Modular Make-Up Air Unit



Similar documents
SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Element D Services Heating, Ventilating, and Air Conditioning

CE6500 Energy Recovery Ventilator

Johnson Air-Rotation Systems

Bring the fresh in. Dedicated Outside Air Systems

SECTION HEAT PUMPS

Mechanical Rooftop Custom Capabilities

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

SECTION AIR CONDITIONING UNIT

SECTION MORTUARY REFRIGERATORS

RPV - RP - RA air handling units

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

Innovent LASER Packaged Fresh Air Conditioning Units

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

MAC-120HE-01 Air-Cooled Chiller

Low Profile Unit Cooler

A. Section includes air conditioning units, controls and control panels.

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION BLOWER COIL UNITS

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W70A1 W70L1. Models: Contents. General Notes. Important. Description

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Glossary of Heating, Ventilation and Air Conditioning Terms

ARMSTRONG AIR HEAT PUMPS

catalog Single Package Vertical Air Conditioners and Heat Pumps

Commercial Gas Furnace Upflow

Direct Gas-Fired Indoor and Outdoor Heating and Make-Up Air Units

1.2 Refrigerant Equipment. General

Installation Manual CLIFC Fan & Coil Variable Speed

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

SECTION GENERAL PROVISIONS FOR HVAC WORK

FOXAIR 60/50 ALL MODELS

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

Direct Gas Fired [Make-Up Air / Displacement Ventilation / Space Heating] System

ROOF TOP MOUNTED Air Handler Specification

ECOCIAT. Domestic hot water heat recovery unit

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

University of Houston Master Construction Specifications Insert Project Name

AFHX Guide Specifications

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Defining Quality. Building Comfort. Heating and Cooling Coils

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Housing

HVAC Checklist - Long Form

Commercial Semi-Instantaneous Water Heaters

Utility Distribution Systems

MULTIZONE APPLICATION OF SOLUTION UNITS

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

HEATER, AIR CONDITIONING AND VENTILATION

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

Chilled Water HVAC Systems

COMMISSIONING OF HVAC SYSTEMS

CB29M Bulletin # February 1996

Legacy Chiller Systems, Inc

"EC" Series Electric Humidifier

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

"ES" Series Electric Humidifier

Diesel Engine Driven Generators Page 1 of 6

Dehumidification Frequently Asked Questions

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

CHILLED WATER DATA ROOM UNITS

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

Why is my air conditioner dripping on my customers?

Cooling/Heat Pump Convertible Air Handlers

DUCT SMOKE DETECTOR D4120

HVAC Processes. Lecture 7

APC APPLICATION NOTE #112

GCS16 GCS20 WARNING CAUTION

General Safety Information. Document Packaged DX Module. As used in Greenheck models DGX IGX MSX

marine/bespoke split applications

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

WATER COOLED SELF CONTAINED MODEL LSWU/LSWD WITH IPU2 CONTROL

SWIMMING POOL HEAT PUMP

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Lesson 36 Selection Of Air Conditioning Systems

Operation and Installation Manual. Max Series

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Air-Cooled Condensers

Single Package Vertical Air Conditioners. Vert-I-Pak

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

Basics of HVAC Cleaning

Split System Cooling Product Data

Medical Air Systems: Scroll

ASTACEA4 Inspect complex/central air conditioning systems

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

PACKAGE AIR CONDITIONERS REPLACEMENT PARTS MANUAL

Offshore Substation. HVAC System. ETS-09 Rev. 2. technical standards. Dok Sag 09/1437

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Oil and Coolant Circulating Heating System. Model - OCSM

Transcription:

Modular Make-Up Air Unit Model MSX Configurable Design 800-48,000 cfm 4 in. wg External Static Pressure Hot Water, Electric or Steam Heating Packaged DX (3 to 16 tons), Split DX Cooling, Chilled Water or Evaporative Cooling Forward-Curved or Direct Drive Backward-Curved Plenum Supply Fan Options September 2015

Product Overview Model MSX Modular Supply Unit The Greenheck model MSX is an ideal make-up air unit where gas-fired heating is not desired or available. Coil heating and/or cooling tempering options are available with airflow volumes up to 48,000 cfm. The MSX may also be used for untempered applications. A flexible design concept enables each product to be customized for its application. Units are factory-assembled and wired to minimize field installation labor. The result is a semi-custom product at an attractive cost. Heating Options Hot water, steam and electric heat options are available. The heating section consists of a factory-installed heating coil in a pre-engineered housing. Water and steam coil connections are stubbed through the wall for installation convenience. The heating coil section is installed upstream of the fan section for a draw-thru arrangement and provides a streamlined transition to adjacent sections. For proper coil sizing, use Greenheck s CAPS selection software or contact your local representative. Hot Water and Steam Hot water and steam distributing coils are available in either a 100% thru-coil airflow or face and bypass arrangement. Coils have copper tubes with permanently expanded aluminum fins and are tested and rated in accordance with AHRI 410. Available with airflow capacities up to 40,000 cfm. Cooling Coils MSX model shall be ETL Listed to UL1995 MSX shown with optional filter section, hot water coil, forward-curved supply fan and end discharge. Electric Heat Electric heaters are UL Listed and feature open coil heating elements. Heater control cabinets are installed completely within the heating section and are factory wired up to 218 kw. All units with electric heat include a single-point power connection. Both chilled water and direct expansion coils for split systems are available. The cooling section includes the cooling coil, double-pitched stainless steel drain pan sloped in opposite directions for positive draining, and insulated double-wall construction. Drain and coil connections are stubbed through the wall for convenience. Chilled Water Coils: Available from two to six rows and numerous circuiting configurations to meet various load conditions. Airflow ranges up to 11,700 cfm in both water and glycol applications. Coil performance shall be calculated in accordance with AHRI 410. Direct Expansion (DX) Coils: DX coils for use in split systems are available from two to six rows. Circuiting options include single, face-split, and interlaced arrangements. 2 All heating and cooling coils can be coated with an ElectroFin coil coating upon request!

Tempering Options Packaged Direct Expansion (PDX) Providing unconditioned make-up air through ceiling diffusers or perforated kitchen hood plenums can create an uncomfortable work environment during summer months in commercial kitchens. Although conditioned make-up air can increase comfort levels, the need to cool and dehumidify this air to a 55 F supply air temperature can be detrimental to the food preparation process, significantly increase equipment first cost, and annual energy cost. The packaged DX cooling option is designed to cool the kitchen make-up air to a 70-75 F supply air condition to improve space comfort and enhance employee productivity at an economical first cost while keeping energy costs low. Airflow Arrangement - Optional variable air volume or 100% outdoor air constant volume Performance Range - 1,000 to 7,500 cfm Cooling Capacity - 3 to 16 nominal cooling tons All units selected with the PDX option include: Efficient, direct drive condenser fans that are statically and dynamically balanced. Condenser and evaporator coils with copper tubes mechanically expanded in aluminum fins. Evaporator coils are mounted on a stainless steel drain pan. Thermal expansion valves provide refrigerant control. Quiet-running, hermetic scroll-type compressors mounted in an isolated compartment to be serviceable without affecting airflow. Mounted on neoprene isolators to minimize vibration transmission and noise. Features Draw-thru cooling arrangement Standard high and low pressure cutouts and crank case heaters Low discharge temperature cutout Benefits Even airflow across coils for efficient cooling operation and less chance of water carryover Increased compressor life Prevents coils from freezing Evaporative Cooling The evaporative cooling section includes a galvanized steel housing with a louvered intake, 2-inch aluminum mesh filters and a stainless steel evaporative cooling frame around the media. The evaporative cooling media is Munters CELdek or GLASdek and has a depth of 12 inches for 90% cooling effectiveness. The entire section mounts directly to the front of the unit, eliminating transition or ductwork by others. Drain and overflow are conveniently tapped through the side of the cooling section. The supply line connection is field located where convenient. Airflow capacity for evaporative cooling is up to 48,000 cfm. The evaporative cooling section for units above 9,000 cfm ships separately. Control Options: Recirculating Pump: Includes a pump that recirculates water over the evaporative media and is activated by a call for cooling. A field-adjustable bleed-off valve keeps mineral concentrations low. Auto Drain and Flush: Includes a recirculating pump and a field-adjustable timer that will periodically flush the sump to minimize mineral build-up. 3

MSX Standard and Optional Features 1 S Standard Feature O Optional Feature Construction Constructed of heavy-gauge G90 galvanized steel Single or double-wall construction with 1-inch fiberglass insulation Removable access panels with optional hinged doors Available finishes include: - Permatector (1,800 hr/salt spray rating under ASTM B117 testing conditions) - Hi-Pro Polyester (4,000 hr/salt spray rating under ASTM B117 testing conditions) - Baked Enamel coatings available in 16 standard colors or custom color match 5 1 Heating Options Hot water coils Standard steam coils Steam distributing coils for improved freeze resistance Face and bypass steam or hot water coils Electric heater up to 218 kw with a single-point power connection 2 Weatherhood Weatherhood with birdscreen features a wire mesh intake, preventing large debris from damaging the filters. An additional filter section is required. Aluminum mesh filtered weatherhood eliminates the need for an additional filter section Louvered weatherhood includes a drainable blade louver at intake with 2-inch aluminum mesh filters 2 3 4 5 6 7 3 Dampers Low-leakage non-insulated inlet damper with factory-mounted and wired actuators Low-leakage insulated or non-insulated outlet damper 4 Filter Section V-bank filter section or mixing box 2-inch washable aluminum mesh 2-inch MERV 8 pleated disposable 2-inch MERV 13 pleated disposable 4-inch MERV 14 pleated disposable 2-inch MERV 8 and 2-inch MERV 13 pleated disposable 2-inch MERV 8 and 4-inch MERV 14 pleated disposable 6 Cooling Options All cooling options include a stainless steel drain pan Evaporative cooler Chilled water coils Split DX coil (coils only) Packaged direct expansion (PDX) Includes condensing fans and coils. Only available on forward-curved fan models. 4

7 8 8 9 9 Control Center 24 volt control voltage Magnetic motor starter with solid state overload protection Control transformer Disconnect switch Distribution terminal strip UL Listed, Recognized, or Classified electrical components Factory prewired for single-point power connection Supply Fan Options Forward-curved fan with optional factoryprovided VFD Direct drive backward-curved plenum fan with factory-provided VFD (shown) Balanced wheels to ensure a vibration-free operation Vibration Isolators The entire fan and motor assembly is mounted on vibration isolators to minimize noise transmission into the building. Neoprene or spring isolators are available on forward-curved supply fan models. Backward-curved supply fan models only offer neoprene isolators. Optional Electrical Controls Auxiliary Contacts Normally open and normally closed contacts are available for supply fan status and supply fan interlocks. Coil Freeze Protection Adjustable temperature sensing capillary tube which will disable the fan motor at 35ºF. This freeze protection is NOT a substitute for draining of water-filled coils. Cooling Relay When interlocked with a rooftop unit (RTU), this relay can be used to lockout a call for heat from the make-up air unit when there is a simultaneous call for cooling from the RTU. Dirty Filter Sensor Monitors the pressure drop across the filter section. If the pressure drop is higher than the field-adjustable setting, the switch will trip and indicate that the filters need to be cleaned or replaced. An indicator light may be wall/beam mounted or provided with a remote panel. Exhaust Fan Starter(s) Factory-mounted and wired for an electrical interlock between the supply and exhaust fan(s). Fire Stat Type III Shipped loose for field mounting and wiring in the supply or return air duct. Contains two normally open and two normally closed contacts for alarm notification. Freeze Protection Automatically shuts down the supply fan when the discharge temperature is below the set point for an extended amount of time. This prevents the unit from discharging non-tempered air into the building and freezing pipes and other temperature sensitive items. Heating Inlet Air Sensor Automatically turns the heat on and off based on a field-adjustable set point. Inlet Damper End Switch Will not allow starter to engage until end switch is proved, ensuring that the inlet damper is fully open before unit operation. Service Receptacle A 115 volt GFCI outlet can be shipped loose or mounted externally in a NEMA 3R box for the convenience of service personnel. A separate 115 volt power source is required. Smoke Detector Shipped loose for field mounting and wiring in the supply or return air duct. Contains two normally open and two normally closed contacts for alarm notification. 5

Unit Options and Controls Mixing Box The mixing box option expands the make-up air application capabilities of the unit. This section includes low leakage control dampers for outdoor and return air and an actuator in a face and bypass configuration. Either 2-inch pleated disposable or 2-inch aluminum mesh filters are available within the mixing box section. Double wall construction is available. Weatherhoods with a mixing box include a louvered intake with 2-inch aluminum mesh filters to prevent moisture from entering the mixing box section. Control Options: Building Pressure Control: Outdoor air and return air dampers modulate to maintain desired building pressure. Furnace control is based on discharge temperature. A remote control panel with photohelic gauge is required with this option. Potentiometer Control: Enables manual control of the outdoor air and return air damper positions. A remote control panel is required with this option. External Signal: Outdoor air and return air dampers modulate based on an external 2-10 VDC or 4-20 ma signal. Unit Controls Remote Panel - Greenheck offers three types of remote control panels featuring a variety of switches, thermostats, temperature selectors and indicator lights. Installation and field-wiring is easy by using a numbered terminal strip for point-to-point wiring between the make-up air unit and the remote panel. Industrial/Severe Duty: The industrial panel features a variety of switches and indicator lights mounted on a Permatector coated steel box in a NEMA-1 enclosure. The severe duty offers a variety of indicator lights and switches mounted in/on a stainless steel panel satisfying the following NEMA enclosure requirements: 3, 3R, 4, 4X, 12. Kitchen (KSCP): Features toggle switches for kitchen hood lights, fans and tempering. A stainless steel faceplate for flush wall mounting and a junction box is included. Network Interface Controller - An optimum solution for connecting a make-up air unit to a Building Management System (BMS). The network interface controller offers an easy-to-use, remote-mounted display. It easily integrates to BACnet IP, BACnet MSTP, LonWorks or Modbus. Two operating options are available: Monitor only: Allows the BMS to monitor the status and functions of the unit through a factory-installed controller. Control commands will be provided by terminal style signals from a remote panel or external to the unit. Monitor and Control: Allows the BMS to monitor the status and command the basic functions of the unit through a factory-installed controller. A remote panel is not available with this option. 6 Model Number Code The model number code is designed to completely identify the unit. The correct code letters must be specified to designate the configurations and size. *If no P is shown, then a forward-curved fan is provided. Model Parent MSX - P115 - H22 Optional Fan *P - Backward-Curved Plenum Housing Size 12-42 Wheel Diameter (in.) 8-36 Fan Quantity 1

Intake and Discharge Options Weatherhoods Birdscreen Filter Section Aluminum Mesh Filtered Supply Fan Options Louvered V-Bank Mixing Box Forward-Curved Backward-Curved Discharge Options Top or Bottom Discharge Left or Right Discharge (only available on backwardcurved plenum option) End Discharge Kitchen Combination Packages The Greenheck combination package simplifies installation and reduces field labor costs for kitchen ventilation systems. The pre-engineered design ensures that the supply fan, exhaust fan, curb and combination extension components interface properly. Equally important, Greenheck combination packages are specifically designed to comply with NFPA 96. NFPA 96 states: Exhaust duct must terminate at least 24 inches above the roof deck Fan discharge must be at least 40 inches above the roof deck Air intake shall have a horizontal separation of 10 feet from the exhaust discharge Consult local codes and the authority having jurisdiction if there are questions concerning the use of this product. 7

Additional Make-Up Air Products Direct Gas - Economy Model DGK Indirect Gas - Economy Model IGK Direct Gas - Standard Model DG Indirect Gas - Standard Model IG Direct Gas - Configurable Model DGX Indirect Gas - Configurable Model IGX Direct Gas - Industrial Model TSU Direct Gas - Vertical Model VSU Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Greenheck P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com Prepared to Support Green Building Efforts Copyright 2015 Greenheck Fan Corp. 00.TAP.1029 R4 9-2015 IW