PNEUMATIC CONTROLS Selection and Description



Similar documents
PNEUMATIC CONTROLS Dual Duct Sequence Descriptions

General Information... 2

Powers Controls TH 192 S Single Temperature Room Thermostat

GENERAL PRODUCT OVERVIEW

RC 195 Multiple Input Receiver-Controller

T-4000 Series Room Thermostat Adjusting Instructions*

Installation Manual. TITUS I, II, and IIA Pneumatic Controls Installation, Operation, and Maintenance Manual. (See Figure 3) (Label, See Figure 3)

POWERS CONTROL RC 195 Single Input Receiver-Controller

Installation/ Operation Maintenance

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Model 43AP Pneumatic Controller, Style B

KRUEGER Single-Duct and Retro Fit Terminal Units

Digi-Motor Installation Guide

Why and How we Use Capacity Control

T-4000 Series Pneumatic Room Thermostats

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Fundamentals of HVAC Control Systems

SIMPLIFIED VALVE CIRCUIT GUIDE

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

PIEZOMETER AIRFLOW MEASURING RING

PRODUCT PROFILE FEATURES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

SIMPLIFIED VALVE CIRCUIT GUIDE

POWERS Controls No. 4 Pneumatic Damper Actuator

Centrifugal Fans and Pumps are sized to meet the maximum

ENHANCED LABORATORY HVAC SYSTEM

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

AABC Specifications for Testing and Balancing HVAC Systems

E2 Series Electric Furnaces

AIR - PNEUMATIC, AIR CONDITIONING, PRESSURIZATION

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

vav retrofit terminals

Fossil fuel heating equipment

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Demand Based Static Pressure Reset Control for Laboratories

SLIM LINE FUME HOOD MONITOR

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Signature and ISX CM870 Electronics

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

Variable Air Volume - VAV


Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Basic Technology Series

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

NC-12 Modbus Application

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

HERZ-Thermal Actuators

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

System 8. ü ( System 8

SELECTION, APPLICATION AND MAINTENANCE

Operational Overview and Controls Guide

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Electro-Pneumatic Bus Door Control Mechanism

LABORATORY FUME HOOD CONTROL SYSTEMS

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Impact of Control System Technologies on Industrial Energy Savings

Product/Technical Bulletin

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Lesson 36 Selection Of Air Conditioning Systems

Signature and ISX CM870 Fuel System

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

HVAC Processes. Lecture 7

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

A/C-HEATER SYSTEM - AUTOMATIC

Printing and Publishing Energy Savings Guide

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

5.6 Technical Specification: Premium Efficiency Electric Air Conditioning Equipment

Air Conditioning Sign-Off Sheet

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

Chapter 3.5: Fans and Blowers

Page 1. Description

REGULATORS 175/153 Series

Bring the fresh in. Dedicated Outside Air Systems

T and T Single Input Receiver-Controllers Installation and Calibration

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

Example. Fluid Power. Circuits

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

Element D Services Heating, Ventilating, and Air Conditioning

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

ANSI/AHRI Standard 880 (I-P) with Addendum Standard for Performance Rating of Air Terminals

Transcription:

PNEUMATIC CONTROLS Selection and Description Carnes pneumatic controlled throttling units are suitable for a standard 20 psi control system and may be supplied with pressure dependent or pressure independent control types. Pressure Dependent Control: A pneumatic signal is sent directly from the thermostat. A reverse acting thermostat may be used with a normally open or closed damper. With a decrease in room temperature, an increased thermostat output signal will move the damper actuator to position the damper at a reduced air flow. A direct acting thermostat may also be used with a normally open or normally closed damper. With a decrease in room temperature, a decreased thermostat output signal will move the damper actuator to position the damper at a reduced air flow. Units with pressure dependent controls may be ordered with optional adjustable mechanical stops for maximum and minimum air flow settings. Pressure dependent air flow settings are field set according to the job system conditions. Units with pressure dependent controls may be ordered without mechanical stops for maximum and minimum air flow settings. The damper may be field adjusted to set the minimum air flow or limit the maximum air flow by loosening the linkage and offsetting the rotation of the damper position at one of the flow conditions. Pressure Independent Control: By use of a reset volume controller in conjunction with a room thermostat, the throttling unit will maintain an air flow rate in response to the thermostat, independent of duct static pressure variations between the minimum catalogued static pressure value and 6.0 w.g. Minimum and maximum air flow settings are field calibrated for system balancing at the job site. Pressure independent control can be used with reheat units where a minimum air flow must be maintained. As a standard, the reset volume controller provided by Carnes is offered with a normally open or a normally closed damper for use with a direct acting thermostat, or with a normally closed or normally open control damper for use with a reverse acting thermostat. Many combinations of damper actions and pressure independent controls are available for controlling dual duct terminal units to provide mixing, deadband or constant volume sequencing. Units with pressure independent air flow controls may be ordered with a zero (full shut off) minimum setting. For proper controller operation, a minimum air flow setting other than zero (full shut off) should be selected at an inlet velocity of at least 365 fpm. PRESSURE DEPENDENT SINGLE DUCT UNITS DUAL FAN DUCT UNITS RETROFIT CTRL OPT. CONTROL OPTION DESCRIPTION AVC AVW AVE ABB ABW ADC AS AC ARR CA PNEUMATIC ACTUATOR BY CARNES WITH X X X X X X* X MECHANICAL MAX./MIN.STOPS CM PNEUMATIC ACTUATOR BY CARNES X X X X X X* X * = ADCC Only PRESSURE INDEPENDENT CE CX PNEUMATIC ACTUATOR AND RESET CONTROLLER BY CARNES PNEUMATIC ACTUATOR AND MULTI-FUNCTION RESET CONTROLLER BY CARNES X X X X X X X X X X X X X X X X X X www.carnes.com B-269

PNEUMATIC DAMPER ACTUATOR The Carnes pneumatic damper actuator is composed of black nylon 6/6 reinforced with 33 percent glass fiber. The actuator has a 2-1/2 stroke and is equipped with a fitting for 1/4 O. D. control tubing. The spring range is 8 to 13. RESET VOLUME CONTROLLERS The reset volume controllers are designed to operate pneumatic actuators to control air volume flow through terminal units in HVAC systems. These controller are submaster devices that sense terminal unit velocity from an inlet flow differential pressure sensor. Velocity set points are reset between adjustable minimum and maximum CFM settings by a room thermostat. These controllers will maintain the air volume required by the zone regardless of inlet static pressure change. Thus, the terminal unit is system pressure independent. The direct acting reset controller (beige) is used for normally open terminal unit dampers. The reverse acting controller (gray) is used for normally closed terminal unit dampers. Reset Pressure Range: Direct Acting 8 to 13 psig (nominal) Reverse Acting 3 to 8 psig (nominal) Differential Pressure Range: 0.0 to 1.35 W. C. Main Air Pressure: 15 to 30 psig Air Consumption: 0.4 SCFH (12 SCIM) @ 20 psig Maximum Static Pressure: 12 W. C. Air Connections: High/Low Pressure Taps, fittings for 3/8 O. D. plastic tubing. Main, Branch, Thermostat, fittings for 1/4 O. D. plastic tubing. Ambient Operating Temperature: 40 F to 120 F Material: ABS Plastic Weight: 7.5 ounces B-270 www.carnes.com

MULTI-FUNCTION RESET VOLUME CONTROLLER The multi-function reset volume controllers are designed to operate pneumatic actuators to control air volume flow through terminal units in HVAC systems. This controller can be used with either direct acting or reverse acting thermostats and for normally open or normally closed terminal unit dampers. These controllers are submaster devices that sense terminal unit velocity from an inlet flow sensor. Velocity set points are reset between adjustable minimum and maximum cfm settings by a room thermostat. These controllers will maintain the air volume required by the zone regardless of inlet static pressure change. Thus, the terminal unit is system pressure independent. These controllers have a factory set reset start point and a reset span which can be field adjusted to remain constant no matter what maximum and minimum air flow limits have been set. PNEUMATIC/ELECTRIC (P/E) SWITCH A single stage P/E switch is used to energize or de-energize an electrical device in response to a pneumatic signal. P/E switches are adjustable so that the switching point can be calibrated to a specific input pressure. These switches can be mounted in any position regardless of orientation. REVERSING RELAY The reversing relay is designed to reverse a proportional signal from a controlling device. These relays decrease the branch line pressure as the input pressure is increased. A bias adjustment is provided to advance or retard the output pressure if required. Reversing relays are typically used to change the thermostat signal from reverse acting to direct acting or direct acting to reverse acting. These relays are not position sensitive and are suitable for inline mounting. www.carnes.com B-271

GRADUAL SWITCH The gradual switch is designed to allow for a manual setting of a desired pneumatic pressure output up to main air pressure. A gradual switch is used where the application requires remote positioning of a final control device or remote control point adjustment of a pressure signal. Gradual switches are typically used in dual-minimum and open-close-open sequences. DIVERTING RELAY Diverting relays are single pole, double throw devices that are used to divert one pneumatic signal to either of two branch circuits. These relays can be used to select one or two input signals and transmit it to another control device. In some cases, diverting relays are used to feed or exhaust a particular pneumatic circuit. These relays are not position sensitive and are suitable for in-line mounting. PRESSURE SELECTOR RELAY (High or Low) Pressure selector relays are intended for use in pneumatic control systems where the final control device must be controlled from two different signals. The relay compares the two proportional signals and transmits either the higher or lower signal to another control device. These relays are not position sensitive and are suitable for in-line mounting. B-272 www.carnes.com

PNEUMATIC CONTROLS Component Legend Reset Volume Controller (Air Consumption = 15 SCIM @ 20 psi) BEIGE CONTROLLER Carnes Part # 999-2825 (For Use with Normally Open Dampers) GRAY CONTROLLER - Part # 999-2826 (For Use with Normally Closed Dampers) Reset Volume Controller (Air Consumption = 30 SCIM @ 20 psi) MULTI FUNCTION CONTROLLER Carnes Part # 999-2827 (May be used with both direct and reverse acting Inputs) (May also be used with normally open and closed dampers) AIR FLOW SWITCH DAMPER ACTUATOR NO = Normally Open Damper NC = Normally Closed Damper FAN Fan Blower and Motor Assembly REVERSING RELAY (Air Consumption = 15 SCIM @ 20 psi) P/E Pneumatic/Electric Switch (Field Adjusted) THERMOSTAT INLET SENSOR Differential Pressure (Dots Indicate HIGH Pressure Side) YELLOW = LOW SIGNAL (Static) GREEN = HIGH SIGNAL (Total) FAN SPEED DIAL DISCONNECT SWITCH Line Voltage Disconnect INLINE RESTRICTOR CAPACITOR Fan Motor Start Capacitor MAIN CONTROL AIR SUPPLY Range 18-30 psig HOT WATER VALVE www.carnes.com B-273