Self-Calibration and Hybrid Mapping



Similar documents
Spectral Line II. G ij (t) are calibrated as in chapter 5. To calibrated B ij (ν), observe a bright source that is known to be spectrally flat

Part 2: Analysis of Relationship Between Two Variables

SURVEYING WITH GPS. GPS has become a standard surveying technique in most surveying practices

Water Flow in. Alex Vlachos, Valve July 28, 2010

Characterizing Digital Cameras with the Photon Transfer Curve

The Development of High-Resolution Imaging in Radio Astronomy

Amy Mioduszewski NRAO. NRAO s 2008 Synthesis Imaging Workshop) Synthesis Imaging in Radio Astronomy

The Effects of Start Prices on the Performance of the Certainty Equivalent Pricing Policy

Lecture 14. Point Spread Function (PSF)

Ionospheric Research with the LOFAR Telescope

Final Year Project Progress Report. Frequency-Domain Adaptive Filtering. Myles Friel. Supervisor: Dr.Edward Jones

From Visibilities to Images Tom Muxlow, JBCA

Signal to Noise Instrumental Excel Assignment

CS Introduction to Data Mining Instructor: Abdullah Mueen

physics 1/12/2016 Chapter 20 Lecture Chapter 20 Traveling Waves

CAIM Correlator Monitoring Server

SGN-1158 Introduction to Signal Processing Test. Solutions

A comparison of radio direction-finding technologies. Paul Denisowski, Applications Engineer Rohde & Schwarz

ENGINEERING METROLOGY

Fraunhofer Diffraction

Selecting Receiving Antennas for Radio Tracking

Introduction into Real-Time Network Adjustment with Geo++ GNSMART

Data Structures and Algorithms

1 Review of Least Squares Solutions to Overdetermined Systems

A synonym is a word that has the same or almost the same definition of

RF Measurements Using a Modular Digitizer

Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications

Blind Deconvolution of Barcodes via Dictionary Analysis and Wiener Filter of Barcode Subsections

Chapter 11 PARABOLIC DISH FEEDS PERFORMANCE ANALYSIS Paul Wade N1BWT 1997,1998

Big Ideas in Mathematics

Function Guide for the Fourier Transformation Package SPIRE-UOL-DOC

MestRe-C User Guide Megan Bragg 04/14/05

Measuring Line Edge Roughness: Fluctuations in Uncertainty

Fibre Bragg Grating Sensors An Introduction to Bragg gratings and interrogation techniques

Macromodels of Packages Via Scattering Data and Complex Frequency Hopping

Integrating Quality Assurance into the GIS Project Life Cycle

The Aulterra Neutralizer Reduces the Intensity of Cell Phone Radiation

Digital Camera Imaging Evaluation

Capacity Limits of MIMO Channels

Solving Linear Equations in One Variable. Worked Examples

Post Processing Service

The human pipeline: distributed data reduction for ALMA

Network Analyzer Operation

1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number

Uses of Derivative Spectroscopy

Simple Regression Theory II 2010 Samuel L. Baker

Sound Pressure Measurement

Broad Crested Weirs. I. Introduction

Application Note AN-00125

Ultrasound Distance Measurement

First steps in VLA continuum data reduction with AIPS

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

Charting the Transient Radio Sky on Sub-Second Time-Scales with LOFAR

Comparison with GPS Time Transfer and VLBI Time Transfer

The Point-Slope Form

Current Status of Development of New VLBI Data Analysis Software

How to Turn an AC Induction Motor Into a DC Motor (A Matter of Perspective) Steve Bowling Application Segments Engineer Microchip Technology, Inc.

Computational Optical Imaging - Optique Numerique. -- Deconvolution --

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Trimble CenterPoint RTX Post-Processing Services FAQs

Measuring large areas by white light interferometry at the nanopositioning and nanomeasuring machine (NPMM)

Three-dimensional vision using structured light applied to quality control in production line

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Linear Threshold Units

Step Response of RC Circuits

A Primer on Mathematical Statistics and Univariate Distributions; The Normal Distribution; The GLM with the Normal Distribution

Hedging Illiquid FX Options: An Empirical Analysis of Alternative Hedging Strategies

Author: Dr. Society of Electrophysio. Reference: Electrodes. should include: electrode shape size use. direction.

Imputing Missing Data using SAS

AN EXPLANATION OF JOINT DIAGRAMS

The Real Business Cycle model

DSAM Digital Quality Index (DQI) A New Technique for Assessing Downstream Digital Services

The MOS Transistor in Weak Inversion

Spike-Based Sensing and Processing: What are spikes good for? John G. Harris Electrical and Computer Engineering Dept

Measurement Systems Correlation MSC for Suppliers

Reformulating the monitor placement problem: Optimal Network-wide wide Sampling

Real Business Cycle Models

SOFTWARE FOR GENERATION OF SPECTRUM COMPATIBLE TIME HISTORY

Lecture Notes on Linear Search

Scanners and How to Use Them

Convolution, Correlation, & Fourier Transforms. James R. Graham 10/25/2005

Theory of electrons and positrons

Introduction to Natural Computation. Lecture 15. Fruitflies for Frequency Assignment. Alberto Moraglio

PHASE ESTIMATION ALGORITHM FOR FREQUENCY HOPPED BINARY PSK AND DPSK WAVEFORMS WITH SMALL NUMBER OF REFERENCE SYMBOLS

The continuous and discrete Fourier transforms

Optical modeling of finite element surface displacements using commercial software

FTIR Instrumentation

Multiphase Flow - Appendices

INTRODUCTION TO ERRORS AND ERROR ANALYSIS

Logistic Regression. Jia Li. Department of Statistics The Pennsylvania State University. Logistic Regression

System Identification for Acoustic Comms.:

Language Modeling. Chapter Introduction

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

AP PHYSICS 2012 SCORING GUIDELINES

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

PRACTICAL GUIDE TO DATA SMOOTHING AND FILTERING

Designing a learning system

Transcription:

Self-Calibration and Hybrid Mapping Andrei Lobanov MPIfR Bonn European Radio Interferometry School Bonn, 11/09/2007

Lecture Outline Initial calibration and its deficiencies Visibility errors and dynamic range in interferometric images Closure quantities Hybrid imaging Basics of self-calibration Practical examples 2

Initial calibration Initial calibration: determining the empirical corrections for time-variable instrumental or environmental factors that cannot be measured, or monitored, directly. The calibration equation: 3

Measured quantities Measured complex visibilities: Measured visibility amplitudes: Measured visibility phases: 4

A priori calibration: problems The initial calibration is usually determined with substantial inaccuracies. Main reasons for these inaccuracies are: Instrumental: antenna and source positions, station clocks rates and offsets are uncertain. Environmental: tropospheric water vapor fluctuations and ionospheric electron content fluctuations introduce variable phase offsets at different antennas. Logistical: the gains can hardly be measured in an immediate conjunction with observation of astronomical targets. 5

A point source at 22 GHz 6

Should we worry? Typical errors reach φ 0.1rad in phase, ε 1% in amplitude Is this too bad? A random, antenna-based phase error φ present at all antennas would limit the dynamic range to D = 1 N( N 1) N φ 2 2φ The same applies to amplitude errors, since one can substitute φ ε. In an observation consisting of M scans with independent errors: D ~ M N φ Bottomline: relying on a priori calibration may not be sufficient! 7

Calibration: Remedies Redundant calibration: solving for the gains using pairs of antennas that measure the same (u,v) sample. Determines variable antenna gains up to a linear phase slope. Advantage: model independent. Problem: reduces SNR of the estimated true visibilities. Astronomical calibration: use calibrators to remove instrumental effects. Phase referencing: frequent observations of a nearby calibrator source. Can only correct phase errors. Significant fraction of observing time is spent on calibrators. Used effectively for imaging weak sources. 8

Calibration: Remedies II Hybrid imaging: relies on the use of closure quantities that can be applied to remove instrumental contributions to visibility phases and amplitudes i Closure phases: ψij ψki j ψjk k i Aij j Closure amplitudes: Ajl Aik l Akl k 9

Hybrid Mapping 1. Choose an initial model: I Model 2. Predict visibilities for the model: V Model = FT(I Model ) 3. Keep observed visibility amplitudes 4. Select new visibility phases by modifying model visibility phases to be consistent with the observed closure phases. 5. Produce new dirty image from new visibilities. 6. Produce a new model I Model by CLEAN-ing the new dirty image. 7. If the process has not converged, go back to Step (2). 10

Hybrid Mapping: Difficulties Proper treatment of noise is difficult (noise is additive only in vector visibility, not in the amplitude or phase). Not easy to choose the optimal set of closure quantities. Calibration effects in radio imaging are really related to antennas, not baselines.... We shold probably look for an antenna-based method for improving a priori calibration 11

Calibration: Remedies III Self-calibration calibration: antenna gains are considered free parameters that can be iteratively adjusted to provide optimal correspondence between a model of the target source and the set of visibilities observed. Most commonly applied method. Advantages: universality. Uses implicitly the constraints provided by the closure quantities. Difficulty: depends on a priori knowledge of source structure. 12

Self-Calibration Self-calibration uses a model of the target source to solve for improved values for the complex gains of the individual antennas Advantages Gains are derived for correct time, not by interpolation. Gains are derived for correct direction on celestial sphere. Solution is fairly robust if there are many baselines. Disadvantages Requires a sufficiently bright source. Results depend on the assumed model. If the model is incorrect, it will be built into the derived gains, leading to incorrect visibilities and images. 13

Point Source For a point source, the calibration equation becomes: This equation can be solved for antenna gains via least squares algorithm. Significant redundancy: N-1 baselines contribute to gain estimate for any antenna. 14

Extended Source Can use a model of the calibrator structure, obtaining: Can then correct for estimated antenna gains: These corrections can be smoothed or interpolated if desired. 15

Extended Source II The extended calibrator case transforms effectively into the point-source calibrator case by dividing by the model visibilities: 16

Self-Calibration Cycle 1. Produce an initial source model, using any a priory information of the structure. 2. Use the model to convert observed source into a pseudo-point source. 3. Solve for the complex gains. 4. Find corrected visibility 5. Form a new model from the corrected data. 6. Go to Step 2, unless current model is satisfactory. 17

Self-Calibration Strategies Initial model - Point source, CLEAN components from initial image, uv-model fit. Phase/amplitude self-calibration - Start with phase only self-calibration: amplitude errors are relatively unimportant at dynamic ranges of up to ~1000! Tapering and weighting - Simple source: all baselines can be used. Complex source: selfcalibrate first most compact structures (use long baselines, uniform weighting, uv-tapering). Solution intervals - Phases: as short as allowed by SNR. Amplitudes: should not go to short solution intervals, as this has a great danger of freezing the model into the data! (especially for arrays with relatively small number of elements). 18

When to use Self-Cal Self-calibration is needed when calibration errors are evident through one or both of the following conditions: The background noise is considerably higher than expected There are convolutional artifacts around objects, especially point sources Calibration errors should not be confused with effects of poor Fourier plane sampling such as: Low spatial frequency errors due to lack of short spacings Multiplicative fringes (due to deconvolution errors) Deconvolution errors around moderately resolved sources 19

Pushing the Limits Self-calibration can be applied if SNR on most baselines is greater than one. For a point source, the error in the gain solution is: Phase only: Amplitude and phase: When the gain errors are significantly smaller than one, then the noise in the final image approaches its expected level. 20

Example Self-calibration and hybrid mapping of VLBI data on 0212+735 (Walker 1995) 21

Example II 22

Summary Direct imaging and CLEAN-ing interferometry data are almost always insufficient for producing high quality images Interferometric data suffer from imperfect initial calibration and various time variable factors that must be corrected for in an empirical procedure. Self-calibration and hybrid imaging can be used for correcting the initial calibration. Especially important for VLBI observations. Can something go wrong? We ll find out on Thursday 23