CompactLogix Power Supplies Specifications



Similar documents
1756 ControlLogix Chassis Specifications

1788 Linking Device Specifications

1756 ControlLogix Power Supplies Specifications

1756 ControlLogix Integrated Motion Modules Specifications

USB-to-Data Highway Plus Cable

1756 ControlLogix I/O Specifications

Bimetallic Overload Relay Specifications

ControlNet Standard and High-flex Coax Cable

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Micro800 Programmable Controller Family. Bulletin 2080 Selection Guide

Compact I/O End Caps/Terminators

Stratix 5700 Network Address Translation. Quick Start

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

Universal Serial Bus (USB) to DH-485 Interface Converter

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Hard Disk Drive (HDD)

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

1769 Compact I/O Modules Specifications

Three-phase monitoring relay CM-PFE

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Redundancy Module QUINT-DIODE/40

Logix5000 Controllers Nonvolatile Memory Card

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

MicroLogix 1100 Embedded Web Server

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

PHOENIX CONTACT Features

Digital input modules

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Fiber Optic Cable Installation

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Power Supplies 3. SDN-P DIN Rail Series

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

PanelView Component Specifications

CQM1-SF200/CS1W-SF200

Foxboro Evo Process Automation System

RM4TG20 three-phase network control relay RM4-T - range V

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Application Technique. Safety Function: Magnetic Door Switch Monitoring

PanelView 800 Terminals

ADM1TE 5/30A DIN rail single phase two wire energy meter

MCR1900 Media Converter 19-Slot Chassis

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

DeltaV SISnet Repeater

CompactRIO crio-9052

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

SMC -3 Specifications

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AXIS T81B22 DC 30W Midspan

Compact I/O Expansion Power Supplies

Stratix Ethernet Switch Specifications

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Type: DILM32 10(24V50HZ) Article No.:

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Manual motor starter MS116

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Safety technique. Emergency stop module BO 5988 safemaster

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Allen-Bradley/Rockwell

TX OPEN RS232/485 module

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

STRATO LED Drivers 70W, Single output

Electronic overload relay EF19 and EF45

PowerFlex Dynamic Braking Resistor Calculator

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Rotary Disconnect Switch Specifications

User Manual. DeviceNet Network Configuration

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

NX safety stand-alone

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Thermistor motor protection

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Technicaldata General

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS25 Screw Clamp Terminal Blocks Feed-through

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Transcription:

Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4 Topic 1768 CompactLogix Power Supplies 3 1769 Compact I/O Power Supplies 7 Page Environmental Specifications - 1768 and 1769 Power Supplies Attribute Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) Temperature, storage IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Nonoperating Damp Heat) Vibration IEC 60068-2-6 (Test Fc, Operating) Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock) Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock) 1768-PA3, 1769-PB3 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4 0 60 C (32 140 F) -40 85 C (-40 185 F) 5 95% noncondensing 5 g @ 10 500 Hz 30 g 50 g

Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. IMPORTANT Identifies information that is critical for successful application and understanding of the product. ATTENTION Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence SHOCK HAZARD Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures. Rockwell Automation, Rockwell Software, Allen-Bradley, TechConnect, Compact I/O, and CompactLogix are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. 2 Publication 1769-TD008A-EN-P - January 2010

1768 CompactLogix Power Supplies The 1768 backplane requires one 1768 power supply. The power supply is a dual input supply that operates in multiple ranges. The power supply also offers a 24V dc external power source. The power supply sends 24V dc to the controller in slot 0. The controller converts the 24V dc to 5V dc and 24V dc and distributes it as needed. 5V and 24V power to 1769 I/O modules on the right side of the controller 24V power to 1768 modules on the left side of the controller Power supply sends 24V DC to the controller. Power Supply Communication or Motion Controller 1769 I/O Controller sends - 5V DC to 1768 modules - 5V and 24V DC to 1769 I/O modules The 1768 modules do not have a distance rating to the 1768 power supply. For the 1769 I/O modules in the 1768 system, the distance rating is from the controller and not the 1768 power supply. Technical Specifications - 1768 CompactLogix Power Supplies Attribute 1768-PA3 1768-PB3 Input voltage range 85 265V AC 108 132V DC 16.8...31.2V DC Input voltage, nom 120V/220V AC 24V DC Input frequency range 47 63 Hz DC Input power, max 120VA/120 W 112 W Output power, max Output power, min 90 W 24V DC to backplane: 3.5 24V DC to user-accessible terminal block: 0.25 A 6 W 24V DC to backplane: 0.25 A 24V DC to user-accessible terminal block: 0.0 A Power dissipation 30 W 22 W Inrush current, max 50 A @ 85 132V AC 80 A @ 195 265V AC 50 A @ 16.8...31.2V DC (1) Publication 1769-TD008A-EN-P - January 2010 3

Technical Specifications - 1768 CompactLogix Power Supplies Attribute 1768-PA3 1768-PB3 Isolation voltage Internal overcurrent protection 250V, reinforced insulation type, input to system and 24V DC AUX Tested at 4250V DC for 60 s 150V, basic insulation type, 24V DC AUX to system Tested at 2200V dc for 60 s Non-replaceable fuse is soldered in place Recommended external overcurrent protection 4 6 A @ 28.5 36.7 A 2 S 8...12 A @ 166...250 A 2 S Overcurrent protection 15 A, user supplied Weight, approx. 0.98 kg (2.15 lb) 1.01 kg (2.22 lb) Dimensions (HxWxD), approx. Module location Mounting screw torque 131.25 x 132.75 x 105.50 mm (5.17 x 5.23 x 4.15 in.) DIN rail or panel mount Wire category 1 - on power ports (2) Wire size, input power terminal Wire size, output power terminal Conductor screw torque North American temperature code Output #1: 24V DC to backplane 1.16 N m (10 lb in) - use M4 or #8 screws 14 AWG (2.5 mm 2 ) solid or stranded copper wire rated at 75 C (167 F) or greater, 1.2 mm (3/64 in.) insulation maximum 14 AWG (2.5 mm 2 ) 22 AWG (0.25 mm 2 ) solid or stranded copper wire rated at 75 C (167 C) or greater, 1.2 mm (3/64 in.) insulation max 0.6 N m (5 lb in) T4 Ride-through interval time, min 25 ms @ 90 W 5 ms @ 90 W Full power hold-up interval Extended hold-up interval Output #2: 24V DC to front panel terminal block Voltage Output disable Enclosure type rating (1) Does not include X-capacitor charging current. 5 ms @ 90 W 8...12 s @ 1.25 W 18...27.60V @ front panel Disable output during hold-up periods None (open-style) (2) Use this conductor category information for planning conductor routing as described in the system level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. 4 Publication 1769-TD008A-EN-P - January 2010

Certifications - 1768 CompactLogix Power Supplies Certification (1) 1768-PA3, 1768-PB3 c-ul-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. CE C-Tick European Union 89/336 EEC EMC Directive, compliant with: EN 50082-2; Industrial Immunity EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 73/23/EEC LVD Directive, compliant with: EN 1010-1; Meas./Control/Lab Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details. Power Requirements and Transformer Sizing - 1768 CompactLogix Power Supplies Publication 1769-TD008A-EN-P - January 2010 5

Mounting Dimensions - 1768 CompactLogix Power Supplies 132.66 mm (5.22 in.) 105.1 mm (4.14 in.) 100.5 mm (3.96 in.) 131.5 mm (5.18 in.) 6 Publication 1769-TD008A-EN-P - January 2010

1769 Compact I/O Power Supplies Each 1769-L3x controller and additional bank of I/O modules requires a 1769 power supply. Place 1769 I/O modules to the left or right of the 1769 power supply. As many as eight I/O modules can be placed on each side of the power supply. Each 1769 module also has a power supply distance rating (the number of modules from the power supply). Each module must be located within its distance rating. See the specifications for the module to determine its distance rating. Technical Specifications - 1769 Compact I/O Power Supplies Attribute 1769-PA2 1769-PB2 1769-PA4 1769-PB4 Input voltage range 85 265V AC 19.2...31.2V DC 85 265V AC or 170...265V AC, switch selectable 19.2...31.2V DC Input voltage, nom 120V/220V AC 24V DC 120V/220V AC 24V DC Power consumption 100 VA @ 120V AC 50 VA @ 24V DC 200 VA @ 120V AC 100 VA @ 24V DC 130 VA @ 240V AC 240 VA @ 240V AC Power dissipation 8 W @ 60 C (140 F) 7.5 W @ 60 C (140 F) 18 W @ 60 C (140 F) 14.5 W @ 60 C (140 F) Current capacity @ 5V 2.0 A 2.0 A 4.0 A 4.0 A Current capacity @ 24V 0.8 A 0.8 A 2.0 A 2.0 A Inrush current, max 25 A @ 132V AC 30 A @ 31.2V DC 25 A @ 132V AC 30 A @ 31.2V DC Isolation voltage 265V (continuous), 75V (continuous), 265V (continuous), 75V (continuous), reinforced insulation type reinforced insulation type reinforced insulation type reinforced insulation type (IEC Class 1 grounding (IEC Class 1 grounding (IEC Class 1 grounding (IEC Class 1 grounding required) required) required) required) Routine tested @ Routine tested at Routine tested at Routine tested at 2596V DC for 1 s, AC 1697V DC for 1 s, DC 2596V DC for 1 s, AC 1697V DC for 1 s, DC power input to system and power input to system power input to system power input to system AC power input to 24V DC user power Fuse type Wickmann 19195-3.15A Wickmann 19193-6.3A Wickmann 19195-3.15A Wickmann 19193-6.3A Littelfuse 02183.15MXP Littelfuse 021706.3MXP Littelfuse 02183.15MXP Weight, approx. 525 g (1.16 lb) 630 g (1.39 lb) Dimensions (HxWxD), approx. 118 x 70 x 87 mm (4.65 x 2.76 x 3.43 in.) Module location DIN rail or panel mount Mounting screw torque 1.16 N m (10 lb in) - use M4 or #8 screws Power supply distance rating 8 Littelfuse 021706.3MXP 8 I/O modules can be connected on either side of the power supply for a maximum of 16 modules Wire category (1) 1 - on power ports 2 - on power ports 1 - on power ports 2 - on power ports Wire size 14 AWG (2.5 mm 2 ) solid copper wire rated at 90 C (194 F) or greater, 1.2 mm (3/64 in.) insulation max North American temperature code T3C IEC temperature code T4 T4 Enclosure type rating None (open-style) (1) Use this conductor category information for planning conductor routing as described in the system level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Publication 1769-TD008A-EN-P - January 2010 7

Certifications - 1769 Compact Power Supplies Certification (1) 1769-PA2, 1769-PA4 1769-PB2, 1769-PB4 c-ul-us CE C-Tick UL Listed for Class 1, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E10314 European Union 2004/108/EC EMC Directive, compliant with: EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions European Union 94/9/EC ATEX Directive, compliant with: EN 60079-15; Potentially Explosive Atmospheres, Protection n (Zone 2) EN 60079-0; General Requirements (Zone 2) (1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details. 8 Publication 1769-TD008A-EN-P - January 2010

Power Requirements and Transformer Sizing - 1769 CompactLogix Power Supplies Total Output: 68 W @ 55 C (131 F) or below 61 W @ 60 C (140 F) or below Total Output: 68 W @ 55 C (131 F) or below 61 W @ 60 C (140 F) or below Publication 1769-TD008A-EN-P - January 2010 9

Mounting Dimensions - 1769 CompactLogix Power Supplies 70 mm (2.76 in.) 87 mm (3.42 in.) 131.7 mm (5.18 in.) 10 Publication 1769-TD008A-EN-P - January 2010

Notes: Publication 1769-TD008A-EN-P - January 2010 11

Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support/, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://www.rockwellautomation.com/support/. Installation Assistance If you experience an anomoly within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running. United States or Canada 1.440.646.3434 Outside United States or Canada Use the Worldwide Locator at http://www.rockwellautomation.com/support/americas/phone_en.html, or contact your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Outside United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Publication 1769-TD008A-EN-P - January 2010 12 Copyright 2010 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.