AMD-33 Air Measuring Station with VCD-33 Control Damper



Similar documents
AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

HVAC Control & Balancing Dampers Models VCD, MBD and RBD

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

FIRE DAMPER APPLICATION GUIDE

plenum slot diffusers

AIR CONDITIONING PRODUCTS COMPANY

DUCT SMOKE DETECTOR D4120

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes. Accurate airflow measurement for demanding applications

Dampers and Actuators Catalog

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

Demand Based Static Pressure Reset Control for Laboratories

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

CARNES COMPANY 448 S. Main St., P. O. Box , Verona, WI Phone: (608) Fax: (608) Depth (10 std.

AMCA Publication (Rev )

SUMMARY of PRODUCTS. HVAC Systems Control Airflow, Space, & Building Pressurization. Accurate airflow measurement for demanding applications

PRODUCT PROFILE FEATURES

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

CURTAIN TYPE FIRE DAMPERS

ROOF TOP MOUNTED Air Handler Specification

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Electromagnetic Flow Meter

CE6500 Energy Recovery Ventilator

Dual Maximum VAV Box Controls

MULTIZONE APPLICATION OF SOLUTION UNITS

Analogue + IVS Electronic Throttle Controls for CUMMINS Engines

SECTION MORTUARY REFRIGERATORS

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

Control and Distribution Boxes made of Stainless Steel Series 8150

For Multi-Parameter Meters see mvx

POWERS CONTROL RC 195 Single Input Receiver-Controller

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

POWERS Controls No. 4 Pneumatic Damper Actuator

Fan Performance By: Mark Stevens AMCA International Deputy Executive Director Technical Affairs

Fire and Smoke Dampers: Best Practice Design Tips. An AMCA International White Paper. July 2015

Basic Selection & Proper Application of Overhead Air Distribution Devices

Damper Selection and Sizing

Exhaust Calculation Booklet

Chapter 3.5: Fans and Blowers

Miami-Dade Qualified Drainable Blade Louvered Penthouse


SECTION BUILDING MANAGEMENT SYSTEM AND HVAC EQUIPMENT

The Unique Accelabar Flow Meter

Element D Services Heating, Ventilating, and Air Conditioning

Healthcare Solutions Room Pressure Monitors and Controls

vav retrofit terminals

security products metric sizes Redefine your comfort zone.

product application guide

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

VariTrane Duct Designer An in depth look...

PRESSURE REDUCING CONTROL VALVE

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

Air Side Economizers and Energy Recovery - Improvements and New Regulations. Richard Lord

Centrifugal Fans and Pumps are sized to meet the maximum

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Performance Rating of Room Fan- Coils

Electronic Flow Switches

COMMERCIAL CATALOG. Tab Document Name Part Number. 2 SUMMARY OF PRODUCTS Summary of Products

TorqPlus TM Electric Valve Actuators and Controls

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Section 5: Machine Overview

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Ventilation Solutions Kitchens. fantech

Automatic Door Selection Guide

GENERAL PRODUCT OVERVIEW

GEAROLOGY 4-1 WORMS AND WORM GEARS WORMS AND WORM GEARS

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION BLOWER COIL UNITS

Mechanical Rooftop Custom Capabilities

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Uni-Quick Duct System. Moveable. Uni-Quick. Duct System. DUST COLLECTION and MATERIAL HANDLING APPLICATIONS a McGill AirFlow product

CHILLED WATER DATA ROOM UNITS

AABC Specifications for Testing and Balancing HVAC Systems

Grilles & Diffusers Series LFP Incorporating

GUARDRAIL INNOVATION FLOWS FROM HERE

E-PDD Duct Smoke Detector Installation Sheet

HVAC air curtains. Type InduAir

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Cooking at the Speed of light!

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS

Help. Help Software Tutorial. Building a load sizing project with an ME Series Humidifier

Tube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

PIEZOMETER AIRFLOW MEASURING RING

Givare NC-SRS 280 och 880

APCO SLOW CLOSING AIR/VACUUM VALVES

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

HVAC Air Duct Leakage. November 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA

Transcription:

Application and esign Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized steel - Blade Type Airfoil - Blade Action Parallel - Linkage Plated steel out of airstream, concealed in jamb Axle Bearings Synthetic (acetal) Bronze, 304SS sleeve type Axle Material Plated steel 304SS Blade Seals TPE Silicone Jamb Seals 304SS - Sleeve 12 in. (305mm) 12 in. - 48 in. (305mm - 1219mm) Sleeve Gauge 20 ga. 14 ga. or 16 ga. Flange None 1 1/2 in. (38mm); Upstream side, ownstream side, Both Sides Air Straightener Polycarbonate - Honeycomb Actuator 24VAC 50/60 Hz 24VAC w/ auxiliary switches or manual quadrant AM-33 Air Measuring Station with VC-33 Control amper The AM-33 combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that both measures and regulates airflow volumes to a target set-point. The AM-33 comes standard with a modulating actuator and a properly sized pressure transducer that output a signal proportional to cfm. A field supplied controller can use the transducer's signal along with the flow formula: CFM = Area * K * (P transducer )m to regulate the modulating actuator to the target set-point. K & m are factory supplied variables specific to each damper. Ratings Velocity: 300 to 3000 fpm (1.5-15.2 m/s) Leakage: 6cfm/ft 2 @ 4 in. wg (110 cmh/m 2 @ 1 kpa) 3cfm/ft 2 @ 1 in. wg (55 cmh/m 2 @.25 kpa) Temperature: -20 F to 180 F (-29 C to 82ºC) Consult factory for temperature lower than -20 F (-29 C) Transducer Temperature: 0 F Airflow Monitoring Accuracy: 5% of reading *W & H dimension furnished approximately 1/4 in. (6mm) undersize. Features & Control Options 24VAC modulating actuator mounted externally or internally Factory supplied 0-10 VC pressure transducer Clean wrap Retaining angles W x H External Minimum Size Internal Single Section Maximum Size Multiple Section* Inches 6 x 6 12 x 8 48 x 74 144 x 148 mm 152 x 152 305 x 203 1219 x 1880 3658 x 3759 * For sizes larger than listed, consult factory. Installation instructions available at www.greenheck.com

AM-33 mounting styles Flange on Upstream Flange on Upstream Flange on on Upstream ownstream Flange on ownstream Airflow irection AMCA Certified Leakage ata Air leakage is based on operation between 32 F (0 C) and 120 F (49 C). Tested for leakage in accordance with ANSI/AMCA Standard 500-, Figure 5.5. Tested for air performance in accordance with ANSI/AMCA Standard 500-, Figures 5.2, 5.3 and 5.5. Torque ata are based on a torque of 7.0 in.lb./ft² (0.79 N m) applied to close and seat the damper during the test. AM-33 Leakage Class* Maximum amper Width 1 in. wg (0.25 kpa) 4 in. wg (1 kpa) 8 in. wg (2 kpa) 60 in. (1524mm) 1A 1 1 Greenheck Fan Corporation certifies that the model AM-33 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs.The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. *Leakage Class efinitions The maximum allowable leakage is defined by AMCA as the following: Leakage Class 1A - 3 cfm/ft 2 @ 1 in. wg (class 1A is only defined at 1 in. wg). Leakage Class 1-4 cfm/ft 2 @ 1 in. wg - 8 cfm/ft 2 @ 4 in. wg - 11 cfm/ft 2 @ 8 in. wg - 12.6 cfm/ft 2 @ 10 in. wg

AM-33 This pressure drop testing was conducted in accordance with AMCA Standard 500- using the three configurations shown. All data has been corrected to represent standard air at a density of 0.075 lb/ft3 (1.201kg/m3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to 6 estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by 6straight duct runs upstream and downstream of the damper. 6 Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system.

ata AM-33 Greenheck Fan Corporation certifies that the model 6 AM-33 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs.The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. AMCA 5.2 500 0.041 500 0.03 500 0.025 1000 0.131 1000 0.094 1000 0.078 1500 0.266 1500 0.189 1500 0.156 2000 0.437 2000 0.314 2000 0.259 2500 0.658 2500 0.474 2500 0.388 3000 0.927 3000 0.652 3000 0.533 3500 1.245 3500 0.876 3500 0.706 1.591 1.143 0.914 500 0.034 1000 0.103 1500 0.213 2000 0.357 2500 0.541 3000 0.757 3500 1.017 1.326 500 0.036 1000 0.102 1500 0.214 2000 0.359 2500 0.547 3000 0.772 3500 1.034 1.339 AMCA 5.3 6 Pressure rop 500 0.04 500 0.03 500 0.03 1000 0.12 61000 0.09 1000 0.07 1500 0.24 1500 0.17 1500 0.14 2000 0.40 2000 0.28 2000 0.23 2500 0.60 2500 0.43 2500 0.35 3000 0.84 3000 0.60 3000 0.48 3500 1.12 1.44 3500 0.80 1.03 3500 0.64 0.82 AMCA 5.5 500 0.03 1000 0.10 1500 0.20 2000 0.34 2500 0.51 3000 0.72 3500 0.97 1.26 500 0.03 1000 0.09 1500 0.19 2000 0.33 2500 0.50 3000 0.71 3500 0.96 1.24 500 0.07 500 0.05 500 0.05 1000 0.24 1000 0.19 1000 0.16 1500 0.50 1500 0.38 1500 0.34 2000 0.86 2000 0.65 2000 0.57 2500 1.33 2500 1.00 2500 0.88 3000 1.89 3000 1.43 3000 1.24 3500 2.57 3500 1.90 3500 1.67 3.30 2.52 2.19 500 0.06 1000 0.19 1500 0.41 2000 0.71 2500 1.09 3000 1.54 3500 2.08 2.70 500 0.05 1000 0.19 1500 0.41 2000 0.71 2500 1.10 3000 1.55 3500 2.10 2.75

Factory Supplied Controls By adding a factory supplied controller AM series airflow measuring dampers become a turn-key solution for measuring and controlling the flow of air. Go to www.greenheck.com for complete instructions on these two controllers. Vari-Green Constant Volume Controller Greenheck s Vari-Green Constant Volume Controller is a highly configurable analog based controller. The controller can accept a cfm setpoint either remotely by way of an analog input or locally by using touch sensitive buttons on its cover. The controller then regulates the position of the AM s actuator to deliver the requested cfm. An analog output on the controller also supplies a signal that is proportional to the real-time cfm. The Vari-Green Constant Volume Controller features a two line backlit LC display to show the user the current CFM setpoint, the real-time cfm, the current pressure reading, and the AM s actuator position. Constant Volume Varigreen amper Controller Specifications Control dampers meeting the following specifications shall be installed where shown on plans as an air monitor. station integral to the minimum outside air damper. The air measuring damper shall control the minimum amount of outside air as recommended by ASHRAE Standard 62 or California Title 24. The air measuring damper shall consist of: 16 ga. (1.5mm) galvanized steel hat channel frame with 5 in. (127mm) depth; airfoil shaped, galvanized steel double skin construction blades (14 ga. [2mm] equivalent thickness); blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow in either direction or pressure on either side of the damper. Axles shall be 1/2 in. (13mm) dia. plated steel turning in acetal bearings; TPE blade seals for 250 F (121 C) maximum temperature; flexible stainless steel jamb seals; and external (out of the airstream) blade-to-blade linkage. amper leakage rating to be in compliance with the IECC (International Energy Conservation Code) and not to exceed 3 cfm/ft2 (55 cmh/m2) at 1 in. wg (249 Pa). Testing and ratings to be in accordance with AMCA standard 500-. Basis of design is Greenheck model AM-33. Copyright 2016 Greenheck Fan Corporation AM-33 Rev. 8 February 2016