INSTALLATION MANUAL. SAILOR 5080 AC Power Supply



Similar documents
Modular I/O System Analog and Digital Interface Modules

Emergency lighting units EM powerled

Photovoltaic Solar Energy Unit EESFB

HERZ-Thermal Actuators

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

HM-W536 Install Guide

INSTALLATION MANUAL. AC/DC Power Supply

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Inverter / Charger Installation General Operations and AC and DC Connections

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Product and functional description

Three-phase monitoring relay CM-PFE

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Actuator-Sensor-Interface

instabus KNX / EIB System System E F G H

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Installation, operation and maintenance manual TX 35A

Inductive Proximity Sensors

User Manual for CH-PFC76810

User Guide. 4 wire Earth Resistance Tester Model GRT300

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

ACS-30-EU-EMDR-10-MOD

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

User s Manual Before using the inverter, you need to read and save the safety instructions.

StructureScan HD Module. Installation Guide ENGLISH

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Rutland 913 Windcharger Fault Finding Guide

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Contractors Guide Central Inverter System Installation

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Universal Vehicle Power Supply 9007AX01. Installation Instructions

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

6. Diagnostics for A/C System Malfunction

MCR1900 Media Converter 19-Slot Chassis

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

DALI RC BASIC SO. Control unit Operating instructions

Safety technique. Emergency stop module BO 5988 safemaster

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

R.C.C.B. s two-pole LEXIC

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

4KVA/5KVA Parallel Installation Guide

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

IMPORTANT SAFETY INSTRUCTIONS

AutoRanging Digital MultiMeter

ST Series POWER SUPPLIES USER INSTRUCTIONS

Manual. Solar Fountain Mobile Phone Charger

Electronic overload relay EF65, EF96 and EF146

Cable Plug acc. to DIN EN , Form A

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

ICON Server box installation manual Rev. 1.1

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Manual. Simrad StructureScan LSS-1 Sonar Module. English

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Floodlight Range Installation Guide


7-SEGMENT DIGITAL CLOCK

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

W150: Miniature photoelectric switch series with completely integrated electronics

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

E-WERK Bike-mobile hub dynamo powered supply unit for electronic devices. Instruction manual. Please study carefully before using E-WERK!

I STAR COMPUTER CO., LTD

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Technical Update TAA.TU Rev. 1

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

PowerGem Pro Uninterruptible Power Supply

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Instruction manual. Electrobloc EBL 100-2

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Speed Control Relays SX2

DCS Input/Output Relay Card Series

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

RS - SPM. Serial parallel translator module

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Quick Connect. quick - simple - efficient.

Thyristor-controlled power supplies and battery chargers

Electronic overload relay EF19 and EF45

Bimetallic Overload Relay Specifications

Group R-70 to R-75: only Vauxhall. Subject. Sound Package. Vehicles. Omega-B (only Saloon) General

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

FW-X240 AUTO TRANSFORMER Installation Manual

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Current Monitoring Kit QUICK START GUIDE

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Product Information Sheet UH28CS-12kV Hi Pot Tester

Transcription:

INSTALLATION MANUAL SAILOR 5080 AC Power Supply

Contents Introduction... 3 General description... 3 Technical data... 3 Installation... 4 Outline and dimension... 4 Installation wiring... 5 Block diagram switch mode Power Supply Unit... 6 AC supply voltage setting... 7 AC Alarm interface... 8 Schematic diagram... 9 Power Supply Unit... 9 AC Alarm Interface... 10 Internal connection... 11 Disclaimer Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed by Thrane & Thrane. The information in this manual is provided for information purposes only, is subject to change without notice, may contain errors or inaccuracies, and represents no commitment whatsoever by Thrane & Thrane. This agreement is governed by the laws of Denmark. Manuals issued by Thrane & Thrane are periodically revised and updated. Anyone relying on this information should satisfy himself/herself as to the most current version. Providers with access to Thrane & Thrane s Extranet may obtain current copies of manuals at: http:// extranet.thrane.com. Thrane & Thrane is not responsible for the content or accuracy of any translations or reproductions, in whole or in part, of this manual from any other source. 0748 1

2 0748

Introduction General description The 5080 AC Power Supply is designed as a stand alone AC Power Supply, with provision for automatic switch over to backup DC supply/battery. The AC Power Supply is designed with three fused and fully separated output lines to ensure independent supply for connected equipment. Additionally a galvanically isolated AC alarm output is provided. Technical data AC input voltages: 110, 120, 220/230, 240V AC +/- 10% AC input frequency: 50/60 Hz +/- 6% DC output voltage: DC output current: 28V 58 A max. AC Mains Alarm output: Make/break relay contacts 0.5 A 32V. Alarm in case of AC supply failure. Protection: The AC Power Supply is current limited and protected against polarity reversal, short circuit, overvoltage and overtemperature. Operating temperature: - 20 to + 55 C. Dimensions: Weight: H: 638 mm, D: 126 mm, W: 440 mm. Approx. 15.5 kg. Compass safe distance: Standard: 4.0 m. Steering: 2.5 m. 0748 3

Installation Outline and dimension 125.5 440 8 x ø10 638 41.5 185 185 185 1) 1) 3) 2) 395.6 418 Note: 1) Space for airflow: min. 200 mm. 2) Space for cable and airflow: min. 25 mm. 3) Space for service access: min 1000 mm. All dimensions are in mm. TT99-125810 Weight: 15.5 kg 4 0748

Installation wiring AC Alarm interface L N AC in - + - + - + - + 63A 63A 10A 10A Backup DCout supply input MF/HF Tx Spare out Spare out TT99-126717 0748 5

Block diagram switch mode Power Supply Unit 4-0-34725 6 0748

AC supply voltage setting Before connecting the AC Power Supply to the AC mains, be sure that the voltage selector switch is set to the correct voltage and that the fuse rating corresponds to the setting used. The voltage selector switch is located on the AC Power Supply assembly under the front cover. The selected voltage is indicated by an arrow in the outer ring (refer to next page). The equipment is normally dispatched with the selector set to 220V. To select a different voltage insert a screwdriver in the slot and turn the switch to the correct setting. Note: As two SMPS units are operated in parallel input voltage selection must be done on both units. Setting Voltage range 110 99-132 V 220 198-264 V Caution: Incorrect setting of the mains voltage selector may damage the AC Power Supply Assemblies The AC mains fuse holder is an integral part of the AC terminal block which is located to the left under the front cover. The fuse is accessed by pulling out the black handle. The correct rating for each voltage setting is as follows Setting Fuse rating 110 10 A Slow 220 6.3 A Slow Fuses are cartridge type measuring 5 x 20 mm. The AC supply leads are connected as indicated to the terminal block. Screened power L N Live Neutral Protective earth supply cable may be used as required by some administrations. The cable is fastened and the screen connected by a cable clamp on the main chassis below the terminal block. Recommended cable type: 3 x 1.5 mm2 0748 7

AC Alarm interface The AC Alarm Interface is located to the right under the front cover. It contains an terminal strip marked AC ALR 0 and AC ALR 1. A cable for a alarm device is to be connected as indicated in the table below. Terminal Designation Description 1 Not connected 2 AC ALR 0 3 AC ALR 1 Galvanically isolated AC alarm output. Relay contacts, max. 0.5 A 32V. Alarm condition: AC supply missing (terminals 2 and 3 are closed). 4 Not connected 8 0748

Schematic diagram Power Supply Unit 9

AC Alarm Interface 10

Internal connection 24 core charger option cable AC SMPS 62-125797 Stabilized current limited and auto switch over AC alarm interface Fuse terminal 24 core charger option cable Alarm relay out AC SMPS 62-125797 Stabilized current limited and auto switch over Battery input filter 62-126363 Output filter 62-126319 Fuse terminal - + - + - + - + 63A 63A 10A 10A Backup DCsupply input DC out DC out DC out AC in TT99-127012 11

TT-98-126720-THR-A Issue: 0748 Thrane & Thrane A/S info@thrane.com www.thrane.com