Partec PAS. Your Flow Cytometer.



Similar documents
CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles

CyFlow Space Your flexible flow cytometer

CyAn : 11 Parameter Desktop Flow Cytometer

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Introduction to flow cytometry

These particles have something in common

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

Immunophenotyping peripheral blood cells

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

APPLICATION INFORMATION

Spherotech, Inc Irma Lee Circle, Unit 101, Lake Forest, Illinois

Boundary-breaking acoustic focusing cytometry

Easy to use. Compact. Flexible. Sorting Chip

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Introduction to Flow Cytometry

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

Cell Cycle Tutorial. Contents

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

INSIDE THE BLACK BOX

Introduction to Flow Cytometry

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

Standardization, Calibration and Quality Control

BD FACSComp Software Tutorial

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

FloMax Software for Cytometry. Operating Manual - Data Analysis. Version 2.3, FloMax Operating Manual Data Analysis 1

Flow Cytometry A Basic Overview

FlowSight. Flow cytometry with vision

Introduction to Flow Cytometry:

BD FACSDiva TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY

Below is a list of things you should be aware of before you schedule your sort.

Flow Cytometry. flow cytometer DNA apoptosis ph

How to operate the BD FACSCanto flow cytometer

BD LSR II and FACSDiVa Software. Dr. Jens Fleischer, Basel Dr. Norbert Leclere,, Berlin

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

COMPENSATION MIT Flow Cytometry Core Facility

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Cytell Cell Imaging System

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit G June Beckman Coulter, Inc N. Harbor Blvd. Fullerton, CA 92835

Imaging and Bioinformatics Software

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility

FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS. By: Douaa Moh. Sayed

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...

Institut für Experimentelle Immunologie und Bildgebung

Principles of Flowcytometry

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH))

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

Flow cytometry basics fluidics, optics, electronics...

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

flow cytometry reinvented

1. Instrument Layout pg Summit Overview pg Data Storage and Data Files pgs Saving Data pg Start Up pg 8


Zeiss 780 Training Notes

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

Small-Particle Analysis

The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic

BD FACSCanto Flow Cytometer. Efficient Easy Powerful

BD CellQuest Pro Software Analysis Tutorial

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

Absolute counting using flow cytometry. Bright Count Microspheres

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

Fluorescent Array Imaging Reader

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Analyzer Experiment setup guide for LSRII and Canto s

Standard Operating Procedure

Chapter 12 Filters for FISH Imaging

LSR II Users Guide Stanford Shared FACS Facility 06/10/13

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

Bacterial Detection and Live/Dead Discrimination by Flow Cytometry

BD FACSVerse. Simply brilliant

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE

Becton-Dickinson FACSCalibur Flow Cytometer Instructions

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

Zecotek S Light Projection Network Marketing

Hoechst HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, )

Three Rules for Compensation Controls

LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry

use. 3,5 Apoptosis Viability Titration Assays

UCHC Guide to CellQuest Pro. FACS Calibur instruments

Cell Sorting. S3e Cell Sorter Quick Guide

FACSCanto RUO Special Order QUICK REFERENCE GUIDE

Setting up and calibration of a flow cytometer for multicolor immunophenotyping

EdU Flow Cytometry Kit. User Manual

MIRAX SCAN The new way of looking at pathology

BC Auto Hematology Analyzer

DIODE PUMPED CRYSTALASER

EDF Extended Depth of Field

Fluorescence Compensation. Jennifer Wilshire, PhD

Experiment 5. Lasers and laser mode structure

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

Transcription:

Partec PAS Your Flow Cytometer.

The Challenge... New sophisticated applications and increasing requirements for reliable routine results in the shortest possible time continue to impose a challenge for flow cytometry instrumentation, automation and software.... our Experience Partec, pioneer in flow cytometry for more than 30 years, contributes to these requirements with the new generation of Windows TM -based PAS Particle Analysing Systems. An innovative computer controlled flow system, the modular optical system with advanced photomultiplier tubes for all optical channels, recently available new computer and electronic technologies, for example new fast and precise 16 bit analog-to-digital converters, and the possibility for microsecond realtime data acquisition using the Windows TM operating system were combined in a completely new instrument and software design. All flow cytometry applications in healthcare, microbiology, food and cosmetics control, plant and animal cell analysis benefit from the unique features of this design - and this brochure tries to give a short overview about some of the striking features and results with the new PAS. We invite you to take part in the fascinating investigations the PAS offers us today. And we guarantee to offer you qualified scientific and technical application support and service, now and in the future. Partec Headquarters in Münster, Germany The PAS Particle Analysing System - Your Fully Equipped Bench-Top Flow Cytometer Available with a range of light sources, e.g. Argon lasers, ranging from 20 mw to 100 mw, 100 W mercury UV lamp, 25 mw red laser diode and solid state lasers, and 1 to 8 parameters, the optical configuration of the PAS is the optimum prerequisite for routine cell analysis applications, covering microbiology and small particle analysis, 4- colour immunophenotyping, precise volumetric absolute counting and DNA analysis. New upcoming applications, employing multiple light source excitation with UV and lasers and involving high precision DNA analysis with DAPI or Hoechst together with surface markers, e.g. for no-lyse immunophenotyping techniques, are now available with the PAS. PAS-III: Expandable by many light sources Additional larger external laser sources like NdYAG, HeCd or HeNe lasers can be added to the modular optical system by means of a stable optical bench support for both the instrument and extra light sources, thus offering a compact and rigid solution for the most demanding applications. Eight fully parallel optical parameters, each with its own photomultiplier tube (PMT), including the forward scatter PMT, give you the most flexible choice and offer the best sensitivity and enough space for future applications. Due to the built-in Windows TM computer and ergonomic TFT LCD display, fully equipped and side-by-side with the Robby TM sample automat and autoloader, the PAS requires no more space than a normal laboratory table and a normal electrical line connection, thus reducing your laboratory requirements to a minimum. By featuring standardized PC-computer components, the PAS can be directly integrated into your laboratory information system via barcode reader, automated Word / Excel reports and a fast Ethernet network connection.

The Flow The heart of the PAS is the unique quartz flow cuvette, ensuring that particles cross the UV and visible excitation light with best possible precision, well one after the other. The design of the flow cuvette incorporates more than 30 years of experience in handling fluids with sub-micrometer and nanoliter precision. Thanks to the optical and mechanical precision of the flow cuvette, superior results are guaranteed for all parameters, e.g. coefficients of variation (CVs) of better than 1% with DAPI staining - a prerequisite e.g. for high precision DNA measurements for tumor or chromosome analysis. The sample is transported with help of a computer controlled digital syringe pump, part of a virtually cross-contamination-free fluid system (< 0.1% cross-contamination). This system allows continuous flow absolute counting, displaying concentration results a few seconds after starting a sample analysis. Optics and Light Sources The 8-parameter optical system features a clear optical pathway, built upon Partec s legendary optical cubes. All optical elements, including the UV mercury lamp and the lasers, are mounted onto a single rigid optical bench, which guarantees optimum mechanical stability and avoids problems when moving the instrument to another place. By means of the built-in colour CCD camera, the stability of the sample flow and the sorting process (in conjunction with the closed system piezo-sorter) can be controlled in a video flow monitor on the LCD screen. For most applications, you will not need to change the standard configuration for side scatter (SSC), forward scatter (FSC) and 4-colour fluorescence analysis. The standard setup is optimized for all common dyes, e.g. FITC, GFP, PI, PE, PE-CY5, SR, APC, FDA, DAPI, and Hoechst. In its standard configuration, the PAS allows spatially separated 2- wavelength excitation analysis with UV + laser, laser diode + Ar laser or UV + laser diode, optimized by diaphragms in several intermediate image planes. However, the modular optical system lets you easily configure the PAS for special applications and other fluorochromes - simply by changing dichroics/filter blocks and diaphragms without time-consuming readjustments. For your routine and new applications, Partec offers you the assistance you need. The heart of the PAS: the synthetic quartz flow cuvette. Quartz optics guarantee high transmission for UV applications without temporal degradation. The PAS integrates an Ar-laser, red laser diode, and UV mercury arc lamp. Modular PAS optics built upon optical cubes for 8 parameters. For the PAS-III external lasers, e.g. NdYAG, HeCd or HeNe, can be mounted onto a common rigid support.

Computer and Electronics Each of the optical channels is equipped with an independent processor controlled pulse analyser for parallel pulse processing in order to minimize signal losses due to coincidence and dead-time effects. The logarithmic amplifiers, specified for a 6-decade range, provide safe dynamics for 4-decade operation. 16 bit (65536 channels) analogue-to-digital converters for each parameter are the fundament for software-based colour crosstalk compensation algorithms and other numerical operations, e.g. fluorescence ratio measurements, without artifacts. The computing power of the Pentium allows signal analysis, processing, and display of each event generated by a particle in real-time, while offering the convenience of the 32 bit Windows TM operating system. Real-time is a prerequisite for precise volumetric absolute counting and high speed and high purity sorting based on complex software-gates. The PAS is equipped with a 650 MB CD-Writer for convenient data storage and Ethernet network connection with 10 MB/s and 100 MB/s for an easy connection to your laboratory information system (LIS). Software The Windows TM FloMax software integrates instrument control, including acquisition, cell sorting, onand offline data analysis into one single software package. Ready prepared and freely adaptable instrument settings and panels facilitate switching between different applications. FloMax is optimized for microbiology analysis, immunophenotyping, cellcycle, DNA ploidy, and scientific flow cytometric analysis. Data is always stored as original data in FCS flow cytometry standard file format for easy exchange with other analysis software. One of the unique features is the on- and offline colour crosstalk compensation of the spectral overlap of fluorescence from simultaneously analysed dyes. The N-colour compensation algorithm allows a correction of the crosstalk between any parameters without need to rerun a sample. FloMax optimally supports the volumetric absolute counting feature of the PAS, displaying particle concentrations for any subsets of cells, even if defined by a gate at a later time after the acquisition. The FloMax Panel system allows automated analysis of repeating sample series employing different dyes or instrument settings. The FloMax Report system generates easy-toadapt result reports based on Microsoft Word templates (.dot - files) or Excel Macros written in Visual Basic. Built-in CD-Writer, Ethernet network connection and Barcode Reader facilitate data archive and transfer to laboratory information systems. FloMax FloMax graphical N-colour crosstalk compensation supports matrix-based on- and offline adjustments at any time without need to rerun samples. The flexible multi-tube panel system of FloMax automates routine processes. FloMax Report generates automated single or multi-tube panel and measurment series reports in Word or Excel.

True Volumetric Absolute Counting The PAS analyses concentrations of any particle subpopulations of interest using true volumetric absolute counting. This unique method is solely based on the fundamental definition of a particle concentration c, namely the counted number N of particles in a given volume V, c = N / V. In the PAS, the volume is measured directly by mechanical means, rather than by calibration with expensive beads with a (sometimes doubtful) given nominal concentration. Thus, the precision of volume measurement is defined by a fixed mechanical design, eliminating any errors related to varying bead concentrations. The PAS allows analysis of either a fixed volume as defined by the distance d between two platinum electrodes reaching into the sample tube with a given diameter 2r, or, alternatively, a volume of free choice involving the digital sample speed control. Benefits of true volumetric absolute counting: i) digital volumetric precision by mechanical design: better than 2% reproducibility, 5% precision, ii) no errors related to calibration, iii) no additional preparation time for reference beads, iv) no expenses for calibration beads. Schematics of true volumetric absolute counting, based on real-time acquisition and counting of the number N of particles passing the flow cuvette and mechanical measurement of volume V. BioSafety Sample Port for true Volumetric Absolute Counting. Sample Automation Barcodes are a significant automation component in many routine laboratories. Today, due to the variety of different systems, a flexible barcode system is most important. The PAS Barcode supports all common barcodes used for laboratory automation. Barcode reading is well integrated into the software. Besides for identifying samples and reagents, barcodes also serve as a safe selection among predefined panel protocols or instrument settings. For optimum sample automation, the PAS can be equipped with the Robby TM sample preparation automat and autoloader for carrousels of 36 sample tubes. Samples are prepared according to predefined protocols that can be freely adapted for special purposes. Controlled by the Windows TM RobbyPrep software, the preparation covers staining with up to 16 reagents, incubation, sample shaking and cell lysis. The analysis of complete carrousels is automated by FloMax, which combines the panel system with the Robby TM automat control. As a result, a fully automated process generates complete multi-page panel or routine series reports in Word or Excel format. Full walk-away automation including staining, lysing and sample analysis by the Windows TM controlled RobbyTM sample preparation automat and autoloader.

Bacteria Analysis FSC and SSC plots of spores and vegetative cells of Bacillus subtilis. Excitation with 488 nm by an argon laser (20mW). Absolute counting and measurement of RFP-expression (FL2: orange-red) of an E. coli population after excitation by a NdYAG-laser (532 nm, 50 mw): 40% of the E. coli population show the red fluorescence due to RFP-expression. Yeast Analysis Measurement of GFP-expression (FL1 GREEN) of a Salmonella sp. population after excitation by an argon laser (488 nm, 20 mw). DAPI (DNA, FL-IV) and nile red staining (neutral lipids, FL-III) of brewery yeasts after double wavelength excitation by HBOlamp (UV) and argon ion laser (488 nm, 20 mw). DNA Ploidy Analysis with DAPI and PI Tumor Analysis Cells of potato plant, 2n + 4n, stained with Partec CyStain UV (DAPI). Mamma carcinoma biopsy - laser scatter (488 nm, 20 mw) + DAPI excitation by HBO lamp. Cell Sorting Sorting of lymphocytes - selection of the sort window (left) and reanalysis (right). Sorting of a granulocyte subset - selection of the sort window (left) and reanalysis (right).

Immunophenotyping: 6 parameter, 4 Colour Fluorescence Analysis with ColorGating No-Lyse Leukocyte Analysis Simultaneous analysis of four antibody surface markers by argon laser and red laser diode excitation. CD34+ Volumetric Absolute Counting Dual wavelength excitation by UV lamp and laser. By using DAPI as trigger signal, full blood analysis is limited to the leukocytes. CD4/CD8 Volumetric Absolute Counting Rare event concentration analysis on CD34+cells. (patient sample). UV plus Ar-laser 2 Wavelength Excitation Routine concentration analysis on CD4/CD8 for HIV monitoring. Platelet Analysis Simultaneous analysis of DNA (DAPI) and antibody surface markers. Supported by the use of a PMT for the FSC parameter, the small platelets (PLT) can be easily discriminated from red blood cells (RBC) in the scatterplot. Leukocyte Depletion Process Control Analysis of leukocyte concentration based on CyStain (DAPI ) staining and volumetric absolute counting. Due to the digital nature (high signal to noise ratio) of the bright DAPI staining of the leukocyte nuclei, concentrations down to 0.01 cells/µl (10 cells / ml) can be safely determined.

PAS Specifications General Compact flow cytometer for automated sequential analysis of single cells and microscopic particles Scatter particle size range 0.2 µm - 200 µm Fluorescence sensitivity: 100 MEFS (FITC) or better Fluorescence resolution (CV): 1% or better (DAPI) Configurations with 1 to 8 optical parameters + time parameter Light Sources Built-in air-cooled Ar-ion laser with 20 mw at 488 nm (PAS and PAS-III) and 50 or 100 mw (PAS-III only) at 488 nm, 458 and 515 nm HBO mercury arc lamp, 100 W, for UV excitation and other wavelengths Diode laser 25 mw at 635 nm, temperature controlled Diode laser, 430 nm NdYAG 50 mw at 532 nm Instrument size PAS: 770 mm x 500 mm x 550 mm (WxHxD) Instrument size PAS-III: 1400 mm x 500 mm x 550 mm (WxHxD) Recommended laboratory table size (PAS): 1600 mm x 800 mm External lasers on optical bench support (PAS-III): HeCd 325 nm, 354 nm HeNe 30 mw at 633 nm Other lasers upon request Optics Modular optical system with 1 to 8 optical parameters with selected PMTs with integrated electronic preamplifier for each parameter, including FSC Standard setup and filters for FSC, SSC, FL1-FL6 Colour CCD camera for video flow monitor Köhler illumination by HBO lamp UV transmitting quartz optics Standard objective mount with high numerical aperture objective, high numerical aperture immersion gel coupling, e.g. for detection of weak cytokines (option) Various intermediate image planes for optimized spatial filtering by diaphragms Flow System Synthetic quartz flow cuvette for laminar sample transport with sheath fluid Sample port with computer controlled BioSafety cleaning system, avoids sample droplets and minimizes cross contamination True Volumetric Absolute Counting based on mechanical volume measurement, no need for reference particles Contamination-free computer controlled precision syringe pump for sample transport and volumetric absolute counting, pump speed continuously adjustable from 0-50 µl / s, sheath fluid pressure continuously adjustable from 0-300 mbar, easily accessible 5 l sheath fluid and waste reservoirs with filling level sensors Cell Sorter Closed piezo sorting system Minimizes sample hazards Analysis speed up to 15 000 particles / s, sorting speed up to 500 sorted particles / s for sort purities > 95% (depending on sample), video flow monitor for monitoring of sorting process - easy and reliable sorting setup. Robby sample automat and autoloader 36 tube carrousel Up to 16 reagents Sample shaker Windows TM RobbyPrep software Electronics and Computer Parallel signal processing for each of the optical channels with selectable linear, 3 or 4-decade logarithmic amplification (6-decade log amplifiers), pulse height, area and width analysis for doublet dicrimination, 16 bit analog-to-digital converter, trigger on any parameter or all parameters Upgradable built-in industry standard computer, Pentium processor (at least 800 MHz), 128 MB RAM, >30 GB harddisk, built-in 15 TFT LCD display, CCD camera video flow monitor on LCD window, external 17 or 21 monitor for dual screen setup (option), 650 MB CD-Writer, 3,5 Floppy Disk Drive, 100 MB ZIP drive optional, keyboard, mouse, barcode reader, 10 MB/s / 100 MB/s Ethernet connection, DeskJet colour printer, b&w or colour laser printer optional, printing via network Software Microsoft Windows TM 98 or 2000 operating system with full network support - Apple /Macintosh network connection optional 32 bit Windows TM FloMax software for routine and research applications 1-8-parameter real-time data acquisition and analysis Dual wavelength acquisition from spatially separated light sources with time-window delay-system Internal floating point numerics with double precision One and two parameter histograms and dotplots 64-32768 channels resolution for 1P histograms 32/32-1024/1024 channels for 2P dotplots Multiparameter N-colour crosstalk compensation, settings may be corrected any time Multiparameter ColorGating Ratio measurement Doublet discrimination based on pulse height, area and width analysis Peak and cluster analysis and statistics Robby TM sample automat control DNA cell cycle analysis DNA peak analysis Multitube panel system with automated acquisition Flow Cytometry Standard data format FCS 2.0 for storage of original and evaluated data Storage of gates and screen layout Automated data transfer of graphics, statistics and instrument settings to Word, Excel, other desktop publishing systems or laboratory information systems (LIS). Instruments, Reagents and Accessories Partec offers a broad range of instruments, protocols and reagents for microorganism detection, red blood cell lysing, DNA cell cycle and ploidy analysis, disposable CellTrics TM cell separation filters, sample tubes for volumetric absolute counting, UV objectives and more. Please inquire for any information for your application. Partec GmbH Otto-Hahn-Straße 32 D-48161 Münster Germany Telefon (xx49) 25 34 8 00 80 Telefax (xx49) 25 34 80 08 90 E-Mail: info@partec.de Internet: http://www.partec.de