7000 SERIES - ELECTRONIC TRANSFORMERS MYRRA encapsulated electronic transformers are Switched Mode Power Supplies based on Flyback topology. They constitute an interesting alternative to the traditional supply in the most common applications of power lower than W. ENERGY SAVING due to high efficiency and low standby power The applications for the Electronic serie are: o Alternative to the linear transformers in all AC/DC applications of power up to than W o Alternative to DC/DC converters for application in D.C.current (Telecom supplies, electric substations etc.) o Industrial, domestic and consumer electronics applications o Standby devices and others DC or AC auxiliary supplies With the same footprint as a EI30 transformer, they will replace: - 0 Hz Transformer - Fuse - Bridge Rectifier - Filtering Capacitor Regulated types will also replace linear regulator and heatsink MAIN FEATURES o Wide input voltage range o Increased power. 3 x compared to standard EI30 transformer o Better energetic efficiency: 70% typical compared to 0% for the conventional supply o Very low Standby Power consumption: meets requirements of Energy Star or EC Code of Conduct o Same footprint as EI30 transformer : Upgrade your application without redesign of PCB STANDARDS Meets all requirements of: o EN 6090 o EN 6033 o EN 618-2-17 o Uses UL listed components o Uses UL 9-V0 plastic and resin EMC STANDARDS Conducted and radiated emissions conform to o EN 01-1 o EN 022 class B Immunity conform to o EN 01-2 o EN 61000--x 1/
7000 SERIES - ELECTRONIC TRANSFORMERS ONE OUTPUT 2. & W - Regulated 8 to 26 Volts AC 8 to 370 Volts DC Input Frequency 7 to 0 Hz Output voltage accuracy (full load ) ± 2% Line output voltage variation ± 0.3% Load output voltage variation ± 0.% Energy consumption and efficiency : Meets requirements of Energy Star and EC Code of Conduct Input / Output Isolation test voltage: 000 Vac Storage temperature: - 0 C / + 8 C Output voltage Output current Efficiency (%) 71 3.3 70 2. 6 +70 72 0 2.7 68 +70 73 9 270 2. 72 +70 7 210 2. 7 +70 7 1 170 2. 7 +70 76 2 110 2. 77 +70 711 3.3 130.2 6 +0 7 900. 68 +0 713 9 0 72 +0 71 20 7 +0 71 1 320 76 +0 716 2 220 79 +0 pins pin 7: DC output +V pin 9: DC output 0V 2/
7000 SERIES - ELECTRONIC TRANSFORMERS ONE OUTPUT 3.2 & W Non Regulated 8 to 26 Volts AC 8 to 370 Volts DC Input Frequency 7 to 0 Hz Output voltage accuracy (full load) Line output voltage variation Load output voltage variation 0/ +30% Input / Output Isolation test voltage: 000 Vac Storage temperature: - 0 C / + 8 C No load input power < 300mW Output current Efficiency (%) 711 200 2. 7 +70 7133 9 360 3.2 73 +70 713 270 3.2 7 +70 7136 2 130 3.2 80 +70 7163 9 60 * 73 +0 716 20 * 7 +0 7166 2 210 * 80 +0 * Nota: Power up to.w is possible with input voltage 97 Vac pins pin 7: DC output +V pin 9: DC output 0V 3/
7000 SERIES - ELECTRONIC TRANSFORMERS TWO COMMON OUTPUTS 3 to W - Regulated 8 to 26Volts AC 8 to 370V DC Input Frequency 7 to 0 Hz Output voltage accuracy : see table for 10 to 100% rated load of each output (includes line and load variations) Energy consumption and efficiency : Meets requirements of Energy Star or EC Code of Conduct The 2 outputs share a common 0v reference. This enables closer coupling and a better crossregulation of the outputs Input / Output Isolation test voltage: 000 Vac Storage temperature: - 0 C / + 8 C accuracy Efficiency (%) 723 72 72 726 727 +10. +7 +1 +7 + +. + + +1-1 380 max 100 max 300 max 70 max 300 max 00 (600max) 170 max * * 3.2 ± 10% ± 8% ± 8% 6 +70 6 +60 * Nota: Power up to W is possible with input voltage 97 Vac and 0 C pins pin 6: Common output 0V pin 7: DC output 1 pin 10: DC output 2 /
7000 SERIES - ELECTRONIC TRANSFORMERS TWO ISOLATED OUTPUTS 3 to W - Regulated 8 to 26Volts AC 8 to 370V DC Input Frequency 7 to 0 Hz Output voltage accuracy : see table for 10 to 100% rated load of each output (includes line and load variations) Energy consumption and efficiency : Meets requirements of Energy Star or EC Code of Conduct 2 isolated outputs - only is regulated and should provide the higher power Input / Output Isolation test voltage: 000 Vac Output1 / isolation : 000Vac Storage temperature: - 0 C / + 8 C (max W) accuracy Efficiency (%) 722 72 72 727 728 1 1 18 8 30 (600max) 30 max 16 (300max) 16 max 13 (200max) 13 max 00 (600max) 170 max 10 (200max) 10 max 3. 66 +60 68 +60 6 pins pin 6: DC output1 0V pin 7: DC output1 +V pin 9: DC output2 0V pin 10: DC output2 +V /