: Operating Elements: Temperature Range: Media: Electronics: Storage: 0% to 25% f. s. 0% to 25% f. s. max. 00 Hz max. 500 ma, short circuit-protection 0.0 to 9.9 s adjustable Green LED(s) -digit 7-segment LED display, height 0 mm, (0.9 inches), red - to /s Orange LED display (AL). easy response push buttons Temperature Influence: ±0.2% f.s. /0K Compensation Range: Protection Class: Dimensions (Housing): Additional Features: - F to 22 F (-25 C to +00 C) F to 58 F (-0 C to +70 C) -22 F to 76 F (-0 C to +80 C) F to 58 F (-0 C to +70 C) IP65-7/6 X 5-/8 (6 mm x 0 mm) (without electrical plug) 7-segment LED display, microprocessor, self monitoring with error display, all parameters are configured by keypad. Tamper proof, keypad lock, rugged construction, vibration- and shockproof, long term stability, controlled Weight: approx. 0. lb (200 g) Approvals: c/ulus: file No. E286

4 Electronic Pressure Switch SW2000 Technical Drawings -7/6 (Ø 6) +Ub + Ub Switch SP SWITCH SP *SP2+Diagnosis output SP2 * OV - 20 ma OV S AI S2 Plug -pin Plug M 2 X pin 2 Model with switching output Model with 2 switching outputs Model with switching output and analog output 2 Pin brown Pin 2 white Pin blue Pin black +Ub (5-28 V DC) +Ub (5-28 V DC) +Ub (5-28 V DC) - SP2 (0.5 A max.) (0. A)* Analog O V O V O V SP (0. A max.) SP (0. A max.) SP (0. A max.) Shown with G / Connection A Connection Chart Dimensions (in inches) Plug M 2 X pin Version with switching output Version with switching output and analog output Process Connections A B Pin (5 to 28 VDC) (5 to 28 VDC) Pin 2 SP2 (0. A max.) analog (-20 ma) Pin O V O V Pin SP (0. A max.) SP (0. A max.) /-8 NPT 2 G / -/8 7/6-20-SAE 2 Product Configurator Example SW N - Base Model SW2000 Solid State Pressure switch Pressure Ranges -0-A 0-5 PSIA (absolute) -0-A 0-75 PSIA (absolute) -05-A 0-50 PSIA (absolute) PSIG (gauge) Connection -N / NPT -P 7/6-20 SAE -G G / Options - Single switch plus -20 ma output -2 Dual switch capability (No analog output) -6 Single switch plus 0-0 volt output PSIG (gauge) PSIG (gauge) PSIG (gauge) PSIG (gauge) Accessory Order # Description Pin, M2 Electrical mating connector PSIG (gauge) 2 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #S00-D 0/ Printed in the U.S.A. 2

5 Solid State Electronic Pressure Switch Features Pressure control with internal stainless steel diaphragm Digital display 2 solid state outputs and analog output Dual switch with built-in transducer output High accuracy with fully adjustable deadband Built-in digital pressure readout Fully configurable via keypad Suitable for rapid cycling (00 times per second) UL/CSA approved Applications Hydraulic and pneumatic systems Process and chemical industry Test bench and instrumentation Automation equipment UDS7 Series General Specifications* Accuracy: Linearity Error: 0.5% FS Repeatability: ±0.% f. s. Sensor Element: Material: Wetted Parts: Seal: Measuring Ranges: Pressure Ranges (psi): Proof Pressure (psi): Process connection: Electrical Connection: Power Supply: Power Consumption: A/D-Converter: Resolution: Analog Output: Current Output: Load: Load Influence: Voltage Output: Rating: Adjustment Range: * See product configurator for additional options. ±0.5% f. s. at 77 F (25 C) Piezoresistive measuring cell Stainless steel 0 FKM (fluorelastomer) 0-5 psi to 0-50 psi, absolute pressure 0-50 psi to psi, gauge ,600 / -8 NPT 7/6-20 SAE, G/ male with rotatable fitting only Plug M 2 x, 5-pin 5 to 28 VDC Approx. 0 ma at 2 VDC (without load) 2 bit (096 steps per measure span) 00/s (for peak value memory) - 20 ma max. Rl = (2 V) / 20 ma Rl = 600 ohm at 2 V DC 0.% / 00 ohm 0 to 0 V DC (optional) max. 0 ma, short circuit-proof 0% to 25% f. s. Switching Output(s): Adjustment Range: Hysteresis: Switching Frequency: Contact Rating: Status Display(s): Digital Display: Display Range: Display Rate: Brightness: Error Display: Operating Elements: Temperature Range: Media: Electronics: Storage: 0 to 25% f. s. 0 to 25% f. s. max. 00 Hz 0.0 to 9.9 s - adjustable max. 00 ma, short circuit-proof LED(s) green -digit dot matrix display, height 5 mm, green -999 to 999 5/s adjustable 20-00% adjustable LED red and alphanumeric display easy response push buttons Temperature Influence: ±0.2% f.s. /0K Protection Class: Compensation Range: Approvals: Dimensions (Housing): Additional Features: - F to 22 F (-25 C to +00 C) F to 58 F (-0 C to +70 C) -22 F to 78 F (-0 C to +80 C) IP65 F to 58 F (-0 C to +70 C) UL, CE.2 x.7 inch (2 X 20 mm) (without electrical plug) Alphanumeric -digit dot-matrix display, microprocessor-controlled, self monitoring with error display, scalable analog output, all parameters are configured by keypad. Shipping Weight: approx. 0.8 lb. (50 g)

6 Electronic Pressure Switch Technical Drawings UDS7 Series 5 +Ub Plug 5-pin -/6 (20) UDS 7 SP2 2 SP...20 ma 0V 5 2 7/6 (2) -/ (2) (Mating connector included) Product Configurator Example UDS7-05 -N - -E Base Model UDS7 Pressure Range -0-A 0-5 PSIA (absolute) -0-A 0-75 PSIG (absolute) -05-A 0-50 PSIG (absolute) PSIG PSIG PSIG PSIG PSIG PSIG Process Connection -N / NPT -P 7/6-20 SAE -G G/ Optional -E EPDM seal Output - Dual switch plus -20 ma output -6 Dual switch plus 0-0 VDC output Connection Chart Plug M 2 X 5 pin Pin Model with 2 switching outputs and analog output +Ub (8-2 V DC) Accessories Order # Description Pin, M2 electrical mating connector Pin 2 Pin Analog - 20 ma/ 0-0 V DC O V Pin SP 0.5 A max. Pin 5 SP2 0.5 A max. 2 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #S00-F 02/ Printed in the U.S.A. 2

7 Solid State Explosion Proof Electronic Pressure Switch Features ATEX Certified Construction Dual seal protection Adjustable set point delay - up to 9.9 seconds 2 set points and analog output High accuracy with fully adjustable deadband Digital readout Fully configurable via keypad Suitable for rapid cycling (00 times per second) NEMA, 7, 9 & IP65 Applications Oil & gas pipelines Refineries Petrochemical plants Pulp and paper mills Coal and oil fired power plants Cement plants Gas transfers for fuel systems UDS7-BX General Specifications* Accuracy: Linearity: Repeatability: Sensor Element: Wetted Parts: Proof Pressure: Process connection: Electrical Connection: Power Supply (V s ): Power Consumption: A/D-Converter: Resolution: Analog Output: Current Output: Load: Load Influence: Voltage Output: Rating: Adjustment Range: Switching Output(s): Adjustment Range: Deadband: Switching Frequency: Contact Rating: Status Display(s): ±0.5% FSO at 77 F (25 C) TYP ±0.5% FSO at 77 F (25 C) ±0.% FSO at 77 F (25 C) Piezoresistive measuring cell 6 and 7- PH stainless Steel 2X rated pressure or,000 psi (88 bar), whichever is less /-8 NPT Female Internal screw terminal strip via conduit connection / - NTPF 8 to 28 VDC Approx. 0 ma at 2 VDC (without load) 2 bit (096 steps per measure span) 00/s (for peak value memory) - 20 ma max. R Loop = (V S -2)/.020A 0.% / 00 ohm 0 to 0 V DC (optional) max. 0 ma, short circuit-proof 0% to 25% FSO 0 to 25% FSO 0 to 25% FSO max. 00 Hz 0.0 to 9.9 s - adjustable max. 00 ma, short circuit-proof LED(s) green Digital Display: Display Range: Display Rate: Brightness: Error Display: Operating Elements: Temperature Range: Media: Electronics: Storage: -digit dot matrix display, height 5 mm, green -999 to /s adjustable 20-00% adjustable LED red and alphanumeric display easy response push buttons - F to 22 F (-25 C to +00 C) F to 58 F (-0 C to +70 C) -22 F to 78 F (-0 C to +80 C) Temperature Influence: ±0.2% FSO /0K Protection Class: Compensation Range: Approvals: Additional Features: Shipping Weight: NEMA, 7, 9 & IP65 F to 58 F (-0 C to +70 C) CE008 ISSeP 09 ATEX 0 5X II 2 GD Ex d II C T6 Ex D A2 IP65 T80 C -0 C Alphanumeric -digit dot-matrix display, microprocessor-controlled, special Watchdog feature monitors and displays errors, scalable analog output, all parameters are configured by keypad. approx. 9. lb. * See product configurator for additional options.

8 Explosion Proof Electronic Pressure Switch Technical Drawings Wiring Connections UDS7-BX / NPTF Electrical Interface Port Chassis Ground Lug UDS7-BX Analog Ground Connection Chart Terminal Connection 6-Position Pin Pin 2 Description Voltage (Ub): 8-28 VDC Analog - 20 ma or 0-0 V DC Pin Common (-) / NPTF Process Connection Pin Pin 5 Pin 6 SP: 0. A Max SP2: 0. A Max Internal Ground Product Configurator Example UDS7-BX ZXXY Base Model UDS7-BX Pressure Range PSIG (0-.5 BAR) PSIG (0-. BAR) Optional -ZXXY Special Pressure Ranges* -Q Custom Modification (Consult Factory) PSIG (0-69 BAR) PSIG (0-0 BAR) PSIG (0-8 BAR) PSIG (0-207 BAR) Output - Dual switch plus -20 ma output -6 Dual switch plus 0-0 VDC output PSIG (0-276 BAR) PSIG (0-5 BAR) PSIG (0- BAR) PSIG (0-57 BAR) PSIG (0-689 BAR) *Add suffix ZXXY for special pressure range calibration. XX = significant digits. Y = number of trailing zeros. Example: 0 psi calibration: add -Z. 2 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #S007-A 0/0 200 Printed in the U.S.A. 2

9 Solid State Multiple Output Electronic Switch UDS Series Features Pressure control with internal stainless steel diaphragm switching outputs and analog output High accuracy with fully adjustable deadband Easy-to-read LCD display with scalable bar graph Capable of switching both AC and DC loads Fully configurable via keypad UL/CSA approved Applications OEM-applications in hydraulics and pneumatics Test bench Industrial machinery General Specifications* Accuracy: 0.5% f. s. Linearity Error: Repeatability: ±0.% f. s. Sensor Element: Wetted Parts: Housing: Seals: Keypad: Measuring Ranges: Pressure Ranges (psi): Proof Pressure (psi): Process Connection: ±0.5% f. s. at 77 F (25 C) Piezoresistive silicon measuring cell 0 stainless steel Cast aluminum FKM Polyester film 0-9,000 psi, gauge ,600 / NPT F Option : G/ F, bottom entry Electrical Connection: Plug-in, terminal strip with slots for.5 mm 2, AWG slots Power Supply: A/D-Converter: Resolution: Time Constant: Analog Output: Current Output: Load: Load Influence: Voltage Output: Rating: Adjustment Range Switching Output(s): Switching Function: Contact Rating: 8-2 VDC, reversed polarity protected 2 bit (096 steps per span) 000 / s Approx. 0s * See product configurator for additional options. -20 ma max. Rl = (Ub-2 V) / 20 ma Rl= 600 Ohm at Ub = 2 VDC 0.% / 00 Ohm ms 0-0 VDC max. 0 ma, short circuit-proof 25% to 00% f. s. Normally open / normally closed, analog output, standard-/windows-mode max. 20 VDC / 250 V AC max. 2 W / 250 VA Switching Output(s) Cont.: Cycles: Switching Rate: Operation Time: Status Display: Digital Display: Height: Bargraph: Trend Arrows: Display Range: Display Rate: Display Unit: Operating Elements: Temperature Range: Media: Electronics: Storage: 2 VDC/2A max. 20 / s 0.0 to 9.9 s adjustable ms S to S on LCD display 8-digit -segment LCD display 0.5 in. (green) 20-segments Last value change to 9999 / s bar / psi / psi x 0 / hpa / mbar / C / F Keypad with easy response push buttons - to 22 F (-25 C to +00 C) to 58 F (-0 C to + 70 C) -22 to 76 F (-0 C to + 80 C) Temperature Influence: ±0.2% f. s. /0K Compensation Range: Power Consumption: Protection Class: Dimensions (Housing): Cable Gland: Additional Features: Weight: to 58 F (-0 C to +70 C) appr. 50 ma at Ub = 2 V DC (without load) IP65.9 (W) X 5. (H) X. (D) inches [00 (W) X 5 (H) X 80 (D) mm] x PG.5 side entry = standard 8-digit -segment LCD display with bargraph and trend indication, microcontroller, self monitoring, all parameters are configured by keypad, selective keypad lock, high accuracy, quick scanning rate ( ms). Approx. 2 lb

10 Multiple Output Electronic Switch Technical Drawings UDS Series CABLE GLAND 5-5/6 (5) Electrical Connection S Switch.-cont. S S2 S Analog Output Analog GND (0 V) - 20 ma (0-0 V) Power Supply OV +8 V DC - +0 V DC S S S2 S Earth PRESSURE CONNECTION -/6 (80) Product Configurator Example UDS -05 -N - Base Model UDS Pressure Ranges PSIG (gauge) PSIG (gauge) PSIG (gauge) PSIG (gauge) PSIG (gauge) Options - Four switches only (no analog output) -5 Four switches plus -20 ma output -6 Four switches plus 0-0 VDC output Process Connection -N / NPT -G G/ PSIG (gauge) Accessory Order # Description Pin, M2 Electrical mating connector 2 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #S006-C 09/ Printed in the U.S.A. 2

11 Solid State Electronic Trip Amplifier UAS Series Features Integrated trip amplifier 2-bit analog-digital converter For pressure, temperature, level and flow Monitors and controls any sensor with analog output Ideal companion to our 00-series pressure transducers Four switchpoints in a single, compact unit Easy-to-read LCD display with scalable bar graph UL/CSA approved Applications OEM-applications in hydraulics and pneumatics Test bench Industrial machinery General Specifications* Accuracy: 0.2% f. s. Linearity Error: Repeatability: ±0.0% f. s. Material: Housing (Electronics): Seal (Housing): Keypad: ±0.2% f. s. at 77 F (25 C) Cast aluminum Neoprene Polyester film Measuring Ranges: (free scalable): to Measuring Principle: Amplifier with 2 Bit A/D-converter Electrical Connection: Plug-in, terminal strip with slots for.5mm 2, AWG slots Sensor Connection: Plug -pin acc. to DIN 650 / meter including electrical plug with molded cable Cable Gland: x PG.5 side entry - standard Power Supply: Power Consumption: A/D-Converter: Resolution: Analog Inputs: Current Input: Voltage Input: Resistance Input: Temperature: Analog Output: Current Output: Load: Load Influence: * See product configurator for additional options. 8-0 VDC, reversed polarity protected appr. 50 ma at Ub = 2 VDC (without load) 2 bit (096 steps per measuring span) 000 / s - 20 ma 0-0 VDC kohm PT00 element acc. to IEC75-20 ma max. Rl = (Ub-2 V) / 20 ma Rl = 600 Ohm at Ub = 2 VDC 0.% / 00 Ohm ms Analog Output (Cont.): Voltage Output: Rating: Adjustment Range: Switching Output(s): Contact Rating: Cycles: Switching Rate: Operation Time: Status Display: Digital Display: Bar Graph: Display Range: Display Rate: Display Unit: Operating Elements: Temperature Range: Electronics: Storage: Temperature Influence: Compensation Range: Protection Class: Dimensions (Housing): Additional Features: 0-0 V DC max. 0 ma, short circuit-proof 25% to 00% f. s. max. 20 VDC / 250 VAC max. 20 W / 250 VA million at 2 VDC / 2 A max. 20 / s s adjustable ms S to S on LCD display 8-digit -segment LCD display, height /2 in (2 mm) 20-segment to (scalable) /S psi / bar / kpa / C / F Keypad with easy response push buttons to 58 F (-0 C to + 70 C) -22 to 76 F (-0 C to + 80 C) ±0.05% f. s. / 0K to 58 F (-0 to +70 C) IP65-5/6 W X 5-5/6 H X -/6 D (00 W X 5 H X 80 D) Weight: appr. 2 lb (080 g) 8-digit -segment LCD display with bargraph and trend indication, microcontroller-controlled, self monitoring, all parameters are configured by keypad, selective keypad lock, high accuracy, quick scanning rate ( ms).

12 Electronic Trip Amplifier UAS Series Technical Drawings COVER IS 80 REVERSIBLE Electrical Connection S Switch.-cont. S S2 S Analog Output Analog GND (0 V) - 20 ma (0-0 V) Power Supply OV +8 V DC - +0 V DC S S S2 S Earth Barksdale CONTROL PRODUCTS 5-/8 (5) Sensor Connection acc. to DIN 650 M S S2 S S -7/6 (87) = +Ub 2 = -Ub (*) = Signal 2 gn bn ws -Ub 2 Signal +Ub -/8 (0) -/8 (80) Analog measuring input By choice: Current input : - 20 ma Voltage input : 0-0 V DC Resistance input : Poti (500 Ohm - 00 Kohm) Product Configurator Example UAS -5-6 Base Model UAS Input Options ma analog input VDC analog input Output Options Four switchpoints with no analog output Four switchpoints with -20 ma analog output Four switchpoints with 0-0 VDC analog output 2 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #S005-D 0/ Printed in the U.S.A. 2

13 Global Presence Global Presence Barksdale Inc. 2 Fruitland Ave. Los Angeles, CA U.S.A. Phone: (800) Fax: (2) sales@barksdale.com Barksdale GmbH Dorn-Assenheimer Strasse Reichelsheim, Germany Phone: (9) (main office) (9) (sales) Fax: (9) /- info@barksdale.de Barksdale GmbH Dorn-Assenheimer Strasse Reichelsheim, Germany Phone: (9) (main office) (9) (sales) Fax: (9) /- info@barksdale.de Barksdale India SF-, Ansal Fortune Arcade Sector 8 India-200 Noida Phone: Fax: manojsingh@barksdale.in

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer PT-400 Heavy Duty, Amplified Output Pressure Transducer C US The PT-400 offers high accuracy and reliability over a wide range of pressures. The small size, integrated electronics, wide operating temperature

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

Conductive Level Switch FK 2 Technical Data:

Conductive Level Switch FK 2 Technical Data: Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

Digital display DA 48

Digital display DA 48 Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital

More information

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

Typical Aluminum GFM Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.

More information

Technical Information RIA14

Technical Information RIA14 TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information

B-Series Switches Pressure, Differential Pressure & Hydraulic

B-Series Switches Pressure, Differential Pressure & Hydraulic FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment

More information

PIEZOMETER AIRFLOW MEASURING RING

PIEZOMETER AIRFLOW MEASURING RING PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

RPS 8000. High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

RPS 8000. High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features: GE Measurement & Control Solutions RPS 8000 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement. and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the

More information

Mass Flow Meters & Controllers

Mass Flow Meters & Controllers HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2% of Full Scale) 0-5 VDC or 4-20

More information

Data Sheet PS1B Pressure Switch

Data Sheet PS1B Pressure Switch Data Sheet PS1B Pressure Switch Main Features Pressure Ranges 0 to 6 up to 0 to 600 bar (gage) Electrical Connection G 1/4 A DIN 3852-E or -A Pressure Connection Output Signal M12-4 Pin 4-20 ma, Programmable

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

www.suco.de Electronic Pressure Monitoring New Products

www.suco.de Electronic Pressure Monitoring New Products Electronic Pressure Monitoring New Products RoHS compliant Electronic Pressure Switches SoS-Technology with one or two switching functions Electronic Pressure Switches CE marking SUCO Electronic pressure

More information

LED...A70..4-..Q Series Sealed High-Intensity

LED...A70..4-..Q Series Sealed High-Intensity LED...A70..4-..Q Series Sealed High-Intensity Area Lights High-Power Lighting for use with PresencePLUS and Other Vision Systems Features Rugged, waterproof housing, rated IEC IP68 Compact area light for

More information

Relative and absolute pressure switch type 529

Relative and absolute pressure switch type 529 Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89] Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Series 6000 Torque measured metal bellow coupling

Series 6000 Torque measured metal bellow coupling Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

In-Line Electronic Flow Switches

In-Line Electronic Flow Switches In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the

More information

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation

More information

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100 Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

OEM-EP Pressure Controllers

OEM-EP Pressure Controllers Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

Features. Picture. Specifications

Features. Picture. Specifications Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

DPI 260 SERIES: Digital Pressure Indicators

DPI 260 SERIES: Digital Pressure Indicators DPI 260 SERIES: Digital Pressure Indicators INTRODUCTION The DPI 260, 261 and 262 range of digital pressure instruments measure and indicate pressure in any specified scale units and provide accuracies

More information

Barksdale, Inc. Los Angeles, CA 90058 Specifications are subject to modification at any time Bulletin #M0017-B 03/14 2014 Printed in the U.S.A.

Barksdale, Inc. Los Angeles, CA 90058 Specifications are subject to modification at any time Bulletin #M0017-B 03/14 2014 Printed in the U.S.A. Barksdale Inc. 3211 Fruitland Ave. Los Angeles, CA 90058-0843 U.S.A. Phone: (800) 835-1060 Fax: (323) 589-3463 Email: transportation@barksdale.com www.barksdale.com Barksdale GmbH Dorn-Assenheimer Strasse

More information

Liquid Level Limit Switch liquiphant T FTL 20

Liquid Level Limit Switch liquiphant T FTL 20 Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid

More information

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service

More information

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

KNC Model 3666 Automatic Pressure Calibration System

KNC Model 3666 Automatic Pressure Calibration System KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

RPS/DPS 8100. High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

RPS/DPS 8100. High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features: GE Measurement & Control RPS/DPS 8100 High Accuracy Resonant Pressure Sensor For over 40 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial,

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020 Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and vibration resistant

More information

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Series 7500 Torque Sensor

Series 7500 Torque Sensor Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Model 111 Mass Flow Instruments

Model 111 Mass Flow Instruments 111 Mass Instruments Porter Mass products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement and control of gas flow. They incorporate design

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Models SFP33 & SFP32 Pressure Transmitters

Models SFP33 & SFP32 Pressure Transmitters SFP33 Flow-Through Pressure Transmitter SFP32 Single-Ended Pressure Transmitter DS-PR-SFP-eng April, 2016 Data Sheet Models SFP33 & SFP32 Pressure Transmitters Pressure Brooks Seal Free Pressure Measurement

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented

More information

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370 Pump_TM016 Pump Local Display TM0200 TM0200 4-20mA PLC/DCS Case 1 Pump Relay Output Module 4-20mA Optional PT371 Modbus PT373 Case 2 PCM370 TM016 Velocity/ Acceleration Vibration Transmitter Introduction

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief

More information

B-Series Temperature Switches

B-Series Temperature Switches FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Product Catalogue. AP Automatyka +48 67 357 10 80 biuro@apautomatyka.pl www.apautomatyka.pl ISO 16949 ISO 14001 OHSAS 18001 ISO 9001.

Product Catalogue. AP Automatyka +48 67 357 10 80 biuro@apautomatyka.pl www.apautomatyka.pl ISO 16949 ISO 14001 OHSAS 18001 ISO 9001. Product Catalogue ISO 16949 ISO 14001 OHSAS 18001 ISO 9001 Marine Division Since 1945 your qualified partner 1945 Huba Control AG founded 1974 Taken over by Stäfa Control System AG 1990 Concentration

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13 CONTENTS PAGE Chapter 1 General Information 1 Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13 Chapter 3 Alarm/Excitation Options 15 Wiring 17 Chapter

More information

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings. TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant

More information

Flow switches Series AD/VH

Flow switches Series AD/VH Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Electronic Product Catalog

Electronic Product Catalog Electronic Product Catalog Electronic Product Catalog Pressure Transmitters and Transducers General Purpose Pressure Transmitters Hazardous Area Pressure Transmitters Submersible Liquid Level Transmitters

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES

Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES Precision Gage/Absolute Transducer DESCRIPTION Model TJE pressure transducers are all-welded stainless steel sensors built for rugged industrial applications that require high accuracy and measurement

More information

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular

More information

MicroMachined Silicon modular pressure sensor

MicroMachined Silicon modular pressure sensor MicroMachined Silicon modular pressure sensor Configurable High Accuracy High Temperature Performance For Industrial, Test and Measurement, and Aerospace Applications Low Pressure from 10 in-h 2 O to 2.5

More information