Terminal Blocks & Power Distribution Terminal Blocks. Make your connection



Similar documents
Power Distribution & Terminal Blocks

1492 Marker Cards & Marking Systems

Circuit Breakers. Next Generation of Protection Capabilities

Datasheet. AC Outlet DIN-Rail Mountable Receptacles

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

General Purpose, Interposing, Solid-State and Specialty Relays. Bulletin 700

Bulletin 1489 Circuit Breakers. Selection Guide

Bimetallic Overload Relay Specifications

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

ZS25 Screw Clamp Terminal Blocks Feed-through

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire

picomax The Pluggable Connection System

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A

CompactLogix Power Supplies Specifications

AdvAntAge SerieS Switch-rAted iec Pin And Sleeve

Block width on rail (mm) Standard block* is shown on blue background

Feed-through terminal block - SSK 110 KER-EX

TX OPEN RS232/485 module

Rotary Disconnect Switch Specifications

ZS10 Screw Clamp Terminal Block

The Rail-Mounted Terminal Block System

This product can be assembled to the baseplate maintaining 5 mm center-to-center spacing. Thus any number of poles can end-to-end stack.

Redundancy Module QUINT-DIODE/40

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

The range of rail-mounted terminal blocks. for a perfect electrical installation.

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relay EF19 and EF45

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Circuit Breakers. NRC Series. NRC Series

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Provides one channel for Ethernet over existing

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Quick Reference Guide Euro Style Terminal Blocks

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Provides one channel for Ethernet over existing

HARTING Ethernet Cabling 4-poles Overview

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

How To Build A Powerline Box Powerline Generator

Bulletin 150 SMC Flex Smart Motor Controller Specifications

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 4-poles Overview

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Miniature Circuit Breakers and Supplementary Protectors

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Spring Cage Feed-Through Terminal Blocks ST

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Product and functional description

Circuit Breaker. Description

Power Commander Power Distribution Units from Wiremold/Legrand offer

Cable/Conduit Conversion

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Universal MATE-N-LOK Connectors

BETA Protecting SITOR Semiconductor Fuses

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

1756 ControlLogix Chassis Specifications

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Power Supplies 3. SDN-P DIN Rail Series

Relés e Contatores de Estado Sólido SIRIUS

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Technicaldata General

5SV Residual Current Protective Devices

40.3. Control Relays and Timers

gesis IP + Heavy Duty Class I, Zone 2

Vilter motor starter solutions The NEW industry standard in motor starter packages

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Electronic overload relay EF65, EF96 and EF146

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

MCC Ratings. Voltage Rating

D-Line Contactors, Overload Relays and Accessories

1788 Linking Device Specifications

Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

R.C.C.B. s two-pole LEXIC

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

08. SEK IDC CONNECTORS

CITY OF LOS ANGELES CALIFORNIA

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Relay mounting systems

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Selection Guide. Bulletin 194R/140U External Operating Handles

Terminal Blocks. BA Series. Specifications. Model BA111T BA211T BA311T BA411S

The power module is Feature Number 8800-F2-901.

Transcription:

Terminal Blocks & Power Distribution Terminal Blocks Make your connection

IEC TERMINAL BLOCKS PRODUCT SPOTLIGHT Leading the industry in efficiency and productivity, the Bulletin 1492 family of IEC terminal blocks includes a broad range of DIN rail mountable products with screw and spring-clamp connections, which are designed for safety, installation ease and ruggedness. All Allen-Bradley IEC terminal blocks are IP2X finger-safe and meet recognized international IEC, UL, CSA and ATEX standards. Parts of the family are available in up to ten different colors, with an extensive range of accessories to provide simple solutions for your unique wiring challenges. Bulletin 1492-J and 1492-W Screw Connection Terminal Blocks Time-proven termination method UL tested for multiple wire terminations per connection point (up to five on certain terminal blocks) 1492-J terminal blocks have a self-locking design with steel clamps and screws 1492-W family offers basic feed-through and grounding terminal blocks in a space-saving design Bulletin 1492-L Spring-Clamp Terminal Blocks Typically 30 50% faster to wire than screw type connections Constant spring tension is ideal for vibration environment Wire insertion into top of block affords high visibility

POWER DISTRIBUTION BLOCKS PRODUCT SPOTLIGHT Rockwell Automation offers a broad line of Allen-Bradley Power Distribution Blocks, which are designed to meet most application needs. The Power Blocks feature terminal identification options (either write-on marking surface or marker retention feature). In addition, each block is marked with wire range, tightening torque requirements and SCCR values to simplify installation. Bulletin 1492-PD Open Construction Distribution Blocks Ideal for distributing power to multiple loads Feed-through and Splicer blocks allow easy connection of field wiring to a cabinet Miniature block versions offer high current carrying capacity in a very small package to save on panel space High-fault SCCR up to 100 ka Bulletin 1492-PDL UL 1953 Listed Power Distribution Blocks Numerous connector configurations High-fault SCCR up to 100 ka Hinged covers allow easy access and protection from accidental contact Feeder spacing UL listed components Bulletin 1492-PDE Enclosed Power Distribution Blocks Numerous connector configurations IP20 protection from the front Multi-pole assembly possible with easily gangable units Markers are available for easy terminal identification High-fault SCCR up to 100 ka IEC 60947-7-7-1

MARKING SYSTEMS & ACCESSORIES PRODUCT SPOTLIGHT Allen-Bradley Marking Solutions enable efficient identification of your connections. A variety of markers are available: individual snap-in, hinged and self-adhesive, as well as linked markers for more efficient installation. Marker cards can be used on many Allen-Bradley products including terminal blocks, I/O devices and other industrial components. ClearMark Printer The ClearMark Printer provides quality printing in an easy-to-use format for high-volume marking needs. Fast: Less than 2 minutes to print and set a full marker card Easy: Integrated feeder for up to 20 marker cards Low-maintenance: Automatically cycles as needed to keep ink flowing High-quality printing: 600 or 1200 dpi Color printing: use spot color for printing on white marker cards for visual distinction X-Y Plotter The Bulletin 1492 X-Y Plotter offers flexible marking capabilities. Suggested for mid-volume marking needs Plotting can be done with etching ink pens or permanent marker Offers the capability to mark portions of marker cards as needed Custom and Pre-printed Marker Cards For customers with low-volume marking needs, we offer pre-printed and custom marker cards. These products are created in a Rockwell Automation facility with a ClearMark Printer Standard sequences are available from stock and customer-created files are printed on request ClearTools Software Customers can efficiently create markers from basic numbering to sequences and images with ClearTools software. Use auto-fill feature to create sequences of data Import from a variety of file formats Print from the library of symbols or use your own image Download ClearTools software at: http://ab.com/industrialcontrols/ products/terminal_blocks_and_wiring/ marking_systems_access/ marking_systems_family1.html Bulletin 1492 DIN Rail Receptacle Convenient 15 A or 20 A power source in the panel Quick to snap on 35 mm DIN rail and easy to wire Can also be panel mounted Available with ground fault circuit interrupter (GFCI) or standard duplex outlets Feature of visual indication of power included with GFCI receptacle

TERMINAL BLOCKS QUICK SELECTION GUIDE Voltage Rating Current Rating Wire Range (Rated Cross Section)* Density Ho Product Family Features IEC Terminal Blocks 1492-J Self-locking screw type clamp design Family includes standard and specialty terminal blocks with a wide range of accessories 1492-W Basic portfolio of space-saver screw type connection terminal blocks 1492-L Spring-clamp connection for ease of installation Products include standard and specialty terminal blocks for a variety of applications and 300V AC/DC and 300V AC/DC 25 228 A 20 85 A 15 120 A #22 250 MCM AWG (2.5 120 mm 2 ) #30 4 AWG (2.5 16 mm 2 ) #26 2 AWG (1.5 35 mm 2 ) 59 11 pcs/ft (196 37 pcs/m) 61 27 pcs/ft (200 90 pcs/m) 87 18 pcs/ft (285 62 pcs/m) 1492-C Open construction screw type terminal blocks Portfolio covers a range of wire sizes and treatments as well as some specialty terminal blocks 20 195 A #22 1/0 AWG (0.5 50 mm 2 ) 30 16 pcs/ft (98 52 pcs/m) Power Distribuition Terminal Blocks NEMA/EEMAC Terminal Blocks 1492-F Open construction screw type terminal blocks in a low-profile design 1492-H High-density finger-safe screw type terminal blocks Portfolio includes single-level, double-level and specialty terminal blocks 1492-HC and -HJ Provides a simple way to add a bank of terminal blocks in new or existing equipment with no mounting rails required Available in banks of six or twelve poles 1492-15T and -25T Panel-mounted terminal blocks for higher temperature requirements Gangable for multi-pole installation 1492-E Panel-mounted pull-apart terminal blocks allow for easy swapping of field wiring 300V AC/DC Open contruction styles 1492-PD Covers available (optional) UL component recognized CSA certified Aluminum or copper connectors Splicer versions Distribution versions up to 12 wires/pole UL category XCFR2 1492-PDL UL listed (UL 1953) CSA certified Aluminum connectors Splicer versions Distribution versions up to 12 wires/pole Covers included UL category QPQS 1492-PDE UR component recognized CSA certified Enclosed styles Aluminum or copper connectors Splicer versions Distribution versions up to 8 wires/pole UL category XCFR2 * North American wire range per NEC Table 310-16 using 75 C and 90 C stranded Copper wire. 25 A 24 55 A 25 A 35 45 A 25 60 A 115 A 760 A 175 A 335 A 175 A 510 A #22 #14 AWG (0.5 2.5 mm 2 ) #30 8 AWG (0.5 10 mm 2 ) #18 12 AWG (1 4 mm 2 ) #16 10 AWG (1.5 6 mm 2 ) #20 4 AWG (0.75 25mm 2 ) 600 kcmil #14 (300 2.5 mm 2 ) 600 kcmil #14 (300 2.5 mm 2 ) 400 kcmil #14 (185 2.5 mm 2 ) 35 30 pcs/ft (115 98 pcs/m) 50 37 pcs/ft (164 123 pcs/m)

using Temperature Range Material Flammability Rating UL94 Colors Certifications Mounting Compatible with snap-in markers for Allen-Bradley marking systems? -58 +248 F (-50 +120 C) V0 Also available for some products: UR, CSA, CE, ATEX DIN rail yes -40 +195 F (-40 +90 C) V2 Also available for some products: UR, CSA, CE, ATEX DIN rail yes -58 +248 F (-50 +120 C) V0 Also available for some products: UR, CSA,CE, ATEX DIN rail yes V2 Also available: UR, CSA A-B rail, some also DIN rail no V2 Also available: UR, CSA A-B rail no V2 Also available UR, CSA, CE A-B rail, some also DIN rail some V2 UR, CSA panel no -40 +300 F (-40 +149 C) HB panel no V2 UR, CSA panel no Max 150 C V0 UR, CSA, CE panel no Max 125 C V0 UL, CSA, CE panel no Max 125 C V0 UR, CSA, CE panel yes

NEMA/EEMAC TERMINAL BLOCKS PRODUCT SPOTLIGHT The Bulletin 1492 family of NEMA/EEMAC devices include terminal blocks that are available in at least ten colors for easy circuit identification. Most are available preassembled on a breakaway mounting channel, complete with one end anchor, one retaining clip and one end barrier. Bulletin 1492-F and 1492-C Open Construction Terminal Blocks Termination capability for solid wire, stranded wire or prepared wires with spade or ring lugs Ability to use larger screwdriver High visibility of wire insertion Some terminal blocks mount on both A-B rail and DIN rail Bulletin 1492-H Finger-Safe Terminal Blocks Some terminal blocks are gangable for muti-pole installationn Pull-apart terminal blocks available High-temperature terminal blocks available High-density design Single-level and double-level, as well as some specialty terminal blocks available Some terminal blocks mount on both A-B rail and DIN rail Bulletin 1492 Panel Mount Terminal Blocks

The 2005 National Electric Code (NEC) and UL 508A (effective April 25, 2006) require many electrical panels to have shortcircuit current ratings (SCCRs). Rockwell Automation is a leader in the industry for supplying a broad range of products with high-fault SCCRs, including but not limited to: terminal blocks, power blocks, circuit breakers, contactors, disconnects and drives. These ratings allow terminal blocks and power distribution blocks to be used in conjunction with fuses, motor protection circuit breakers, and motor circuit protectors in power circuits. When you use components with SCCRs rated jointly, the process of obtaining SCCRs for UL 508A electrical panels may be simplified. All terminal blocks were granted a default 10 ka SCCR for use in power circuits (UL508A). The UL508A offers criteria for determining panel SCCR based upon the component with the lowest SCCR in the power circuit, creating a limitation 10 ka for power circuits using untested terminal blocks. Many users that comply with the UL508A standard are looking to achieve overall system ratings between 25 ka and 100 ka. To assist our customers and support UL requirements, we offer several types of terminal blocks tested and certified by UL with high-fault SCCRs. We also meet or exceed requirements of CSA, IEC, NEMA and other international standards. By meeting these requirements and with our global capabilities, our products can be used in the US and incorporated into equipment which will be exported around the world. Short Circuit Current Rating Technical Data High-fault component short circuit current rating information is available online www.rockwellautomation.com/products/certification/ul508a/ Technical data: SCCR-TD001A-EN-P Terminal Blocks: 1492-PP019C-EN-P Power Distribution Blocks: 1492-TD013B-EN-P 1492-PP020A-EN-P Rockwell Automation offers a breadth of quality Allen-Bradley components to fit your specific needs. In order to assist you with your component selection, we offer a variety of configuration and selection tools. Local Distributor Call 1.800.223.3354 to contact your local Distributor today. http://www.rockwellautomation.com/distributor/ On-Line Product Directory Our extensive product portfolio is designed to improve your processes through every stage of your manufacturing cycle. http://www.rockwellautomation.com/products/ Product Selection Toolbox Our powerful range of product selection and system configuration tools assist you in choosing and applying our products. http://www.rockwellautomation.com/en/e-tools/ Catalogs Within our catalogs you ll find an extensive selection of essential Allen-Bradley component products. http://www.ab.com/catalogs/ Allen-Bradley, ClearMark and ClearTools are trademarks of Rockwell Automation. Publication 1492-BR018B-EN-P July 2010 Supersedes Publication 1492-BR018A-EN-P October 2009 Copyright 2010 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.