Engineered for Accuracy and Simple Installation VANTAGE 4000. Ultrasonic Transit-Time Flowmeter



Similar documents
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

O C M III. Open Channel Flow Monitor

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Open channel & partially filled pipe Ultrasonic flow meters

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

PIEZOMETER AIRFLOW MEASURING RING

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

For Multi-Parameter Meters see mvx

Sanitary Type Electronic Flow Switches

Application/Connection Examples

DigitalFlow GF868 Panametrics Ultrasonic Flare Gas Mass Flowmeter. GE Sensing. Features. Applications

2.24. Pump Controller 704. Data Sheet

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.

Temperature & Humidity SMS Alert Controller

Electronic Flow Switches

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Interface Level And Point Level Analyzers & Sensors

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Sensing & Inspection Technologies. Applications. Features

INTREPID Perimeter Intrusion Detection System

Perimeter Security System

40.3. Control Relays and Timers

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Transmitter Interface Program

User's Guide. Integrating Sound Level Datalogger. Model Introduction

FAQ s on Siemens Magmeters

COMBIMASS. Technical Data COMBIMASS eco-bio +

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

Series DFMT Digital Paddlewheel Flowmeter

Electromagnetic Flow Meter

In-Line Electronic Flow Switches

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

How To Use A Flowmeter

UTM10 Series Ultrasonic Transit-time Flowmeters

Regards from the Team at Rheology Solutions.

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

USB-500 Series Stand-Alone, Low-Cost Data Loggers

How To Use A Ds340 (Dsp)

Centro-Matic Automatic Lubrication Systems System Controls

Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed.

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

PRODUCT PROFILE FEATURES

USB-500/600 Series Low-Cost Data Loggers and Accessories

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

PowerLogic Sub Meter Display (SMD and SMDOPN)

Carbon Monoxide (CO) Gas Detection and Control System

The L&J Engineering Model MCG 1500SFI Servo Gauge

Microcor Wireless Transmitter (MWT)

Section TELEPHONE AUTOMATIC DIALER SYSTEM

USB-500 Series Low-Cost Data Loggers and Accessories

Metering for today s systems

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

Repeaters and Mimics Data Sheet

WEATHER STATION FOR SOLAR FARM MONITORING

Web-Based Remote Monitoring & Datalogging

Galvanic Parts Per Million Dissolved Oxygen Systems

Typical Aluminum GFM Mass Flow Meter

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

Digital and Analog I/O

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

3500/93 System Display

USB-500/600 Series Low-Cost Data Loggers and Accessories

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

Mobrey open channel flow measurement systems

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

SMART SENSOR COLLECTION

Thermatel Model TA1 Mass Flow Transmitter

5000V Graphical Megohmmeter Model 5070

Electronic Control Devices The European Product Catalogue 2007

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

PORTAFLOW 300. Ultrasonic Flowmeter Manual

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Sample specifications for an effective Flow Monitoring Services RFP

PORTABLE FLOW METER KITS TDS-100H

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

PortaSens ll G AS DETECTOR

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

IFC 070 Technical Datasheet

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Current Monitoring Kit

In-Line Electronic Flow Switches

Unidirectional Transmitter/ Receiver Units Introduction

Transcription:

Engineered for Accuracy and Simple Installation VANTAGE 4000 Ultrasonic Transit-Time Flowmeter

VANTAGE 4000 TRANSIT-TIME FLOWMETER Model 4400 One 4-20 ma Output One SPDT Relay RS232 Serial Port Internal Datalogger Model 4600 Two 4-20 ma Outputs Three SPDT Relays RS232 Serial Port RS485 Serial Port Internal Datalogger FACTORY PRE-PROGRAMMED The engineers at Eastech realized that for a new product to be successful, it must be simple to install and quickly made operational. In order to accomplish this goal, every Vantage 4000 is shipped PROGRAMMING VALIDATION to the field factory PIPE SIZE: 16 IN. pre-programmed to PIPE MATERIAL DUCTILE the conditions set forth FLOW MEDIA: WATER by the customer. Preprogramming specifica- MAX PRESSURE: 100 PSI FLOW DIRECTION: UNI-DIR tions are electronically confirmed on the display of the transmitter. If changes to the meter s factory pre-programming is required, re-programming can simply be accomplished on the meter keypad or through the Auto-Programming feature. This feature allows plant personnel to re-program the Vantage 4000 by simply downloading the revised flow data from a PC or laptop directly into the meter. Accuracy & Reliability 0 The Vantage 4000 employs the latest DSP microprocessor technology. An exclusive signal processing technique combines correlation and FFT detection methods in order to ensure the highest degree of accuracy and reliability possible. Turndown: 400 :1 Repeatability: 0.25% Accuracy: ±1% of actual flow 2

SPEEDRAIL TM SENSOR MOUNTING Since the externally mounted sensor is the preferred design for transmitting signals through pipe or conduit, a new one-piece SpeedRail TM sensor mounting system was developed. Mounting of both sensors is quickly and accurately accomplished in two simple steps. Lock the self-aligning mounting rail to the pipe or conduit and load in the sensors. Once the sensors are connected to the transmitter, the Vantage 4000 is ready to measure flow. STEP 1 STEP 2 FLOW DATA GRAPHING PACKAGE QTrend 2007 is an Excel Workbook Flow Data Graphing Package specifically designed to interface with every meter offered within the Eastech product line. QTrend incorporates specific formulas capable of automating the process of charting and displaying all data contained within the onboard logger of the meter. Each individual Worksheet presents an OPEN FILE button. Upon initiation, the file browser is displayed with a complete list of all CSV files contained within the directory. Choosing a file of interest will automatically import the data from that file into the QTrend Excel Workbook. By simply clicking on the tab labeled CHART, a comprehensive flow evaluation and trend analysis Worksheet is displayed. All graphed data is presented in a color-coded format that coincides with a complete set of corresponding Data Description Keys prominently displayed on the left perimeter of the Worksheet. For specific analysis, associated data may be temporarily hidden from view by a simple click on the appropriate Data Description Key. Maximum and minimum values for every measurement category are updated and then displayed within each graphical window. Flow and Level (Total Flow Hidden) 3

TRANSMITTER Eastech was the first company to utilize a phase shift detection system in the design of transit-time flowmeters. This technique greatly improves time difference detectability, which in turn, enhances accuracy and operating stability while substantially reducing the effects of noise. ACCURACY & RELIABILITY Water & Wastewater Sewage Treatment Acids & Toxic Liquids Petroleum Products HVAC & Irrigation Turndown: 400 :1 Repeatability: 0.25% Accuracy: ±1% of actual flow The electronic design of the Vantage 4000 utilizes the latest microprocessor technology and operates in conjunction with a DSP floating point coprocessor. An exclusive signal processing technique combines correlation and FFT detection methods to ensure the highest degree of accuracy and reliability. Flash memory is employed for logging of flow data. Up to 8 channels can be logged including flow, velocity and totals for one or multiple sensors. The storage capacity for a single channel logging at 5 minute intervals is 113 days. In addition, graphs may be visually displayed in pre-programmed time intervals. Daily summary allows viewing of the previous eight days. This includes times, dates, averages, minimums, maximums and totals. Plant operating personnel also have the ability to simply download logger data through the use of a standard laptop. Model 4400 One 4-20 ma Output One SPDT Relay RS232 Serial Port Internal Datalogger Model 4600 Two 4-20 ma Outputs Three SPDT Relays RS232 Serial Port RS485 Serial Port Internal Datalogger PROGRAMMING For fast and simple installation, each Vantage Series 4000 is pre-programmed at the factory for customer specific flow measurement applications. If re-programming is required in the field, the Auto-Programming feature allows for the corrected flow data to simply be downloaded from a PC or laptop directly into the meter. Additionally, a self-prompting backlit display, with a menu-driven guide allows for 15 minute programming of standard applications and 30 minute programming of in-depth data logging applications and auxiliary outputs. Programming of the meter is accomplished through the 16 button keypad. The LCD display is a backlit 128 x 64 graphic module. A simple to use drill-down menu structure allows for quick programming and set-up of the meter. Most common pipe sizes and schedules are stored in memory for ease in programming a specific application. Non-volatile memory ensures that programming constants are not lost during disruption of power. 4

FL OW DATA LOGGING The Vantage 4000 has a 256K Byte logger with storage intervals. The logger can be programmed for various time intervals. Up to 8 channels can be logged including flow, velocity and totals for one or multiple sensors.the storage capacity for a single channel @ 5 minute intervals is 113 days. IEEE floating point storage is used. Daily Averages Flash memory is employed for logging of flow data. Data is retrieved by viewing the local display or downloaded via the serial port. Daily summaries allow viewing of the previous eight days. Included are times, dates, averages, minimums, maximums and totals. Logger Graph A graph may be visually displayed on the 4000.The graph will display the stored logger data in pre-programmed time intervals. 09/05/2014 18:36.02 Flw1 230 GPM Vel1 6.15 FPS 09/05T 14:50-15:00 TIME DATA RETRIEVAL The Vantage 4000 is designed for reliable and accurate retrieval of data either on-site or remotely. The unit is equipped, as standard, with an integrated data logger capable of storing large amounts of information for later analysis. Because of its multiple output capability, this information may simply be retrieved through the use of one of the following methods. Multiple Outputs Two 4-20 ma Three SPDT Relays RS232 RS485 Isolated, 800 ohms maximum. Available for alarm conditions. With Modbus protocol. Flow control is CTS/RTS or none. DB-9 connection. With Modbus protocol, isolated. The RS-232 & RS-485 can be set with different slave I.D.s. INTEGRATED CHART RECORDER A SINGLE NEMA 4, 4X UNIT INCORPORATING A CHART RECORDER, FLOWMETER AND DATALOGGER Fully Integrated Package Powered by Flowmeter User Selectable Output Ranges and Recording Times Accuracy Power Source Channels Recorder Display Chart Rotation Chart Range Chart Size:.05% Full Scale 100/240 VAC, 50/60 Hz 12-28 VDC @ 300 ma One 112 x 16 Graphical User Selectable 0-100% of Full Scale 100 mm Diameter Recording Time Response Time Calibration Relays Chart Replacement Alarm Environmental protection Temperature 24 Hour, 7 day, 31 day (user selectable) 4 sec. - 60 sec. (user selectable) Pen Arm 3 SPDT (plug-in) 3 Amps Flashing LED (Red) Nema 4, 4X Standard: -4 to 158 F (-20 to 70 C) With Heater: -40 to 158 F (-40 to 70 C) 5

ACOUSTIC SENSORS Eastech offers a wide range of sensor options covering a multitude of applications. Simple walk through installation instructions are graphically displayed in the IOM for local reference in the field The externally mounted sensor is the preferred design when acoustic signals are capable of being transmitted through pipe or conduit. EXTERNALLY MOUNTED SENSOR Externally mounted sensors are the preferred design when acoustic signals are capable of being transmitted through pipe or conduit. The sensors are fully potted for use in highly corrosive areas. Both sensors and mounting hardware are designed to resist corrosion, function when buried or submerged and operate over a wide temperature range of -30 to 150 F (-30 to 300 F optional). External sensors are suitable for placement on all metallic and plastic piping, with the exception of pit cast iron and layered fiberglass pipe. Application: 1 and larger. Plastic, Metallic, Asbestos Cement and Ductile/Cast Pipe. SPEEDRAIL MOUNTING Externally mounted non-wetted sensors (V-Shot) STEP 1 STEP 2 Since externally mounted sensors are the preferred design for transmitting signals through pipe or conduit, a new one piece SpeedRail TM sensor mounting system was developed. Mounting of both sensors is quickly and accurately accomplished in two simple steps. Lock the self-aligning mounting rail to the pipe or conduit and load in the sensors. Externally mounted non-wetted sensors (Z-Shot) Once the sensors are connected to the transmitter, the Vantage 4000 is ready to measure flow. 6

INSTREAM SENSOR In open conduits over 12 inches in width or in large concrete pipes where the outside of the pipe is not accessible, the instream sensor is recommended for accurate fluid velocity measurement. The design of the sensor facilitates simple installation. Sensor configuration allows flush mounting against the sidewall. For accuracy and ease of installation, a unique internal hoop design is available with premounted instream sensors. This mounting arrangement makes installation fast and precise. Sensors are constructed of PVC and are fully potted. Application: Large diameter pipe and pipe or conduit not accessible from the outside. WINDOWED SENSOR Fabricated spool pieces are available in a windowed sensor design with a wide choice of end connections and materials of construction. Spool pieces are supplied with both sensors mounted and calibrated to the electronics. Windowed sensors transmit and receive ultrasonic pulses through an acoustic window which is in contact with the flow stream. The design allows sensor removal without de-watering of the line. The sensors and windows are constructed of Ultem thermoplastic material and carry a temperature rating of 150 F and a pressure rating of 150 psi. Application: 3 to 48 with stainless or carbon steel construction and ANSI, AWWA and plain end connections. HOT SHOT SENSOR Hot Shot sensors are utilized on piping or conduits that inhibit the transmission of acoustic energy. A standard concrete saddle tap is employed for penetration of the pipe wall. Hot Shot sensors are available for 12 and larger pipe. The sensor design allows for flush mounting within the conduit, thereby eliminating turbulence or the build-up of solids around the measuring point. Sensors are provided with an integral valve in order to allow sensor removal without shutting the process down. Constructed of PVC and fully potted, the sensors carry a pressure rating of 150 psi. Application: Concrete, Asbestos, Cement, Fiberglass Wrapped, Wood Stave, heavily corroded steel pipe and pipes with considerable calcium build-up. MULTI-PATH Two and three path diametrical sensor configurations are recommended for applications that do not have normal upstream straight runs to produce well developed velocity profiles. The average axial velocity component for each acoustic path is utilized to establish the velocity profile. The velocity profile is then numerically integrated over the conduit s cross-sectional area to determine the volumetric flow rate. As a result, flowmeter accuracy is relatively independent of the velocity profile. 2 Paths 3 Paths 7

SPECIFICATIONS PERFORMANCE Linearity ± 0.25% Repeatability 0.25% Accuracy ±0.5% of actual flow Turndown 400 : 1 Power Supply High immunity: Approvals CE, UL, CSA Input Range 100 to 240 VAC Input Freq. Range 50 to 60 Hz SENSORS Pipe Diameter 1 to 120 (above 120, consult factory) Temperature Rating -30 to 150 F Optional to 300 F (Clamp-on only) Sensor Pressure Rating Max. Cable Distance Clamp-on (1-300 ) Not applicable 1000 ft. Instream (12-120 ) 150 PSI 1000 ft. Wetted (12-120 ) 150 PSI 1000 ft. Windowed (3-48 ) 250 PSI 250 ft. Materials of Construction Sensors: Anod. Alum./Ultem /PVC Clamp-on hardware Anod. Alum. Hot-Shot Valve Body Brass Sensor Cable Triax Beldon 9222 (50 ft. std.) TRANSMITTER ENCLOSURE Standard Nema, 4, 4X polycarbonate (9.25 x 8.87 x 5.38 ) Accessories Heater and thermostat, Door Lock, Modem TEMPERATURE Standard -4 to 158 F (-20 to 70 C) With Heater -40 to 158 F (-40 to 70 C) OUTPUTS 4-20 ma Analog isolated into 800 ohms max, monitored to detect open circuits. RFI and gas discharge surge protection and two fuses. Relay Alarms SPDT relays (pluggable) 3.0A @ 120VAC / 24VDC RS-232 Serial Port 1200-38400 Baud, Modbus RTU protocol RS-485 Serial Port Optically isolated, Modbus RTU protocol DC Power Out 12 VDC. 100mA maximum DISPLAY Backlit LCD 128 x 64 Graphic Module POWER Wattage 12 Voltage 100/240 VAC, 50/60 Hz / 12-28VDC @ 300 ma. DATA LOGGING Non-volatile flash memory, storage of up to 32768 records. ORDERING GUIDE Enclosure Sensors Extra Cable Options Data Retrieval 4400 (Uni-directional) Nema 4, 4x; General Purpose One 4-20mA output One SPDT Relay RS-232 serial port 4600 (Bi-directional) Nema 4, 4x; General Purpose Two 4-20mA outputs 3 SPDT Relays RS-232 serial port RS-485 serial port Internal Datalogger For Div. 1 Explosionproof areas contact factory. CHART RECORDER 15 Nema 4,4X IP66 Circular Chart (please specify) 1 Day 7 Day 31 Day (Please specify pipe size, pipe material, flow media and flow direction) External Clamp-On (1-42 Dia. Pipe) AS1 External Clamp-On (48-120 Dia. Pipe) AS2 External Clamp-On (High Temp.: 300 F) AS3 Instream (12-120 Dia. Pipe) AS4 Wetted Hot Shot (12-120 Dia. Pipe) AS5 Windowed (3-48 Dia. Pipe) AS6 Multi-Path contact factory. Note: Each sensor is equipped with 50 feet of cable as standard. 100 ft. B Above 100 ft. Please specify exact cable length. ft. Factory Calibrated A (No Charge) Heater & Thermostat B Keylock C Splice Kit D Extra Relays (Model 4400) 2 Relays E 3 Relays F Modem (phone line) M 4250 S. 76th E. Ave. Tulsa, OK 74145 email: info@eastechflow.com 918-664-1212 800-226-3569 Fax: 918-664-8494 www.eastechflow.com