Talk-A-Phone Co. Model WEBS-MT/R OP5 Emergency Phone Tower Mount Architectural & Engineering Specification rev. 10/28/2011



Similar documents
Talk-A-Phone Co. Model WEBS-MT/R Emergency Phone Tower Mount Architectural & Engineering Specification rev. 08/29/2011

TALKAPHONEPROUDLYPARTNERSWI

VOIP-500 Series Phone Quick Installation Guide

INTRUSION DETECTION SYSTEM Section

One Room One Cable Architectural Specification

TrueAlarm Fire Alarm Systems

2 Ohm Nominal Coaxial Speaker OWNER S MANUAL

Operation and Installation Manual

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

B. Equipment shall be furnished and installed as specified. No substitutions will be allowed.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

VALCOM ONE-WAY PAGING SYSTEM DESIGN/INFORMATION

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

Canopy Surge. User Manual

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

AXIS T81B22 DC 30W Midspan

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

pr2969v eps FEATURES pr2961v eps

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

PS6500 Storage Arrays Rack Mount Instructions

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Emergency Communications Stanchion Applications (Solar/Wireless/Surveillance)

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

MODEL HSR-007 Direct Drive Rolling Steel

BACnet Automation Interface Module (Network Version)

PagePac PAGEPAL V

HMI display Installation Guide

IP Intercom System. Classroom intercom system for two-way voice communications, help desk support, and security/status monitoring.

Model SRMD Setra Remote Monitoring Display

A1.5 Classroom Standards

IP Intercom System

Lightning Arresters P KVA P KVA. Description & Installation

LOXONE 12 Channel Amplifier

Appendix A - Cost Estimate Spreadsheet

SECTION PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines

FLEX by 3M Light Module System

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

LED Sign Module. LED Super Tiny Strip. LED Accessories. LED Power Supply

Applied Electronics. Commercial Dimming System UPDATE NOTICE

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

User manual Rev 1.3 Contents

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Ethernet Cat 5e & Cat 6 Patch Panels

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

High Resolution Media Display - B series 20mm Pitch Outdoor RGB Module

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Automatic Door Selection Guide

VALCOM HANDSFREE TALKBACK PAGING SYSTEM DESIGN/INFORMATION

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

WIRELESS READER INTERFACE - INDOOR

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

For Dealers / Integrators / Architects. IS Series. Video Intercom. Building Communication. Controlling Security.

Fiber s Role in the Video Security & Surveillance Network. Curt Carlson Product Manager Transition Networks

Fire Alarm System Plans Review Checklist Property location Date of Review

LIEBERT VNSA Installation Sheet

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

FIRERAY 2000 Installation Guide

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Ceramic Glass Electric Galley Ranges

EVOline Multimedia Modules

Bi-Directional Amplifier Systems

V25 Series ArmorDome CCTV Camera User Guide

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

2013 Wireless Video Intercom INSTALLATION GUIDE

Product Specification instalert Rapid Messenger Variable Message Sign

A/V and Video Conference Standards for Teaching and Learning Rooms.

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

PRO 5000 CPE 1D Quick Installation Guide

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec

HM-W536 Install Guide

Analog Door Phone Model LUADS MAT Code #

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

E Series. E Series. Category 6 and 5e. Features

Fire Fighter Phone System Installation Instructions

TITAN TITAN THE HIGH BAY SERIES

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

ALARI LED PARKING, ROADWAY & AREA LIGHTING

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual.

Please check with your local inspection authority for any additional requirements before installation.

Office of Integrated Security Systems Longwood University Camera System Standards

MCR1900 Media Converter 19-Slot Chassis

Packaged Terminal Air Conditioner Wall Sleeve Installation

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

T-Extender E-Extender

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Transcription:

Talk-A-Phone Co. Model WEBS-MT/R OP5 Emergency Phone Tower Mount Architectural & Engineering Specification rev. 10/28/2011 1 General Description 2 Construction 1.1 The unit shall be a highly vandal-resistant free-standing steel emergency phone tower mount, model WEBS-MT/R OP5, no substitutions, with built-in combination LED Blue Light, illuminated faceplate, an integrated color PTZ dome camera mounted overhead on the extension arm and Wide-Area Emergency Broadcast System (WEBS) capability. The tower shall house an ADA-compliant, communication device manufactured by Talk-A-Phone Co. 1.2 The LED blue light shall be continuously lit and shall flash for the duration of a call when emergency button is pressed on the communication device. The communication device shall be capable of activating optional peripheral devices (i.e. activating a preset on a PTZ dome camera). 1.3 The PTZ dome camera shall be a SpeedDome Ultra 8 or equivalent. Specifications shall be available separately (contact Talk-A-Phone for more information). 2.1 The unit shall be constructed of 0.25" thick steel and shall weigh approximately 485 lbs. 2.2 The unit shall measure 12.8" W x 11.0" D x 124.0" H with a 2" radius on each corner. Including the extension arm, the tower shall be 12.8" W x 20.0" D x 162.0" H. 2.3 High-gloss, multi-layer, corrosion-inhibitive system with resistance to UV-fade and graffiti protection to withstand prolonged exposure to harsh environments. 2.4 An internal base plate shall be fully welded within the tower 2" above the tower base. The base plate shall be fabricated of 0.75" A-36 structural steel. There shall be a 4" diameter center hole for wiring access and four 1" diameter holes for anchor bolt clearance. 2.5 Tower shall have a wiring and anchor bolt access opening measuring 26.0" H x 6.6" W, located 8.0" above the base of the tower. The opening shall have a flush cover plate with a wall thickness of 0.25", held in place by eight 0.25-20 countersunk, tamper-resistant spanner screws. 2.6 An opening shall be cut in the face of the column for mounting any flushmounting, 400-Series or 500-Series emergency phone models. The lower edge of the opening shall slope down 30º from rear to front, making the edge difficult to use as a shelf yet convenient as a writing surface. 2.7 Speaker grilles shall be cut out of each side to allow for internally concealed horn speakers.

3 Lighting 2.8 A louvered panel shall be installed above or beneath each speaker grille to protect against condensation. 2.9 Tower shall have a hinged door with lock and handle to allow for secure access to a local paging microphone. 2.10 The word "EMERGENCY" shall be emblazoned on all four sides in reflective white letters with wide-angle visibility (custom lettering, sizes and colors available). Each letter shall be 3.25 in height. 2.11 WEBS Tower shall have a secondary opening with removable perforated aluminum plates for mounting wireless or other devices. 3.1 Atop the tower shall be a Blue Light. 3.1.1The Blue Light shall illuminate the area with a luminosity of 209 lumens peak. It would reach 70% of initial lumens after 50,000 hours of operation. It shall be lit at all times. 3.1.2The Blue Light shall flash 78 times per minute when the emergency phone is activated and continue flashing until the call has been completed. 3.1.3The polycarbonate refractor/housing shall have a prismatic pattern to increase visibility at greater distances. 4 Electrical 3.2 The tower shall have a concealed ultra-bright LED panel light to illuminate the emergency phone faceplate at all times. LED panel light shall have a lifetime of 100,000 hours. 4.1 Emergency Phone 4.1.1The ETP-400 Series emergency phone communication device shall require no external power. It shall be powered by the phone line, PBX extension, or a wireless communication interface. 4.1.2 The VOIP-500 Series emergency phone communication device shall operate on Power over Ethernet (PoE, 802.11af), a 12VDC power supply, or 24VDC/AC power supply. 4.2 Wide-Area Emergency Broadcast System (WEBS) 4.2.1The WEBS paging amplifier shall operate on standard 120VAC power. 4.2.2Analog WEBS wiring should be under 5,700 ft. on communicationsgrade (24AWG or better) twisted and shielded pairs. Only the paging

4.3 Lighting 5 Communications controller end (source side) should be grounded. In order to avoid noise on the line, it is recommended that the WEBS cable not be run in the same conduit as digital or power lines. However, if a location is already running CCTV in the same conduit as our phone line to the emergency phone, and experiencing no problems, the WEBS cable can be run in the same conduit as well. All national, state and local codes must be observed. 4.2.3IP-based WEBS shall use Cat 5e or greater wiring. 4.3.1The Blue Light shall operate on standard 120VAC power. 4.3.2The LED panel light shall operate on universal voltage: 12-24VDC/ 24-120VAC 4.4 The PTZ dome camera shall be powered by 18-30VAC, 50/60 Hz Class 2 LPS (see camera specifications). 4.5 All lamps and fixtures shall be UL/C.S.A listed. All electrical components shall be hard wired and concealed within the tower. All wiring and electrical fixtures comply with the standards of the National Electrical Code, UL and C.S.A. 5.1 Emergency Phone 5.1.1Tower shall accept any ETP-400 Series or VOIP-500 Series flush mounting emergency phone. 5.2 Wide-Area Emergency Broadcast System (WEBS) 5.2.1WEBS Tower shall accommodate either a connection to an analog paging controller (Model WEBS-ZPS) or a communications module (Model WEBS-CM-2 or VOIP-500 Series emergency phones). 5.2.1.1 WEBS Tower shall include one 130-Watt RMS amplifier to accommodate an analog connection to model WEBS- ZPS Zone Paging System. 5.2.1.2 WEBS Tower shall include one 130-Watt RMS amplifier to accommodate audio line-level connection to Model WEBS-CM-2 Communications Module that allows for IP-based paging in WEBS-enabled mounts (Models WEBS-MT/R, WEBS- PM, WEBS-WM). The WEBS-CM-2 shall be housed inside of the WEBS Tower. 5.2.1.3 WEBS paging stations shall have a dedicated headend paging controller. Analog-based WEBS systems shall have a maximum of 99 units. IP-based WEBS systems shall have a virtually unlimited number of units (i.e. maximum number is dependent on network topology).

5.2.2WEBS Tower shall include four 40-Watt, 8 ohms, concealed speakers for use with the Wide-Area Emergency Broadcast System (WEBS). One speaker shall be mounted behind a grille on each side of the tower. There shall be separate volume controls for each individual speaker. 5.2.3WEBS Tower shall include a local paging microphone for local tower broadcast and mustering. 5.2.4All units can be paged individually, in user defined groups, and as an all-call. 5.2.5WEBS Tower audio output shall be 123dB at one meter. 6 Mounting 7 Options 6.1 The tower shall include 24-inch J-bolts for mounting into a 24" x 24" concrete foundation, depth to vary according to local regulations and other site-specific considerations. J-bolts shall protrude approximately 5 inches from surface of foundation. 6.2 An optional mounting kit shall be available for mounting into above ground locations such as parking decks, where access to concrete base is available from both above and below. 6.3 The extension arm shall mount to the top back of the tower by fitting carriage bolts through pre-drilled holes in the tower. 7.1 Communications 7.1.1Emergency Phone 7.2 Integrated CCTV 7.1.1.1 Emergency Phone communication device shall accept fiber optic line instead of standard copper wire. ETP-400 Series or VOIP-500 Series flush mounting emergency phone and their respective fiber interface shall be required. 7.1.1.2 Cellular Interface shall be available when phone line is not available for the 400-Series emergency phone. 7.1.1.2.1 Transmission shall be CDMA 800 or PCS 1900, model ETP-CI/CDMA. 7.1.1.2.2 Transmission shall be 850/1900Mhz GSM, model ETP-CI/GSM 7.1.1.2.3 Transmission shall be CDMA for Verizon Wireless, model ETP-CI/CDMA-V

7.2.1 Model WEBS-MT/R OP2 shall include a mounting shelf above the emergency phone for mounting of an integrated fixed CCTV camera, supplied by others. A 2.81" diameter camera opening shall be located at a 56.24" height, with a clear polycarbonate impact-resistant cover protecting the CCTV camera. 7.2.2 Model WEBS-MT/R OP3 shall include an integrated fixed CCTV camera mounted above the emergency phone on a shelf at a 56.24" height. The CCTV camera shall be protected with a clear polycarbonate impact-resistant cover behind a 2.81" diameter camera opening. For full specifications of the CCTV camera, contact Talk-A-Phone Co. 7.2.3 Model WEBS-MT/R OP4 shall include a metal arm mounted to and extending 60" over the top of the tower for mounting of a PTZ dome camera, supplied by others. The LED blue light shall mount to the top of the arm. The LED blue light shall not be enclosed in a secondary polycarbonate enclosure. A PTZ dome camera shall mount underneath the arm on a 1.5" NPT. 8 Warranty 9 Manufacturer 8.1 WEBS Tower shall be warrantied against any defects in material and workmanship, under normal use, for a period of five years from date of installation. In the event system is found by manufacturer to be defective within the warranty period, manufacturer shall repair and/or replace any defective parts, provided the equipment is returned to manufacturer. 9.1 The Manufacturer shall be Talk-A-Phone Co. (773) 539-1100, 7530 N. Natchez Ave, Niles, Illinois 60714-3804, www.talkaphone.com. THERE ARE NO EQUIVALENTS.