THE PER-UNIT SYSTEM. (2) The per-unit values for various components lie within a narrow range regardless of the equipment rating.



Similar documents
Power Technology Issue 104. Modeling of Two-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer

EEL303: Power Engineering I - Tutorial 4

Power Technology Issue 106. Modeling of Three-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

Chapter 12: Three Phase Circuits

Chapter 24. Three-Phase Voltage Generation

CURRENT TRANSFORMERS INSTALLATION GUIDE

SYNCHRONOUS MACHINES

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

Transformer circuit calculations

Short Circuit Current Calculations

EE 221 Circuits II. Chapter 13 Magnetically Coupled Circuits

Frequency response: Resonance, Bandwidth, Q factor

Three phase circuits

13 ELECTRIC MOTORS Basic Relations

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26

Modeling of Transmission Lines

Series and Parallel Resistive Circuits

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Circuit Analysis using the Node and Mesh Methods

Loading Considerations When Paralleling Transformers

3-Phase AC Calculations Revisited

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

The Flyback Converter

Coupled Inductors. Introducing Coupled Inductors

How To Wire A Three Phase, Single Phase, Wye Transformer

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

Radial Distribution Test Feeders

The full wave rectifier consists of two diodes and a resister as shown in Figure

DC-DC Converter Basics

See Horenstein 4.3 and 4.4

Prepared By: Sheilani Binti Shaari Department of Electrical Engineering/PKB

Physical Address: City: State: Zip Code:

How To Calculate The Power Gain Of An Opamp

Transformer Calculations

Direct Current Motors

Symmetrical Fault Calculations

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

TRANSFORMER: THREE PHASE

Impedance Matching. Using transformers Using matching networks

JEFFERSON ELECTRIC, INC. Buck-Boost Transformer Application Manual

Series and Parallel Circuits

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

Induction Motor Theory

GE Multilin technical note

GUIDE FOR TESTING POWER TRANSFORMERS

Module Title: Electrotechnology for Mech L7

45. The peak value of an alternating current in a 1500-W device is 5.4 A. What is the rms voltage across?

30. Bode Plots. Introduction

= (0.400 A) (4.80 V) = 1.92 W = (0.400 A) (7.20 V) = 2.88 W

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

Full representation of the real transformer

FREQUENCY CONTROLLED AC MOTOR DRIVE

OPERATIONAL AMPLIFIERS

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

7. Reactive energy compensation

MODELING AND TESTING OF UNBALANCED LOADING AND VOLTAGE REGULATION. Prepared For: California Energy Commission Public Interest Energy Research Program

Introduction to Paralleling of LTC Transformers by the Circulating Current Method

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

How To Limit Voltage Unbalance

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

The generation and supply of electricity within the U.K is achieved through the use of a 3-phase system.

Power System Harmonics

TRANSFORMERS. Unit 14 OBJECTIVES

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

Transient analysis of integrated solar/diesel hybrid power system using MATLAB Simulink

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

Lab 14: 3-phase alternator.

VOLTAGE REGULATOR AND PARALLEL OPERATION

BJT AC Analysis. by Kenneth A. Kuhn Oct. 20, 2001, rev Aug. 31, 2008

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

Tutorial One: Calculation of leakage inductance of transformer using FEM MVA, 132 kv/33kv, Y/, Ampere-turns: , No.

Common Emitter BJT Amplifier Design Current Mirror Design

Introduction. Three-phase induction motors are the most common and frequently encountered machines in industry

ACCURACY OF POTENTIALTRANSFORMERS

Motor Efficiency and Power Factor ME 416/516

8 Speed control of Induction Machines

electronics fundamentals

Presentation of the France Transfo factories

How To Understand And Understand The Electrical Power System

PHASOR DIAGRAMS HANDS-ON RELAY SCHOOL WSU PULLMAN, WA. RON ALEXANDER - BPA

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Chapter 29 Alternating-Current Circuits

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

RC & RL Transient Response

Sensitivity Analysis of Waveform Distortion Assessment for Wind Plants

1 Introduction. 2 Two Phases. J.L. Kirtley Jr.

INDUCTION REGULATOR. Objective:

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS

TA Kahraman Yumak ELK412 - Distribution of Electrical Energy Lab. Notes v Spring web.itu.edu.tr/yumakk. Distance Protection

Appendix N: GENERATOR DATA SHEET FOR SYNCHRONOUS GENERATORS CONNECTED TO PG&E ELECTRIC SYSTEM

Transcription:

THE PER-UNIT SYSTEM An interconnected power system typically consists of many different voltage levels given a system containing several transformers and/or rotating machines. The per-unit system simplifies the analysis of complex power systems by choosing a common set of base parameters in terms of which, all systems quantities are defined. The different voltage levels disappear and the overall system reduces to a set of impedances. The primary advantages of the per-unit system are: (1) The per-unit values for transformer impedance, voltage and current are identical when referred to the primary and secondary (no need to reflect impedances from one side of the transformer to the other, the transformer is a single impedance). (2) The per-unit values for various components lie within a narrow range regardless of the equipment rating. (3) The per-unit values clearly represent the relative values of the circuit quantities. Many of the ubiquitous scaling constants are eliminated. (4) Ideal for computer simulations. The definition of any quantity (voltage, current, power, impedance) in the per-unit system is The complete characterization of a per-unit system requires that all four base values be defined. Given the four base values, the per-unit quantities are defined as

Note that the numerator terms in the previous equations are in general complex while the base values are real-valued. Once any two of the four base values (V base, I base, S base, and Z base ) are defined, the remaining two base values can be determined according their fundamental circuit relationships. Usually the base values of power and voltage are selected and the base values of current and impedance are determined according to If we also assume that: (1) the value of S base is constant for all points in the power system, and (2) the ratio of voltage bases on either side of a transformer is chosen to equal the ratio of the transformer voltage ratings, then the transformer per-unit impedance remains unchanged when referred from one side of a transformer to the other. This will allow us to eliminate the ideal transformer from the transformer model (i.e., we will not have to reflect impedances from one side of the transformer to the other.)

Example (Per-unit system, transformer models) A single phase 20 kva, 480/120, 60 Hz single-phase transformer has an impedance of Z eq2 = 0.0525p78.13 o S referred to the LV winding. Determine the per-unit transformer impedance referred to the LV winding and the HV winding. The transformer impedance referred to the HV winding is given by According to our convention, the base values for this system are The resulting impedance bases are and the resulting per-unit impedances are Since the per-unit impedances are equal for both sides of the transformer, we may designate a single transformer impedance.

Given that the per-unit transformer impedances referred to the two sides of the transformer are equal, the per-unit equivalent model for the transformer reduces to that shown below. Note that there are no primed quantities in the per-unit equivalent circuit. Thus, there is no need to reflect impedances when using this model. Using the per-unit transformer model eliminates the need to scale quantities by the transformer turns ratio, thus eliminating a common source for error. The per-unit full-load copper loss associated with a given transformer can be shown to be equal to R eq,pu. According to the previously given definition of transformer copper loss, the per-unit copper loss is given by where S base = V 1,rated I 1,rated = V 2,rated I 2,rated. Under full-load conditions, the primary and secondary current and voltage magnitudes are the transformer rated values. This gives

Thus, the resistance term in the per-unit transformer equivalent circuit also represents the per-unit value of the transformer full-load copper loss. Example (Per-unit transformer equivalent circuit) The equivalent impedance of a 10 kva, 2200 V/220 V, 60 Hz transformer is 10.4 + j31.3 S when referred to the high-voltage side. The transformer core losses are 120 W. Determine (a.) the per-unit equivalent circuit (b.) the voltage regulation when the transformer delivers 75% of full load at a power factor of 0.6 lagging, and ( c.) the transformer efficiency given the transformer load of part (b.). (a.)

(b.) For a load which is 75% of rated value at a power factor of 0.6 lagging (2 v! 2 i = 53.13 o ), the per-unit values of the voltage V 2,pu and the current I 2,pu are (using the voltage V 2,pu as the phase reference) (c.) The transformer efficiency in terms of per-unit values is

The transformer per-unit real output power is found by multiplying the per-unit complex output power by the power factor. The full load per-unit copper losses are equal to the real part of the per-unit transformer impedance. This relationship can be stated in terms of the current and resistance under full load conditions. At 75% of the rated current, the per-unit copper losses are The per-unit core losses are found by normalizing the actual core losses. The efficiency of the transformer is

Example (System analysis using per-unit model) Given V s = 220p0 o, X line = 2 S and Z load = (0.9 + j0.2) S in the two transformer circuit shown below, (a.) draw the per-unit circuit, labeling all values. (b.) determine the per-unit load current and the actual load current. W e start by choosing S base. With more than one transformer in the circuit, we could choose either kva rating. Let S base = 30 kva. The value of V base should be chosen in the three zones to match the ratio of the voltage ratings on either side of each transformer. If we choose in order to match the voltage ratings of the step-up transformer, we must choose V base3 such that the ratio of V base2 to V base3 equals the voltage ratio of 460/115 or

This choice of power and voltage bases in the three zones gives the following current and impedance bases: The circuit quantities are then transformed into per-unit values.

The transformer impedances are The overall per-unit equivalent circuit is shown below. The per-unit load current is given by The actual load current is