MANUAL PLATELET COUNT

Similar documents
MANUAL WBC LAB OBJECTIVE

MANUAL PLATELET COUNT

Preparation of Blood Films

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 079 MOD: 1st Issue Page: 1 of 7

EDUCATIONAL COMMENTARY RED BLOOD CELLS AND WHITE BLOOD CELLS IN URINALYSIS

Cold Agglutination Titer detecting Cold Reacting Antibodies

Related topics: Application Note 27 Data Analysis of Tube Formation Assays.

GIEMSA STAIN PREANALYTICAL CONSIDERATIONS

ABORhCard. ABORhCard Package Insert ABO and Rh Blood Grouping Device

EXERCISE 5: ERYTHROCYTES SEDIMENTATION RATE - ESR, SED RATE

A Fishy Tale. Observing the Circulatory System of a Goldfish with a Compound Light Microscope

STAINING OF PBF AND INTERPRETATION OF NORMAL AND ABNORMAL RED CELL MORPHOLOGY

EXERCISE 3: SKIN PUNCTURE ON INFANTS

The Golden Rule of Specimen Collection: The Patient Test Result is Only as Good as the Sample We Get

BACTERIAL ENUMERATION

Care and Use of the Compound Microscope

HAEMATOLOGY LABORATORY

Microscope Lab Introduction to the Microscope Lab Activity

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

Hemoglobin Testing using the Data Management HemoCue Analyzer

STEMCELL Quality Control Kits

9.Pediatric Procedures

EXPERIMENT #1: MICROSCOPY

Protocol Micro Lab. K:\Microlab_protocols\Protocols_active\03 Instrument manuals\ml03_001_001 DGGE.doc. Preparation of gels

Factors Affecting Enzyme Activity

STEP-BY-STEP INSTRUCTIONS FOR INVESTIGATIONAL USE. Rapid HCV Antibody Test FOR ORAQUICK RAPID HCV ANTIBODY TEST

Collection Guidelines for Routine & Special Coagulation Testing

Contents. Introduction... A Note About Heatsinks... Precautions...

ENUMERATION OF MICROORGANISMS. To learn the different techniques used to count the number of microorganisms in a sample.

Exercise 9: Blood. Readings: Silverthorn 5 th ed, , ; 6 th ed, ,

UltraClean Soil DNA Isolation Kit

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

Urinalysis and Body Fluids CRg

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

1. Preparing thin and thick blood films with capillary or venous blood

Enumeration and Viability of Nucleated Cells from Bone Marrow, Cord Blood, and Mobilized Peripheral Blood

ISOLATION OF CAFFEINE FROM TEA

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Blood Plasma Sample Collection and Handling for Proteomics Analysis - A guide to obtain optimal plasma samples -

serology Agglutination Techniques and Blood Cell Identification

LABORATORY 2 Staining and processing of blood parasites Differential counts of leukocytes (giemsa stains)

Where is Mitosis Most Common in the Onion Root?

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

STANDARD OPERATING PROCEDURE

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

Exercise 2. The Compound Light Microscope

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Free SO 2. by Aeration-Oxidation. A n o t h e r M o r e M a n u a l!

Contents. POCT Program Massachusetts General Hospital - Pathology Service 55 Fruit Street, Boston, MA 02114

Lab 02: Blood Cytology (20 points)

ABO-Rh Blood Typing With Synthetic Blood

Urinalysis and Body Fluids CRg. Synovial Fluid. Synovial Fluid. Unit 4. Composition and formation. Functions. Reasons for analysis.

MODIFIED TRICHROME STAIN

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

Reasons for reissue are in Section 6, REVISION SUMMARY.

Chem 131A: Absorbance of Riboflavin

Xpert TM Animal Tissue Culture Teaching Kit

BD Trucount Tubes IVD

Determination of a Chemical Formula

VENOUS BLOOD COLLECTION

A Self-Study Packet for The Johns Hopkins Hospital Point-of-Care Testing Program copyright 2011 Johns Hopkins Hospital All rights reserved

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

Plant Genomic DNA Extraction using CTAB

ArtisanLink Staining System is an automated special stains slide

Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM 1.073

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

BLOOD CULTURE COLLECTION GUIDELINES FOR PHLEBOTOMISTS (WITHIN REGION 6)

Lab 4: Osmosis and Diffusion

Microbiology BIOL 275 DILUTIONS

LABORATORY 3: Microscopic Urinalysis

2D gel Protocol. 2. Determining Protein Concentration of cell lysates

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

SEPARATION OF A MIXTURE OF SUBSTANCES LAB

Vitamin C Content of Fruit Juice

<788> PARTICULATE MATTER IN INJECTIONS

DETECTION OF BACTERIAL MOTILITY. To demonstrate bacterial motility by microscopic and macroscopic techniques.

ABORhCard Applications and Performance Studies White Paper

EXTRACTION OF DNA FROM CALF THYMUS CELLS Revised 2/1/96 Introduction

Hematology Sequence. Blood Labs ORIENTATION OBJECTIVES. c. Microscopic Exam of a Peripheral Blood Smear (several parts)

Measuring Cell Viability/Cytotoxicity: Cell Counting Kit-F

DNA SPOOLING 1 ISOLATION OF DNA FROM ONION

Operator Quick Guide EC SENSOR

PHYSICAL SEPARATION TECHNIQUES. Introduction

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

ABO-Rh Blood Typing Using Neo/BLOOD

Quaternary Ammonium Compounds DOC

For in vitro preparation of human mononuclear cells from peripheral blood, bone marrow, and umbilical cord blood. Not for in vitro diagnostic use.

LABORATORY PROCEDURE MANUAL

How to Verify Performance Specifications

HEMOCUE Procedure 1.0. S. Terence Dunn, PhD. 23-Apr : Apr-2016

V-500-PRE. 500mm F/8.0 Telephoto Lens INSTRUCTION MANUAL

Standard Operating Procedure for Cleaning Nylon Filters Used for the Collection of PM 2. 5 Material

LAB 11 PLASMID DNA MINIPREP

Aptima Specimen Transfer Kit

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

ab83369 Alkaline Phosphatase Assay kit (Colorimetric)

Transcription:

MANUAL PLATELET COUNT LAB OBJECTIVE The student will be able to perform, within K20% accuracy as compared to the automated result, five manual platelet counts using the Unopette system. and the light microscope. PRINCIPLE Free-flowing capillary or well-mixed antigoagulated venous blood is added to a diluent at a specific volume in the Unopette reservoir. The diluent lyses the erythrocytes but preserves leukocytes and platelets. The diluted blood is added to the hemacytometer chamber. Cells are allowed to settle for 10 minutes before leukocytes and platelets are counted. (Always refer to the manufacturer s instructions for the procedure.) SPECIMEN EDTA-anticoagulated blood or capillary blood is preferred. REAGENTS, SUPPLIES AND EQUIPMENT Unopette reservoir no. 5854/5855 (1.98 ml of diluent) Ammonium oxalate 11.45 g Sorensen s phosphate buffer 1.0 g Thimerosal 0.1 g Purified water qs to 1000 ml Unopette capillary pipet, 20-µL capacity Hemacytometer and coverslip Microscope Lint-free wipe Alcohol pads Hand counter Petri dish with moist filter paper QUALITY CONTROL A normal control specimen should be counted. Perform estimated platelet count from Wright-stained peripheral smear to confirm result. NOTE: For this lab exercise, QC will be precision check with automated platelet count. Page 1

PROCEDURE 1. Using the protective shield on the capillary pipette, puncture diaphragm of Unopette reservoir and add sample using a 20 µl capillary pipette provided with the Unopette system. 2. Remove shield from pipette assembly by twisting. 3. Holding pipette almost horizontally, touch tip of pipet to blood. Pipet will fill by capillary action. Filling will cease automatically when the blood reaches the end of the capillary bore in the neck of the pipet. 4. Wipe the outside of the capillary pipet to remove excess blood that would interfere with the dilution factor. 5. Squeeze reservoir slightly to force out some air while simultaneously maintaining pressure on reservoir. 6. Cover opening of overflow chamber of pipet with index finger and seat pipet securely in reservoir neck. 7. Release pressure on reservoir. Then remove finger from pipet opening. At this time negative pressure will draw blood into reservoir. 8. Squeeze reservoir gently two or three times to rinse capillary bore forcing diluent up int, but not out of, overflow chamber, releasing pressure each time to return mixture to reservoir. 9. Place index finger over upper opening and gently invert several times to thoroughly mix blood with diuent. 10. Let mixture stand 10 minutes before charging the hemacytometer. 11. Meticulously clean the hemacytometer with alcohol or other cleaning solution. This is important because dust particles and other debris can be mistaken for platelets especially on a light microscope. Allow to dry completely before charging with diluted specimen. 12. To charge the hemacytometer, convert to dropper assembly by withdrawing pipet from reservoir and reseating securely in reverse position. 13. Invert reservoir and discard the first 3 or 4 drops of mixture. 14. Carefully charge hemacytometer with diluted blood by gently squeezing sides of reservoir to expel contents until chamber is properly filled. 15. Place hemacytometer in moist Petri dish for 10 minutes to allow platelets to settle. (Moistened filter paper retains evaporation of diluted specimen while standing.) 16. Mount the hemacytometer on the microscope and lower its condenser. Page 2

17. Procedure for counting platelets: a. Under 40x magnification, scan to ensure even distribution. Platelets are counted in all twenty-five small squares within the large center square. b. Count cells starting in the upper left of the large middle square. Continue counting to the right hand square, drop down to the next row; continue counting in this fashion until the total area in that middle square (all 25 squares) have been counted. c. Count all cells that touch any of the upper and left lines, do not count any cell that touches a lower or right line. Neubauer Hemocytometer, counting area. 18. Multiply the average number of platelets counted on both sides of the chamber by 1000 to get the total platelet count/mm 3. Multiply this number by a factor of 10 3 to have the platelet count in SI units or 10 3 /µl. This step of multiplying by 1000 simplifies multiplication of dilution factor (100) and depth (10) which is equal to 1000. Page 3

Example An average of 230 platelets were enumerated on both sides of the hemacytometer using the Unopette system for platelet determinations. Platelets/mm 3 = 230 x 1000 = 230,000/mm 3 = 230 x 10 3 /µl Another way of calculating the result follows: dilution = 100 # squares counted = 1 volume of one square = 0.1 :L RECORDING YOUR RESULTS Use the form provided to report your results. Precision: Determine if the two counts are in close enough agreement. Use the following procedure: 1. Obtain the difference (C) between the Side A and Side B of the hemacytometer. 2. Calculate 2 S.D. as follows: 3. If C is less than 2 S.D., the results are acceptable. If greater, the counts must be repeated. Example: A = 430 B = 470 C = 40 C (40) is less than 2 S.D. (60) and therefore is acceptable. Accuracy: Determine if the two counts within 20% of the automated count Example: Automated count = 230 x 10 9 /L. 230 x 10 9 /L - 20% = 184 x 10 9 /L Acceptable range is 184-276 x 10 9 /L 230 x 10 9 /L + 20% =276 x 10 9 /L Manual count = 200 x 10 9 /L so manual count is acceptable. REPORTING RESULTS Normal Values 130-400 x 10 3 /µl Page 4

NOTES 1. Diluent and blood should be properly mixed before filling the hemactyometer. 2. The hemacytometer must be properly filled to avoid erroneous results in manual cell counting. 3. If the chamber is overfilled, as indicated by the presence of excess fluid in the moat of hemacytometer, clean hemacytometer and recharge chamber. As with all manual counts, the diluent sample must be thoroughly mixed before charging the hemacytometer, which must be properly filled. 4. A highly elevated platelet count may make accurate counting difficult. In either instance, a secondary dilution should be made. When calculating the total count, adjust the formula to allow for secondary dilution. 5. Platelets appear as dense, dark bodies and can be round, oval, or rodlike, sometimes showing dendritic processes (hairy projections). Their internal granular structure and pearlescent sheen allow the platelets to be distinguished from debris, which is often refractile. RBC s appear as ghost cells. Use caution when RBCs have inclusions present, so as not to confuse the inclusion with platelets. 6. If platelet clumping is observed, redilute the count. If clumping is still present, obtain a fresh specimen. An even distribution of platelets through the counting area is critical. Because of the adhesive quality of platelets, fingerstick specimens are least desirable. Platelet clumping can be caused by poor venipuncture technique or inadequate mixing of the specimen after collection. It is especially difficult to obtain accurate platelet counts from heelstick punctures on babies. The phlebotomist must use proper technique and obtain the blood quickly. 7. The platelet determination should be compared with a review of the blood film for confirmation of count and morphology. 8. EDTA is the anticoagulant of choice when performing platelet counts. The student should be aware of platelet satellitosis or platelet clumping when using this anticoagulant. Platelet satellitosis appears as neutrophils ringed with adhesive platelets. Obtain correct platelet counts by collecting a fresh specimen with sodium citrate as the anticoagulant. When sodium citrate is used as an anticoagulant, make the correction for the dilution by multiplying by 1.1 9. It is preferable to use a phase contrast microscope as opposed to a light microscope when counting platelets as it allows for better differentiation from debris and RBC inclusions. 10. A variety of technical errors can produce incorrect results. These include the age of the specimen, clumping of platelets, debris in the diluting fluid, platelet adherence to glass, and incorrectly diluting the specimen. 11. Some common causes of increased platelets (thrombocytosis) are postsplenectomy, polycythemia vera, chronic myelogenous leukemia. 12. Some common causes of decreased platelets (thrombocytopenia) are aplastic anemia, idopathic thrombocytopenic purpura, acute leukemias. Page 5

REFERENCES Harmening., Denise, Clinical Hematology and Fundamentals of Hemostasis, 3 rd edition, pp. 593-599. Turgeon, Mary Louise, Clinical Hematology - Theories and Procedures, 3 rd edition, pp320-321. Page 6

Manual Platelet Report Form for Lab Exercise Student s name: Date: Unopette Lot #: Expiration Date: Patient ID Patient ID Side 1 Side 2 Side 1 Side 2 Total: Total: Total: Total: Average: Difference between results: Calculate 2 S.D.: Average: Difference between results: Calculate 2 S.D.: Is the difference less than 2 S.D.? Calculation of result: Is the difference less than 2 S.D.? Calculation of result: Manual platelet result: Automated result: (Obtain from instructor) Automated result range K20%: Is manual result within K20% of automated result? Manual platelet result: Automated result: (Obtain from instructor) Automated result range K20%: Is manual result within K20% of automated result? Page 7

STUDY QUESTIONS Name Date 1 pt 1. Why is it not desirable to use capillary blood for a platelet count? 2 pt 2. Define: A. Thrombocytopenia B. Thrombocytosis 3 pt 3. List 3 conditions for thrombocytopenia. A. B. C. 3 pt 4. List 3 conditions for thrombocytosis. A. B. C. 2 pt 5. Describe platelet satellitosis. 2 pt 6. What would you do to obtain an accurate platelet count when platelet satellitism is present? 2 pt 7. State the normal reference range for platelets. Page 8

2 pt 8. Describe the area of the hemacytometer that is used to count platelets. 2 pt 9. Calculate the following platelet count. Show your work. Side # 1 = 207 platelets Side # 2 = 195 platelets 5 pt 10. List 5 technical errors that can cause an erroneous platelet count. A. B. C. D. E. 2 pt 11. List 2 preanalytical errors that will affect the accuracy of a platelet count. (Preanalytical refers to the processes that occur prior to testing of the specimen such as phlebotomy.) A. B. 1 pt 12. What is the preferred microscope for counting manual platelet counts? Page 9